1 ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Pico Product #: 473L Series Issue Date: August 29, 2013 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC, 2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Specialist> (1) Parts, sub-materials and unit parts This document covers the Pico RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: Pb (lead) contained in the high temperature melting solder > 85% and is categorized as exempt under section 7a of the RoHS Annex. Form 585-047 Rev. A 2/21/06
80
Embed
ICP Test Report Certification Packet - Littelfuse/media/files/littelfuse...1 ICP Test Report Certification Packet Company name: Littelfuse, Inc. Product Series: Pico Product #: 473L
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1
ICP Test Report Certification Packet
Company name : Littelfuse, Inc.
Product Series: Pico
Product #: 473L Series
Issue Date: August 29, 2013
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC,
2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
<Global EHS Specialist>
(1) Parts, sub-materials and unit parts
This document covers the Pico RoHS-Compliant series products manufactured by
Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:
Pb (lead) contained in the high temperature melting solder > 85% and is categorized as
exempt under section 7a of the RoHS Annex.
Form 585-047 Rev. A 2/21/06
2
Table 1: List of Raw Materials covered by this report
Total Parts Raw Material Part Number Raw Material Description Page(s) 1 SIKOR 410 (909-371) Ceramic Tube - Body 3-31
2 082xxx-001 Element – Cu99.9MSn 32-35
3 RK-3-K71 (692320) Solder 36-41
4 910-xxx (910-271) Caps & Lead Assay 42-47
5 648102 Yarn 48-54
6 648106-001 Yarn 55-62
7 648112-001 Yarn 63-70
8 087234
(old part number 087340) Epoxy Powder (HF Gold) 71-80
Tho following sample(s) wae/were submitted and identifiod by/on behalf of the client as:
Test RePortCERAMTEC GMBHGESCHAFTSBEREICH
Sample DescriptionStyle/ltem No.Sample Receiving DateTesting Period
CERAMICstKoR c41020131111420131 1 l1 4 r o 2013101 122
Please rcfer to next Page(s)
Bas€d on th€ perfomed tes15 on submitted-samples the test results of CaTilt: llf Iill."". i"riuur""t cnromium cr(vt), pBBs and PBDES comply with the limits as set Dy'*iilt
5]rJJ" ior'trcsiEu Annex ll: recastins 200295/Ec
TeBt R€6ult(s)
Concluslon
{tsrw4)
glnd f!. r|d oatlsatst|Iwal{ LlD.
Test RePort No.: CE/2013/'13197 Dale,2113101122 Page:2 d 29
mg/Kg !{tith reference to US EPA 5021method. Analy8is wa6 Perfomed bYGC/MS.
n.d.
iEiI13-Dichloropropene(cASNo.:10061-02€)
mdks With reterence to US EPA 5021method. Analysis was Perfo.med bYGC/MS.
n-o.
Trichloroethylene (CAS No.: 7$01"6)
mg/Kg With reference to US EPA 5021method. Analysis was Perfomed bYGC/MS.
1 n.d.
sum ot PBB8 msyKg5
n.o, 1000n.d.
Monoblomobiphenyl m!yKg
Dibromobiphenyl mg/kg n.d.
5 n.d.Tribromobiphenyl m9Kg
fet€bromobiPhenyl mg/kg 5 n.d.n.d.
PentabrcmobiPhenyl mgKgn.d.
Hexabromobiphenyl mg/Kg
Heptabromobiphenyl mg/kg 5 n.o.5 n.d.
Octabrornobiphenyl mgKg5 n.d.
NonabromobiPhenYl mg/Kgn.d.
Oecabromobiphenyl mg/kgn.d. '1000
surn of PBDES mgKg5 n.d.
Monobromodiphenyl ether mgKg5 n.d.
Dibrcmodiphenyl ether mg/Kg5 n.d-
iribromodiphenyl ether mgikg5 n-o.
TetrabromodiPhenYl ether mg/K95 n.d.
Pentabromodiphenyl ether mgKg5 n.d.
HexabromodiPhenyl ether mdkg5 n.d.
FeDtabromodiphenyl ether mgKg5 n.d.
