A D D R E S S A B L E F I R E D E T E C T I O N
& A L A R M S Y S T E M S
June 2000 supersedes January 2000
8000system
@we look @ bus iness di f ferent ly
.
.
.
.
7/30/2019 System 8000
2/10
S Y S T E M A R C H I T E C T U R E
Sensor
Beam Detector
Slave LED(mimics LED of
next device)
ConventionalFire Alarm
System
ExternalDevices
Optic FibreMax. 1 km
Max. 1km Max. 1km
Call Point
Non FireApplication
eg.Fire Exits
Printer
Sounders Mimic
9200 DetectorSeries
Repeat
Indicator
4 Zone,2 Relay
Transponder
1 ZoneTransponder
9000 ConventionalDetector Series
GraphicsDisplay
ExternalDevices
ExternalDevices
ExternalDevices
ExternalDevices
Network up to 31 panels
Up to 7loops
per panel
Booster(to increasedistancesbetweenpanels)
SounderController
32 LED OutputsTransponder
8000 Fire AlarmControl Panel
Note: 1). Max. 127 devices per loop, 512 devices per panel. 2). Maximum loop length is 1km.
3). This schematic is for guidance only please refer to product instructions during installation.
7/30/2019 System 8000
3/10
8 0 0 0 F E A T U R E S & B E N E F I T S
Powerful Commissioning and Servicing Tools
A comprehensive suite of tools to support the commissioning,
installation and maintenance of the system. This includesremote access for interrogation and service via a modem,
wiring integrity checks and fireplan simulation.
Multicriteria Sensing
The multicriteria sensor detects fire in 3 different ways (Optical/Heat/Ion). Diagnosis is therefore more accurate than any singlemethod of detection.
Create Seamless Networks
Connect up to 31 panels together and retain control on largeor complex sites. Also, new buildings or extensions are easilyaccommodated on the existing system.
Clear User Information
Display information is customised to the site requirements.Messages and actions are clear and understandable to the user.
Flexible Alarm Settings
Sounder circuits are run off transponders on the panel loop.This saves money over conventional sounder wiring andallows flexibility since each circuit may be programmed to
sound individually in the event of an alarm.
Disable Button for Weekly Test
BS 5839 calls for weekly testing of the fire alarm system.Outputs to critical plant such as boiler controls however canbe disabled simply without affecting the general test.
Timed Solutions
Detector functions can be switched on or off at varying timesto suit the buildings use. For instance, a detector could operateas a heat detector during periods when the building is occupiedthen as a smoke, ionisation and heat detector when no one ispresent to spot smoke.
Flexible Input and Output Features
System 8000 has flexible fire and non-fire switching capabilitiese.g. fire exits may be monitored. Opening such an exit couldbe registered at the control panel or activate a beacon output toalert staff.
7/30/2019 System 8000
4/10
T E L E - D I A G N O S T I C P R O G R A M ( T E D I S )
Interrogate, diagnose and rectify problems on the fire system without having to be present on site.
Tedis allows an engineer to interrogate, diagnose and rectify problems on the firesystem without having to be present on site. Using a PC and modem the engineer candial into the control panel from any location even while on the move. Status
identification and modification of the following are easily achieved;
All control panel data Operation
Loop device data Fault finding & rectification
All customer specific configurations
This advance knowledge assists the engineer to arrive on site fully prepared with therequired materials, manpower and tools to complete the work first time. Tedis can alsobe used to provide remote assistance to a user over the telephone.
TEDIS
7/30/2019 System 8000
5/10
Dimensions (mm)
8 0 0 0 C O N T R O L P A N E L8 0 0 0 C O N T R O L P A N E L
The 8000 control panel and devices aredesigned to offer an affordable solutionto the protection of buildings withcomplex fire safety needs. A text displaycombined with LED indicators willclearly pinpoint a fire or fault condition.
An historic log remembers the latest 200events and there are printer and zonaldisplay options. Panels comply with BSEN54 and are compatible with therequirements of BS 5839 part 1. Theyare approved by the demanding VdS test-ing authority and LPC approval is
applied for.
