SIEMENS MAGNETOM ConnectomS syngo MR D11 --------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel size:1.2x1.2x5.0 mm Rel. SNR:1.00 :fl --------------------------------------------------------------------------------- Properties Prio Recon On Before measurement After measurement Load to viewer Off Inline movie Off Auto store images On Load to stamp segments On Load images to graphic segments On Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 3 Slices 1 Dist. factor 20 % Position L0.0 A45.0 H0.0 mm Orientation Transversal Phase enc. dir. A >> P AutoAlign --- Phase oversampling 0 % FoV read 300 mm FoV phase 100.0 % Slice thickness 5.0 mm TR 40.0 ms TE 3.00 ms Averages 1 Concatenations 1 Filter Prescan Normalize, Elliptical filter Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 15 deg Fat suppr. None Water suppr. None SWI Off Averaging mode Short term Measurements 1 Reconstruction Magnitude Multiple series Off Resolution Base resolution 256 Phase resolution 75 % Phase partial Fourier Off Interpolation Off PAT mode None Image Filter Off Distortion Corr. Off Unfiltered images Off Prescan Normalize On Normalize Off B1 filter Off 1
104

SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Oct 05, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel size:1.2x1.2x5.0 mm Rel. SNR:1.00 :fl ---------------------------------------------------------------------------------Properties Prio Recon On Before measurement After measurement Load to viewer Off Inline movie Off Auto store images On Load to stamp segments On Load images to graphic segments On Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 3 Slices 1 Dist. factor 20 % Position L0.0 A45.0 H0.0 mm Orientation Transversal Phase enc. dir. A >> P AutoAlign --- Phase oversampling 0 % FoV read 300 mm FoV phase 100.0 % Slice thickness 5.0 mm TR 40.0 ms TE 3.00 ms Averages 1 Concatenations 1 Filter Prescan Normalize, Elliptical filter Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 15 deg Fat suppr. None Water suppr. None SWI Off Averaging mode Short term Measurements 1 Reconstruction Magnitude Multiple series Off Resolution Base resolution 256 Phase resolution 75 % Phase partial Fourier Off Interpolation Off PAT mode None Image Filter Off Distortion Corr. Off Unfiltered images Off Prescan Normalize On Normalize Off B1 filter Off

1

Page 2: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Raw filter Off Elliptical filter On Mode Inplane Geometry Nr. of slice groups 3 Slices 1 Dist. factor 20 % Position L0.0 A45.0 H0.0 mm Phase enc. dir. A >> P Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Saturation mode Standard Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Water suppr. None Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Sum of Squares AutoAlign --- Auto Coil Select Default Shim mode Tune up Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position Isocenter Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm Frequency 1H 123.253687 MHz Correction factor 1 SRFExcit 1H 19.740 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Segments 1 Magn. preparation None Dark blood Off Resp. control Off

2

Page 3: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Inline Distortion correction Off Sequence Introduction On Dimension 2D Phase stabilisation On Averaging mode Short term Multi-slice mode Interleaved Asymmetric echo Allowed Contrasts 1 Bandwidth 260 Hz/Px Flow comp. No Allowed delay 0 s RF pulse type Normal Gradient mode Fast Excitation Slice-sel. RF spoiling On TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms Mode Off BOLD Subtract Off Liver registration Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On Distortion Corr. Off Contrasts 1 Save original images On Wash - In Off Wash - Out Off TTP Off PEI Off MIP - time Off Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11---------------------------------------------------------------------------------

3

Page 4: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\AAHScout TA:0:14 PAT:3 Voxel size:1.6x1.6x1.6 mm Rel. SNR:1.00 :fl ---------------------------------------------------------------------------------Properties Prio Recon On Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slab groups 1 Slabs 1 Dist. factor 20 % Position L0.0 A45.0 H0.0 mm Orientation Sagittal Phase enc. dir. A >> P Phase oversampling 0 % Slice oversampling 0.0 % FoV read 260 mm FoV phase 100.0 % Slice thickness 1.6 mm TR 3.15 ms TE 1.37 ms Averages 1 Concatenations 1 Filter Prescan Normalize Coil elements HEA;HEP AutoAlign Head Contrast Flip angle 8 deg Averaging mode Short term Measurements 1 Reconstruction Magnitude Resolution Base resolution 160 Phase resolution 100 % Phase partial Fourier 6/8 PAT mode GRAPPA Accel. factor PE 3 Ref. lines PE 24 Reference scan mode Integrated Image Filter Off Distortion Corr. Off Accel. factor 3D 1 Unfiltered images Off Prescan Normalize On Normalize Off B1 filter Off Raw filter Off Elliptical filter Off Slice resolution 69 % Slice partial Fourier 6/8 Geometry Nr. of slab groups 1

4

Page 5: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Slabs 1 Dist. factor 20 % Position L0.0 A45.0 H0.0 mm Phase enc. dir. A >> P Phase oversampling 0 % Slice oversampling 0.0 % Slices per slab 128 Multi-slice mode Sequential Series Ascending Nr. of sat. regions 0 Position mode L-P-H Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Adaptive Combine Auto Coil Select Off Shim mode Tune up Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position Isocenter Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm Frequency 1H 123.253687 MHz Correction factor 1 SRFExcit 1H 24.593 V Gain Low Table position 0 mm Img. Scale. Cor. 1.000 PhysioInline Distortion correction Off Sequence Introduction On Dimension 3D Averaging mode Short term Multi-slice mode Sequential Asymmetric echo Weak Contrasts 1 Bandwidth 540 Hz/Px RF pulse type Fast Gradient mode Normal Excitation Non-sel.