Octabromodiphenyl ether mg./Kg5 n.d-
FonabromodiPhenylether mg/Kg5 n.d.
becabrornodiPhenyl ether mgftg
i$ii-&1ff;ri'#F,[liilH.fi;,"]:f,ff:tury'jiH:TTi:Tii:::liiiifffi[ff"*ffi;.iffi.ffi'll#;ffiiil;j#Tl"sj:il+ffi-##*i1ffi k"#;l"{:ffi i:i*$#,H*tr#;iF'll'ilex;It j{i,Hrilils",}ff hi:#ri j,*e#ji:T#.["I#td";iLf f p.mmq:,ffi :lr*p.l:jrugmffi,*r,r,-;iit*"i'*,**rffi,[$,$:Ai idi!#S'r]iitii;"i$',S*#$ge{ii::silFlltF+€i}'sT'$Si#,dtttulllll;#iiilB;;"rir"*r.i#:xii;'J**:#ur5""pffr*c:N4fuiFi . l /Tdw.dl l j
i;;p.ni tuy -*'ho-d,b.d- be'"/-
Test RePort No. : CE201 3/1 31 97 DaIe | 2O13lUn2 Page : 1 3 of 29
lll| tl]llllllllCERAMTEC GMBHGESCHAFTSBEREICH
Noto :
PFOS Refercnce Information : POPS - (EU) 7572010
Outlawtng PFOS as substances or preparations inadicles o; oarts at a tevel above 0 1%('1000ppm)
MULTIFUNKTIONSKEMMIK,LUITPOLDSTMBE 15, 91207 LAUF
concentrations above O OOIo/o (1Oppm)' in semi-finished producls or
in textiles or other coatgd materials above 1Fg/m'
1. mg/kg = ppm : 0.1wt% = 1000PPm
2. n.d. = Not Detected3. MOL = Method Detection Limit
4 . " - "=No tRegu la ted5. '* = Qualitative analysis (No Unit)
qualitative analysis i6 from less than O 1olo to 1OO% The judgment criterion: asbestos fibers'u"ingio*d' i""n**"s"Posit ive';asbestosfibersnotbeingfoundisshownas"Negative'-
!$i,il4jirT:..[fi1jiHtj#1ffi*l]i:*H;1',:ili"Jilktrif"i'.,i:,:J#;,'ffiil;'*ruiJ:,il#J*'li[if*r{#H*fr;#.i'r+ri:+iAii*['';i;ti*Fgftii$.*""w"lssffi:'jii+-p#;-YE:l*;q,,'i"ii*t#"fl'#ir';"r:;l;rin"+q"r+'d:;i""*1il'iiii:r:hf:t!,'i*i;.t, :1i+'.tr.:$.x;: ilils,i':iliiei:ilfr!ff .ffii!ri#*#*{t:l';".sr::E}t ?ii{'S!i':*T*., ii'i;l$,*Tf.tr':#ii{'i*$ii*}Tii}ilq##;'i#,{#"s},*:*1f"'l##iiiB:#ir;*+*ii*i::$'*:r;r"":rs;""#'nr'gr;i;;p;ry ev
"n.dhod.d ar.'dim
Test Report No.:CE/2013i/13197 Oetrie:2O13t01122 Page: '14 of 29
f t ' l ' , : I ; -" , . ; "* . .1. . . ; , . .* ," ;**" . ; i " . ,1 '"") ; ' ' "**;"" ' ' ""- i . , - , ' "" ' "" ' ! "o, .dor** 'h,aa"*q!€-Fi i,ii6iniii;i"in-.n'"i,*.me;;Fnb'i*'ancod@*.,FbdTn'-oo@ft*dM.!!@_'€finisLo;c.dw 'o-'t '." *d in$dr ,$u.5 de ldhe'e. a.v lo@ dr'ffitm ' tadls- "i'crh'co' prv\'rdrssal
miie o r ' 'a*"nq -tv * *hi tr€,m'Bd. r*nraMs tn' F"corr?"so'.6,@1rh'i - ] " i . " " " m ' * e o s t r E , r - ' , q ' o 1 o c J F n . i E o m 1 @ . r oi;;;;;; ;;;ifdd;tr;i;d: 'd!"t ;ii;i;6d* .r h. -ed
". i , r { . r r f r ; 3 3 \ . j
Samole ore-trealment
Sample analyzed by FTIR
Check wave-numbea of C-Clbonding
Test RePortCERAIiITEC GMBHGESCHAFTSBEREICH
No. : CE/201313197Dale :2013101122 Page : 26 of 29
1) Name ofthe Derson who made measu€ment:Rita Chen2) Name of the person in charge of measurement Troy Chang
rl|fittl ttlll
Sample pretreatment / Separation
Weighting and putting 6ample in cell
Orygen Bomb Combustion / Absorption
Dilution to fixed volume
Analysis wa6 per{ormed by lC
ifr '"""$"".,.";,""-."'""**..'I".""i**.'. i"l;:i".f;Ti'"T,lir:;r+s:"r#{*ra.:::l;.l1!",::t:.'a*l;;.?i'.;'L: -v'r;T;;i."1ffii.1::;its:"ft""f.:D"$;;3'ir:i;t* .:ti i ; ; ; i ; ; , ; ; 1 . ; ; . ' ; 1 ; ; n ' j t r eabdc€a t , n . [ do ' ' i ; t . t conp , j / . ' o "? ' r c -o ' 1' - ?d , r @@-m. :biJiii, ']d".i,^;'r'"i ' 'doi.rr"'"t-ib@;''hisfcat-dLha@;b.;i;,66neol'hisdo4mmlism|*/flaiaonderybep]o3eodediob
