YOU ARE DOWNLOADING DOCUMENT

Please tick the box to continue:

Transcript
Page 1: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

TA: 0:16 PAT: Off Voxel size: 2.0×1.6×6.0 mm Rel. SNR: 1.00 SIEMENS: gre

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OffLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

Off

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 3 Dist. factor 50 % Position L0.0 P49.4 F12.1 Orientation Coronal Phase enc. dir. R >> L Rotation 0.00 degSlice group 2 Slices 3 Dist. factor 50 % Position L0.0 P67.4 F12.1 Orientation Transversal Phase enc. dir. A >> P Rotation 0.00 degSlice group 3 Slices 1 Dist. factor 50 % Position L0.0 P45.6 H12.9 Orientation Sagittal Phase enc. dir. A >> P Rotation 0.00 degPhase oversampling 38 %FoV read 400 mmFoV phase 100.0 %Slice thickness 6.0 mmTR 7.5 msTE 3.36 msAverages 1Concatenations 7Filter Distortion Corr.(2D)Coil elements HEP;NE1,2;SP1-4

ContrastTD 0 msMTC OffMagn. preparation NoneFlip angle 20 degFat suppr. NoneWater suppr. NoneSWI Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 1Multiple series Each measurement

ResolutionBase resolution 256

Phase resolution 80 %Phase partial Fourier OffInterpolation On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode NoneMatrix Coil Mode Auto (CP)

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OnMode 2DUnfiltered images OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter Off

GeometryMulti-slice mode SequentialSeries Interleaved

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Saturation mode StandardSpecial sat. None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tim CT mode Off

SystemBody OffNE2 OnNE1 OnHEP OnSP4 OnSP2 OnSP8 OffSP6 OffSP3 OnSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode FIXTable position HTable position 0 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal H >> FSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode Tune upAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position Isocenter Orientation Transversal Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm

Physio1st Signal/Mode NoneSegments 1

1/+

Page 2: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tagging NoneDark blood Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Resp. control Off

InlineSubtract OffLiver registration OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra OffMIP-Time OffSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Wash - In OffWash - Out OffTTP OffPEI OffMIP - time Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

MapIt NoneContrasts 1

SequenceIntroduction OnDimension 2DPhase stabilisation OffAsymmetric echo OffBandwidth 320 Hz/PxFlow comp. NoAllowed delay 0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type NormalGradient mode NormalExcitation Slice-sel.RF spoiling On

2/+

Page 3: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\TOF_2D_TRA

TA: 10:39 PAT: 2 Voxel size: 1.0×0.5×3.0 mm Rel. SNR: 1.00 SIEMENS: fl_tof

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OffLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 92 Dist. factor -33.00 % Position L0.0 P24.9 F25.7 Orientation T > C-7.9 Phase enc. dir. R >> L Rotation 90.00 degPhase oversampling 20 %FoV read 256 mmFoV phase 100.0 %Slice thickness 3.0 mmTR 41 msTE 5.02 msAverages 1Concatenations 92Filter Elliptical filterCoil elements HEP;NE1,2;SP1-4

ContrastTD 0.000 msMTC OffFlip angle 60 degFat suppr. NoneWater suppr. None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 1Multiple series Each measurement

ResolutionBase resolution 512Phase resolution 50 %Phase partial Fourier OffInterpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter On

Mode InplanePOCS Off

GeometryMulti-slice mode SequentialSeries Descending

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Sat. region 1 Thickness 86 mm Position L0.0 A41.3 H4.1 Orientation C > T5.7Special sat. Tracking HGap 10 mmThickness 40 mm

SystemBody OffNE2 OnNE1 OnHEP OnSP4 OnSP2 OnSP8 OffSP6 OffSP3 OnSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode REFTable position HTable position 0 mmMSMA S - C - TSagittal R >> LCoronal P >> ATransversal F >> HSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode StandardAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position L0.0 P24.9 F25.7 Orientation T > C-7.9 Rotation 90.00 deg A >> P 256 mm R >> L 256 mm F >> H 186 mm

Physio1st Signal/Mode None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Dark blood Off

Angio- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OnMIP-Cor On

3/+

Page 4: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

MIP-Tra OnMIP-Time OffSave original images On

SequenceIntroduction OnDimension 2DAsymmetric echo AllowedContrasts 1Bandwidth 217 Hz/PxFlow comp. Yes

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Gradient mode FastRF spoiling On

4/+

Page 5: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\TOF_2D_TRA_FOR AZYGUS ARCH

TA: 5:12 PAT: 2 Voxel size: 1.0×0.5×3.0 mm Rel. SNR: 1.00 SIEMENS: fl_tof

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OffLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 46 Dist. factor -33.00 % Position R12.6 P20.5 H31.3 Orientation T > C38.2 > S25.7 Phase enc. dir. R >> L Rotation 90.00 degPhase oversampling 20 %FoV read 256 mmFoV phase 100.0 %Slice thickness 3.0 mmTR 40 msTE 5.02 msAverages 1Concatenations 46Filter Elliptical filterCoil elements HEP;NE1,2;SP1-4

ContrastTD 0.000 msMTC OffFlip angle 60 degFat suppr. NoneWater suppr. None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 1Multiple series Each measurement

ResolutionBase resolution 512Phase resolution 50 %Phase partial Fourier OffInterpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter On