5

Page 6: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

RF spoiling On TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms Mode Off BOLD Time to center 6.2 s Subtract Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On Distortion Corr. Off Contrasts 1 Save original images On Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer_aligned TA:0:22 PAT:Off Voxel size:1.2x1.2x5.0 mm Rel. SNR:1.00 :fl ---------------------------------------------------------------------------------Properties Prio Recon On Before measurement After measurement Load to viewer Off Inline movie Off Auto store images On Load to stamp segments On Load images to graphic segments On Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slice groups 3 Slices 1 Dist. factor 20 % Position Isocenter Orientation Transversal

6

Page 7: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Phase enc. dir. A >> P AutoAlign Head > Brain Phase oversampling 0 % FoV read 300 mm FoV phase 100.0 % Slice thickness 5.0 mm TR 104.0 ms TE 3.00 ms Averages 1 Concatenations 1 Filter Prescan Normalize, Elliptical filter Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 15 deg Fat suppr. None Water suppr. None SWI Off Averaging mode Short term Measurements 1 Reconstruction Magnitude Multiple series Off Resolution Base resolution 256 Phase resolution 75 % Phase partial Fourier Off Interpolation Off PAT mode None Image Filter Off Distortion Corr. Off Unfiltered images Off Prescan Normalize On Normalize Off B1 filter Off Raw filter Off Elliptical filter On Mode Inplane Geometry Nr. of slice groups 3 Slices 1 Dist. factor 20 % Position Isocenter Phase enc. dir. A >> P Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Saturation mode Standard Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Water suppr. None Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H

7

Page 8: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Tune up Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position Isocenter Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm Frequency 1H 123.253687 MHz Correction factor 1 SRFExcit 1H 19.740 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Segments 1 Magn. preparation None Dark blood Off Resp. control Off Inline Distortion correction Off Sequence Introduction On Dimension 2D Phase stabilisation On Averaging mode Short term Multi-slice mode Interleaved Asymmetric echo Allowed Contrasts 1 Bandwidth 260 Hz/Px Flow comp. No Allowed delay 0 s RF pulse type Normal Gradient mode Fast Excitation Slice-sel. RF spoiling On TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms Mode Off BOLD Subtract Off

8

Page 9: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Liver registration Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On Distortion Corr. Off Contrasts 1 Save original images On Wash - In Off Wash - Out Off TTP Off PEI Off MIP - time Off Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\BIAS_BC TA:0:26 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :tfl ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slab groups 1 Slabs 1 Dist. factor 50 % Position Isocenter Orientation Sagittal Phase enc. dir. A >> P AutoAlign Head > Brain Phase oversampling 0 % Slice oversampling 18.2 %

9

Page 10: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

FoV read 256 mm FoV phase 100.0 % Slice thickness 2.00 mm TR 250.0 ms TE 1.01 ms Averages 1 Concatenations 1 Filter None Coil elements BC Contrast Magn. preparation None Flip angle 3 deg Fat suppr. None Water suppr. None Averaging mode Long term Measurements 1 Reconstruction Magnitude Multiple series Each measurement Resolution Base resolution 128 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation Off PAT mode None Image Filter Off Distortion Corr. Off Prescan Normalize Off Normalize Off B1 filter Off Raw filter Off Elliptical filter Off Slice resolution 100 % Slice partial Fourier 6/8 Geometry Nr. of slab groups 1 Slabs 1 Dist. factor 50 % Position Isocenter Phase enc. dir. A >> P Phase oversampling 0 % Slice oversampling 18.2 % Slices per slab 88 Multi-slice mode Single shot Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Water suppr. None Special sat. None Table position P System Body On HEP Off HEA Off Position mode L-P-H Positioning mode FIX Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L

10

Page 11: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Tune up Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position Isocenter Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm Frequency 1H 123.253687 MHz Correction factor 1 SRFExcit 1H 27.667 V Gain Low Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Dark blood Off Resp. control Off Inline Distortion correction Off Sequence Introduction On Dimension 3D Elliptical scanning Off Averaging mode Long term Multi-slice mode Single shot Reordering Linear Asymmetric echo Allowed Bandwidth 540 Hz/Px Flow comp. No Echo spacing 3 ms Turbo factor 78 RF pulse type Fast Gradient mode Fast Excitation Non-sel. RF spoiling On TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements BC Acquisition duration 0 ms Mode Off BOLD Subtract Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1

11

Page 12: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Subtraction indices StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On Distortion Corr. Off Save original images On Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\BIAS_32CH TA:0:26 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :tfl ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slab groups 1 Slabs 1 Dist. factor 50 % Position Isocenter Orientation Sagittal Phase enc. dir. A >> P AutoAlign Head > Brain Phase oversampling 0 % Slice oversampling 18.2 % FoV read 256 mm FoV phase 100.0 % Slice thickness 2.00 mm TR 250.0 ms TE 1.01 ms Averages 1 Concatenations 1 Filter None Coil elements HEA;HEP Contrast Magn. preparation None Flip angle 3 deg

12

Page 13: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Fat suppr. None Water suppr. None Averaging mode Long term Measurements 1 Reconstruction Magnitude Multiple series Each measurement Resolution Base resolution 128 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation Off PAT mode None Image Filter Off Distortion Corr. Off Prescan Normalize Off Normalize Off B1 filter Off Raw filter Off Elliptical filter Off Slice resolution 100 % Slice partial Fourier 6/8 Geometry Nr. of slab groups 1 Slabs 1 Dist. factor 50 % Position Isocenter Phase enc. dir. A >> P Phase oversampling 0 % Slice oversampling 18.2 % Slices per slab 88 Multi-slice mode Single shot Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Water suppr. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode FIX Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Tune up Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto

13

Page 14: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

? Ref. amplitude 1H 0.000 V Position Isocenter Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm Frequency 1H 123.253687 MHz Correction factor 1 SRFExcit 1H 27.667 V Gain Low Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Dark blood Off Resp. control Off Inline Distortion correction Off Sequence Introduction On Dimension 3D Elliptical scanning Off Averaging mode Long term Multi-slice mode Single shot Reordering Linear Asymmetric echo Allowed Bandwidth 540 Hz/Px Flow comp. No Echo spacing 3 ms Turbo factor 78 RF pulse type Fast Gradient mode Fast Excitation Non-sel. RF spoiling On TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms Mode Off BOLD Subtract Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On

14

Page 15: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Distortion Corr. Off Save original images On Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\SpinEchoFieldMap_RL TA:0:28 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 7080 ms TE 58.0 ms Multi-band accel. factor 1 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 90 deg Fat suppr. Fat sat. Grad. rev. fat suppr. Disabled Averaging mode Long term Measurements 3 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None