Test Report No. : CEl2013/13197Oale:2013101n2 Page : 28 of 29
As requested by the applicant, for details refer to attached page(s). ************************************************************************************************************************************************************
To be continued
Test Report Number: SHAH00361401
Tests Conducted
Page 2 Of 4 Intertek Testing Services Ltd., Shanghai
The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material.
(Ⅲ) Test Method:
Testing item T esting method R eporting limit
Cadmium (Cd) content With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Lead (Pb) content With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Mercury (Hg) content With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Chromium VI (Cr6+) content With reference to IEC 62321 edition 1.0:2008 in Annex B, by boiling water extraction and determined by UV-VIS Spectrophotometer.
0.02 mg/kg with 50cm2
Remark:Reporting limit = Quantitation limit of analyze in sample Date Sample Received:Jan.9, 2013 Testing Period:Jan.9, 2013 to Jan.14, 2013
************************************************************************************************************************************************************ To be continued
Test Report Number: SHAH00361401
Tests Conducted
Page 3 Of 4 Intertek Testing Services Ltd., Shanghai
(Ⅳ) MEASUREMENT FLOWCHART: Test for Cd/ Pb/ Hg/Cr (VI)/ PBBs/PBDEs contents Reference standard: IEC 62321 edition 1.0:2008 REMARKS: *1: LIST OF APPROPRIATE ACID:
MATERIAL ACID ADDED FOR DIGESTION Polymers HNO 3,HCl,HF,H2O2,H3BO3 Metals HNO 3,HCL,HF Electronics H NO3,HCL,H2O2,HBF4
*2: IF THE RESULT OF SPOT TEST IS POSITIVE, CHROMIUM (VI) WOULD BE DETERMINED AS DETECTED. ************************************************************************************************************************************************************
To be continued
Sampling/grinding or cutting
Weigh sample and for different material,
digest the sample with appropriate acid*1
Make up with deionized water
Cd/Pb/Hg
Analyzed by ICP-OES
Weigh sample and add alkaline
solution
Definite temp. Extraction
Make up with deionized water and add Diphenyl-
carbazide solution
Cr6+
Weigh sample andadd organic
solvent
Soxhlet extractionor
Solvent extraction
Concentrate the extract and make up with organic
solvent
PBBs/PBDEs
Analyzed by UV-VIS
Analyzed by GC-MSD
Spot test
Get 50cm2 samples
Boiling water extraction
Metal Polymers / electronics
Negative*2
Confirm the tested samples are totally
dissolved
No
Cool and filter the extract
Yes
Test Report Number: SHAH00361401
Tests Conducted
Page 4 Of 4 Intertek Testing Services Ltd., Shanghai
End of report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.
Test Report Number : TWNC00294413
Authorized by: On Behalf of Intertek Testing Services Taiwan Limited
Applicant: Littelfuse Philippines Inc. Date : Jan 17, 2013 LIMA Technology Center, Lipa City,
Malvar, Batangas
Sample Description:
One (1) group of submitted samples said to be : Part Description : Solder Part Number : 692320 Date Sample Received : Jan 11, 2013 Date Test Started : Jan 11, 2013
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES.