Mode InplanePOCS Off

GeometryMulti-slice mode SequentialSeries Ascending

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Sat. region 1 Thickness 86 mm Position L0.0 A41.3 H4.1 Orientation C > T5.7Special sat. Tracking FGap 10 mmThickness 40 mm

SystemBody OffNE2 OnNE1 OnHEP OnSP4 OnSP2 OnSP8 OffSP6 OffSP3 OnSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode REFTable position HTable position 0 mmMSMA S - C - TSagittal R >> LCoronal P >> ATransversal F >> HSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode StandardAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position R12.6 P20.5 H31.3 Orientation T > C38.2 > S25.7 Rotation 90.00 deg A >> P 256 mm R >> L 256 mm F >> H 94 mm

Physio1st Signal/Mode None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Dark blood Off

Angio- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OnMIP-Cor On

5/+

Page 6: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

MIP-Tra OnMIP-Time OffSave original images On

SequenceIntroduction OnDimension 2DAsymmetric echo AllowedContrasts 1Bandwidth 217 Hz/PxFlow comp. Yes

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Gradient mode FastRF spoiling On

6/+

Page 7: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\fl3_50_tp_retro_iPAT_.57X.57x2.5-fa20

TA: 1:42 PAT: 2 Voxel size: 0.6×0.6×2.5 mm Rel. SNR: 1.00 SIEMENS: fl_fq_retro

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OnLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 1 Dist. factor 20 % Position R4.5 P47.9 H25.0 Orientation T > C-9.9 Phase enc. dir. A >> P Rotation 0.00 degPhase oversampling 0 %FoV read 256 mmFoV phase 100.0 %Slice thickness 2.5 mmTR 95.25 msTE 10.00 msAverages 1Concatenations 1Filter Distortion Corr.(2D)Coil elements NE1,2;SP1-3

ContrastFlip angle 20 deg

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Long termReconstruction MagnitudeMeasurements 1Multiple series Off

ResolutionBase resolution 448Phase resolution 100 %Phase partial Fourier OffInterpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OnMode 2DUnfiltered images OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter Off

GeometryMulti-slice mode Sequential

Series Ascending- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Special sat. None

SystemBody OffNE2 OnNE1 OnHEP OffSP4 OffSP2 OnSP8 OffSP6 OffSP3 OnSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode REFTable position HTable position 0 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal F >> HCoil Combine Mode Sum of SquaresAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode Tune upAdjust with body coil OnConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position Isocenter Orientation Transversal Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm

Physio1st Signal/Mode Pulse/RetroAverage cycle No Signal msCalculated phases 30Segments 3Arrhythmia detection None

AngioFlow mode Single dir.Encodings 1Velocity enc. 50 cm/sDirection Through planeRephased images OnMagnitude images OnPhase images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra OffMIP-Time Off

7/+

Page 8: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

Save original images On

SequenceIntroduction OffAsymmetric echo StrongContrasts 1Bandwidth 192 Hz/PxFlow comp. No

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type NormalGradient mode FastRF spoiling On

8/+

Page 9: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer

TA: 0:13 PAT: Off Voxel size: 1.4×1.3×7.0 mm Rel. SNR: 1.00 SIEMENS: gre

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OnLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 1 Dist. factor 20 % Position L0.6 A31.5 H0.0 Orientation Sagittal Phase enc. dir. A >> P Rotation 0.00 degSlice group 2 Slices 1 Dist. factor 20 % Position L0.6 A31.5 H0.0 Orientation Transversal Phase enc. dir. A >> P Rotation 0.00 degSlice group 3 Slices 1 Dist. factor 20 % Position L0.6 A31.5 H0.0 Orientation Coronal Phase enc. dir. R >> L Rotation 0.00 degPhase oversampling 0 %FoV read 320 mmFoV phase 100.0 %Slice thickness 7.0 mmTR 8.6 msTE 4.00 msAverages 2Concatenations 3Filter Prescan Normalize, Elliptical

filterCoil elements HEA;HEP;NE1,2

ContrastTD 0 msMTC OffMagn. preparation NoneFlip angle 20 degFat suppr. NoneWater suppr. NoneSWI Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 1Multiple series Each measurement

Resolution

Base resolution 256Phase resolution 90 %Phase partial Fourier OffInterpolation On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode NoneMatrix Coil Mode Auto (CP)

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OffUnfiltered images OffPrescan Normalize OnNormalize OffB1 filter OffRaw filter OffElliptical filter OnMode Inplane

GeometryMulti-slice mode SequentialSeries Interleaved

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Saturation mode StandardSpecial sat. None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tim CT mode Off

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OffSP8 OffSP6 OffSP3 OffSP1 OffSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode REFTable position HTable position 0 mmMSMA S - C - TSagittal R >> LCoronal P >> ATransversal F >> HSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode Tune upAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position Isocenter Orientation Transversal Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm

Physio9/+

Page 10: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

1st Signal/Mode NoneSegments 1

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tagging NoneDark blood Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Resp. control Off

InlineSubtract OffLiver registration OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra OffMIP-Time OffSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Wash - In OffWash - Out OffTTP OffPEI OffMIP - time Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

MapIt NoneContrasts 1

SequenceIntroduction OnDimension 2DPhase stabilisation OffAsymmetric echo AllowedBandwidth 320 Hz/PxFlow comp. NoAllowed delay 0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type NormalGradient mode NormalExcitation Slice-sel.RF spoiling On

10/+

Page 11: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\DUAL-SWI_tra_p2_24_TE6/20_.5x.5x2

