Owners Manual I CRRFTSMRN°I Permanently Lubricated Compact AIR COMPRESSOR Model No. 919.152350 CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Safety Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Repair Parts Espahol Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman A08593 Rev. 0 11/4/04
28

I CRRFTSMRN°IOwners Manual I CRRFTSMRN I Permanently Lubricated Compact AIR COMPRESSOR Model No. 919.152350 CAUTION: Read the Safety Guidelines and All Instructions Carefully Before

Oct 23, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Owners Manual

    I CRRFTSMRN°IPermanently LubricatedCompact

    AIR COMPRESSORModel No. 919.152350

    CAUTION: Read the Safety Guidelinesand All Instructions Carefully Before

    Operating.

    • Safety Guidelines

    • Assembly

    • Operation

    • Maintenance

    • Service and Adjustments

    • Troubleshooting

    • Repair Parts

    • Espahol

    Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.Visit our Craftsman website: www.sears.com/craftsman

    A08593 Rev. 0 11/4/04

  • SPECIFICATION CHART .................... 2

    WARRANTY .............................. 2

    SAFETY GUIDELINES .................... 3-6

    GLOSSARY ............................... 7

    ACCESSORIES ........................... 7

    ASSEMBLY ............................... 7

    Contents of Carton ...................... 7

    To Remove Air compressor From Carton ..... 7

    INSTALLATION ............................ 8

    Location of Air Compressor ............... 8

    Grounding Instructions ................... 8

    Extension Cords ........................ 8

    Voltage and Circuit Protection ............. 8

    OPERATING PROCEDURES .............. 9-10

    Know Your Air Compressor ............... 9

    Description of Operation .................. 9

    How to Use Your Unit ................... 10

    How to Stop .......................... 10

    To Use Quick Connect Sockets and Plugs . .10

    To Use Female Tire Chuck ............... 10

    To Use Blow Gun ...................... 10

    Before Starting ........................ 10

    How to Start .......................... 10

    SERVICE AND ADJUSTMENTS ............. 11

    Air Hose Replacement .................. 11

    STORAGE ............................... 11

    TROUBLESHOOTING GUIDE ............... 12

    REPAIR PARTS ........................... 13

    ESPAI_IOL ............................... 15

    HOW TO ORDER REPAIR PARTS ..... back cover

    SPECI FICATION CHARTModel No. 919-152350

    Running Horsepower 1Displacement CFM 4.8Bore 1-7/8"

    Stroke 1-1/4"

    Voltage-Single Phase 120Minimum Branch Circuit Requirement 10 amps

    Fuse Type Time DelaySCFM @40 psig 3.7SCFM @90 psig 2.6

    FULL ONE YEAR WARRANTYAIR COMPRESSOR

    If this air compressor fails due to a defect in material or workmanship within one year from the date ofpurchase, RETURN IT TO THE NEAREST SEARS REPAIR CENTER THROUGHOUT THE UNITED STATESAND SEARS WILL REPAIR IT, FREE OF CHARGE. If purchased from Orchard Supply Hardware, return tothe nearest Orchard Store and Orchard will repair it, free of charge.

    If this air compressor is used for commercial or rental purposes, the warranty will apply for ninety daysfrom the date of purchase.

    This warranty gives you specific legal rights and you may have other rights which vary from state to state.

    Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, II 60179

    A08593 2- ENG

  • SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbolsbelow. Please read the manual and pay attention to these sections.

    Indicates an imminently hazardoussituation which, if not avoided, will

    result in death or serious injury.

    Indicates a potentially hazardous sit-uation which, if not avoided, could

    result in death or serious injury.

    Indicates a potentially hazardoussituation which, if not avoided, may

    result in minor or moderate injury.

    Used without the safety alert sym-bol indicates a potentially haz-

    ardous situation which, if not avoided, may result inproperty damaqe.

    SAVE THESE INSTRUCTIONS

    IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURYAND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUC-TIONS BEFORE USING THIS EQUIPMENT.

    RISK OF EXPLOSION OR FIRE

    WHAT CAN HAPPEN

    IT IS NORMAL FOR ELECTRICAL CONTACTS WITHINTHE MOTOR AND PRESSURE SWITCH TO SPARK.

