Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: ACID PHOS Catalog # : HA703 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW---------------------------------------------------------------- SELECT TEST: ACP ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: ACP ASSAY/TIME/POINT: APP CODE: # User defined WAVE (2 ND /PRIMARY): ---/415 SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 20 20 R1: 350 DECREASE: # # R2: 0 INCREASE: # # R3: 0 R4: 0 CLASS 1 CLASS 2 DEC/INC ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER ---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW--------------------------------------------------------- SELECT TEST: ACP CALIBRATION TYPE: LINEAR POINT: SPAN POINT: WEIGHT: 0 AUTO CALIBRATION TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 10000 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: ----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW------------------------------------------------------------------- SELECT TEST: AC{ REPORT NAME: ACP DATA MODE: ON BOARD TEST NAME: ACP CTRL INTERVAL: 1000 UNIT: U/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0.0-9.0 - (2) 0.0 100 YEARS - - (3) 0.0 - - (4) 0.0 (5) 0.0 DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.0-35.0 CLASS 2 TECHNICAL RANGE: -99999 -99999 ----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW----------------------------------------------------------------- <STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 POSITION: # SAMPLE VOLUME: 20 20 20 20 20 20 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0 # DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03
35

Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # :...

Mar 16, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: ACID PHOS

Catalog # : HA703 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: ACP ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: ACP ASSAY/TIME/POINT: APP CODE: # User defined WAVE (2ND

/PRIMARY): ---/415

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 20 20 R1: 350 DECREASE: # # R2: 0 INCREASE: # # R3: 0

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: ACP CALIBRATION TYPE: LINEAR POINT: SPAN POINT: WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 10000 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE:

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: AC{ REPORT NAME: ACP DATA MODE: ON BOARD TEST NAME: ACP CTRL INTERVAL: 1000 UNIT: U/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0.0-9.0 - (2) 0.0 100 YEARS - - (3) 0.0

- - (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.0-35.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 POSITION: # SAMPLE VOLUME: 20 20 20 20 20 20 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 2: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: ALBUMIN

Catalog # : HA901-1400 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: ALB ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: ALB ASSAY/TIME/POINT: 1-POINT 10 5 0 0 0 APP CODE: # 702 WAVE (2ND

/PRIMARY): 700 600

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 350 DECREASE: # # R2: 0 INCREASE: # # R3: 0

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: ALB CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 75 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: -1000 6000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: ALB REPORT NAME: ALBUMIN DATA MODE: ON BOARD TEST NAME: ALB CTRL INTERVAL: 1000 UNIT: G/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 3.5-5.3 3.5-5.3 (2) 0.0 100 YEARS 3.5-5.3 3.5-5.3 (3) 0.0

3.5-5.3 3.5-5.3 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.5-6.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 3: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: ALP

Catalog # : HA916-492 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: ALP ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: ALP ASSAY/TIME/POINT: RATE-A 10 20 31 0 0 APP CODE: # 704 WAVE (2ND

/PRIMARY): 660 415

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 6 6 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 11000 11000 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: ALP CALIBRATION TYPE: LINEAR POINT: 1 SPAN POINT: 1 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 5800

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: ALP REPORT NAME: ALP DATA MODE: ON BOARD TEST NAME: ALP CTRL INTERVAL: 1000 UNIT: U/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 35-123 35-123 (2) 0.0 100 YEARS 35-123 35-123 (3) 0.0

35-123 35-123 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-1000 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 POSITION: # SAMPLE VOLUME: 6 6 6 6 6 6 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 4: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: ALT

Catalog # : HA926-610 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: ALT ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: ALT ASSAY/TIME/POINT: RATE-A 10 20 31 0 0 APP CODE: # 706 WAVE (2ND

