1 ICP Test Report Certification Packet Company name: Littelfuse, Inc. Product Series: FUSE - BF1 32V Product #: 153.5631.xxxx Series Issue Date: June 29, 2011 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Engineer> (1) Parts, sub-materials and unit parts This document covers the FUSE - BF1 RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks:. Form 585-047 Rev. A 2/21/06
87
Embed
ICP Test Report Certification Packet - Littelfuse/media/files/littelfuse/...2011/06/29 · Item No. 4) N/P 353.1115.6043 Country of Origin NP Buyer's Name NP Supplier's Name NP Date
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1
ICP Test Report Certification Packet
Company name : Littelfuse, Inc.
Product Series: FUSE - BF1 32V
Product #: 153.5631.xxxx Series
Issue Date: June 29, 2011
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive
2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
<Global EHS Engineer>
(1) Parts, sub-materials and unit parts
This document covers the FUSE - BF1 RoHS-Compliant series products manufactured by
Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:.
Form 585-047 Rev. A 2/21/06
2
Table 1: List of Raw Materials covered by this report
Total Parts Raw Material Part
Number Raw Material Description Page(s)
1 355.1115.xxxx Element - Sn Plated Wire (50-200A) 3-9
2 353.1115.xxxx Melting Wire – Sn Plated Wire (30-200A) 11-13
3 353.1590.0001 BF1 Solder 14-17
4 326.2140.0000 Colorant – Amber 18-26
5 353.2140.1000 Cover Clear 27-31
6 325.7695.0110 Colorant Yellow 32-36
7 353.2131.4600 Body Yellow (60A) 37-45
8 353.1119.xxxx Melting Wire/ Element – Sn Plated Wire
(23A-30A) 46-49
9 353.2130.xxxx
Housing BF1 – 23A (Brown Colorant – 325.7692.0610
Base 325.2131.0001) 50-69
10 353.2131.4800 Housing BF1 – (80A) 70-78
11 325.7692.0000 Colorant Natural/ white – (80A) 79-87
Report No.: MX11-0928-04
Date:2011-06-16
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
4) Base N/P 353.1115.6043
4) Plated N/P 353.1115.6043
TEST RESULT SUMMARY FOR RoHS DIRECTIVE :
TESTING ITEM
Ω RESULT (ppm) Limit (4)
Base
(4)
Plated
Cadmium (Cd) content ND ND 0,01% (100 ppm)
Lead (Pb) content 14,19 78,26 0,1% (1000 ppm)
Mercury (Hg) content ND ND 0,1% (1000 ppm)
Chromium (VI) (Cr6+
) ND ND 0,1% (1000 ppm)
ppm = parts per million based on dry weight of sample.
µg/cm2 = microgram per square centimeter.
mg/kg WITH 50cm2 = milligram per kilogram with 50 square centimeter.
< = less than.
ND = Not detected.
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. These Accreditations only apply for the methods listed in such. Not accredited under EMA Ω.
Prepared and checked by:
For Intertek Laboratory Manager
The Official Mexican Standard NOM-008-SCFI-1993 establishes like separator decimal the comma (,).
NOTE : DecaBDE IN POLYMERIC APPLICATIONS IS EXEMPTED ACCORDING TO ROHS DIRECTIVE AMENDMENT 2005/717/EC.
# =ACCORDING TO IEC 62321, A POSITIVE RESULT INDICATES THE PRESENCE OF Cr(VI) COATING. IT IS THE Cr(VI) CONCENTRATION DETECTED IN THE BOILING-WATER-EXTRACTION SOLUTION AND SHOULD NOT BE INTERPRETED AS THE Cr(VI) CONCENTRATION IN THE COATING LAYER OF THE SAMPLE. REMARK : AS REQUESTED BY THE APPLICANT, COATING WITH BASE MATERIAL OF TESTED COMPONENTS OF THE SAMPLE MX11-0928-04 WERE TESTED SEPARATED.