450 179
206
320
320
MountingBox
MountingBox
8000 Control Panel
Technical Specification - Control Panel
Mains voltage 230 V/ 50-60 Hz
Power supply unit 12 V / 3.5 A
Operating voltage 9 - 19 VDC
Quiescent current consumption max. 150 mA
Emergency power supply 12V, 2 x 12 Ah (2 x 24 Ah in extension housing)
Operating temperature 0 C to 50 C
Weight appr. 6.5 kg (Without batteries)
Ingress Protection IP 30
Max Number of loops per panel 7
Standby period 24hrs + 30minutes alarm, upgradeable to 72 hours
Extensionhousing for
2 x 12V / 24Ahbatteries(optional)
ORDER CODES
1 Loop 788111
1 Loop c/w 788112Zone Indication
1 Loop c/w Printer 788113
2 Loop 788104
2 Loop c/w 788105Zone Indication
2 Loop c/w Printer 788106
All units supplied with 1 loop card.
For customised versions see backcover.
The control panel has aunique bypass circuit. Ina catastrophic eventsuch as a lightning strike
damaging the micro-processor, the panel willswitch to a 2 statesystem and continue toprovide detection forthe building and itsoccupants.
S P E C I A L F E AT U R E
7/30/2019 System 8000
6/10
Volumatic Sensors
Beam Duct
Quiescent Current Receiver 8mA 45
Transmitter 5mA
Approximate Weight 3.2Kg 700g
Ingress Protection IP30 IP54
Applicable Standard BS 5839 Part 5 BS EN54
Operating Temperature -20 to +55C -20 to +60C
Beam Length 10 - 100m N/A
Approvals N/A LPCB
Dimensions (mm) Controller 120W x 110H x 300D210W x 260H x145D
Order Code 07011-41 Housing 781453
Venturi Tube 0.6m 781456
Venturi Tube 1.5m 781457
Venturi Tube 2.8m 781458
8 0 0 0 O U T S T A T I O N S
Sensors
Ionisation Fixed Temperature Rate of rise Optical OT Multisensor OTI MultisensorHeat Heat
Quiescent Current 45A 45A 45A 45A 45A 45A
Approximate Weight 100g 100g 100g 100g 100g 100g
Ingress Protection IP40 IP40 IP40 IP40 IP40 IP40
Applicable Standard BS EN54, Pt 7 BS EN54, Pt 5 BS EN54, Pt 5 BS EN54, Pt 7 BS EN54,Pt 7 BS EN54, Pt 5or7
Operating -20 to +60C -20 to +72C 54 to 62C, 1C/min -20 to +72C -20 to +72C -20 to +72C
Temperature45 to 64C, 5C/min
32 to 72C, 30C/min
Approvals* VdS VdS VdS VdS VdS VdS
Dimensions (mm) 90 dia x 61 90 dia x 61 90 dia x 61 90 dia x 61 90 dia x 61 90 dia x 61
Order Codes 761071 761171 761271 761371 761373 761973
* LPC pending. Contact Gent 24 for details.
All sensors carry aunique serial number forbackwards traceability.It is therefore possibleto see a complete log ofevents for a particular
device such as when itwas last reworked,cleaned or how manyfire conditions it hasdetected.
S P E C I A L F E AT U R E
7/30/2019 System 8000
7/10
P A N E L O R D E R C O D E S
ORDER CODE
Standard Panel. 786050
Standard Panel complete 786150with 64 Zone Indication.
Standard Panel complete 786450with extended LCDdisplay.
Standard Panel complete 786550with 64 Zone indication& extended LCD display.
Neutral front 742838
192 Zone indication 786000
Neutral Front 742838
Upper Housing Options
Lower Housing Options
1. SELECT DOUBLE FIRST FIXHOUSING.
2. SELECT 1 OPERATING MODULEFOR EACH HOUSING FROM THEOPTIONS LIST ON THIS PAGE.
3. 1 LOOP CARD SUPPLIED ASSTANDARD PLEASE ORDERADDITIONAL CARDS AS REQUIRED.
4. FOR SURFACE CABLING IT ISNECESSARY TO ORDER 2 x 789310EXTENSION BOXES.
Code 788299First Fix comprising
double housing,2 neutral fronts and
1 loop card
7/30/2019 System 8000
8/10
P R I N T E R O P T I O N S
ORDER CODE
Standard Panel with 789398printer c/w housing.