/PRIMARY): 700 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 10 10 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 5500 5500 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: ALT CALIBRATION TYPE: LINEAR POINT: 1 SPAN POINT: 1 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 8300 20000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: ALT REPORT NAME: ALT DATA MODE: ON BOARD TEST NAME: ALT CTRL INTERVAL: 1000 UNIT: U/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 4-36 4-36 (2) 0.0 100 YEARS 4-36 4-36 (3) 0.0

4-36 4-36 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-700 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 POSITION: # SAMPLE VOLUME: 10 10 10 10 10 10 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 5: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: AMMONIA

Catalog # : A7553 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: AMMON ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: AMMON ASSAY/TIME/POINT: 2-POINT 10 16 31 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 376 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 40 40 R1: 230 DECREASE: # # R2: 0 INCREASE: # # R3: 10

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 5500 5500 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: AMMON CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: -1500 3000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: AMMON REPORT NAME: AMMONIA DATA MODE: ON BOARD TEST NAME: AMMON CTRL INTERVAL: 1000 UNIT: UMOL/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 11-35 11-35 (2) 0.0 100 YEARS 11-35 11-35 (3) 0.0

11-35 11-35 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-600 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 40 40 40 40 40 40 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Rev.8-03

Page 6: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: AMYLASE

Catalog # : HA965-324 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: AMY ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: AMY ASSAY/TIME/POINT: RATE-A 10 10 16 0 0 APP CODE: # 566 WAVE (2ND

/PRIMARY): 700 415

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 6 6 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 13000 13000 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: AMY CALIBRATION TYPE: LINEAR POINT: 1 SPAN POINT: 1 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 4900

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: AMY REPORT NAME: AMYLASE DATA MODE: ON BOARD TEST NAME: AMY CTRL INTERVAL: 1000 UNIT: U/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 25-125 25-125 (2) 0.0 100 YEARS 25-125 25-125 (3) 0.0

25-125 25-125 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-2000 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 POSITION: # SAMPLE VOLUME: 6 6 6 6 6 6 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 7: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: ASO

Catalog # : A7566 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: ASO ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: ASO ASSAY/TIME/POINT: APP CODE: # User defined WAVE (2ND

/PRIMARY): 700 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 15 15 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: INCREASE PROZONE LIMIT: LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: ASO CALIBRATION TYPE: LINEAR POINT: SPAN POINT: WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 1000 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: ASO REPORT NAME: ASO DATA MODE: ON BOARD TEST NAME: ASO CTRL INTERVAL: 1000 UNIT: U/ML INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0-156 0-156 (2) 0.0 100 YEARS 0-156 0-156 (3) 0.0

0-156 0-156 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 50-1000 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 15 15 15 15 15 15 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 8: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: AST

Catalog # : HA961-610 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: AST ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: AST ASSAY/TIME/POINT: RATE-A 10 20 31 0 0 APP CODE: # 715 WAVE (2ND

/PRIMARY): 700 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 10 10 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 5500 5500 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: AST CALIBRATION TYPE: LINEAR POINT: 1 SPAN POINT: 1 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 8300 20000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: AST REPORT NAME: AST DATA MODE: ON BOARD TEST NAME: AST CTRL INTERVAL: 1000 UNIT: U/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 5-34 5-34 (2) 0.0 100 YEARS 5-34 5-34 (3) 0.0

5-34 5-34 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-700 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 POSITION: # SAMPLE VOLUME: 10 10 10 10 10 10 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev. 8-03

Page 9: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: DIRECT BILIRUBIN

Catalog # : HB936-294 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: DBIL ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: DBIL ASSAY/TIME/POINT: 2-POINT 10 16 31 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 660 570

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 20 20 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 65

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 20000 20000 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: DBIL CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 200 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: -100 1500

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: DBIL REPORT NAME: DIRECT BILIRUBIN DATA MODE: ON BOARD TEST NAME: DBIL CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0.0-0.5 0.0-0.5 (2) 0.0 100 YEARS 0.0-0.5 0.0-0.5 (3) 0.0

0.0-0.5 0.0-0.5 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.0-20.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 20 20 20 20 20 20 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 10: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: UREA NITROGEN