TA: 6:39 PAT: 2 Voxel size: 1.0×0.5×2.0 mm Rel. SNR: 1.00 SIEMENS: gre

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OffLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlab group 1 Slabs 1 Dist. factor 20 % Position R8.6 P6.2 F38.0 Orientation T > S4.2 > C0.4 Phase enc. dir. R >> L Rotation 90.00 degPhase oversampling 0 %Slice oversampling 0.0 %Slices per slab 128FoV read 256 mmFoV phase 75.0 %Slice thickness 2.00 mmTR 29 msTE 1 6.00 msTE 2 20.00 msAverages 1Concatenations 1Filter NoneCoil elements HEA;HEP;NE1,2

ContrastMTC OffMagn. preparation NoneFlip angle 15 degFat suppr. NoneWater suppr. NoneSWI On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction Magn./PhaseMeasurements 1Multiple series Each measurement

ResolutionBase resolution 512Phase resolution 50 %Slice resolution 100 %Phase partial Fourier OffSlice partial Fourier OffInterpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Accel. factor 3D 1Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter Off

GeometryMulti-slice mode InterleavedSeries Interleaved

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Saturation mode StandardSpecial sat. None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tim CT mode Off

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OffSP8 OffSP6 OffSP3 OffSP1 OffSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode FIXTable position HTable position 0 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal F >> HSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode StandardAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position R8.6 P6.2 F38.0 Orientation T > S4.2 > C0.4 Rotation 90.00 deg A >> P 256 mm R >> L 192 mm F >> H 256 mm

Physio1st Signal/Mode NoneSegments 1

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tagging NoneDark blood Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Resp. control Off

InlineSubtract Off

11/+

Page 12: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

Liver registration OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra OffMIP-Time OffSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Wash - In OffWash - Out OffTTP OffPEI OffMIP - time Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

MapIt NoneContrasts 2

SequenceIntroduction OnDimension 3DElliptical scanning OffPhase stabilisation OffAsymmetric echo AllowedBandwidth 1 470 Hz/PxBandwidth 2 120 Hz/PxFlow comp. 1 YesFlow comp. 2 NoReadout mode BipolarAllowed delay 0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type FastGradient mode NormalExcitation Slab-sel.RF spoiling On

12/+

Page 13: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\3D SPACE SAG FLAIR

TA: 5:20 PAT: 2 Voxel size: 1.0×1.0×1.0 mm Rel. SNR: 1.00 SIEMENS: tse_vfl

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OnLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlab group 1 Slabs 1 Position R3.5 P1.1 F35.0 Orientation S > T-3.9 > C0.8 Phase enc. dir. A >> P Rotation 0.20 degPhase oversampling 0 %Slice oversampling 0.0 %Slices per slab 160FoV read 256 mmFoV phase 100.0 %Slice thickness 1.00 mmTR 6000 msTE 397 msAverages 1.0Concatenations 1Filter Raw filter, Distortion

Corr.(2D), Prescan NormalizeCoil elements HEA;HEP;NE1,2

ContrastMTC OffMagn. preparation Non-sel. IRTI 2200 msFat suppr. NoneWater suppr. NoneRestore magn. Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Reconstruction MagnitudeMeasurements 1Multiple series Each measurement

ResolutionBase resolution 256Phase resolution 101 %Slice resolution 75 %Phase partial Fourier AllowedSlice partial Fourier 7/8Interpolation On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Accel. factor 3D 1Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. On

Mode 2DUnfiltered images OffUnfiltered images OffPrescan Normalize OnNormalize OffB1 filter OffRaw filter OnIntensity WeakSlope 25Elliptical filter Off

Geometry- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Special sat. None- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OffSP8 OffSP6 OffSP3 OffSP1 OffSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode REFTable position HTable position 0 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal F >> HSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode StandardAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position R3.5 P1.1 F35.0 Orientation S > T-3.9 > C0.8 Rotation 0.20 deg F >> H 256 mm A >> P 256 mm R >> L 160 mm

Physio1st Signal/Mode None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Dark blood Off- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Resp. control Off

InlineSubtract OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time Off

13/+

Page 14: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

MIP-Sag OffMIP-Cor OffMIP-Tra OffMIP-Time OffSave original images On

SequenceIntroduction OnDimension 3DBandwidth 781 Hz/PxFlow comp. NoAllowed delay 30 sEcho spacing 3.32 msAdiabatic-mode Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Define Echo trainsTurbo factor 141Slice turbo factor 2Echo trains per slice 1Echo train duration 860RF pulse type NormalGradient mode FastExcitation Non-sel.Flip angle mode T2 var

14/+

Page 15: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\T1 AXIAL PRE

TA: 3:25 PAT: Off Voxel size: 1.0×1.0×3.0 mm Rel. SNR: 1.00 SIEMENS: gre

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OnLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 46 Dist. factor 0 % Position L0.6 P3.6 F10.2 Orientation Transversal Phase enc. dir. R >> L Rotation 90.00 degPhase oversampling 0 %FoV read 256 mmFoV phase 100.0 %Slice thickness 3.0 mmTR 400.0 msTE 4.47 msAverages 2Concatenations 1Filter Prescan Normalize, Elliptical

filterCoil elements HEA;HEP;NE1,2

ContrastMTC OffMagn. preparation NoneFlip angle 80 degFat suppr. NoneWater suppr. NoneSWI Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 1Multiple series Each measurement