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
4 Chromium VI (Cr
6+)
content With reference to USEPA 3060, by EPA 7196
QHU2010-61p73 2011-05-13 MELA 20,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
4 (Base) Lead (Pb) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 5,0
4 (Plated) Lead (Pb) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 41,67
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
4 (Base) Cadmium (Cd) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 2,0
4 (Plated) Cadmium (Cd) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 16,7
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
4 (Base) Mercury (Hg) content With reference to USEPA 7471 by USEPA 7471 MET2010-40p126 2011-05-10 RNC 0,25
4 (Plated) Mercury (Hg) content With reference to USEPA 7471 by USEPA 7471 MET2010-40p126 2011-05-10 RNC 2,5
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
6) Base BFI SOLDER N/P 353.1590.0001
6) Plated BFI SOLDER N/P 353.1590.0001
TEST RESULT SUMMARY FOR RoHS DIRECTIVE :
TESTING ITEM
Ω RESULT (ppm) Limit (6)
Base
(6)
Plated
Cadmium (Cd) content ND ND 0,01% (100 ppm)
Lead (Pb) content 344,6 69,33 0,1% (1000 ppm)
Mercury (Hg) content ND ND 0,1% (1000 ppm)
Chromium (VI) (Cr6+
) ND ND 0,1% (1000 ppm)
ppm = parts per million based on dry weight of sample.
µg/cm2 = microgram per square centimeter.
mg/kg WITH 50cm2 = milligram per kilogram with 50 square centimeter.
< = less than.
ND = Not detected.
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. These Accreditations only apply for the methods listed in such. Not accredited under EMA Ω.
Prepared and checked by:
For Intertek Laboratory Manager
The Official Mexican Standard NOM-008-SCFI-1993 establishes like separator decimal the comma (,).
NOTE : DecaBDE IN POLYMERIC APPLICATIONS IS EXEMPTED ACCORDING TO ROHS DIRECTIVE AMENDMENT 2005/717/EC.
# =ACCORDING TO IEC 62321, A POSITIVE RESULT INDICATES THE PRESENCE OF Cr(VI) COATING. IT IS THE Cr(VI) CONCENTRATION DETECTED IN THE BOILING-WATER-EXTRACTION SOLUTION AND SHOULD NOT BE INTERPRETED AS THE Cr(VI) CONCENTRATION IN THE COATING LAYER OF THE SAMPLE. REMARK : AS REQUESTED BY THE APPLICANT, COATING WITH BASE MATERIAL OF TESTED COMPONENTS OF THE SAMPLE MX11-0928-06 WERE TESTED SEPARATED.
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
6 Chromium VI (Cr
6+)
content With reference to USEPA 3060, by EPA 7196
QHU2010-61p73 2011-05-13 MELA 20,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
6 (Base) Lead (Pb) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 5,0
6 (Plated) Lead (Pb) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 50,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
6 (Base) Cadmium (Cd) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 2,0
6 (Plated) Cadmium (Cd) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 20,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
6 (Base) Mercury (Hg) content With reference to USEPA 7471 by USEPA 7471 MET2010-40p126 2011-05-10 RNC 0,25
6 (Plated) Mercury (Hg) content With reference to USEPA 7471 by USEPA 7471 MET2010-40p126 2011-05-10 RNC 2,5
AUTHORIZED BY: ON BEHALF OF INTERTEK TESTING SERVICES TAIWAN LIMITED
K. Y. LIANG DIRECTOR
THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL, WITHOUT THE WRITTEN APPROVAL OF THE LABORATORY.