15

Page 16: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Grad. rev. fat suppr. Disabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 AddCSaCSatNS 1H 40.921 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence

16

Page 17: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 RF pulse type Normal Gradient mode Fast Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states Off Temp. highpass filter Off Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\SpinEchoFieldMap_LR TA:0:28 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 7080 ms TE 58.0 ms

17

Page 18: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Multi-band accel. factor 1 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 90 deg Fat suppr. Fat sat. Grad. rev. fat suppr. Disabled Averaging mode Long term Measurements 3 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Grad. rev. fat suppr. Disabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off

18

Page 19: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 AddCSaCSatNS 1H 40.921 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 RF pulse type Normal Gradient mode Fast Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states Off Temp. highpass filter Off Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\rfMRI_REST_RL TA:5:12 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off

19

Page 20: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 420 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System

20

Page 21: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00

21

Page 22: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\rfMRI_REST_LR TA:5:12 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 420 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off

22

Page 23: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px

23

Page 24: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\T1w_MPR TA:6:38 PAT:2 Voxel size:0.8x0.8x0.8 mm Rel. SNR:1.00 :tfl ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slab groups 1 Slabs 1 Dist. factor 50 % Position Isocenter Orientation Sagittal Phase enc. dir. A >> P AutoAlign Head > Brain Phase oversampling 0 % Slice oversampling 23.1 % FoV read 256 mm FoV phase 93.8 % Slice thickness 0.80 mm TR 2400.0 ms TE 2.12 ms Averages 1 Concatenations 1 Filter Prescan Normalize

24

Page 25: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Coil elements HEA;HEP Contrast Magn. preparation Non-sel. IR TI 1000 ms Flip angle 8 deg Fat suppr. Water excit. fast Water suppr. None Averaging mode Long term Measurements 1 Reconstruction Magnitude Multiple series Each measurement Resolution Base resolution 320 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode GRAPPA Accel. factor PE 2 Ref. lines PE 32 Reference scan mode Integrated Image Filter Off Distortion Corr. Off Accel. factor 3D 1 Unfiltered images On Prescan Normalize On Normalize Off B1 filter Off Raw filter Off Elliptical filter Off Slice resolution 100 % Slice partial Fourier Off Geometry Nr. of slab groups 1 Slabs 1 Dist. factor 50 % Position Isocenter Phase enc. dir. A >> P Phase oversampling 0 % Slice oversampling 23.1 % Slices per slab 208 Multi-slice mode Single shot Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Water excit. fast Water suppr. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode FIX Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H

25

Page 26: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Save uncombined Off Coil Combine Mode Adaptive Combine AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V ! Position L0.0 P3.0 H6.0 mm ! Rotation 90.00 deg ! A >> P 208 mm ! R >> L 180 mm ! F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 ExcitWEns 0 1H 36.889 V Gain Low Table position 0 mm Img. Scale. Cor. 5.000 Physio 1st Signal/Mode None Magn. preparation Non-sel. IR TI 1000 ms Dark blood Off Resp. control Off Inline Distortion correction Off Sequence Introduction On Dimension 3D Elliptical scanning Off Averaging mode Long term Multi-slice mode Single shot Reordering Linear Asymmetric echo Allowed Bandwidth 210 Hz/Px Flow comp. No Echo spacing 7.5 ms Turbo factor 256 RF pulse type Fast Gradient mode Fast Excitation Non-sel. RF spoiling On TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms Mode Off BOLD Subtract Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices

26

Page 27: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On Distortion Corr. Off Save original images On Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\T2w_SPC TA:5:57 PAT:2 Voxel size:0.8x0.8x0.8 mm Rel. SNR:1.00 :spc ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slab groups 1 Slabs 1 Position Isocenter Orientation Sagittal Phase enc. dir. A >> P AutoAlign Head > Brain Phase oversampling 0 % Slice oversampling 0.0 % FoV read 256 mm FoV phase 93.8 % Slice thickness 0.80 mm TR 3200 ms TE 563.0 ms Concatenations 1 Filter Prescan Normalize Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Fat suppr. None Water suppr. None Restore magn. Off

27

Page 28: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Measurements 1 Reconstruction Magnitude Multiple series Each measurement Resolution Base resolution 320 Phase resolution 100 % Phase partial Fourier Allowed Interpolation Off PAT mode GRAPPA Accel. factor PE 2 Ref. lines PE 32 Reference scan mode Integrated Image Filter Off Distortion Corr. Off Accel. factor 3D 1 Unfiltered images On Prescan Normalize On Normalize Off B1 filter Off Raw filter Off Elliptical filter Off Slice resolution 100 % Slice partial Fourier Off Geometry Nr. of slab groups 1 Slabs 1 Position Isocenter Phase enc. dir. A >> P Phase oversampling 0 % Slice oversampling 0.0 % Slices per slab 208 Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Water suppr. None Special sat. None Special sat. None Table position P Restore magn. Off System Body Off HEP On HEA On Position mode L-P-H Positioning mode FIX Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Adaptive Combine AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off

28

Page 29: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V ! Position L0.0 P3.0 H6.0 mm ! Rotation 90.00 deg ! A >> P 208 mm ! R >> L 180 mm ! F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 SRFExcit 1H 138.333 V ! Gain High Table position 0 mm Img. Scale. Cor. 5.000 Physio 1st Signal/Mode None Trigger delay 0 ms Magn. preparation None Dark blood Off Resp. control Off Inline Distortion correction Off Sequence Introduction On Dimension 3D Elliptical scanning Off Reordering Linear Bandwidth 744 Hz/Px Flow comp. No Allowed delay 0 s Echo spacing 3.43 ms Adiabatic-mode Off Turbo factor 314 Echo train duration 1074 RF pulse type Fast Gradient mode Fast Excitation Non-sel. Flip angle mode T2 var TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms Organ under exam. None BOLD Subtract Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off

29

Page 30: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

MIP-Time Off Radial MIP Off Save original images On Distortion Corr. Off Save original images On Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\SpinEchoFieldMap_RL TA:0:28 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 7080 ms TE 58.0 ms Multi-band accel. factor 1 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 90 deg Fat suppr. Fat sat. Grad. rev. fat suppr. Disabled Averaging mode Long term Measurements 3 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 %