Catalog # : HB952-1020 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: UN ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: UN ASSAY/TIME/POINT: 2-POINT 10 19 24 0 0 APP CODE: # WAVE (2ND

/PRIMARY): 376 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 150

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 7000 7000 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: UN CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 20000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: UN REPORT NAME: UREA NITROGEN DATA MODE: ON BOARD TEST NAME: UN CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 7-18 7-18 (2) 0.0 100 YEARS 7-18 7-18 (3) 0.0

7-18 7-18 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.0-150.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 11: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: TOTAL BILIRUBIN

Catalog # : HB979-693 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: TBIL ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: TBIL ASSAY/TIME/POINT: 2-POINT 10 15 0 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 660 570

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 10 10 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 65

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 20000 20000 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: TBIL CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 200 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: -100 1500

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: TBIL REPORT NAME: TOTAL BILIRUBIN DATA MODE: ON BOARD TEST NAME: TBIL CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0.2-1.2 0.2-1.2 (2) 0.0 100 YEARS 0.2-1.2 0.2-1.2 (3) 0.0

0.2-1.2 0.2-1.2 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.0-20.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 10 10 10 10 10 10 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 12: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: CALCIUM

Catalog # : HC902-1000 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: CA ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: CA ASSAY/TIME/POINT: 2-POINT 10 31 0 0 0 APP CODE: # 180 WAVE (2ND

/PRIMARY): 700 600

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 100

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: CA CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 7000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: CA REPORT NAME: CALCIUM DATA MODE: ON BOARD TEST NAME: CA CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 8.5-10.4 8.5-10.4 (2) 0.0 100 YEARS 8.5-10.4 8.5-10.4 (3) 0.0

8.5-10.4 8.5-10.4 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.0-15.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 13: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: CHOLESTEROL

Catalog # : HC910-1000 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: CHOL ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: CHOL ASSAY/TIME/POINT: 1-POINT 10 31 0 0 0 APP CODE: # 722 WAVE (2ND

/PRIMARY): 700 505

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 0

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: CHOL CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 200 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 4000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: CHOL REPORT NAME: CHOLESTEROL DATA MODE: ON BOARD TEST NAME: CHOL CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0-200 0-200 (2) 0.0 100 YEARS 0-200 0-200 (3) 0.0

0-200 0-200 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-700 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 14: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: CO2

Catalog # : HC704 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: CO2 ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: CO2 ASSAY/TIME/POINT: APP CODE: # User defined WAVE (2ND

/PRIMARY): 376 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 300 DECREASE: # # R2: 0 INCREASE: # # R3: 0

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: CO2 CALIBRATION TYPE: LINEAR POINT: SPAN POINT: WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 200 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE:

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: CO2 REPORT NAME: CO2 DATA MODE: ON BOARD TEST NAME: CO2 CTRL INTERVAL: 1000 UNIT: MEQ/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 23-34 23-34 (2) 0.0 100 YEARS 23-34 23-34 (3) 0.0

23-34 23-34 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-40 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 15: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: CREATINE KINASE

Catalog # : HC922-250 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: CK ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: CK ASSAY/TIME/POINT: 2-POINT 10 9 15 0 0 APP CODE: # 726 WAVE (2ND

/PRIMARY): 376 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 6 6 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 20000 20000 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: CK CALIBRATION TYPE: LINEAR POINT: 1 SPAN POINT: 1 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 6500

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: CK REPORT NAME: CREATINE KINASE DATA MODE: ON BOARD TEST NAME: CK CTRL INTERVAL: 1000 UNIT: U/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0-160 0-130 (2) 0.0 100 YEARS 0-160 0-130 (3) 0.0

0-160 0-130 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-1500 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 POSITION: # SAMPLE VOLUME: 6 6 6 6 6 6 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 16: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: CREATININE