PAGE 1 OF 9
,
!"#$%&$$'%()(%*+!"#$%&$$'%'
APPLICANT: LITTELFUSE, INC. DATE : JAN 19, 2009 800 E. NORTHWEST HWY
DESPLAINES IL 60016
SAMPLE DESCRIPTION: ONE (1) GROUP OF SUBMITTED SAMPLES SAID TO BE : PART DESCRIPTION : COLORANT AMBER PART NUMBER : 326.2140.0000 FACILITY : DUNSEN DATE SAMPLE RECEIVED : JAN 14, 2009 DATE TEST STARTED : JAN 14, 2009 ***************************************************************************
TEST CONDUCTED: AS REQUESTED BY THE APPLICANT, FOR DETAILS PLEASE REFER TO ATTACHED PAGES. ***************************************************************************
NUMBER : TWNC00104294
TEST CONDUCTED
PAGE 2 OF 9
,
!"#$%&$$'%()(%*+!"#$%&$$'%'
() TEST RESULT SUMMARY : RESULT (ppm)
TESTING ITEM CLEAR AMBER PLASTIC BEAN
HEAVY METALCADMIUM (Cd) CONTENT ND LEAD (Pb) CONTENT ND MERCURY (Hg) CONTENT ND CHROMIUM VI (Cr6+) CONTENT ND
() TEST METHOD : TESTING ITEM TESTING METHOD REPORTING LIMIT
CADMIUM (Cd) CONTENT
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 8/9/10, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
LEAD (Pb) CONTENT
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 8/9/10, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
MERCURY (Hg) CONTENT
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 7, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
CHROMIUM VI (Cr6+)CONTENT
WITH REFERENCE TO USEPA 3060A & 7196A, BY ALKALINE DIGESTION AND DETERMINED BY UV-VIS SPECTROPHOTOMETER
1 ppm
POLYBROMINATEDBIPHENYLS (PBBs)
WITH REFERENCE TO IEC 62321-111/95/CDV IN ANNEX A, BY SOLVENT EXTRACTION AND DETERMINED BY GC-MSD AND FURTHER HPLC CONFIRMATION WHEN NECESSARY
CONCENTRATE THE EXTRACT AND MAKE UP WITH ORGANIC SOLVENT
ANALYZED BY GC-MSD
NUMBER : TWNC00104294
TEST CONDUCTED
PAGE 8 OF 9
,
!"#$%&$$'%()(%*+!"#$%&$$'%'
() MEASUREMENT FLOWCHART:
TEST FOR HALOGEN CONTENT REFERENCE STANDARDEN 14582
******************************************************************************END OF REPORT
ADD ABSORBENT IN A COMBUSTION FLASK & PLACE WEIGHED SAMPLE IN EQUIPMENT
FILL THE COMBUSTION FLASK WITH OXYGEN
IGNITE THEN LEAVE THE FLASK AT ROOM TEMPERATURE
TRANSFER THE ABSORBENT INTO A VOLUMETRIC FLASK
MAKE UP WITH DEIONIZED WATER
SAMPLING/GRINDING OR CUTTING
ANALYZED BY ION CHROMATOGRAPHY
NUMBER : TWNC00104294
TEST CONDUCTED
PAGE 9 OF 9
,
!"#$%&$$'%()(%*+!"#$%&$$'%'
PHOTO
Report No.: MX11-0928-08
Date:2011-06-16
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
Samples:
8) Cover Clear N/P 353.2140.1000
TEST RESULT SUMMARY FOR RoHS DIRECTIVE :
TESTING ITEM Ω RESULT (ppm)
Limit (8)
Cadmium (Cd) content ND 0,01% (100 ppm)
Lead (Pb) content ND 0,1% (1000 ppm)
Mercury (Hg) content ND 0,1% (1000 ppm)
Chromium (VI) (Cr6+
) ND 0,1% (1000 ppm)
POLYBROMINATED BIPHENYLS (PBBs) Total ND 0,1% (1000 ppm)
Monobromobiphenyl (MonoBB) ND ---
Dibromobiphenyl (DiBB) ND ---
Tribromobiphenyl (TriBB) ND ---
Tetrabromobiphenyl (TetraBB) ND ---
Pentabromobiphenyl (PentaBB) ND ---
Hexabromobiphenyl (HexaBB) ND ---
Heptabromobiphenyl (HeptaBB) ND ---
Octabromobiphenyl (OctaBB) ND ---
Nonabromobiphenyl (NonaBB) ND ---
Decabromobiphenyl (DecaBB) ND ---
POLYBROMINATED DIPHENYL ETHERS (PBDEs) Total ND 0,1% (1000 ppm)
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
|ppm = parts per million based on dry weight of sample.