ND 2
Lead (Pb) content ppm
With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES.
882771 2
Mercury (Hg) content ppm
With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES.
ND 2
Chromium VI (Cr6+) content mg/kg with 50 cm2
With reference to IEC 62321: 2008, by boiling water extraction and determined by UV-Vis Spectrophotometer.
Negative 0.02
Remarks: ppm = parts per million based on weight of tested sample = mg/kg
ND = Not detected
RL = Reporting Limit, Quantitation limit of analyte in sample mg/kg with 50cm2 = milligram per kilogram with 50 square centimeter
Negative = A negative test result indicated positive observation was not found at the time of Test. When the spot test showed a negative result, the boiling water extraction procedure shall be used to verify the result.
Responsibility of Chemist: Kevin Liu/ Irene Chiou Date Sample Received : Jan 11, 2013 Test Period : Jan 11, 2013 To Jan 16, 2013
Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as
detected.
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.
Applicant: Littelfuse Philippines Inc. Date : Dec 20, 2012 LIMA Technology Center, Lipa City,
Malvar, Batangas
Sample Description: One (1) group of submitted samples said to be : Part Description : Caps & Leads Part Number : 910-271 Date Sample Received : Dec 06, 2012 Date Test Started : Dec 13, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Lead (Pb) content ND 115 ND ND Mercury (Hg) content ND ND ND ND Chromium VI (Cr6+) content (mg/kg with 50cm2)
Negative (< 0.02)
Negative (< 0.02)
Negative (< 0.02)
Negative (< 0.02)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation
was not found at the time of Test.
Tested Components (1) Coppery metal base material (Lead) (2) Silvery plating layer (Lead) (3) Gunmetal metal base material (Cap) (4) Silvery plating layer (Cap)
Responsibility of Chemist :Irene Chiou / Kevin Liu
Date Sample Received : Dec 06, 2012 Test Period : Dec 13, 2012 to Dec 19, 2012
(Ⅲ) Test Method: Test Item Test Method Reporting Limit
Cadmium (Cd) content
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Lead (Pb) content
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Mercury (Hg) content
With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Chromium VI (Cr6+) content
With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis Spectrophotometer.
0.02 mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
Material Acid Added For Digestion Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.
Applicant: Littelfuse Philippines Inc. Date : Nov 19, 2012 LIMA Technology Center, Lipa City,
Malvar, Batangas
Sample Description:
One (1) group of submitted samples said to be : Part Description : Yarn Part Number : 648106-001 Date Sample Received : Nov 12, 2012 Date Test Started : Nov 13, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Lead (Pb) content
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Mercury (Hg) content
With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Chromium VI (Cr6+) content
With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer.
1 ppm
Polybrominated Biphenyls (PBBs)
With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary.
5 ppm
Polybrominated Diphenyl Ethers (PBDEs)
With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary.
5 ppm
Halogen Content With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by Ion Chromatograph.
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
(Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.
Add absorbent in a combustion flask & place weighed sample in equipment
Applicant: Littelfuse Philippines Inc. Date : Nov 19, 2012 LIMA Technology Center, Lipa City,
Malvar, Batangas
Sample Description:
One (1) group of submitted samples said to be : Part Description : Yarn Part Number : 648112-001 Date Sample Received : Nov 12, 2012 Date Test Started : Nov 13, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Lead (Pb) content
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Mercury (Hg) content
With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Chromium VI (Cr6+) content
With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer.
1 ppm
Polybrominated Biphenyls (PBBs)
With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary.
5 ppm
Polybrominated Diphenyl Ethers (PBDEs)
With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary.
5 ppm
Halogen Content With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by Ion Chromatograph.
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
(Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.
Add absorbent in a combustion flask & place weighed sample in equipment
(Ⅲ) Test Method: Test Item Test Method Reporting Limit
Cadmium (Cd) content
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Lead (Pb) content
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Mercury (Hg) content
With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Chromium VI (Cr6+) content
With reference to IEC 62321 edition1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer.
1 ppm
Polybrominated Biphenyls (PBBs)
With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary.
5 ppm
Polybrominated DiphenylEthers (PBDEs)
With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary.
Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.
Sampling/grinding or cutting
Weigh sample and add organic solvent
By soxhlet extraction
Concentrate the extract and make up with organic solvent