30

Page 31: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Grad. rev. fat suppr. Disabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 AddCSaCSatNS 1H 40.921 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None

31

Page 32: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 RF pulse type Normal Gradient mode Fast Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states Off Temp. highpass filter Off Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\SpinEchoFieldMap_LR TA:0:28 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 %

32

Page 33: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Slice thickness 2.00 mm TR 7080 ms TE 58.0 ms Multi-band accel. factor 1 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 90 deg Fat suppr. Fat sat. Grad. rev. fat suppr. Disabled Averaging mode Long term Measurements 3 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Grad. rev. fat suppr. Disabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard

33

Page 34: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 AddCSaCSatNS 1H 40.921 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 RF pulse type Normal Gradient mode Fast Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states Off Temp. highpass filter Off Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\rfMRI_REST_RL TA:5:12 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement

34

Page 35: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 420 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None

35

Page 36: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0

36

Page 37: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\rfMRI_REST_LR TA:5:12 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 420 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None

37

Page 38: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off

38

Page 39: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\tfMRI_WM_RL TA:5:01 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8

39

Page 40: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 405 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V

40

Page 41: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\tfMRI_WM_LR TA:5:01 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off

41

Page 42: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 405 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On

42

Page 43: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off

43

Page 44: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\tfMRI_EMOTION_RL TA:2:33 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 199 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry

44

Page 45: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast

45

Page 46: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\tfMRI_EMOTION_LR TA:2:33 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg

46

Page 47: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Fat suppr. Fat sat. Averaging mode Long term Measurements 199 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz

47

Page 48: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\T1w_vNav_3e TA:9:40 PAT:2 Voxel size:0.8x0.8x0.8 mm Rel. SNR:1.00 :tfl ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slab groups 1 Slabs 1

48

Page 49: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Dist. factor 50 % Position Isocenter Orientation Sagittal Phase enc. dir. A >> P AutoAlign Head > Brain Phase oversampling 0 % Slice oversampling 0.0 % FoV read 256 mm FoV phase 100.0 % Slice thickness 0.80 mm TR 2400.0 ms TE 1 1.66 ms Averages 1 Concatenations 1 Filter Prescan Normalize Coil elements HEA;HEP Contrast Magn. preparation Non-sel. IR TI 1300 ms Flip angle 1 8.0 deg Fat suppr. Water excit. fast Water suppr. None Averaging mode Long term Measurements 1 Reconstruction Magnitude Multiple series Each measurement Resolution Base resolution 320 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode GRAPPA Accel. factor PE 2 Ref. lines PE 32 Reference scan mode Integrated Image Filter Off Distortion Corr. Off Accel. factor 3D 1 Unfiltered images On Prescan Normalize On Normalize Off B1 filter Off Raw filter Off Elliptical filter Off Slice resolution 100 % Slice partial Fourier Off Geometry Nr. of slab groups 1 Slabs 1 Dist. factor 50 % Position Isocenter Phase enc. dir. A >> P Phase oversampling 0 % Slice oversampling 0.0 % Slices per slab 208 Multi-slice mode Single shot Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Base size phase 256 mm

49

Page 50: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Base size read 256 mm Fat suppr. Water excit. fast Water suppr. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode FIX Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Adaptive Combine AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V ! Position L0.0 P3.0 H6.0 mm ! Rotation 90.00 deg ! A >> P 208 mm ! R >> L 180 mm ! F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 ExcitWEns 0 1H 36.889 V Gain Low Table position 0 mm Img. Scale. Cor. 5.000 Physio Magn. preparation Non-sel. IR TI 1300 msInline Distortion correction Off Sequence Introduction On Dimension 3D Elliptical scanning Off Averaging mode Long term Multi-slice mode Single shot Reordering Linear Asymmetric echo Off Contrasts 3 Bandwidth 1 740 Hz/Px Flow comp. 1 No Echo spacing 8.8 ms Turbo factor 208 RF pulse type Fast Gradient mode Fast Excitation Non-sel.

50

Page 51: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

RF spoiling On Readout polarity Positive Apply moco to parent and nav Remeasure 60 TRs Feedback Delay 108 ms Moco Ref. Image Use Temp Ref Add. grad time 0.0 ms Apply freq to parent and nav Averaging RMS TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms Mode Off BOLD Subtract Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On Distortion Corr. Off Contrasts 3 Save original images On Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\Localizer TA:9.2 s PAT:Off Voxel size:1.2x1.2x5.0 mm Rel. SNR:1.00 :fl ---------------------------------------------------------------------------------Properties Prio Recon On Before measurement After measurement Load to viewer Off Inline movie Off Auto store images On Load to stamp segments On Load images to graphic segments On Auto open inline display Off Wait for user to start On

51

Page 52: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Start measurements single Routine Nr. of slice groups 3 Slices 1 Dist. factor 20 % Position L0.0 A45.0 H0.0 mm Orientation Transversal Phase enc. dir. A >> P AutoAlign --- Phase oversampling 0 % FoV read 300 mm FoV phase 100.0 % Slice thickness 5.0 mm TR 40.0 ms TE 3.00 ms Averages 1 Concatenations 1 Filter Prescan Normalize, Elliptical filter Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 15 deg Fat suppr. None Water suppr. None SWI Off Averaging mode Short term Measurements 1 Reconstruction Magnitude Multiple series Off Resolution Base resolution 256 Phase resolution 75 % Phase partial Fourier Off Interpolation Off PAT mode None Image Filter Off Distortion Corr. Off Unfiltered images Off Prescan Normalize On Normalize Off B1 filter Off Raw filter Off Elliptical filter On Mode Inplane Geometry Nr. of slice groups 3 Slices 1 Dist. factor 20 % Position L0.0 A45.0 H0.0 mm Phase enc. dir. A >> P Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Saturation mode Standard Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Water suppr. None Special sat. None