µg/cm2 = microgram per square centimeter.
mg/kg WITH 50cm2 = milligram per kilogram with 50 square centimeter.
< = less than.
ND = Not detected.
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. These Accreditations only apply for the methods listed in such. Not accredited under EMA Ω.
Prepared and checked by:
For Intertek Laboratory Manager
The Official Mexican Standard NOM-008-SCFI-1993 establishes like separator decimal the comma (,).
NOTE :DecaBDE IN POLYMERIC APPLICATIONS IS EXEMPTED ACCORDING TO ROHS DIRECTIVE AMENDMENT 2005/717/EC.
# =ACCORDING TO IEC 62321, A POSITIVE RESULT INDICATES THE PRESENCE OF Cr(VI) COATING. IT IS THE Cr(VI) CONCENTRATION DETECTED IN THE BOILING-WATER-EXTRACTION SOLUTION AND SHOULD NOT BE INTERPRETED AS THE Cr(VI) CONCENTRATION IN THE COATING LAYER OF THE SAMPLE. REMARK : AS REQUESTED BY THE APPLICANT, COATING WITH BASE MATERIAL OF TESTED COMPONENTS OF THE SAMPLE MX11-0928-08 WERE TESTED TOGETHER.
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
8 Chromium VI (Cr
6+)
content With reference to USEPA 3060, by EPA 7196
QHU2010-61p73 2011-05-13 MELA 20,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
8
POLYBROMINATE
D BIPHENYLS
(PBBs)
Determined by GC-MSD 2011-000274-PCL 2011-05-18
CONT 50,0
8
POLYBROMINATED DIPHENYL ETHERS (PBDEs)
Determined by GC-MSD 2011-000274-PCL 2011-05-18
CONT 50,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
8 Lead (Pb) content With reference to USEPA 3052, by EPA 6010 MET2010-40p128 2011-05-11 MARY 5,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
8 Cadmium (Cd) content With reference to USEPA 3052, by EPA 6010 MET2010-40p128 2011-05-11 MARY 2,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
8 Mercury (Hg) content With reference to USEPA 7471 by USEPA 7471 MET2010-40p125 2010-05-10 RNC 0,25
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
Samples:
1) Colorant yellow N/P 325.7695.0110
TEST RESULT SUMMARY FOR RoHS DIRECTIVE :
TESTING ITEM Ω RESULT (ppm)
Limit (1)
Cadmium (Cd) content ND 0,01% (100 ppm)
Lead (Pb) content 12,76 0,1% (1000 ppm)
Mercury (Hg) content ND 0,1% (1000 ppm)
Chromium (VI) (Cr6+
) ND 0,1% (1000 ppm)
POLYBROMINATED BIPHENYLS (PBBs) Total ND 0,1% (1000 ppm)
Monobromobiphenyl (MonoBB) ND ---
Dibromobiphenyl (DiBB) ND ---
Tribromobiphenyl (TriBB) ND ---
Tetrabromobiphenyl (TetraBB) ND ---
Pentabromobiphenyl (PentaBB) ND ---
Hexabromobiphenyl (HexaBB) ND ---
Heptabromobiphenyl (HeptaBB) ND ---
Octabromobiphenyl (OctaBB) ND ---
Nonabromobiphenyl (NonaBB) ND ---
Decabromobiphenyl (DecaBB) ND ---
POLYBROMINATED DIPHENYL ETHERS (PBDEs) Total ND 0,1% (1000 ppm)
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
|ppm = parts per million based on dry weight of sample.
