SentrySuite™ Software Platformintel l igent respiratory diagnost ics
3
Complete PFT and CPET measurement in one user-friendly interface.Every stage, from calibration to reporting, is navigated without moving to another program.
ONE screen allows clinicians and physicians a completely inclusive view.
Measurement capabilities:
Complete Spirometry (FVC, SVC, MVV) pre/post dilator
Bronchial Challenge Testing
Lung Volumes, FRC by N2 Washout
Body Plethysmography (FRC pleth, Raw)
SB Diffusing Capacity
SB Diffusing Capacity, Intrabreath
MIP/MEP
IOS
CPET, breath-by-breath
REE, mask
ECG, Rest & Stress
Our SentrySuite software powers all of your Vyntus™ Systems, making them incredibly easy to operate from system-to-system and test-to-test. The simple user interface with guidance cues and QC feedback, ensures that patient test performance is acceptable and repeatable. And, SentrySuite provides automated workflow processes that let you keep tabs on the status of every test, simplifying operations in even the busiest labs.
SentrySuite seamlessly connects with your existing network and clinical infrastructures, making collaboration easy from everywhere. And, all of this happens under an advanced umbrella of cybersecurity, with stringent access controls to keep sensitive patient information safe and protected.
THE POWER OF SENTRYSUITE. SIMPLE TO OPERATE, YET SOPHISTICATED FOR YOUR TEAM’S WIDE-RANGING CLINICAL NEEDS.
2
SEC
UR
E
CO
NN
ECTI
VIT
YN
ORM
ATIV
E RE
FERE
NC
E
VALU
ES &
RES
EARC
HQ
UES
TIO
NN
AIR
ES &
O
FFLI
NE
CA
PAB
ILIT
IES
INTE
RPR
ETAT
ION
&
TREN
DIN
GW
OR
KFLO
W &
R
EVIE
WG
UID
AN
CE
&
QU
ALI
TYM
EASU
REM
ENT
4 5
SentrySuite software guides both technicians and patients through a quality testing experience.
Animation incentives
Choose from 10 different patient animations
for forced spirometry. And, easily set target
ranges for different patient needs.
CO Diffusion SB Realtime
Body Plethysmography
Forced Spirometry
Biological Control
SentrySuite supports biologic control
testing with a separate BIO QC database.
The BIO QC data is easily identified and
isolated for trending and further analysis.
Mechanical Quality Control
With SentrySuite Quality Management you
can validate your measurement device
using calibrated syringes, FRCpleth or DLCO
simulators. Predefined special SeS QM patients
automatically switch-off BTPS compensation
and correct appropriately for mechanical
dead space.
And provides Quality Control tools to help technicians assess both patient and device performance.
After each trial, SentrySuite provides feedback on the acceptability and repeatability of the measurement,
checking the results against the ATS/ERS guidelines or other defined standards.
Colored guidance bar for in-test exhalation time and plateau recognition
Check marks for spirometry end-of-test criteria
Online breathing curves
Online content guidance ideal for new personnel
FRCpleth notification for conformity
Colored stability bar for VT, BF, sRaw and FRCpleth during body plethysmography
Breath-hold timer and mouth pressure control
SEC
UR
E
CO
NN
ECTI
VIT
YN
ORM
ATIV
E RE
FERE
NC
E
VALU
ES &
RES
EARC
HQ
UES
TIO
NN
AIR
ES &
O
FFLI
NE
CA
PAB
ILIT
IES
INTE
RPR
ETAT
ION
&
TREN
DIN
GW
OR
KFLO
W &
R
EVIE
WG
UID
AN
CE
&
QU
ALI
TYM
EASU
REM
ENT
7
• Ultra fast report view with results
on the left and interpretation on the right
• Customized interpretation templates
and macros
• Electronic signature
• Automated ‘Send-To-HIS’ functionality
• Status management
• SentrySuite Mobile Review provides
a web-based solution
SentrySuite’s flexible workflow has extensive filtering capabilities and can be customized to add additional steps, such as reviews by multiple
clinicians. And, it supports PDF uploads from other programs with the ability to add comments. It’s highly adaptable for any laboratory’s needs.
The power of SentrySuite makes it easy to visually track each patient through their laboratory visit.