Standard Panel with 789399printer and take upspool c/w housing.
Neutral front 742838
192 Zone indication 786000
LOOP CARDS
Single loop card 784382
Network card 784840
Note: First Fix items include one
loop card and capacity for 4 loops +
1 network or 5 loops.
For 6 or 7 loops it is necessary to
order the extension module 772421.
The printer options must bemounted in the upper housing.
1. SELECT DOUBLE FIRST FIXHOUSING.
2. SELECT 1 OPERATING MODULEFOR EACH HOUSING FROM THEOPTIONS LIST ON THIS PAGE.
3. 1 LOOP CARD SUPPLIED ASSTANDARD PLEASE ORDERADDITIONAL CARDS AS REQUIRED.
4. FOR SURFACE CABLING IT ISNECESSARY TO ORDER 3 x 789310EXTENSION BOXES.
Code 788299First Fix comprising
double housing,2 neutral fronts and
1 loop card
Printer option(supplied complete with
housing).
7/30/2019 System 8000
9/10
8 0 0 0 O U T S T A T I O N S
Sensor Bases and Ancillaries Order Codes
Sensor base 781415
Sensor base with relay output 781417
Sensor base with isolator 781416
Sensor base with surface mount adaptor 781495
Sensor lock 781496
Sensor protective cage 781550
Sensor base adaptor for flush mounting 781497
Sensor base adaptor for conduits 781498
Sensor removal tool 769804
Sensor dust cover 789855
Manual Call Points Note - Standard & Key operated MCPs require a surface (706080) or flush (706081) box.
Standard IP65 Key Operated Hinged Cover
Approximate Weight 0.17kg 470g 0.17kg
IP Rating IP54 IP65 IP54
Dimensions (mm) 88 square x 55 deep 123W x 120H x 80D 88 square x 55 deep
Order Codes 706120 with isolator 706022 706021 706901
706220 without isolator
Sounders Note - Sounder outputs are variable dependent upon tone choice.
Shallow Base Deep Base (IP65) Bedhead Sounder Sounder Base
Operation Continuous Continuous Continuous Continuous
Operating Voltage Range 9 - 28V DC 9 - 28V DC 9 - 28V DC 10 - 28V DC
Typical Sound Output @ 1m, 12V DC 93dBA 93dBA 94dBA 87dBA
Typical Sound Output @ 1m, 24V DC 100dBA 100dBA 97dBA 93dBA
Current Consumption 8mA @ 12V, 8mA @ 12V, 8mA @ 12V, 8mA @ 12V,
18mA @ 24V 18mA @ 24V 18mA @ 24V 18mA @ 24V
IP Rating IP54 IP65 IP54 IP54
Approximate Weight 0.29kg 0.31kg 0.11kg 0.15kg
Dimensions (mm) 93 dia x 75 deep 93 dia x 105 deep 86 square x 42 deep 112 dia x 30 deep
Order Code 74451-24NM 74452-24NM 74455-24NM 74456-24NM
Transponder Interfaces
Sounder Controller 12 Relay 32 LED 4/2 1 Zone
Description 2 Sounder circuits 12 relay 32 outputs to drive 4 detector Single(0.5A), individually outputs LEDs zones/ 2 detector zonecontrolled sectors relay outputsAux 24V @0.5A
Max No. per loop Up to 100 interfaces per control panel. Max 32 per zone on an analogue loop
Approximate Weight 3.3Kg 95g 95g 380g 380g
Ingress Protection IP31 IP50 IP50 IP50 IP50
Battery Supply 2 x 12V 2.1 Ah
Operating Temperature -20C to +50C -20C to +70C -20C to +70C -20C to +50C -20C to +50C
Dimensions (mm) 317Wx248Hx83D 189Wx131Hx47D 189Wx131Hx47D 189Wx131Hx47D 189Wx131Hx47D
Order Code 788618 788610 788611 788616 788617
Suitable for standardand key operated
versions
7/30/2019 System 8000
10/10
A Caradon Company 8000/4M/6/00
GENT 24 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN.Tel: 0800 013 8824 Fax: 0800 013 8825
Because of the continuous development of Gent 24 equipment, details of the products described in this publication are subject to change without notice.
Gent 24 products are available through a network of approved system integrators.