Page 1: Universal Heat Pump Defrost Control ... - copeland-scroll.comcopeland-scroll.com/.../Documents/cross-reference.pdf · Fast 1093410 Goettl 305007 Goodman 1084-03-2022 ... Compressor

R-4430

Saint Louis, Missouri Markham, Ontario314-553-3600 905-948-3411

white-rodgers.comemersonclimate.com

The Emerson logo is a trademark anda service mark of Emerson Electric Co.

Specifications

Replaces:

AmanaC64301-1C6431001Arcoaire32312-003232140Armstrong39840B00144614-00144614-00246257-00147181-001R46257-001R46614-002R47181-001Carrier150-83-6A621-xxxCES0110063-00CES0110063-01CES0110063-02ACES0130024-00CES0130024-01CES0130076HK25SZ359AHK32EA001HK32EA003HK32EA007HK32EA008HK32FA003HK32FA006Coleman3030A374

Comfortmaker1029-23433210034332101Evcon9218-374Fast1093410Goettl305007Goodman1084-03-20221084-200D20293901B1226006B1226008LR40061PCBDM101PCBDM130PCBDM133PCBDM160Heil QuakerHQ1052757Heil/Tempstar108795210879531173636CEPL130524-01HoneywellST74A1004ST74A1020ST74A1038

ST74A1053ST74C1002ICMDFORB24A2I300DFORB-AB1004DFORFDFOSP24A2ICM300CICM301CICM302CICM303CICM304ICM307ICM316ICM317ICM318ICM319ICM320ICM321ICM322ICM323W1001-4ICP10527571069364Intertherm6208800Lennox100269-01100269-02100269-04100269-0511K7101

1507N17002729M010129M020130W8733G950134M630146K6756M370168J290168J840178H680184W880186G160197M81LB-101263ALB-101263BNordyne620880621301A621579B621579C624519A624608624626624633624644624656624700917012917178917178A920338RancoDT2

Rheem47-102684-0147-102684-02 47-102684-03 47-102684-04 47-102684-07 47-102684-08 47-102684-83 47-102685-01 47-102685-02 47-102685-03 47-102685-04 47-102685-05 47-102685-06 47-102685-84 47-21517-11 47-21517-13 47-21517-14 47-21517-16 47-21517-1747-21517-1847-21517-2247-21517-2347-21517-2447-21517-8247-21517-8847-21517-9247-21776-0147-21776-0647-21776-86DDL-013002-0RHDDL-013002-1RHDDL-013102-1RHDDL-017002-2RH

DDL-017102-1RHDDL-017702-1RHDDL-117702-3RHDDL-122131-2RHRobertshawDT2-1000TD-10SnyderGeneral1395-329CEBD430524-04BTempstar/ICP1084-1001084-83-10081087562Trane21C140501G1821C140501G2721C140501G3621C140501G3721C140501G3821C140501G4221C140501G4421C140501G4521C140501G5321C140501G5421C140501G5521C140501G6021C142827G01CNT01106CNT01108CNT01129CNT01152CNT01431

CNT01510CNT01642CNT01923CNT01924CNT01926CNT02514CNT02515CNT02516CNT02920CNT02935CNT03715CNT03716CNT04362CNT04363CNT04364CNT04366CNT04368CNT04695CNT05001CNT05008CNT05009CNT05010CNT05482CNT05875Weatherking840-4-5548White-Rodgers47D40-80147D43-10147D43-11147D43-111 0247D43-81190-621

York031-00872-001031-00872-002031-00872-003031-00872-701031-00872-702031-00872-703031-01222-000031-01251-000031-01268-000031-01954-000031-01975-000031-09104-000031-09170-000331-01975-001331-01975-102331-09139-0009218-3741S1-03100872701S1-03109170000S1-33101954000S1-33101975102

Cross Reference: Replaces virtually all single stage defrost controls, including:

Universal Heat Pump Defrost ControlFor Single Stage Applications

47D01U-843

Electrical RatingControl Voltage: 24 VAC 50/60 HzLine Voltage: 208/240 VAC 50/60 HzInput Ratings: Outdoor PSC Fan: 0.5 HP @ 240 VAC, 0.125 HP @ 120 VAC Contactor Coil: 24 VAC Aux Heat (D/W/X2): 24 VAC Reversing Valve: 24 VAC

Operating Temperature Range -40° to 150°F (-40° to -65°C)

Humidity Range 0 - 95% relative humidity, non condensing

Dimensions / Mounting 5.75”W x 4.72”L x 1.75”H

Replacement Kit ContentsDefrost control board, wiring harnesses, coil and ambient temp sensors, mounting accessories and labels.

Auxiliary Heat LockoutAbove the selected temperature, auxiliary heat will only run during defrost operation. Selectable from 0° to 40°F or off*.

Compressor LockoutBelow the selected temperature the compressor does not operate, except in defrost cycle. Selectable from -10° to 45°F or off*.

Reversing Valve Shift Delay Limit excessive noise in and out of a defrost cycle. Selectable 0, 12 or 30* second delay.

Short-Cycle Protection0, 3 or 5* minute selectable delay between cycles.

Brownout Protection Auto shut off when control voltage drops below 16 VAC for more than 4 seconds . Selectable On* or Off.

Random Start DelayDelays operation for a random delay after power outage to protect the compressor and avoid brownouts. Selectable On* or Off.

Timing SpecificationsAll timing is accurate to +/- 5% of nominal over the full temperature and voltage range at 60 Hz. All timings are 20% longer when operated with 50 Hz power supply.

*=Default Setting

For complete, up to date cross reference information, install WRMobile on your iOS or Android smartphone today.