Top Banner
8/19/2019 Mobile Rig http://slidepdf.com/reader/full/mobile-rig 1/15 04/01/2004 Losert Slide 1 mobile calibration rig 
15

Mobile Rig

Jul 07, 2018

Download

Documents

aku_kerenbgt
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 1/15

04/01/2004

Losert 

Slide 1

mobile calibration rig 

Page 2: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 2/15

04/01/2004

mobile calibration rig 

Losert 

Slide 2

Mobile calibration rig 

Page 3: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 3/15

04/01/2004

mobile calibration rig 

Losert 

Slide 3

In general all ISO9000 certified companies has to recalibrate traceableall flowmeters which are relevant for quality control.

Different methods are available:

• Flowmeter is sent back for recalibration

Long shut down time

• Flowmeter will be compared with a scale

Sample has to be taken and a traceable scale must be available

• Flowmeter will be compared with a volume

Sample has to be taken and an approved tank must be available

• Flowmeter will be compared with a reference

„mobile calibration rig“

Requirement from the industry 

Page 4: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 4/15

04/01/2004

mobile calibration rig 

Losert 

Slide 4

Inline calibration in field 

SCS-calibration in

Reinach / Cernay 

Calibration rig

accredited according to

ISO/IEC17025

Mobile calibration rig 

By the customer 

Traceable recalibration

Page 5: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 5/15

04/01/2004

mobile calibration rig 

Losert 

Slide 5

 Accredited and traceable calibration

Diameter 1 mm up to 2000mm

Total Accuracy 0f 0.05%

Economical for single devices

Requirements

Delivery to the factory 

Flowmeter must be cleaned

Recalibration in the factory 

Page 6: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 6/15

04/01/2004

mobile calibration rig 

Losert 

Slide 6

Specification of the mobile rig 

 We will design the mobile rig according to your application:

• Construction such as piping, material, process connection, devices

•Task i.e. registration, visualisation of the measureing values, pump

control, batching etc.

• Different kind of power supply, compressed air, for hazardous areas

• All devices can be calibrated traceable

Page 7: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 7/15

04/01/2004

mobile calibration rig 

Losert 

Slide 7

Project handling 

• After the first customer contact, the customer should decide either one

of the two standards are suitable or he needs a different rig.

• A specification sheet supports to specify the rig.

• The offer will be prepared according to the specification sheet.

• E+H will manage all the sub-suppliers, set up and test the rig.

• Afterwards, the rig will be calibrated in PC Flowtec.

• A witness test can be ordered optionally 

Page 8: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 8/15

04/01/2004

mobile calibration rig 

Losert 

Slide 8

Standard EEx

Page 9: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 9/15

04/01/2004

mobile calibration rig 

Losert 

Slide 9

Standard EEx

Prepared for master meter DN08 and DN25

Batch controler for dosing, for totalizing, etc.

Piping made in 1.4404

Pneumatic ball valve

SCS calibration

Page 10: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 10/15

04/01/2004

mobile calibration rig 

Losert 

Slide 10

Standard non-hazardous

Page 11: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 11/15

04/01/2004

mobile calibration rig 

Losert 

Slide 11

Standard non-hazardous

Prepared for master meter DN08 and DN25

2 external totalizer

2 external displays for actual flow rates of the masters

Piping made in 1.4404

Manual ball valve

SCS calibration

Page 12: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 12/15

04/01/2004

mobile calibration rig 

Losert 

Slide 12

Baxter Hemoglobine Therapeutics

• 3 Promass (DN1, 4, 8)

• Non Ex

• Hygienic Design

• Frequency controlled pumps

• Totalizer

• In-line calibration

Page 13: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 13/15

04/01/2004

mobile calibration rig 

Losert 

Slide 13

• 2 Promass (DN25 + 50)

• Non Ex

• PLC controled batching 

• Pneumatic valves

• Megalog T recorder

• Temperatur sensor

Baxter Hemoglobine Therapeutics

Page 14: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 14/15

04/01/2004

mobile calibration rig 

Losert 

Slide 14

 Algroup Lonza 

• 2 Promass (DN8 + 50))

Ex Zone 1• Memograph Logger

• In-line calibration

Page 15: Mobile Rig

8/19/2019 Mobile Rig

http://slidepdf.com/reader/full/mobile-rig 15/15

04/01/2004

mobile calibration rig 

Losert 

Slide 15

Short shut down time only during the calibration

No mounting or demounting of the sensor

Recalibration on traceable international standards

 Advantage for a recalibration in field