ResolutionBase resolution 256Phase resolution 100 %Phase partial Fourier OffInterpolation On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode NoneMatrix Coil Mode Auto (CP)

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OffUnfiltered images OffPrescan Normalize OnNormalize OffB1 filter OffRaw filter OffElliptical filter On

Mode Inplane

GeometryMulti-slice mode InterleavedSeries Interleaved

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Saturation mode StandardSpecial sat. None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tim CT mode Off

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OffSP8 OffSP6 OffSP3 OffSP1 OffSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode FIXTable position HTable position 0 mmMSMA S - C - TSagittal R >> LCoronal P >> ATransversal F >> HSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode Tune upAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position Isocenter Orientation Transversal Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm

Physio1st Signal/Mode NoneSegments 1

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tagging NoneDark blood Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Resp. control Off

InlineSubtract OffLiver registration OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag Off

15/+

Page 16: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

MIP-Cor OffMIP-Tra OffMIP-Time OffSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Wash - In OffWash - Out OffTTP OffPEI OffMIP - time Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

MapIt NoneContrasts 1

SequenceIntroduction OffDimension 2DPhase stabilisation OffAsymmetric echo AllowedBandwidth 320 Hz/PxFlow comp. YesAllowed delay 0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type FastGradient mode FastExcitation Slice-sel.RF spoiling On

16/+

Page 17: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-NECK

TA: 0:19 PAT: Off Voxel size: 2.0×1.6×6.0 mm Rel. SNR: 1.00 SIEMENS: gre

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OffLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 3 Dist. factor 50 % Position Isocenter Orientation Coronal Phase enc. dir. R >> L Rotation 0.00 degSlice group 2 Slices 3 Dist. factor 50 % Position Isocenter Orientation Sagittal Phase enc. dir. A >> P Rotation 0.00 degSlice group 3 Slices 2 Dist. factor 150 % Position L0.0 P18.0 F150.0 Orientation Transversal Phase enc. dir. A >> P Rotation 0.00 degPhase oversampling 38 %FoV read 400 mmFoV phase 100.0 %Slice thickness 6.0 mmTR 7.8 msTE 3.69 msAverages 1Concatenations 8Filter Distortion Corr.(2D)Coil elements HEA;HEP;NE1,2;SP1,2

ContrastTD 0 msMTC OffMagn. preparation NoneFlip angle 20 degFat suppr. NoneWater suppr. NoneSWI Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 1Multiple series Each measurement

ResolutionBase resolution 256

Phase resolution 80 %Phase partial Fourier OffInterpolation On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode NoneMatrix Coil Mode Auto (CP)

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OnMode 2DUnfiltered images OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter Off

GeometryMulti-slice mode SequentialSeries Interleaved

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Saturation mode StandardSpecial sat. None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tim CT mode Off

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OnSP8 OffSP6 OffSP3 OffSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode FIXTable position FTable position 150 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal H >> FSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode Tune upAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position Isocenter Orientation Transversal Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm

Physio1st Signal/Mode None

17/+

Page 18: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

Segments 1- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tagging NoneDark blood Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Resp. control Off

InlineSubtract OffLiver registration OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra OffMIP-Time OffSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Wash - In OffWash - Out OffTTP OffPEI OffMIP - time Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

MapIt NoneContrasts 1

SequenceIntroduction OnDimension 2DPhase stabilisation OffAsymmetric echo OffBandwidth 320 Hz/PxFlow comp. NoAllowed delay 0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type NormalGradient mode NormalExcitation Slice-sel.RF spoiling On

18/+

Page 19: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\TOF_2D_TRA

TA: 6:57 PAT: 2 Voxel size: 1.3×0.6×3.0 mm Rel. SNR: 1.00 SIEMENS: fl_tof

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OffLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 128 Dist. factor -25.00 % Position L6.8 P24.1 F139.4 Orientation Transversal Phase enc. dir. A >> P Rotation 0.00 degPhase oversampling 0 %FoV read 320 mmFoV phase 75.0 %Slice thickness 3.0 mmTR 29 msTE 5.02 msAverages 1Concatenations 128Filter Elliptical filterCoil elements HEA;HEP;NE1,2;SP1,2

ContrastTD 0.000 msMTC OffFlip angle 60 degFat suppr. NoneWater suppr. None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 1Multiple series Each measurement

ResolutionBase resolution 512Phase resolution 50 %Phase partial Fourier OffInterpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter On

Mode InplanePOCS Off

GeometryMulti-slice mode SequentialSeries Ascending

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Special sat. Tracking FGap 10 mmThickness 40 mm

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OnSP8 OffSP6 OffSP3 OffSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode REFTable position FTable position 150 mmMSMA S - C - TSagittal R >> LCoronal P >> ATransversal F >> HSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode StandardAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position L6.8 P24.1 F139.4 Orientation Transversal Rotation 0.00 deg R >> L 320 mm A >> P 240 mm F >> H 289 mm

Physio1st Signal/Mode None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Dark blood Off

Angio- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OnMIP-Cor OnMIP-Tra OnMIP-Time OffSave original images On

19/+

Page 20: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

SequenceIntroduction OnDimension 2DAsymmetric echo AllowedContrasts 1Bandwidth 217 Hz/PxFlow comp. Yes

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Gradient mode FastRF spoiling On