µg/cm2 = microgram per square centimeter.
mg/kg WITH 50cm2 = milligram per kilogram with 50 square centimeter.
< = less than.
ND = Not detected.
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. These Accreditations only apply for the methods listed in such. Not accredited under EMA Ω.
Prepared and checked by:
For Intertek Laboratory Manager
The Official Mexican Standard NOM-008-SCFI-1993 establishes like separator decimal the comma (,).
NOTE :DecaBDE IN POLYMERIC APPLICATIONS IS EXEMPTED ACCORDING TO ROHS DIRECTIVE AMENDMENT 2005/717/EC.
# =ACCORDING TO IEC 62321, A POSITIVE RESULT INDICATES THE PRESENCE OF Cr(VI) COATING. IT IS THE Cr(VI) CONCENTRATION DETECTED IN THE BOILING-WATER-EXTRACTION SOLUTION AND SHOULD NOT BE INTERPRETED AS THE Cr(VI) CONCENTRATION IN THE COATING LAYER OF THE SAMPLE. REMARK : AS REQUESTED BY THE APPLICANT, COATING WITH BASE MATERIAL OF TESTED COMPONENTS OF THE SAMPLE MX11-0928-01 WERE TESTED TOGETHER.
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
1 Chromium VI (Cr
6+)
content With reference to USEPA 3060, by EPA 7196
QHU2010-61p73 2011-05-13 MELA 20,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
1
POLYBROMINATE
D BIPHENYLS
(PBBs)
Determined by GC-MSD 2011-000274-PCL 2011-05-18
CONT 50,0
1
POLYBROMINATED DIPHENYL ETHERS (PBDEs)
Determined by GC-MSD 2011-000274-PCL 2011-05-18
CONT 50,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
1 Lead (Pb) content With reference to USEPA 3052, by EPA 6010 MET2010-40p128 2011-05-11 MARY 5,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
1 Cadmium (Cd) content With reference to USEPA 3052, by EPA 6010 MET2010-40p128 2011-05-11 MARY 2,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
1 Mercury (Hg) content With reference to USEPA 7471 by USEPA 7471 MET2010-40p125 2010-05-10 RNC 0,25
AUTHORIZED BY: ON BEHALF OF INTERTEK TESTING SERVICES TAIWAN LIMITED
K. Y. LIANG DIRECTOR
THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL, WITHOUT THE WRITTEN APPROVAL OF THE LABORATORY.
PAGE 1 OF 9
!"#$%&$$'%()(%* +!"#$%&$$'%''$$'%'
APPLICANT: LITTELFUSE, INC. DATE : JAN 22, 2009 800 E. NORTHWEST HWY
DESPLAINES IL 60016
SAMPLE DESCRIPTION: ONE (1) GROUP OF SUBMITTED SAMPLES SAID TO BE : PART DESCRIPTION : BODY 60A YELLOW PART NUMBER : 353.2131.4600 FACILITY NAME : DUNSEN DATE SAMPLE RECEIVED : JAN 19, 2009 DATE TEST STARTED : JAN 19, 2009 ***************************************************************************
TEST CONDUCTED: AS REQUESTED BY THE APPLICANT, FOR DETAILS PLEASE REFER TO ATTACHED PAGES. ***************************************************************************
NUMBER : TWNC00104893
TEST CONDUCTED
PAGE 2 OF 9
!"#$%&$$'%()(%* +!"#$%&$$'%''$$'%'
() TEST RESULT SUMMARY : RESULT (ppm)
TESTING ITEMYELLOW PLASTIC
HEAVY METALCADMIUM (Cd) CONTENT ND LEAD (Pb) CONTENT 18 MERCURY (Hg) CONTENT ND CHROMIUM VI (Cr6+) CONTENT ND
() TEST METHOD : TESTING ITEM TESTING METHOD REPORTING LIMIT