Catalog # : HC939-1340 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: CREA ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: CREA ASSAY/TIME/POINT: 2-POINT 10 20 23 0 0 APP CODE: # 727 WAVE (2ND

/PRIMARY): 570 505

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 10 10 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 4500 4500 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: CREA CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 10 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: -100 4000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: CREA REPORT NAME: CREATININE DATA MODE: ON BOARD TEST NAME: CREA CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0.4-1.4 0.4-1.4 (2) 0.0 100 YEARS 0.4-1.4 0.4-1.4 (3) 0.0

0.4-1.4 0.4-1.4 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.0-15.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 10 10 10 10 10 10 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 17: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: CRP

Catalog # : C7564 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: CRP ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: CRP ASSAY/TIME/POINT: 2-POINT 10 16 31 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 700 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 12 12 R1: 280 DECREASE: # # R2: 0 INCREASE: # # R3: 70

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 32000 32000 INCREASE PROZONE LIMIT: -32000 -32000 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: CRP CALIBRATION TYPE: LOGIT-LOG 4P POINT: 6 SPAN POINT: 6 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 999 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 10000 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: -32000 32000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: CRP REPORT NAME: CRP DATA MODE: ON BOARD TEST NAME: CRP CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0-0.6 0-0.6 (2) 0.0 100 YEARS 0-0.6 0-0.6 (3) 0.0

0-0.6 0-0.6 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.1-25 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 12 12 12 12 12 12 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Rev.8-03

Page 18: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: GGT

Catalog # : HG959-315 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: GGT ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: GGT ASSAY/TIME/POINT: RATE-A 10 20 31 0 0 APP CODE: # 731 WAVE (2ND

/PRIMARY): 700 415

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 7 7 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 5500 5500 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: GGT CALIBRATION TYPE: LINEAR POINT: 1 SPAN POINT: 1 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 6200

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: GGT REPORT NAME: GGT DATA MODE: ON BOARD TEST NAME: GGT CTRL INTERVAL: 1000 UNIT: U/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 9-54 8-35 (2) 0.0 100 YEARS 9-54 8-35 (3) 0.0

9-54 8-35 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-1000 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 POSITION: # SAMPLE VOLUME: 7 7 7 7 7 7 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 19: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: GLUCOSE

Catalog # : HG921-1000 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: GLU ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: GLU ASSAY/TIME/POINT: 2-POINT 10 31 0 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 700 505

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 300 DECREASE: # # R2: 0 INCREASE: # # R3: 0

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: GLU CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 250 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 4700

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: GLU REPORT NAME: GLUCOSE DATA MODE: ON BOARD TEST NAME: GLU CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 65-110 65-110 (2) 0.0 100 YEARS 65-110 65-110 (3) 0.0

65-110 65-110 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-500 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 20: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: GLUCOSE

Catalog # : HG920-1200 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: GLU ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: GLU ASSAY/TIME/POINT: 2-POINT 10 31 0 0 0 APP CODE: # 767 WAVE (2ND

/PRIMARY): 700 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 300 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: GLU CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 250 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 4700

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: GLU REPORT NAME: GLUCOSE DATA MODE: ON BOARD TEST NAME: GLU CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 65-110 65-110 (2) 0.0 100 YEARS 65-110 65-110 (3) 0.0

65-110 65-110 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-500 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 21: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: TOTAL IRON

Catalog # : HI904-600 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: IRON ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: IRON ASSAY/TIME/POINT: 2-POINT 10 16 31 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 700 570

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 20 20 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: IRON CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 200 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 2000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: IRON REPORT NAME: TOTAL IRON DATA MODE: ON BOARD TEST NAME: IRON CTRL INTERVAL: 1000 UNIT: UG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 60-150 60-150 (2) 0.0 100 YEARS 60-150 60-150 (3) 0.0

60-150 60-150 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-700 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 20 20 20 20 20 20 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 22: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: LACTATE

Catalog # : L7596-50 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: LAC ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: LAC ASSAY/TIME/POINT: 1-POINT 10 15 0 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 700 546