    IF ELECTRICAL SPARKS FROM COMPRESSOR COME

    INTO CONTACT WITH FLAMMABLE VAPORS, THEYMAY IGNITE, CAUSING FIRE OR EXPLOSION.

    RESTRICTING ANY OF THE COMPRESSOR VENTILA-TION OPENINGS WILL CAUSE SERIOUS OVERHEATINGAND COULD CAUSE FIRE.

    UNATTENDED OPERATION OF THIS PRODUCT COULDRESULT IN PERSONAL INJURY OR PROPERTY DAM-AGE.

    HOW TO PREVENT IT

    ALWAYS OPERATE THE COMPRESSOR IN A WELL VEN-

    TILATED AREA FREE OF COMBUSTIBLE MATERIALS,GASOLINE OR SOLVENT VAPORS.

    IF SPRAYING FLAMMABLE MATERIALS, LOCATE COM-PRESSOR AT LEAST 20 FEET AWAY FROM SPRAYAREA. AN ADDITIONAL LENGTH OF HOSE MAY BEREQUIRED.

    STORE FLAMMABLE MATERIALS IN A SECURE LOCA-TION AWAY FROM COMPRESSOR.

    NEVER PLACE OBJECTS AGAINST OR ON TOP OFCOMPRESSOR. OPERATE COMPRESSOR IN AN OPENAREA AT LEAST 12 INCHES AWAY FROM ANY WALLOR OBSTRUCTION THAT WOULD RESTRICT THE FLOWOF FRESH AIR TO THE VENTILATION OPENINGS.

    OPERATE COMPRESSOR IN A CLEAN, DRY, WELL VENTI-LATED AREA. DO NOT OPERATE UNIT INDOORS OR INANY CONFINED AREA.

    ALWAYS REMAIN IN ATTENDANCE WITH THE PROD-UCT WHEN IT IS OPERATING.

    3- ENG A08593

  • RISK OF BURSTING

    AIR TANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, ANDRESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUSINJ URY.

    WHAT CAN HAPPEN HOW TO PREVENT IT

    1. FAILURE TO PROPERLY DRAIN CONDENSEDWATER FROM THE TANK, CAUSING RUST ANDTHINNING OF THE STEEL TANK.

    2. MODIFICATIONS OR ATTEMPTED REPAIRS TO THETANK.

    3. UNAUTHORIZED MODIFICATIONS TO THEUNLOADER VALVE, SAFETY VALVE, OR ANYOTHER COMPONENTS WHICH CONTROL TANKPRESSURE.

    4,

    DRAIN TANK DALLY OR AFTER EACH USE. IF TANK

    DEVELOPS A LEAK, REPLACE IT IMMEDIATELY WITH ANEW TANK OR REPLACE THE ENTIRE COMPRESSOR.

    NEVER DRILL INTO, WELD, OR MAKE ANY MODIFICA-TIONS TO THE TANK OR ITS ATTACHMENTS.

    THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPER-ATING PRESSURES, NEVER MAKE ADJUSTMENTS ORPARTS SUBSTITUTIONS TO ALTER THE FACTORY SETOPERATING PRESSURES.

    EXCESSIVE VIBRATION CAN WEAKEN THE AIRTANK AND CAUSE RUPTURE OR EXPLOSION.

    ATTACHMENTS & ACCESSORIES:

    EXCEEDING THE PRESSURE RATING OF AIR TOOLS,

    FOR ESSENTIAL CONTROL OF AIR PRESSURE, YOUMUST INSTALL A PRESSURE REGULATOR AND PRES-

    SPRAY GUNS, AIR OPERATED ACCESSORIES, TIRES ANDOTHER INFLATABLES CAN CAUSE THEM TO EXPLODEOR FLY APART, AND COULD RESULT IN SERIOUS INJURY.

    SURE GAUGE TO THE AIR OUTLET OF YOUR COM-PRESSOR. FOLLOW THE EQUIPMENT MANUFACTURERSRECOMMENDATION AND NEVER EXCEED THE MAXIMUMALLOWABLE PRESSURE RATING OF ATTACHMENTS.NEVER USE COMPRESSOR TO INFLATE SMALL LOW-

    PRESSURE OBJECTS SUCH AS CHILDREN'S TOYS,FOOTBALLS, BASKETBALLS, ETC.