52

Page 53: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Sum of Squares AutoAlign --- Auto Coil Select Default Shim mode Tune up Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position Isocenter Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm Frequency 1H 123.253687 MHz Correction factor 1 SRFExcit 1H 19.740 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Segments 1 Magn. preparation None Dark blood Off Resp. control Off Inline Distortion correction Off Sequence Introduction On Dimension 2D Phase stabilisation On Averaging mode Short term Multi-slice mode Interleaved Asymmetric echo Allowed Contrasts 1 Bandwidth 260 Hz/Px Flow comp. No Allowed delay 0 s RF pulse type Normal Gradient mode Fast Excitation Slice-sel. RF spoiling On TX/RX delta frequency 0 Hz

53

Page 54: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms Mode Off BOLD Subtract Off Liver registration Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On Distortion Corr. Off Contrasts 1 Save original images On Wash - In Off Wash - Out Off TTP Off PEI Off MIP - time Off Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\AAHScout TA:0:14 PAT:3 Voxel size:1.6x1.6x1.6 mm Rel. SNR:1.00 :fl ---------------------------------------------------------------------------------Properties Prio Recon On Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slab groups 1 Slabs 1

54

Page 55: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Dist. factor 20 % Position L0.0 A45.0 H0.0 mm Orientation Sagittal Phase enc. dir. A >> P Phase oversampling 0 % Slice oversampling 0.0 % FoV read 260 mm FoV phase 100.0 % Slice thickness 1.6 mm TR 3.15 ms TE 1.37 ms Averages 1 Concatenations 1 Filter Prescan Normalize Coil elements HEA;HEP AutoAlign Head Contrast Flip angle 8 deg Averaging mode Short term Measurements 1 Reconstruction Magnitude Resolution Base resolution 160 Phase resolution 100 % Phase partial Fourier 6/8 PAT mode GRAPPA Accel. factor PE 3 Ref. lines PE 24 Reference scan mode Integrated Image Filter Off Distortion Corr. Off Accel. factor 3D 1 Unfiltered images Off Prescan Normalize On Normalize Off B1 filter Off Raw filter Off Elliptical filter Off Slice resolution 69 % Slice partial Fourier 6/8 Geometry Nr. of slab groups 1 Slabs 1 Dist. factor 20 % Position L0.0 A45.0 H0.0 mm Phase enc. dir. A >> P Phase oversampling 0 % Slice oversampling 0.0 % Slices per slab 128 Multi-slice mode Sequential Series Ascending Nr. of sat. regions 0 Position mode L-P-H Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H

55

Page 56: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Adaptive Combine Auto Coil Select Off Shim mode Tune up Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position Isocenter Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm Frequency 1H 123.253687 MHz Correction factor 1 SRFExcit 1H 24.593 V Gain Low Table position 0 mm Img. Scale. Cor. 1.000 PhysioInline Distortion correction Off Sequence Introduction On Dimension 3D Averaging mode Short term Multi-slice mode Sequential Asymmetric echo Weak Contrasts 1 Bandwidth 540 Hz/Px RF pulse type Fast Gradient mode Normal Excitation Non-sel. RF spoiling On TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms Mode Off BOLD Time to center 6.2 s Subtract Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices StdDev Off Std-Dev-Sag Off

56

Page 57: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On Distortion Corr. Off Contrasts 1 Save original images On Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\Localizer_aligned TA:0:22 PAT:Off Voxel size:1.2x1.2x5.0 mm Rel. SNR:1.00 :fl ---------------------------------------------------------------------------------Properties Prio Recon On Before measurement After measurement Load to viewer Off Inline movie Off Auto store images On Load to stamp segments On Load images to graphic segments On Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slice groups 3 Slices 1 Dist. factor 20 % Position Isocenter Orientation Transversal Phase enc. dir. A >> P AutoAlign Head > Brain Phase oversampling 0 % FoV read 300 mm FoV phase 100.0 % Slice thickness 5.0 mm TR 104.0 ms TE 3.00 ms Averages 1 Concatenations 1 Filter Prescan Normalize, Elliptical filter Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 15 deg Fat suppr. None Water suppr. None

57

Page 58: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

SWI Off Averaging mode Short term Measurements 1 Reconstruction Magnitude Multiple series Off Resolution Base resolution 256 Phase resolution 75 % Phase partial Fourier Off Interpolation Off PAT mode None Image Filter Off Distortion Corr. Off Unfiltered images Off Prescan Normalize On Normalize Off B1 filter Off Raw filter Off Elliptical filter On Mode Inplane Geometry Nr. of slice groups 3 Slices 1 Dist. factor 20 % Position Isocenter Phase enc. dir. A >> P Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Saturation mode Standard Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Water suppr. None Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Tune up Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V

58

Page 59: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Position Isocenter Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm Frequency 1H 123.253687 MHz Correction factor 1 SRFExcit 1H 19.740 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Segments 1 Magn. preparation None Dark blood Off Resp. control Off Inline Distortion correction Off Sequence Introduction On Dimension 2D Phase stabilisation On Averaging mode Short term Multi-slice mode Interleaved Asymmetric echo Allowed Contrasts 1 Bandwidth 260 Hz/Px Flow comp. No Allowed delay 0 s RF pulse type Normal Gradient mode Fast Excitation Slice-sel. RF spoiling On TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms Mode Off BOLD Subtract Off Liver registration Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On

59

Page 60: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Distortion Corr. Off Contrasts 1 Save original images On Wash - In Off Wash - Out Off TTP Off PEI Off MIP - time Off Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\BIAS_BC TA:0:26 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :tfl ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slab groups 1 Slabs 1 Dist. factor 50 % Position Isocenter Orientation Sagittal Phase enc. dir. A >> P AutoAlign Head > Brain Phase oversampling 0 % Slice oversampling 18.2 % FoV read 256 mm FoV phase 100.0 % Slice thickness 2.00 mm TR 250.0 ms TE 1.01 ms Averages 1 Concatenations 1 Filter None Coil elements BC Contrast Magn. preparation None Flip angle 3 deg Fat suppr. None Water suppr. None Averaging mode Long term Measurements 1 Reconstruction Magnitude Multiple series Each measurement