20/+

Page 21: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\fl3d_vibe_SAG-PRE

TA: 1:45 PAT: 2 Voxel size: 0.9×0.9×0.9 mm Rel. SNR: 1.00 SIEMENS: fl3d_vibe

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OffLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlab group 1 Slabs 1 Dist. factor 20 % Position L0.9 P13.0 F103.4 Orientation Sagittal Phase enc. dir. A >> P Rotation 0.20 degPhase oversampling 0 %Slice oversampling 0.0 %Slices per slab 256FoV read 352 mmFoV phase 78.1 %Slice thickness 0.90 mmTR 3.97 msTE 1.43 msAverages 1Concatenations 1Filter Distortion Corr.(2D),

NormalizeCoil elements HEA;HEP;NE1,2;SP1,2

ContrastFlip angle 25.0 degFat suppr. Q-fat sat.Lines Per Shot 205Water suppr. NoneDixon No DixonSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 1Multiple series Each measurement

ResolutionBase resolution 384Phase resolution 100 %Slice resolution 100 %Phase partial Fourier 6/8Slice partial Fourier 6/8Interpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Accel. factor 3D 1Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OnMode 2DUnfiltered images OffPrescan Normalize OffNormalize OnIntensity MediumCut off 20Width 4Unfiltered images OffB1 filter OffRaw filter OffElliptical filter OffPOCS Off

GeometryMulti-slice mode SequentialSeries Ascending

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Special sat. None- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OnSP8 OffSP6 OffSP3 OffSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode REFTable position FTable position 150 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal F >> HSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode StandardAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position L0.9 P13.0 F103.4 Orientation Sagittal Rotation 0.20 deg F >> H 352 mm A >> P 275 mm R >> L 231 mm

Physio1st Signal/Mode None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Resp. control Off

Inline

21/+

Page 22: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

3D centric reordering OffTime to center 35.0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffLiver registration OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra OffMIP-Time OffSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Wash - In OffWash - Out OffTTP OffPEI OffMIP - time Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

MapIt NoneContrasts 1

SequenceIntroduction OffDimension 3DElliptical scanning OffReordering CentricAsymmetric echo WeakBandwidth 690 Hz/PxOptimization Min. TEAllowed delay 0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type FastGradient mode Fast*Excitation Non-sel.RF spoiling On

22/+

Page 23: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\CORONAL 3D_ 0.9X0.9X0.9_10

TA: 3:21 PAT: 4 Voxel size: 0.9×0.9×0.9 mm Rel. SNR: 1.00 SIEMENS: fl3d_ce

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OnLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlab group 1 Slabs 1 Dist. factor 20 % Position L2.9 P14.7 F164.2 Orientation C > T4.6 Phase enc. dir. R >> L Rotation 0.00 degPhase oversampling 0 %Slice oversampling 11.1 %Slices per slab 72FoV read 340 mmFoV phase 75.0 %Slice thickness 0.90 mmTR 3.31 msTE 1.25 msAverages 1Filter NoneCoil elements HEA;HEP;NE1,2;SP1,2

ContrastMagn. preparation NoneFlip angle 20 degFat suppr. None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 20Pause after meas. 1 0.0 sPause after meas. 2 0.0 sPause after meas. 3 0.0 sPause after meas. 4 0.0 sPause after meas. 5 0.0 sPause after meas. 6 0.0 sPause after meas. 7 0.0 sPause after meas. 8 0.0 sPause after meas. 9 0.0 sPause after meas. 10 0.0 sPause after meas. 11 0.0 sPause after meas. 12 0.0 sPause after meas. 13 0.0 sPause after meas. 14 0.0 sPause after meas. 15 0.0 sPause after meas. 16 0.0 sPause after meas. 17 0.0 sPause after meas. 18 0.0 sPause after meas. 19 0.0 sMultiple series Each measurement

ResolutionBase resolution 384Phase resolution 100 %Slice resolution 63 %Phase partial Fourier 6/8Slice partial Fourier 6/8Interpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Accel. factor 3D 2Ref. lines 3D 24Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter Off

GeometryMulti-slice mode SequentialSeries Ascending

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Special sat. None

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OnSP8 OffSP6 OffSP3 OffSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode REFTable position FTable position 150 mmMSMA S - C - TSagittal R >> LCoronal P >> ATransversal F >> HSave uncombined OffCoil Combine Mode Sum of SquaresAuto Coil Select Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode Tune upAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance MaximumAdjust volume Position Isocenter Orientation Transversal Rotation 0.00 deg R >> L 350 mm

23/+

Page 24: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

A >> P 263 mm F >> H 350 mm

Physio1st Signal/Mode NoneSegments 1

Angio3D centric reordering OnTime to center 1.0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra OffMIP-Time OffSave original images On

SequenceIntroduction OffDimension 3DElliptical scanning OffAsymmetric echo AllowedBandwidth 650 Hz/PxOptimization Min. TE TRAllowed delay 0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type NormalGradient mode FastExcitation Slab-sel.RF spoiling OnPhase Enc. Rewinder On

24/+

Page 25: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\fl3d_vibe_SAG-POST

TA: 1:45 PAT: 2 Voxel size: 0.9×0.9×0.9 mm Rel. SNR: 1.00 SIEMENS: fl3d_vibe

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OffLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlab group 1 Slabs 1 Dist. factor 20 % Position L0.9 P13.0 F103.4 Orientation Sagittal Phase enc. dir. A >> P Rotation 0.20 degPhase oversampling 0 %Slice oversampling 0.0 %Slices per slab 256FoV read 352 mmFoV phase 78.1 %Slice thickness 0.90 mmTR 3.97 msTE 1.43 msAverages 1Concatenations 1Filter Distortion Corr.(2D),