    RISK FROM FLYING OBJECTS

    WHAT CAN HAPPEN

    THE COMPRESSED AIR STREAM CAN CAUSE SOFT TIS-SUE DAMAGE TO EXPOSED SKIN AND CAN PROPEL

    DIRT, CHIPS, LOOSE PARTICLES AND SMALL OBJECTSAT HIGH SPEED, RESULTING IN PROPERTY DAMAGE ORPERSONAL INJURY.

    HOW TO PREVENT IT

    ALWAYS WEAR ANSI Z87.1 APPROVED SAFETY GLASS-ES WITH SIDE SHIELDS WHEN USING THE COMPRES-SOR.

    NEVER POINT ANY NOZZLE OR SPRAYER TOWARDANY PART OF THE BODY OR AT OTHER PEOPLE ORANIMALS.

    ALWAYS TURN THE COMPRESSOR OFF AND BLEEDPRESSURE FROM THE AIR HOSE AND TANK BEFOREATTEMPTING MAINTENANCE, ATTACHING TOOLS ORACCESSORIES.

    A08593 4-ENG

  • RISK OF ELECTRICAL SHOCK

    WHAT CAN HAPPEN

    YOUR AIR COMPRESSOR IS POWERED BY ELECTRICI-TY. LIKE ANY OTHER ELECTRICALLY POWERED DEVICE,IF IT IS NOT USED PROPERLY IT MAY CAUSE ELECTRICSHOCK.

    REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNELCAN RESULT IN SERIOUS INJURY OR DEATH BY ELEC-TROCUTION.

    ELECTRICAL GROUNDING: FAILURE TO PROVIDE ADE-QUATE GROUNDING TO THIS PRODUCT COULDRESULT IN SERIOUS INJURY OR DEATH FROM ELEC-TROCUTION. SEE GROUNDING INSTRUCTIONS,

    HOW TO PREVENT IT

    NEVER OPERATE THE COMPRESSOR OUTDOORS WHENIT IS RAINING OR IN WET CONDITIONS.

    NEVER OPERATE COMPRESSOR WITH PROTECTIV-COVERS REMOVED OR DAMAGED,

    ANY ELECTRICAL WIRING OR REPAIRS REQUIRED ONTHIS PRODUCT SHOULD BE PERFORMED BY AUTHO-RIZED SERVICE CENTER PERSONNEL IN ACCORDANCEWITH NATIONAL AND LOCAL ELECTRICAL CODES.

    MAKE CERTAIN THAT THE ELECTRICAL CIRCUIT TOWHICH THE COMPRESSOR IS CONNECTED PROVIDES

    PROPER ELECTRICAL GROUNDING, CORRECT VOLT-AGE AND ADEQUATE FUSE PROTECTION.

    RISK TO BREATHING

    WHAT CAN HAPPEN HOW TO PREVENT IT

    THE COMPRESSED AIR DIRECTLY FROM YOUR COM-PRESSOR IS NOT SAFE FOR BREATHING. THE AIR

    STREAM MAY CONTAIN CARBON MONOXIDE, TOXICVAPORS, OR SOLID PARTICLES FROM THE TANK.BREATHING THESE CONTAMINANTS CAN CAUSESERIOUS INJURY OR DEATH.

    SPRAYED MATERIALS SUCH AS PAINT, PAINT SOL-VENTS, PAINT REMOVER, INSECTICIDES, WEEDKILLERS, CONTAIN HARMFUL VAPORS AND POISONS.

    AIR OBTAINED DIRECTLY FROM THE COMPRESSORSHOULD NEVER BE USED TO SUPPLY AIR FOR HUMANCONSUMPTION. IN ORDER TO USE AIR PRODUCED BYTHIS COMPRESSOR FOR BREATHING, SUITABLE FIL-TERS AND IN-LINE SAFETY EQUIPMENT MUST BEPROPERLY INSTALLED, IN-LINE FILTERS AND SAFETYEQUIPMENT USED IN CONJUNCTION WITH THE COM-PRESSOR MUST BE CAPABLE OF TREATING AIR TO ALLAPPLICABLE LOCAL AND FEDERAL CODES PRIOR TOHUMAN CONSUMPTION.