60

Page 61: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Resolution Base resolution 128 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation Off PAT mode None Image Filter Off Distortion Corr. Off Prescan Normalize Off Normalize Off B1 filter Off Raw filter Off Elliptical filter Off Slice resolution 100 % Slice partial Fourier 6/8 Geometry Nr. of slab groups 1 Slabs 1 Dist. factor 50 % Position Isocenter Phase enc. dir. A >> P Phase oversampling 0 % Slice oversampling 18.2 % Slices per slab 88 Multi-slice mode Single shot Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Water suppr. None Special sat. None Table position P System Body On HEP Off HEA Off Position mode L-P-H Positioning mode FIX Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Tune up Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position Isocenter Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm

61

Page 62: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Frequency 1H 123.253687 MHz Correction factor 1 SRFExcit 1H 27.667 V Gain Low Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Dark blood Off Resp. control Off Inline Distortion correction Off Sequence Introduction On Dimension 3D Elliptical scanning Off Averaging mode Long term Multi-slice mode Single shot Reordering Linear Asymmetric echo Allowed Bandwidth 540 Hz/Px Flow comp. No Echo spacing 3 ms Turbo factor 78 RF pulse type Fast Gradient mode Fast Excitation Non-sel. RF spoiling On TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements BC Acquisition duration 0 ms Mode Off BOLD Subtract Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On Distortion Corr. Off Save original images On Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off

62

Page 63: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\BIAS_32CH TA:0:26 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :tfl ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slab groups 1 Slabs 1 Dist. factor 50 % Position Isocenter Orientation Sagittal Phase enc. dir. A >> P AutoAlign Head > Brain Phase oversampling 0 % Slice oversampling 18.2 % FoV read 256 mm FoV phase 100.0 % Slice thickness 2.00 mm TR 250.0 ms TE 1.01 ms Averages 1 Concatenations 1 Filter None Coil elements HEA;HEP Contrast Magn. preparation None Flip angle 3 deg Fat suppr. None Water suppr. None Averaging mode Long term Measurements 1 Reconstruction Magnitude Multiple series Each measurement Resolution Base resolution 128 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation Off PAT mode None Image Filter Off Distortion Corr. Off Prescan Normalize Off Normalize Off B1 filter Off Raw filter Off

63

Page 64: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Elliptical filter Off Slice resolution 100 % Slice partial Fourier 6/8 Geometry Nr. of slab groups 1 Slabs 1 Dist. factor 50 % Position Isocenter Phase enc. dir. A >> P Phase oversampling 0 % Slice oversampling 18.2 % Slices per slab 88 Multi-slice mode Single shot Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Water suppr. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode FIX Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Save uncombined Off Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Tune up Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position Isocenter Rotation 0.00 deg R >> L 350 mm A >> P 263 mm F >> H 350 mm Frequency 1H 123.253687 MHz Correction factor 1 SRFExcit 1H 27.667 V Gain Low Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Dark blood Off Resp. control Off Inline

64

Page 65: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Distortion correction Off Sequence Introduction On Dimension 3D Elliptical scanning Off Averaging mode Long term Multi-slice mode Single shot Reordering Linear Asymmetric echo Allowed Bandwidth 540 Hz/Px Flow comp. No Echo spacing 3 ms Turbo factor 78 RF pulse type Fast Gradient mode Fast Excitation Non-sel. RF spoiling On TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms Mode Off BOLD Subtract Off Save images On Autoscaling Off Scaling factor 1 Offset 0 Subtrahend 1 Subtraction indices StdDev Off Std-Dev-Sag Off Std-Dev-Cor Off Std-Dev-Tra Off Std-Dev-Time Off MIP-Sag Off MIP-Cor Off MIP-Tra Off MIP-Time Off Radial MIP Off Save original images On Distortion Corr. Off Save original images On Number of radial views 1 Axis of radial views L-R MPR Sag Off MPR Cor Off MPR Tra Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\SpinEchoFieldMap_RL TA:0:28 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement

65

Page 66: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 7080 ms TE 58.0 ms Multi-band accel. factor 1 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 90 deg Fat suppr. Fat sat. Grad. rev. fat suppr. Disabled Averaging mode Long term Measurements 3 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None

66

Page 67: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Grad. rev. fat suppr. Disabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 AddCSaCSatNS 1H 40.921 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 RF pulse type Normal Gradient mode Fast Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0

67

Page 68: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Ignore after transition 0 Model transition states Off Temp. highpass filter Off Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\SpinEchoFieldMap_LR TA:0:28 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 7080 ms TE 58.0 ms Multi-band accel. factor 1 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 90 deg Fat suppr. Fat sat. Grad. rev. fat suppr. Disabled Averaging mode Long term Measurements 3 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off

68

Page 69: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Grad. rev. fat suppr. Disabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 AddCSaCSatNS 1H 40.921 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline

69

Page 70: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 RF pulse type Normal Gradient mode Fast Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states Off Temp. highpass filter Off Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\rfMRI_REST_LR TA:5:12 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm

70

Page 71: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 420 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off

71

Page 72: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\rfMRI_REST_RL TA:5:12 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off

72

Page 73: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 420 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System

73

Page 74: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00

74

Page 75: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\DWI_dir79_RL TA:5:11 PAT:Off Voxel size:1.5x1.5x1.5 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 93 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 210 mm FoV phase 85.7 % Slice thickness 1.50 mm TR 3730 ms TE 76.60 ms Multi-band accel. factor 3 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 78 deg Fat suppr. None Grad. rev. fat suppr. Enabled Averaging mode Long term Measurements 1 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 140 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation Off PAT mode None Distortion Corr. Off Prescan Normalize Off

75

Page 76: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Raw filter Off Elliptical filter Off Dynamic Field Corr. Off Geometry Nr. of slice groups 1 Slices 93 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Special sat. None Grad. rev. fat suppr. Enabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode FIX Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 210 mm R >> L 180 mm F >> H 140 mm Frequency 1H 123.253687 MHz Correction factor 1 ExtExciteRF 1H 85.623 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Resp. control Off Inline Distortion correction Off Sequence Introduction On