NormalizeCoil elements HEA;HEP;NE1,2;SP1,2

ContrastFlip angle 25.0 degFat suppr. Q-fat sat.Lines Per Shot 205Water suppr. NoneDixon No DixonSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 1Multiple series Each measurement

ResolutionBase resolution 384Phase resolution 100 %Slice resolution 100 %Phase partial Fourier 6/8Slice partial Fourier 6/8Interpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Accel. factor 3D 1Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OnMode 2DUnfiltered images OffPrescan Normalize OffNormalize OnIntensity MediumCut off 20Width 4Unfiltered images OffB1 filter OffRaw filter OffElliptical filter OffPOCS Off

GeometryMulti-slice mode SequentialSeries Ascending

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Special sat. None- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OnSP8 OffSP6 OffSP3 OffSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode FIXTable position FTable position 150 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal F >> HSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode StandardAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position L0.9 P13.0 F103.4 Orientation Sagittal Rotation 0.20 deg F >> H 352 mm A >> P 275 mm R >> L 231 mm

Physio1st Signal/Mode None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Resp. control Off

Inline

25/+

Page 26: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

3D centric reordering OffTime to center 35.0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffLiver registration OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra OffMIP-Time OffSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Wash - In OffWash - Out OffTTP OffPEI OffMIP - time Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

MapIt NoneContrasts 1

SequenceIntroduction OffDimension 3DElliptical scanning OffReordering CentricAsymmetric echo WeakBandwidth 690 Hz/PxOptimization Min. TEAllowed delay 0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type FastGradient mode Fast*Excitation Non-sel.RF spoiling On

26/+

Page 27: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\fl3_15_tp_retro_iPAT_.57X.57x2.5-fa20

TA: 1:42 PAT: 2 Voxel size: 0.6×0.6×2.5 mm Rel. SNR: 1.00 SIEMENS: fl_fq_retro

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OnLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 1 Dist. factor 20 % Position L6.8 P20.2 F106.3 Orientation T > C15.8 Phase enc. dir. A >> P Rotation 0.00 degPhase oversampling 0 %FoV read 256 mmFoV phase 100.0 %Slice thickness 2.5 mmTR 95.25 msTE 10.00 msAverages 1Concatenations 1Filter Distortion Corr.(2D)Coil elements HEA;HEP;NE1,2;SP1,2

ContrastFlip angle 20 deg

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Long termReconstruction MagnitudeMeasurements 1Multiple series Off

ResolutionBase resolution 448Phase resolution 100 %Phase partial Fourier OffInterpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OnMode 2DUnfiltered images OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter Off

GeometryMulti-slice mode Sequential

Series Ascending- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Special sat. None

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OnSP8 OffSP6 OffSP3 OffSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode FIXTable position FTable position 150 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal F >> HCoil Combine Mode Sum of SquaresAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode Tune upAdjust with body coil OnConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position Isocenter Orientation Transversal Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm

Physio1st Signal/Mode Pulse/RetroAverage cycle No Signal msCalculated phases 30Segments 3Arrhythmia detection None

AngioFlow mode Single dir.Encodings 1Velocity enc. 15 cm/sDirection Through planeRephased images OnMagnitude images OnPhase images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra Off

27/+

Page 28: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

MIP-Time OffSave original images On

SequenceIntroduction OffAsymmetric echo StrongContrasts 1Bandwidth 192 Hz/PxFlow comp. No

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type NormalGradient mode FastRF spoiling On

28/+

Page 29: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\fl3_50_tp_retro_iPAT_.57X.57x2.5-fa20

TA: 1:42 PAT: 2 Voxel size: 0.6×0.6×2.5 mm Rel. SNR: 1.00 SIEMENS: fl_fq_retro

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OnLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 1 Dist. factor 20 % Position L6.8 P15.0 F188.3 Orientation T > C-10.5 Phase enc. dir. A >> P Rotation 0.00 degPhase oversampling 0 %FoV read 256 mmFoV phase 100.0 %Slice thickness 2.5 mmTR 95.25 msTE 10.00 msAverages 1Concatenations 1Filter Distortion Corr.(2D)Coil elements HEA;HEP;NE1,2;SP1,2

ContrastFlip angle 20 deg

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Long termReconstruction MagnitudeMeasurements 1Multiple series Off

ResolutionBase resolution 448Phase resolution 100 %Phase partial Fourier OffInterpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OnMode 2DUnfiltered images OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter Off

GeometryMulti-slice mode Sequential

Series Ascending- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Special sat. None

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OnSP8 OffSP6 OffSP3 OffSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode REFTable position FTable position 150 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal F >> HCoil Combine Mode Sum of SquaresAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode Tune upAdjust with body coil OnConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position Isocenter Orientation Transversal Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm

Physio1st Signal/Mode Pulse/RetroAverage cycle No Signal msCalculated phases 30Segments 3Arrhythmia detection None

AngioFlow mode Single dir.Encodings 1Velocity enc. 50 cm/sDirection Through planeRephased images OnMagnitude images OnPhase images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra Off

29/+

Page 30: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

MIP-Time OffSave original images On

SequenceIntroduction OffAsymmetric echo StrongContrasts 1Bandwidth 192 Hz/PxFlow comp. No

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type NormalGradient mode FastRF spoiling On

30/+

Page 31: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\fl3_50_tp_retro_iPAT_.57X.57x2.5-fa20

