In general all ISO9000 certified companies has to recalibrate traceableall flowmeters which are relevant for quality control.
Different methods are available:
• Flowmeter is sent back for recalibration
Long shut down time
• Flowmeter will be compared with a scale
Sample has to be taken and a traceable scale must be available
• Flowmeter will be compared with a volume
Sample has to be taken and an approved tank must be available
• Flowmeter will be compared with a reference
„mobile calibration rig“
Requirement from the industry
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 4/15
04/01/2004
mobile calibration rig
Losert
Slide 4
Inline calibration in field
SCS-calibration in
Reinach / Cernay
Calibration rig
accredited according to
ISO/IEC17025
Mobile calibration rig
By the customer
Traceable recalibration
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 5/15
04/01/2004
mobile calibration rig
Losert
Slide 5
Accredited and traceable calibration
Diameter 1 mm up to 2000mm
Total Accuracy 0f 0.05%
Economical for single devices
Requirements
Delivery to the factory
Flowmeter must be cleaned
Recalibration in the factory
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 6/15
04/01/2004
mobile calibration rig
Losert
Slide 6
Specification of the mobile rig
We will design the mobile rig according to your application:
• Construction such as piping, material, process connection, devices
•Task i.e. registration, visualisation of the measureing values, pump
control, batching etc.
• Different kind of power supply, compressed air, for hazardous areas
• All devices can be calibrated traceable
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 7/15
04/01/2004
mobile calibration rig
Losert
Slide 7
Project handling
• After the first customer contact, the customer should decide either one
of the two standards are suitable or he needs a different rig.
• A specification sheet supports to specify the rig.
• The offer will be prepared according to the specification sheet.
• E+H will manage all the sub-suppliers, set up and test the rig.
• Afterwards, the rig will be calibrated in PC Flowtec.
• A witness test can be ordered optionally
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 8/15
04/01/2004
mobile calibration rig
Losert
Slide 8
Standard EEx
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 9/15
04/01/2004
mobile calibration rig
Losert
Slide 9
Standard EEx
Prepared for master meter DN08 and DN25
Batch controler for dosing, for totalizing, etc.
Piping made in 1.4404
Pneumatic ball valve
SCS calibration
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 10/15
04/01/2004
mobile calibration rig
Losert
Slide 10
Standard non-hazardous
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 11/15
04/01/2004
mobile calibration rig
Losert
Slide 11
Standard non-hazardous
Prepared for master meter DN08 and DN25
2 external totalizer
2 external displays for actual flow rates of the masters
Piping made in 1.4404
Manual ball valve
SCS calibration
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 12/15
04/01/2004
mobile calibration rig
Losert
Slide 12
Baxter Hemoglobine Therapeutics
• 3 Promass (DN1, 4, 8)
• Non Ex
• Hygienic Design
• Frequency controlled pumps
• Totalizer
• In-line calibration
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 13/15
04/01/2004
mobile calibration rig
Losert
Slide 13
• 2 Promass (DN25 + 50)
• Non Ex
• PLC controled batching
• Pneumatic valves
• Megalog T recorder
• Temperatur sensor
Baxter Hemoglobine Therapeutics
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 14/15
04/01/2004
mobile calibration rig
Losert
Slide 14
Algroup Lonza
• 2 Promass (DN8 + 50))
•
Ex Zone 1• Memograph Logger
• In-line calibration
8/19/2019 Mobile Rig
http://slidepdf.com/reader/full/mobile-rig 15/15
04/01/2004
mobile calibration rig
Losert
Slide 15
Short shut down time only during the calibration
No mounting or demounting of the sensor
Recalibration on traceable international standards
Advantage for a recalibration in field