TemplatesCustomize templates with macros
Automatic InterpretationSeveral authors come standard: Ellis, Jaeger (1994), ATS/ERS 2005, Intermountain Thoracic Society (1984), Methodist Hospital (1994), IOS, CPET Eschenbacher/Mannina (1990)
6
SEC
UR
E
CO
NN
ECTI
VIT
YN
ORM
ATIV
E RE
FERE
NC
E
VALU
ES &
RES
EARC
HQ
UES
TIO
NN
AIR
ES &
O
FFLI
NE
CA
PAB
ILIT
IES
INTE
RPR
ETAT
ION
&
TREN
DIN
GW
OR
KFLO
W &
R
EVIE
WG
UID
AN
CE
&
QU
ALI
TYM
EASU
REM
ENT
8 9
Comprehensive reporting that’s simple to customize.
SentrySuite provides recommended reporting capabilities with highly adaptable customization to suit your team’s specific needs.
• Compare previous PFT results in one view
• Combine gas exchange data and ECG data in a single report
• 2017 DLCO grading
• Numerical and graphical Z-score capability including colorized Quanjier bars for severity
Graphic display offers easy review of patient trends.
With the power of SentrySuite, trending reports are standard; one click shows long term data for any parameter.
US_CPET_VMAX_23 1 / 6
Your HospitalYour City, Your StatePulmonary Function Lab
Peak Cardiovascular Responses
Summary Predicted8 Breaths
Measured8 Breaths
% Predicted8 Breaths
V'O2/kg [(mL/min)/kg] 34.9 37.3 107V'O2 [L/min] 3.2 3.5 107V'CO2 [L/min] 3.9Load [W] 248 312 126HR [BPM] 182 181 99O2pulse [mL] 17.8 19.1 107Psys [mmHg] 140Pdia [mmHg] 86
V'E [L/min] 129 126 97VTex [L] 3.719RR [1/min] 33.8BR FEV% [%] 28 15 53VTe%IC [%]
Peak Ventilatory Responses
Spirometry
Last Name: OD First Name: B Identification: TEST 2Age: 38 Years Height: 74.0 Inch Weight: 205.0 lbsGender: male BMI: 26
_____________________________________Resting Data
Summary Rest (R)8 Breaths
HR [BPM] 84SpO2 [%] 100Psys [mmHg]Pdia [mmHg]
0 5 10 15 20Time min
0.0
1.0
2.0
3.0
4.0
L/minV'O2
0
50
100
150
200BPMHR
1.0
2.0
3.0
4.0
L/minV'CO2
W T R
2 4 6 8
Vol [L]
10
5
0
5
10 F/V ex
____________________________________
Heart rate reserve (B/min) [BPM] Peak values (R)-20
Normal
15
High
30
1
Breathing reserve (FEV1) % [%] Peak values (R)0
Low
20
Normal
40
High
60
15
Peak Phase Bar Data
0
1
2
3
4
5
6
7
0 30 77 167 260
RV
EELV
EILV
TLC
Load
SEC
UR
E
CO
NN
ECTI
VIT
YN
ORM
ATIV
E RE
FERE
NC
E
VALU
ES &
RES
EARC
HQ
UES
TIO
NN
AIR
ES &
O
FFLI
NE
CA
PAB
ILIT
IES
INTE
RPR
ETAT
ION
&
TREN
DIN
GW
OR
KFLO
W &
R
EVIE
WG
UID
AN
CE
&
QU
ALI
TYM
EASU
REM
ENT
10 11
Vyntus Questionnaire. One more way to make your work processes more efficient. Vyntus Questionnaire allows efficient collection of pre-test information. It can be
collected on the SentrySuite workstation or via mobile devices. Once completed,
answers are automatically scored if needed, and seamlessly integrated into
the patient record. SentrySuite offers standard questionnaires, or create your
own using the optional Questionnaire Designer, with a variety of question types.
Everything is right where you need it, when you need it most.
The power of SentrySuite brings scoring functionality to your questionnaires.
QUESTIONNAIRE
WorkstationSentrySuiteSoftware
WiFi
Questionnaire
Questionnaire
Vyntus Questionnaire App
Save time and use a tablet or phone to collect
your patient’s data while they’re waiting for
their appointment.
• Mobile multi-platform—IOS or Android
• Multilingual and intuitive menu navigation
• Secure communication
• Integration of patient image
Example of an offline Nitric Oxide measurement entry.
Fundamental offline capabilities.
Extend and populate your SentrySuite database with additional external
measurements, like exhaled NO, lactate values and blood gases.