    WORK IN AN AREA WITH GOOD CROSS-VENTILATION.READ AND FOLLOW THE SAFETY INSTRUCTIONS PRO-VIDED ON THE LABEL OR SAFETY DATA SHEETS FORTHE MATERIAL YOU ARE SPRAYING. USE ANIOSH/MSHA APPROVED RESPIRATOR DESIGNED FORUSE WITH YOUR SPECIFIC APPLICATION,

    5- ENG A08593

  • RISK OF BURNS

    WHAT CAN HAPPEN

    TOUCHING EXPOSED METAL SUCH AS THE COMPRES-

    SOR HEAD OR OUTLET TUBES, CAN RESULT INSERIOUS BURNS.

    HOW TO PREVENT IT

    NEVER TOUCH ANY EXPOSED METAL PARTS ONCOMPRESSOR DURING OR IMMEDIATELY AFTER OPER-ATION. COMPRESSOR WILL REMAIN HOT FOR SEVERALMINUTES AFTER OPERATION.

    DO NOT REACH AROUND PROTECTIVE SHROUDS ORATTEMPT MAINTENANCE UNTIL UNIT HAS BEENALLOWED TO COOL.

    RISK FROM MOVING PARTS

    WHAT CAN HAPPEN HOW TO PREVENT IT

    MOVING PARTS SUCH AS THE PULLEY, FLYWHEEL ANDBELT CAN CAUSE SERIOUS INJURY IF THEY COMEINTO CONTACT WITH YOU OR YOUR CLOTHING,

    ATTEMPTING TO OPERATE COMPRESSOR WITH DAM-AGED OR MISSING PARTS OR ATTEMPTING TO REPAIRCOMPRESSOR WITH PROTECTIVE SHROUDS REMOVEDCAN EXPOSE YOU TO MOVING PARTS AND CANRESULT IN SERIOUS INJURY.

    NEVER OPERATE THE COMPRESSOR WITH GUARDSOR COVERS WHICH ARE DAMAGED OR REMOVED.

    ANY REPAIRS REQUIRED ON THIS PRODUCT SHOULDBE PERFORMED BY AUTHORIZED SERVICE CENTERPERSONNEL.

    RISK OF FALLING

    WHAT CAN HAPPEN HOW TO PREVENT IT

    A PORTABLE COMPRESSOR CAN FALL FROM A TABLE,WORKBENCH OR ROOF CAUSING DAMAGE TO THECOMPRESSOR AND COULD RESULT IN SERIOUSINJURY OR DEATH TO THE OPERATOR.

    ALWAYS OPERATE COMPRESSOR IN A STABLESECURE POSITION TO PREVENT ACCIDENTAL MOVE-MENT OF THE UNIT. NEVER OPERATE COMPRESSORON A ROOF OR OTHER ELEVATED POSITION. USEADDITIONAL AIR HOSE TO REACH HIGH LOCATIONS.

    RISK OF PROPERTY DAMAGE WHEN TRANSPORTINGCOMPRESSOR

    (Fire, Inhalation, Damage to Vehicle Surfaces)

    For units requiring oil in pump or gasoline engines

    WHAT CAN HAPPEN HOW TO PREVENT IT

    OIL CAN LEAK OR SPILL AND COULD RESULT IN FIRE

    OR BREATHING HAZARD, SERIOUS INJURY OR DEATHCAN RESULT. OIL LEAKS WILL DAMAGE CARPET, PAINTOR OTHER SURFACES IN VEHICLES OR TRAILERS,

    A08593

    ALWAYS PLACE COMPRESSOR ON A PROTECTIVE MATWHEN TRANSPORTING TO PROTECT AGAINST DAMAGETO VEHICLE FROM LEAKS, REMOVE COMPRESSORFROM VEHICLE IMMEDIATELY UPON ARRIVAL AT YOURDESTINATION.

    6 - ENG

  • Become familiar with these terms before operating theunit.

    CFM: Cubic feet per minute.

    SOFM: Standard cubic feet per minute; a unit ofmeasure of air delivery.

    PSlG: Pounds per square inch gauge; a unit of meas-ure of pressure.

    Code Certification: Products that bear one or moreof the following marks: UL, CUL, ETL, CETL, havebeen evaluated by ©SHA certified independent safetylaboratories and meet the applicable UnderwritersLaboratories Standards for Safety.