76

Page 77: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Averaging mode Long term Multi-slice mode Interleaved Bandwidth 1700 Hz/Px Echo spacing 0.69 ms EPI factor 120 Gradient mode Fast Online multi-band recon. Remote TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD Delay in TR 0 ms Diffusion mode Free Diff. weightings 1 b-value 3000 s/mm² Diff. weighted images On Trace weighted images Off ADC maps Off FA maps Off Mosaic On Tensor Off Distortion Corr. Off b-Value >= 0 s/mm² Exponential ADC Maps Off Invert Gray Scale Off Calculated Image Off Calculated bValue 1400 s/mm²

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\DWI_dir79_LR TA:5:11 PAT:Off Voxel size:1.5x1.5x1.5 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 93 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 210 mm FoV phase 85.7 % Slice thickness 1.50 mm

77

Page 78: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

TR 3730 ms TE 76.60 ms Multi-band accel. factor 3 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 78 deg Fat suppr. None Grad. rev. fat suppr. Enabled Averaging mode Long term Measurements 1 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 140 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation Off PAT mode None Distortion Corr. Off Prescan Normalize Off Raw filter Off Elliptical filter Off Dynamic Field Corr. Off Geometry Nr. of slice groups 1 Slices 93 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Special sat. None Grad. rev. fat suppr. Enabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode FIX Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off

78

Page 79: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 210 mm R >> L 180 mm F >> H 140 mm Frequency 1H 123.253687 MHz Correction factor 1 ExtExciteRF 1H 85.623 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Resp. control Off Inline Distortion correction Off Sequence Introduction On Averaging mode Long term Multi-slice mode Interleaved Bandwidth 1700 Hz/Px Echo spacing 0.69 ms EPI factor 120 Gradient mode Fast Online multi-band recon. Remote TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD Delay in TR 0 ms Diffusion mode Free Diff. weightings 1 b-value 3000 s/mm² Diff. weighted images On Trace weighted images Off ADC maps Off FA maps Off Mosaic On Tensor Off Distortion Corr. Off b-Value >= 0 s/mm² Exponential ADC Maps Off Invert Gray Scale Off Calculated Image Off Calculated bValue 1400 s/mm²

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\DWI_dir84_RL TA:5:30 PAT:Off Voxel size:1.5x1.5x1.5 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------

79

Page 80: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 93 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 210 mm FoV phase 85.7 % Slice thickness 1.50 mm TR 3730 ms TE 76.60 ms Multi-band accel. factor 3 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 78 deg Fat suppr. None Grad. rev. fat suppr. Enabled Averaging mode Long term Measurements 1 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 140 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation Off PAT mode None Distortion Corr. Off Prescan Normalize Off Raw filter Off Elliptical filter Off Dynamic Field Corr. Off Geometry Nr. of slice groups 1 Slices 93 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved

80

Page 81: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Special sat. None Grad. rev. fat suppr. Enabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode FIX Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 210 mm R >> L 180 mm F >> H 140 mm Frequency 1H 123.253687 MHz Correction factor 1 ExtExciteRF 1H 85.623 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Resp. control Off Inline Distortion correction Off Sequence Introduction On Averaging mode Long term Multi-slice mode Interleaved Bandwidth 1700 Hz/Px Echo spacing 0.69 ms EPI factor 120 Gradient mode Fast Online multi-band recon. Remote TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 ms

81

Page 82: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

BOLD Delay in TR 0 ms Diffusion mode Free Diff. weightings 1 b-value 3000 s/mm² Diff. weighted images On Trace weighted images Off ADC maps Off FA maps Off Mosaic On Tensor Off Distortion Corr. Off b-Value >= 0 s/mm² Exponential ADC Maps Off Invert Gray Scale Off Calculated Image Off Calculated bValue 1400 s/mm²

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\DWI_dir84_LR TA:5:30 PAT:Off Voxel size:1.5x1.5x1.5 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 93 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 210 mm FoV phase 85.7 % Slice thickness 1.50 mm TR 3730 ms TE 76.60 ms Multi-band accel. factor 3 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 78 deg Fat suppr. None Grad. rev. fat suppr. Enabled Averaging mode Long term

82

Page 83: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Measurements 1 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 140 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation Off PAT mode None Distortion Corr. Off Prescan Normalize Off Raw filter Off Elliptical filter Off Dynamic Field Corr. Off Geometry Nr. of slice groups 1 Slices 93 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. None Special sat. None Grad. rev. fat suppr. Enabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode FIX Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 210 mm R >> L 180 mm F >> H 140 mm Frequency 1H 123.253687 MHz Correction factor 1

83

Page 84: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

ExtExciteRF 1H 85.623 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Resp. control Off Inline Distortion correction Off Sequence Introduction On Averaging mode Long term Multi-slice mode Interleaved Bandwidth 1700 Hz/Px Echo spacing 0.69 ms EPI factor 120 Gradient mode Fast Online multi-band recon. Remote TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD Delay in TR 0 ms Diffusion mode Free Diff. weightings 1 b-value 3000 s/mm² Diff. weighted images On Trace weighted images Off ADC maps Off FA maps Off Mosaic On Tensor Off Distortion Corr. Off b-Value >= 0 s/mm² Exponential ADC Maps Off Invert Gray Scale Off Calculated Image Off Calculated bValue 1400 s/mm²

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\SpinEchoFieldMap_RL TA:0:28 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single

84

Page 85: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 7080 ms TE 58.0 ms Multi-band accel. factor 1 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 90 deg Fat suppr. Fat sat. Grad. rev. fat suppr. Disabled Averaging mode Long term Measurements 3 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Grad. rev. fat suppr. Disabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H

85

Page 86: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 AddCSaCSatNS 1H 40.921 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 RF pulse type Normal Gradient mode Fast Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states Off Temp. highpass filter Off Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms

86

Page 87: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\SpinEchoFieldMap_LR TA:0:28 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epse ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start Off Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 7080 ms TE 58.0 ms Multi-band accel. factor 1 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 90 deg Fat suppr. Fat sat. Grad. rev. fat suppr. Disabled Averaging mode Long term Measurements 3 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry

87

Page 88: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Grad. rev. fat suppr. Disabled Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 AddCSaCSatNS 1H 40.921 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90