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 150 DECREASE: # # R2: 0 INCREASE: # # R3: 100

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: LAC CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 200 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 4000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: LAC REPORT NAME: LACTATE DATA MODE: ON BOARD TEST NAME: LAC CTRL INTERVAL: 1000 UNIT: MMOL/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0.5-2.2 0.5-2.2 (2) 0.0 100 YEARS 0.5-2.2 0.5-2.2 (3) 0.0

0.5-2.2 0.5-2.2 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-20 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 23: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: LDL CHOLESTEROL

Catalog # : L7574 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: LDL ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: LDL ASSAY/TIME/POINT: 2-POINT 10 16 31 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 660 546

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 300 DECREASE: # # R2: 0 INCREASE: # # R3: 100

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: LDL CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 1000 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: -3000 20000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: LDL REPORT NAME: LDL CHOLESTEROL DATA MODE: ON BOARD TEST NAME: LDL CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0-130 0-130 (2) 0.0 100 YEARS 0-130 0-130 (3) 0.0

0-130 0-130 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-700 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 24: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: LDH

Catalog # : HL956-568 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: LDH ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: LDH ASSAY/TIME/POINT: RATE-A 10 23 30 0 0 APP CODE: # 742 WAVE (2ND

/PRIMARY): 376 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 9 9 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 100

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 10000 10000 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: LDH CALIBRATION TYPE: LINEAR POINT: 1 SPAN POINT: 1 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 5900

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: LDH REPORT NAME: LDH DATA MODE: ON BOARD TEST NAME: LDH CTRL INTERVAL: 1000 UNIT: U/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 80-285 103-227 (2) 0.0 100 YEARS 80-285 103-227 (3) 0.0

80-285 103-227 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-1000 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 POSITION: # SAMPLE VOLUME: 9 9 9 9 9 9 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 25: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: LIPASE

Catalog # : L7503 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: LIP ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: LIP ASSAY/TIME/POINT: 2-POINT 10 28 31 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 660 546

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 195 DECREASE: # # R2: 0 INCREASE: # # R3: 65

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 10000 10000 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: LIP CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 1000 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 2000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: LIP REPORT NAME: LIPASE DATA MODE: ON BOARD TEST NAME: LIP CTRL INTERVAL: 1000 UNIT: U/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0-62 0-62 (2) 0.0 100 YEARS 0-62 0-62 (3) 0.0

0-62 0-62 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-650 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 26: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: MAGNESIUM

Catalog # : HM929-400 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: MAG ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: MAG ASSAY/TIME/POINT: 2-POINT 10 31 0 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 700 546

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 250

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: MAG CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 9000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: MAG REPORT NAME: MAGNESIUM DATA MODE: ON BOARD TEST NAME: MAG CTRL INTERVAL: 1000 UNIT: MEQ/L INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 1.3-2.5 1.3-2.5 (2) 0.0 100 YEARS 1.3-2.5 1.3-2.5 (3) 0.0

1.3-2.5 1.3-2.5 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.0-4.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 27: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: MICROALBUMIN

Catalog # : M7562-100 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: u-ALB ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: u-ALB ASSAY/TIME/POINT: 2-POINT 10 16 31 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 700 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 10 10 R1: 300 DECREASE: # # R2: 0 INCREASE: # # R3: 100

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 32000 32000 INCREASE PROZONE LIMIT: -32000 -32000 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: u-ALB CALIBRATION TYPE: NONLINEAR POINT: 6 SPAN POINT: 6 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 100 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 10000 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: -32000 32000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: u-ALB REPORT NAME: MICROALBUMIN DATA MODE: ON BOARD TEST NAME: u-ALB CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: URINE

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0.0-2.1 0.0-2.1 (2) 0.0 100 YEARS 0.0-2.1 0.0-2.1 (3) 0.0

0.0-2.1 0.0-2.1 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.5-30.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 10 10 10 10 10 10 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Rev.8-03