TA: 1:42 PAT: 2 Voxel size: 0.6×0.6×2.5 mm Rel. SNR: 1.00 SIEMENS: fl_fq_retro

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OnLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 1 Dist. factor 20 % Position L6.8 P20.2 F106.3 Orientation T > C15.8 Phase enc. dir. A >> P Rotation 0.00 degPhase oversampling 0 %FoV read 256 mmFoV phase 100.0 %Slice thickness 2.5 mmTR 95.25 msTE 10.00 msAverages 1Concatenations 1Filter Distortion Corr.(2D)Coil elements HEA;HEP;NE1,2;SP1,2

ContrastFlip angle 20 deg

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Long termReconstruction MagnitudeMeasurements 1Multiple series Off

ResolutionBase resolution 448Phase resolution 100 %Phase partial Fourier OffInterpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OnMode 2DUnfiltered images OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter Off

GeometryMulti-slice mode Sequential

Series Ascending- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Special sat. None

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OnSP8 OffSP6 OffSP3 OffSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode REFTable position FTable position 150 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal F >> HCoil Combine Mode Sum of SquaresAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode Tune upAdjust with body coil OnConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position Isocenter Orientation Transversal Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm

Physio1st Signal/Mode Pulse/RetroAverage cycle No Signal msCalculated phases 30Segments 3Arrhythmia detection None

AngioFlow mode Single dir.Encodings 1Velocity enc. 50 cm/sDirection Through planeRephased images OnMagnitude images OnPhase images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra Off

31/+

Page 32: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

MIP-Time OffSave original images On

SequenceIntroduction OffAsymmetric echo StrongContrasts 1Bandwidth 192 Hz/PxFlow comp. No

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type NormalGradient mode FastRF spoiling On

32/+

Page 33: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\fl3_50_tp_retro_iPAT_.57X.57x2.5-fa20

TA: 1:42 PAT: 2 Voxel size: 0.6×0.6×2.5 mm Rel. SNR: 1.00 SIEMENS: fl_fq_retro

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OnLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 1 Dist. factor 20 % Position L6.8 P15.0 F188.3 Orientation T > C-10.5 Phase enc. dir. A >> P Rotation 0.00 degPhase oversampling 0 %FoV read 256 mmFoV phase 100.0 %Slice thickness 2.5 mmTR 95.25 msTE 10.00 msAverages 1Concatenations 1Filter Distortion Corr.(2D)Coil elements HEA;HEP;NE1,2;SP1,2

ContrastFlip angle 20 deg

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Long termReconstruction MagnitudeMeasurements 1Multiple series Off

ResolutionBase resolution 448Phase resolution 100 %Phase partial Fourier OffInterpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OnMode 2DUnfiltered images OffPrescan Normalize OffNormalize OffB1 filter OffRaw filter OffElliptical filter Off

GeometryMulti-slice mode Sequential

Series Ascending- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Special sat. None

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OnSP8 OffSP6 OffSP3 OffSP1 OnSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode REFTable position FTable position 150 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal F >> HCoil Combine Mode Sum of SquaresAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode Tune upAdjust with body coil OnConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position Isocenter Orientation Transversal Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm

Physio1st Signal/Mode Pulse/RetroAverage cycle No Signal msCalculated phases 30Segments 3Arrhythmia detection None

AngioFlow mode Single dir.Encodings 1Velocity enc. 50 cm/sDirection Through planeRephased images OnMagnitude images OnPhase images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra Off

33/+

Page 34: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

MIP-Time OffSave original images On

SequenceIntroduction OffAsymmetric echo StrongContrasts 1Bandwidth 192 Hz/PxFlow comp. No

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type NormalGradient mode FastRF spoiling On

34/+

Page 35: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\T1 AXIAL_POST

TA: 3:25 PAT: Off Voxel size: 1.0×1.0×3.0 mm Rel. SNR: 1.00 SIEMENS: gre

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OnLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlice group 1 Slices 46 Dist. factor 0 % Position L0.6 P3.6 F10.2 Orientation Transversal Phase enc. dir. R >> L Rotation 90.00 degPhase oversampling 0 %FoV read 256 mmFoV phase 100.0 %Slice thickness 3.0 mmTR 400.0 msTE 4.47 msAverages 2Concatenations 1Filter Prescan Normalize, Elliptical

filterCoil elements HEA;HEP;NE1,2

ContrastMTC OffMagn. preparation NoneFlip angle 80 degFat suppr. NoneWater suppr. NoneSWI Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 1Multiple series Each measurement

ResolutionBase resolution 256Phase resolution 100 %Phase partial Fourier OffInterpolation On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode NoneMatrix Coil Mode Auto (CP)

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OffUnfiltered images OffPrescan Normalize OnNormalize OffB1 filter OffRaw filter OffElliptical filter On

Mode Inplane

GeometryMulti-slice mode InterleavedSeries Interleaved

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Saturation mode StandardSpecial sat. None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tim CT mode Off

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OffSP8 OffSP6 OffSP3 OffSP1 OffSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode FIXTable position HTable position 0 mmMSMA S - C - TSagittal R >> LCoronal P >> ATransversal F >> HSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode Tune upAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position Isocenter Orientation Transversal Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm

Physio1st Signal/Mode NoneSegments 1

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Tagging NoneDark blood Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Resp. control Off

InlineSubtract OffLiver registration OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag Off