CADMIUM (Cd) CONTENT
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 8/9/10, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
LEAD (Pb) CONTENT
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 8/9/10, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
MERCURY (Hg) CONTENT
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 7, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
CHROMIUM VI (Cr6+)CONTENT
WITH REFERENCE TO USEPA 3060A & 7196A, BY ALKALINE DIGESTION AND DETERMINED BY UV-VIS SPECTROPHOTOMETER
1 ppm
POLYBROMINATEDBIPHENYLS (PBBs)
WITH REFERENCE TO IEC 62321-111/95/CDV IN ANNEX A, BY SOLVENT EXTRACTION AND DETERMINED BY GC-MSD AND FURTHER HPLC CONFIRMATION WHEN NECESSARY
CONCENTRATE THE EXTRACT AND MAKE UP WITH ORGANIC SOLVENT
ANALYZED BY GC-MSD
NUMBER : TWNC00104893
TEST CONDUCTED
PAGE 8 OF 9
!"#$%&$$'%()(%* +!"#$%&$$'%''$$'%'
() MEASUREMENT FLOWCHART:
TEST FOR HALOGEN CONTENT REFERENCE STANDARDEN 14582
******************************************************************************END OF REPORT
ADD ABSORBENT IN A COMBUSTION FLASK & PLACE WEIGHED SAMPLE IN EQUIPMENT
FILL THE COMBUSTION FLASK WITH OXYGEN
IGNITE THEN LEAVE THE FLASK AT ROOM TEMPERATURE
TRANSFER THE ABSORBENT INTO A VOLUMETRIC FLASK
MAKE UP WITH DEIONIZED WATER
SAMPLING/GRINDING OR CUTTING
ANALYZED BY ION CHROMATOGRAPHY
NUMBER : TWNC00104893
TEST CONDUCTED
PAGE 9 OF 9
!"#$%&$$'%()(%* +!"#$%&$$'%''$$'%'
PHOTO
Report No.: MX11-0928-03
Date:2011-06-16
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
3) Base Element Sn Plated Copper N/P 353.1119.4043
3) Plated Element Sn Plated Copper N/P 353.1119.4043
TEST RESULT SUMMARY FOR RoHS DIRECTIVE :
TESTING ITEM
Ω RESULT (ppm) Limit (3)
Base
(3)
Plated
Cadmium (Cd) content ND ND 0,01% (100 ppm)
Lead (Pb) content 36,10 148,1 0,1% (1000 ppm)
Mercury (Hg) content ND ND 0,1% (1000 ppm)
Chromium (VI) (Cr6+
) ND ND 0,1% (1000 ppm)
ppm = parts per million based on dry weight of sample.
µg/cm2 = microgram per square centimeter.
mg/kg WITH 50cm2 = milligram per kilogram with 50 square centimeter.
< = less than.
ND = Not detected.
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. These Accreditations only apply for the methods listed in such. Not accredited under EMA Ω.
Prepared and checked by:
For Intertek Laboratory Manager
The Official Mexican Standard NOM-008-SCFI-1993 establishes like separator decimal the comma (,).
NOTE : DecaBDE IN POLYMERIC APPLICATIONS IS EXEMPTED ACCORDING TO ROHS DIRECTIVE AMENDMENT 2005/717/EC.
# =ACCORDING TO IEC 62321, A POSITIVE RESULT INDICATES THE PRESENCE OF Cr(VI) COATING. IT IS THE Cr(VI) CONCENTRATION DETECTED IN THE BOILING-WATER-EXTRACTION SOLUTION AND SHOULD NOT BE INTERPRETED AS THE Cr(VI) CONCENTRATION IN THE COATING LAYER OF THE SAMPLE. REMARK : AS REQUESTED BY THE APPLICANT, COATING WITH BASE MATERIAL OF TESTED COMPONENTS OF THE SAMPLE MX11-0928-03 WERE TESTED SEPARATED.