1. Create a new parameter set or use implemented parameter sets
2. Type in and save your measurement results to the SentrySuite database
3. Interpret, view and print together with your PFT/CPET data on one common report
SEC
UR
E
CO
NN
ECTI
VIT
YN
ORM
ATIV
E RE
FERE
NC
E
VALU
ES &
RES
EARC
HQ
UES
TIO
NN
AIR
ES &
O
FFLI
NE
CA
PAB
ILIT
IES
INTE
RPR
ETAT
ION
&
TREN
DIN
GW
OR
KFLO
W &
R
EVIE
WG
UID
AN
CE
&
QU
ALI
TYM
EASU
REM
ENT
12 13
SentrySuite provides access to patient data for clinical research.
Access lung function data for clinical research and
statistics using the Sentry Data Cube. This query tool
provides easy access to your patient database.
• Direct output into spreadsheet software
such as Microsoft Excel®
• Benefit from various table configurations
• Customize query and output tables
SentrySuite includes a comprehensive Normative Reference Library
SentrySuite comes ready-equipped with normative reference modules
that include the most up-to-date recommendations, including NHANES
III, GLI 2012, and 2017 DLCO GLI. As well as historic sets like Morris & Polgar,
plus many more. This extensive library is easily searchable by Module
Name or Author.
Reference modules are completely customizable
Clinicians know that not all reference sets represent all patients.
And, ATS/ERS guidelines state that the ideal reference set comes from
a normal population, most closely matching the population being tested.
So, the SentrySuite Predicted Value Generator offers a completely
customizable way to create your own unique reference modules and
equations for any parameter and reference modules, using standard,
dynamic, or natural logarithmic distribution.
All parameters are included in a single module, ensuring no extra
steps when patients arrive for testing.
Pre-test your reference equations to determine if your customized
ranges meet your lab and patient needs.
SEC
UR
E
CO
NN
ECTI
VIT
YN
ORM
ATIV
E RE
FERE
NC
E
VALU
ES &
RES
EARC
HQ
UES
TIO
NN
AIR
ES &
O
FFLI
NE
CA
PAB
ILIT
IES
INTE
RPR
ETAT
ION
&
TREN
DIN
GW
OR
KFLO
W &
R
EVIE
WG
UID
AN
CE
&
QU
ALI
TYM
EASU
REM
ENT
14 15
Secure connectivity. The power of SentrySuite changes everything, by changing nothing on your end.
The SentrySuite software platform seamlessly connects with your existing network and clinical infrastructures, making data transfer to and from the
EMR that much easier. Plus, our security features help ensure that your patient data remains protected. Our experienced IT project management
team will perform an assessment to ensure that your existing systems coalesce with ours. And, they’ll be there for you every step of the way.
Patient and measuring data
CITRIXPatient data
Non-Vyaire data import SentrySuite SQL Server
Hospital Information System
WorkstationSentrySuite Software, web-based
and Citrix based network environments
Vmax™ Encore MasterScreen
Connectivity
• SQL database
• Easier Installation and Network Maintenance via
centralized tools that apply changes across the system
• HL7 Messaging with discrete data and PDF graphics
provides full visual clinical reporting
Role-based System Security
• Authentication Authorization, and Audit protects key
patient health information and provides an audit trail
of important data access.
• Active directory interface provides facility-level
password management so users don’t have to
remember multiple passwords.
• User Administration and Group Rights can restrict
rights so not everyone has access to everything;
a role-based NIST cybersecurity standard.
Vyntus PFT Systems Vyntus CPX Vyntus SPIRO Vyntus WALK
SEC
UR
E
CO
NN
ECTI
VIT
YN
ORM
ATIV
E RE
FERE
NC
E
VALU
ES &
RES
EARC
HQ
UES
TIO
NN
AIR
ES &
O
FFLI
NE
CA
PAB
ILIT
IES
INTE
RPR
ETAT
ION
&
TREN
DIN
GW
OR
KFLO
W &
R
EVIE
WG
UID
AN
CE
&
QU
ALI
TYM
EASU
REM
ENT
vyaire.com
U.S. distribution onlyTrademarks are the property of their respective owners. © 2019 Vyaire. Vyaire, the Vyaire logo and all other trademarks or registered trademarks are property of Vyaire Medical, Inc., or one of its affiliates. VYR-US-1800019 (1118)
G L O B A L H E A D Q U A R T E R S
Vyai re Medica l , Inc.26125 Nor th R iverwoods B lvdMettawa, I L 60045, USA