35/+

Page 36: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

MIP-Cor OffMIP-Tra OffMIP-Time OffSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Wash - In OffWash - Out OffTTP OffPEI OffMIP - time Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

MapIt NoneContrasts 1

SequenceIntroduction OffDimension 2DPhase stabilisation OffAsymmetric echo AllowedBandwidth 320 Hz/PxFlow comp. YesAllowed delay 0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type FastGradient mode FastExcitation Slice-sel.RF spoiling On

36/+

Page 37: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

\\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\fl3d_vibe-HEAD_POST

TA: 1:45 PAT: 2 Voxel size: 0.9×0.9×0.9 mm Rel. SNR: 1.00 SIEMENS: fl3d_vibe

PropertiesPrio Recon OffBefore measurementAfter measurementLoad to viewer OnInline movie OffAuto store images OnLoad to stamp segments OffLoad images to graphicsegments

Off

Auto open inline display OffStart measurement withoutfurther preparation

On

Wait for user to start OffStart measurements single

RoutineSlab group 1 Slabs 1 Dist. factor 20 % Position R3.5 P1.1 F35.0 Orientation S > T-3.9 > C0.8 Phase enc. dir. A >> P Rotation 0.20 degPhase oversampling 0 %Slice oversampling 0.0 %Slices per slab 256FoV read 352 mmFoV phase 78.1 %Slice thickness 0.90 mmTR 3.97 msTE 1.43 msAverages 1Concatenations 1Filter Distortion Corr.(2D),

NormalizeCoil elements HEA;HEP;NE1,2

ContrastFlip angle 25.0 degFat suppr. Q-fat sat.Lines Per Shot 205Water suppr. NoneDixon No DixonSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Averaging mode Short termReconstruction MagnitudeMeasurements 1Multiple series Each measurement

ResolutionBase resolution 384Phase resolution 100 %Slice resolution 100 %Phase partial Fourier 6/8Slice partial Fourier 6/8Interpolation Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PAT mode GRAPPAAccel. factor PE 2Ref. lines PE 24Accel. factor 3D 1Matrix Coil Mode Auto (Triple)Reference scan mode Integrated

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Image Filter OffDistortion Corr. OnMode 2DUnfiltered images OffPrescan Normalize OffNormalize OnIntensity MediumCut off 20Width 4Unfiltered images OffB1 filter OffRaw filter OffElliptical filter OffPOCS Off

GeometryMulti-slice mode SequentialSeries Ascending

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Special sat. None- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

SystemBody OffNE2 OnNE1 OnHEP OnHEA OnSP4 OffSP2 OffSP8 OffSP6 OffSP3 OffSP1 OffSP7 OffSP5 Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Positioning mode FIXTable position HTable position 0 mmMSMA S - C - TSagittal R >> LCoronal A >> PTransversal F >> HSave uncombined OffCoil Combine Mode Adaptive CombineAuto Coil Select Default

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Shim mode StandardAdjust with body coil OffConfirm freq. adjustment OffAssume Silicone Off? Ref. amplitude 1H 0.000 VAdjustment Tolerance AutoAdjust volume Position R3.5 P1.1 F35.0 Orientation S > T-3.9 > C0.8 Rotation 0.20 deg F >> H 352 mm A >> P 275 mm R >> L 231 mm

Physio1st Signal/Mode None

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Resp. control Off

Inline

37/+

Page 38: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

3D centric reordering OffTime to center 35.0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Subtract OffLiver registration OffStd-Dev-Sag OffStd-Dev-Cor OffStd-Dev-Tra OffStd-Dev-Time OffMIP-Sag OffMIP-Cor OffMIP-Tra OffMIP-Time OffSave original images On

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Wash - In OffWash - Out OffTTP OffPEI OffMIP - time Off

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

MapIt NoneContrasts 1

SequenceIntroduction OffDimension 3DElliptical scanning OffReordering CentricAsymmetric echo WeakBandwidth 690 Hz/PxOptimization Min. TEAllowed delay 0 s

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

RF pulse type FastGradient mode Fast*Excitation Non-sel.RF spoiling On

38/+

Page 39: SIEMENS MAGNETOM Verio syngo MR B17storage.googleapis.com/wzukusers/user-17305849/... · SIEMENS MAGNETOM Verio syngo MR B17 \\USER\ZAHID_RESEARCH\NECK\CCSVI_ALTERNATE_120310\localizer-AZYGUS

SIEMENS MAGNETOM Verio syngo MR B17

Table of contents

\\USER ZAHID_RESEARCH

NECK CCSVI_ALTERNATE_120310

localizer-AZYGUS TOF_2D_TRA TOF_2D_TRA_FOR AZYGUS ARCH fl3_50_tp_retro_iPAT_.57X.57x2.5-fa20 localizer DUAL-SWI_tra_p2_24_TE6/20_.5x.5x2 3D SPACE SAG FLAIR T1 AXIAL PRE localizer-NECK TOF_2D_TRA fl3d_vibe_SAG-PRE CORONAL 3D_ 0.9X0.9X0.9_10 fl3d_vibe_SAG-POST fl3_15_tp_retro_iPAT_.57X.57x2.5-fa20 fl3_50_tp_retro_iPAT_.57X.57x2.5-fa20 fl3_50_tp_retro_iPAT_.57X.57x2.5-fa20 fl3_50_tp_retro_iPAT_.57X.57x2.5-fa20 T1 AXIAL_POST fl3d_vibe-HEAD_POST

39/-