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. ILTA/003/GENS-F8
Intertek Testing Services de México, S.A. de C.V. Poniente 134 No. 660, Col. Industrial Vallejo
C.P. 02300, Del. Azcapotzalco, México, D.F. Tel.: 50912150
www.intertek.com
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
3 Chromium VI (Cr
6+)
content With reference to USEPA 3060, by EPA 7196
QHU2010-61p73 2011-05-13 MELA 20,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
3 (Base) Lead (Pb) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 5,0
3 (Plated) Lead (Pb) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 50,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
3 (Base) Cadmium (Cd) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 2,0
3 (Plated) Cadmium (Cd) content With reference to USEPA 3050MOD, by EPA 6010 MET2010-40p129 2011-05-11 MARY 20,0
Sample Number
Testing item Ω Testing method Quality control
Batch: Analysis
Date:
Analyzed
By:
Reporting limit ppm
3 (Base) Mercury (Hg) content With reference to USEPA 7471 by USEPA 7471 MET2010-40p126 2011-05-10 RNC 0,25
3 (Plated) Mercury (Hg) content With reference to USEPA 7471 by USEPA 7471 MET2010-40p126 2011-05-10 RNC 2,5
APPLICANT: LITTELFUSE, INC. DATE : JAN 21, 2009 800 E. NORTHWEST HWY
DESPLAINES IL 60016
SAMPLE DESCRIPTION:
ONE (1) GROUP OF SUBMITTED SAMPLES SAID TO BE : PART DESCRIPTION : BODY 80A NATURAL PART NUMBER : 353.2131.4800 FACILITY NAME : DUNSEN DATE SAMPLE RECEIVED : JAN 19, 2009 DATE TEST STARTED : JAN 19, 2009 ***************************************************************************
TEST CONDUCTED:
AS REQUESTED BY THE APPLICANT, FOR DETAILS PLEASE REFER TO ATTACHED PAGES. ***************************************************************************
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 8/9/10, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
LEAD (Pb) CONTENT
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 8/9/10, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
MERCURY (Hg) CONTENT
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 7, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
CHROMIUM VI (Cr6+) CONTENT
WITH REFERENCE TO USEPA 3060A & 7196A, BY ALKALINE DIGESTION AND DETERMINED BY UV-VIS SPECTROPHOTOMETER
1 ppm
POLYBROMINATED BIPHENYLS (PBBs)
WITH REFERENCE TO IEC 62321-111/95/CDV IN ANNEX A, BY SOLVENT EXTRACTION AND DETERMINED BY GC-MSD AND FURTHER HPLC CONFIRMATION WHEN NECESSARY
APPLICANT: LITTELFUSE, INC. DATE : JAN 19, 2009 800 E. NORTHWEST HWY
DESPLAINES IL 60016
SAMPLE DESCRIPTION:
ONE (1) GROUP OF SUBMITTED SAMPLES SAID TO BE : PART DESCRIPTION : COLORANT WIHTE PART NUMBER : 325.7692.0000 FACILITY : DUNSEN DATE SAMPLE RECEIVED : JAN 14, 2009 DATE TEST STARTED : JAN 14, 2009 ***************************************************************************
TEST CONDUCTED:
AS REQUESTED BY THE APPLICANT, FOR DETAILS PLEASE REFER TO ATTACHED PAGES. ***************************************************************************
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 8/9/10, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
LEAD (Pb) CONTENT
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 8/9/10, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
MERCURY (Hg) CONTENT
WITH REFERENCE TO IEC 62321-111/95/CDV IN CLAUES 7, BY MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES
2 ppm
CHROMIUM VI (Cr6+) CONTENT
WITH REFERENCE TO USEPA 3060A & 7196A, BY ALKALINE DIGESTION AND DETERMINED BY UV-VIS SPECTROPHOTOMETER
1 ppm
POLYBROMINATED BIPHENYLS (PBBs)
WITH REFERENCE TO IEC 62321-111/95/CDV IN ANNEX A, BY SOLVENT EXTRACTION AND DETERMINED BY GC-MSD AND FURTHER HPLC CONFIRMATION WHEN NECESSARY