Page 28: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: MICROPROTEIN

Catalog # : HP782-400 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: MIPRO ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: MIPRO ASSAY/TIME/POINT: 1-POINT 10 31 0 0 0 APP CODE: # User defined WAVE (2ND

/PRIMARY): 700 600

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 300 DECREASE: # # R2: 0 INCREASE: # # R3: 0

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: MIPRO CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 7000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: MIPRO REPORT NAME: MICROPROTEIN DATA MODE: ON BOARD TEST NAME: MIPRO CTRL INTERVAL: 1000 UNIT: MG/DAY INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: URINE

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 28-141 28-141 (2) 0.0 100 YEARS 28-141 28-141 (3) 0.0

28-141 28-141 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-250 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 POSITION: # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Rev.8-03

Page 29: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: PHOSPHORUS

Catalog # : HP916-1200 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: PHOS ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: PHOS ASSAY/TIME/POINT: 2-POINT 10 15 25 0 0 APP CODE: # 748 WAVE (2ND

/PRIMARY): 700 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 5 5 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 100

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: -32000 -32000 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: PHOS CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 200 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: -1000 3000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: PHOS REPORT NAME: PHOSPHORUS DATA MODE: ON BOARD TEST NAME: PHOS CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 2.5-4.8 2.5-4.8 (2) 0.0 100 YEARS 2.5-4.8 2.5-4.8 (3) 0.0

2.5-4.8 2.5-4.8 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.0-12.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 5 5 5 5 5 5 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 30: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: RF

Catalog # : R7568 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: RF ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: RF ASSAY/TIME/POINT: APP CODE: # User defined WAVE (2ND

/PRIMARY): 700 340

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: INCREASE PROZONE LIMIT: LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: RF CALIBRATION TYPE: SPLINE POINT: SPAN POINT: WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 10000 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE:

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: RF REPORT NAME: RF DATA MODE: ON BOARD TEST NAME: RF CTRL INTERVAL: 1000 UNIT: U/ML INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 0-10 0-10 (2) 0.0 100 YEARS 0-10 0-10 (3) 0.0

0-10 0-10 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-300 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Rev.8-03

Page 31: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: TOTAL PROTEIN

Catalog # : HT928-1200 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: TP ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: TP ASSAY/TIME/POINT: 2-POINT 10 16 31 0 0 APP CODE: # 757 WAVE (2ND

/PRIMARY): 700 570

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 100

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: -32000 -32000 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: TP CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: -1000 4000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: TP REPORT NAME: TOTAL PROTEIN DATA MODE: ON BOARD TEST NAME: TP CTRL INTERVAL: 1000 UNIT: G/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 6.2-8.5 6.2-8.5 (2) 0.0 100 YEARS 6.2-8.5 6.2-8.5 (3) 0.0

6.2-8.5 6.2-8.5 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 1.0-15.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 32: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: TRIGLYCERIDES

Catalog # : HT932-1000 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: TRIG ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: TRIG ASSAY/TIME/POINT: 1-POINT 10 31 0 0 0 APP CODE: # 781 WAVE (2ND

/PRIMARY): 700 505

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 3 3 R1: 300 DECREASE: # # R2: 0 INCREASE: # # R3: 0

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: TRIG CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 200 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 4300

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: TRIG REPORT NAME: TRIGLYCERIDES DATA MODE: ON BOARD TEST NAME: TRIG CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 44-148 44-148 (2) 0.0 100 YEARS 44-148 44-148 (3) 0.0

44-148 44-148 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-1000 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 3 3 3 3 3 3 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 33: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: URIC ACID

Catalog # : HU982-615 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: UA ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: UA ASSAY/TIME/POINT: 2-POINT 10 31 0 0 0 APP CODE: # 700 WAVE (2ND

/PRIMARY): 700 505

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 8 8 R1: 250 DECREASE: # # R2: 0 INCREASE: # # R3: 50