88

Page 89: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

RF pulse type Normal Gradient mode Fast Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states Off Temp. highpass filter Off Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\rfMRI_REST_LR TA:5:12 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None

89

Page 90: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 420 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm

90

Page 91: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\rfMRI_REST_RL TA:5:12 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1

91

Page 92: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 420 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T

92

Page 93: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11

93

Page 94: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\tfMRI_SOCIAL_RL TA:3:27 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 274 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L

94

Page 95: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz

95

Page 96: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\tfMRI_SOCIAL_LR TA:3:27 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 274 Delay in TR 0 ms Reconstruction Magnitude

96

Page 97: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000

97

Page 98: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\tfMRI_GAMBLING_RL TA:3:11 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain

98

Page 99: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 253 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat. Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default

99

Page 100: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0 Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11--------------------------------------------------------------------------------- \\USER\Lifespan\LS_Phase1b_14-55yo\SessionB\tfMRI_GAMBLING_LR TA:3:11 PAT:Off Voxel size:2.0x2.0x2.0 mm Rel. SNR:1.00 :epfid ---------------------------------------------------------------------------------Properties Prio Recon Off

100

Page 101: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Before measurement After measurement Load to viewer On Inline movie Off Auto store images On Load to stamp segments Off Load images to graphic segments Off Auto open inline display Off Wait for user to start On Start measurements single Routine Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Orientation T > C-20.0 Phase enc. dir. R >> L AutoAlign Head > Brain Phase oversampling 0 % FoV read 208 mm FoV phase 86.5 % Slice thickness 2.00 mm TR 720 ms TE 33.20 ms Multi-band accel. factor 8 Filter None Coil elements HEA;HEP Contrast MTC Off Magn. preparation None Flip angle 52 deg Fat suppr. Fat sat. Averaging mode Long term Measurements 253 Delay in TR 0 ms Reconstruction Magnitude Multiple series Off Resolution Base resolution 104 Phase resolution 100 % Phase partial Fourier Off Interpolation Off PAT mode None Distortion Corr. Off Hamming Off Prescan Normalize Off Raw filter Off Elliptical filter Off Geometry Nr. of slice groups 1 Slices 72 Dist. factor 0 % Position L0.0 P3.0 H6.0 mm Phase enc. dir. R >> L Phase oversampling 0 % Multi-slice mode Interleaved Series Interleaved Nr. of sat. regions 0 Position mode L-P-H Fat suppr. Fat sat.

101

Page 102: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Special sat. None Special sat. None Table position P System Body Off HEP On HEA On Position mode L-P-H Positioning mode REF Table position H Table position 0 mm MSMA S - C - T Sagittal R >> L Coronal A >> P Transversal F >> H Coil Combine Mode Sum of Squares AutoAlign Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Off Confirm freq. adjustment Off Assume Dominant Fat Off Assume Silicone Off Adjustment Tolerance Auto ? Ref. amplitude 1H 0.000 V Position L0.0 P3.0 H6.0 mm Rotation 90.00 deg A >> P 208 mm R >> L 180 mm F >> H 144 mm Frequency 1H 123.253687 MHz Correction factor 1 MBExc 1H 280.027 V Gain High Table position 0 mm Img. Scale. Cor. 1.000 Physio 1st Signal/Mode None Magn. preparation None Inline Distortion correction Off Sequence Introduction Off Averaging mode Long term Multi-slice mode Interleaved Bandwidth 2290 Hz/Px Echo spacing 0.58 ms EPI factor 90 Gradient mode Fast Online multi-band recon. Remote Triggering scheme Standard TX/RX delta frequency 0 Hz TX Nucleus None TX delta frequency 0 Hz Coil elements HEA;HEP Acquisition duration 0 msBOLD GLM Statistics Off Dynamic t-maps Off Starting ignore meas 0

102

Page 103: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

Ignore after transition 0 Model transition states On Temp. highpass filter On Threshold 4.00 Paradigm size 3 Motion correction Off Spatial filter Off Delay in TR 0 ms Distortion Corr. Off

SIEMENS MAGNETOM ConnectomS syngo MR D11

--------------------------------------------------------------------------------- Table Of Contents---------------------------------------------------------------------------------

\\USER |Lifespan | |LS_Phase1b_14-55yo | | |SessionA | | | |Localizer | | | |AAHScout | | | |Localizer_aligned | | | |BIAS_BC | | | |BIAS_32CH | | | |SpinEchoFieldMap_RL | | | |SpinEchoFieldMap_LR | | | |rfMRI_REST_RL | | | |rfMRI_REST_LR | | | |T1w_MPR | | | |T2w_SPC | | | |SpinEchoFieldMap_RL | | | |SpinEchoFieldMap_LR | | | |rfMRI_REST_RL | | | |rfMRI_REST_LR | | | |tfMRI_WM_RL | | | |tfMRI_WM_LR | | | |tfMRI_EMOTION_RL | | | |tfMRI_EMOTION_LR | | | |T1w_vNav_3e | | |SessionB | | | |Localizer | | | |AAHScout | | | |Localizer_aligned | | | |BIAS_BC | | | |BIAS_32CH | | | |SpinEchoFieldMap_RL | | | |SpinEchoFieldMap_LR | | | |rfMRI_REST_LR | | | |rfMRI_REST_RL | | | |DWI_dir79_RL | | | |DWI_dir79_LR | | | |DWI_dir84_RL | | | |DWI_dir84_LR | | | |SpinEchoFieldMap_RL | | | |SpinEchoFieldMap_LR | | | |rfMRI_REST_LR | | | |rfMRI_REST_RL | | | |tfMRI_SOCIAL_RL

103

Page 104: SIEMENS MAGNETOM ConnectomS syngo MR D11...2014/06/12  · SIEMENS MAGNETOM ConnectomS syngo MR D11-----\\USER\Lifespan\LS_Phase1b_14-55yo\SessionA\Localizer TA:9.2 s PAT:Off Voxel

| | | |tfMRI_SOCIAL_LR | | | |tfMRI_GAMBLING_RL | | | |tfMRI_GAMBLING_LR

104