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: UA CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 100 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: 0 6000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: UA REPORT NAME: URIC ACID DATA MODE: ON BOARD TEST NAME: UA CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 2.5-7.7 2.5-7.7 (2) 0.0 100 YEARS 2.5-7.7 2.5-7.7 (3) 0.0

2.5-7.7 2.5-7.7 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0.0-20.0 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0.0 # POSITION: # # SAMPLE VOLUME: 8 8 8 8 8 8 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 34: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION

Pointe Scientific, Inc. Analyzer: Hitachi 912 Instrument Application Test: autoHDL

Catalog # : H7545 --------------------------------------------------APPLICATION SCREEN, ANALYZE WINDOW----------------------------------------------------------------

SELECT TEST: HDL ANALYZER CYCLE TIME: 10 SEC DILUENT: 00311 0 TEST NAME: HDL ASSAY/TIME/POINT: 2-POINT 10 15 31 0 0 APP CODE: # WAVE (2ND

/PRIMARY): 700 600

SAMPLE VOLUME CLASS 1 CLASS 2 REAGENT NORMAL: 4 4 R1: 300 DECREASE: # # R2: 0 INCREASE: # # R3: 100

R4: 0 CLASS 1 CLASS 2 DEC/INC

ABS. LIMIT: 0 0 INCREASE PROZONE LIMIT: 0 0 LOWER

---------------------------------------------------APPLICATION SCREEN, CALIBRATION WINDOW---------------------------------------------------------

SELECT TEST: HDL CALIBRATION TYPE: LINEAR POINT: 2 SPAN POINT: 2 WEIGHT: 0 AUTO CALIBRATION

TIME OUT CHANGEOVER BLANK: 0 HR LOT: # SD LIMIT: 0.1 SPAN: 0 HR BOTTLE: # DUPLICATE LIMIT: 10% 20 ABS 2 POINT: 0 HR SENSITIVITY RANGE: # # FULL: 0 HR S1 ABS RANGE: -32000 32000

----------------------------------------------------APPLICATION SCREEN, RANGE WINDOW-------------------------------------------------------------------

SELECT TEST: HDL REPORT NAME: HDL DATA MODE: ON BOARD TEST NAME: HDL CTRL INTERVAL: 1000 UNIT: MG/DL INSTR. FACTOR: A = 1.0 B = 0.0 SELECT SAMPLE TYPE: SER/PL

EXPECTED RANGES: USE QUALITATIVE TABLE AGE MALE FEMALE (1) 2.999 <3.0 100 YEARS 35-55 45-65 (2) 0.0 100 YEARS 35-55 45-65 (3) 0.0

35-55 45-65 (4) 0.0 (5) 0.0

DEFAULT RANGE: OVER 100 YEARS (6) 0.0 DEFAULT SEX: MALE REPEAT RANGE: # - # CLASS 1 TECHNICAL RANGE: 0-150 CLASS 2 TECHNICAL RANGE: -99999 -99999

----------------------------------------------------APPLICATION SCREEN, OTHERS WINDOW-----------------------------------------------------------------

<STANDARD> (1) (2) (3) (4) (5) (6) CALIB. CODE: # # CONCENTRATION: 0 # POSITION: # # SAMPLE VOLUME: 4 4 4 4 4 4 DILUTED S. VOL: 0 0 0 0 0 0 DILUENT VOLUME: 0 0 0 0 0 0

# DENOTES A USER-DEFINED PARAMETER. INFORMATION IS SPECIFIC TO THE CHANNEL BEING USED, OR IT IS DETERMINED BY THE LABORATORY’S OWN PREFERENCE FOR OPERATION. It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50. Rev.8-03

Page 35: Instrument Applications/Hitachi 912... · Pointe Scientific, Inc. Analyzer: Hitachi 912. Instrument Application Test: ACID PHOS. Catalog # : HA703--------------------------------------------------APPLICATION