    Branch Circuit: Circuit carrying electricity from elec-trical panel to outlet

    This unit is capable of powering the following Accessories. The accessories are available through the currentPower and Hand Tool Catalog or full-line Sears stores.

    Accessories

    Quick Connect Sets (various sizes)

    Specialty Tools

    Air Brush

    Inflating/Blow Gun

    Grease Gun

    Caulk Gun

    Carpentry Tools

    Finishing Nailer / Stapler

    Contents of Carton

    1. Air Compressor with hose and pressureadjustment valve (qty 1)

    2. Quick Connect Coupling (qty 1)

    3. Quick Connect Studs (qty 2)

    4. Thread Sealant Tape (qty 1)

    5. Female Tire Chuck (qty 1)

    6. Blow Gun (qty 1)

    7. Safety Nozzle (qty 1)

    8. Blow Gun Adapter (qty 1)

    9. Inflating Needle (qty 1)

    10. Tapered Inflator (qty 1)

    To Remove Air Compressor From Carton

    1. Grasp handle and lift the air compressor out ofthe carton.

    2. Remove all packaging from air compressor anddiscard.

    9 8

    7- ENG A08593

  • HOW TO SET UP YOUR UNIT

    Location of the Air Compressor

    Locate the air compressor in a clean, dry and wellventilated area. The air compressor pump and shroudare designed to allow for proper cooling. The ventila-tion openings on the compressor are necessary tomaintain proper operating temperature. Do not placerags or other containers on or near these openings.

    GROUNDING INSTRUCTIONS

    RISK OF ELECTRICALSHOCK. In the event of a

    short circuit, grounding reduces the risk ofshock by providing an escape wire for theelectric current. This air compressor must beproperly grounded.

    The portable air compressor is equipped with a cordhaving a grounding wire with an appropriate ground-ing plug (see following illustrations). The plug must beused with an outlet that has been installed andgrounded in accordance with all local codes and ordi-nances.

    1. The cord set and plug with this unit contains agrounding pin. This plug MUST be used with agrounded outlet.

    IMPORTANT: The outlet being used must be installedand grounded in accordance with all local codes andordinances.

    2. Make sure the outlet being used has the sameconfiguration as the grounded plug. DO NOT USEAN ADAPTER. See figure.

    3.

    4.

    Grounding Pin

    @--_ Grounded

    / Outlets

    Inspect the plug and cord before each use. Donot use if there are signs of damage.

    If these grounding instructions are not completelyunderstood, or if in doubt as to whether the com-pressor is properly grounded, have the installationchecked by a qualified electrician.

    TRICAL SHOCK.

    IMPROPER GROUNDINGRESULT IN ELEC-

    Do not modify the plug provided. If it doesnot fit the available outlet, a correct outletshould be installed by a qualified electri-cian.

    Repairs to the cord set or plug MUST bemade by a qualified electrician.

    Extension Cords

    Use extra air hose instead of an extension cord to

    avoid voltage drop and power loss to the motor, andto prevent overheating.

    If an extension cord must be used, be sure it is:

    • a 3-wire extension cord that has a 3-blade

    grounding plug, and a 3-slot receptacle that willaccept the plug on the product

    • in good condition

    • no longer than 50 feet

    • 14 gauge (AWG) or larger. (Wire size increases asgauge number decreases. 12 AWG, 10 AWG, and8 AWG may also be used. DO NOT USE 16 OR18 AWG.)

    Voltage and Circuit Protection

    Refer to the Parts Manual for the voltage and mini-mum branch circuit requirements.

    Certain air compressors can be operated on a 15 ampcircuit if the following conditions are met.

    1. Voltage supply through branch circuit is 15 amps.

    2. Circuit is not used to supply any other electricalneeds (lights, appliances, etc.).

    3. Extension cords comply with specifications.

    4. Circuit is equipped with a 15 amp circuit breakeror 15 amp time delay fuse. NOTE: If compressoris connected to a circuit protected by fuses, useonly time delay fuses marked "D".

    If any of the above conditions cannot be met, or ifoperation of the compressor repeatedly causes inter-ruption of the power, it may be necessary to operate itfrom a 20 amp circuit. It is not necessary to changethe cord set.

    A08593 8-ENG

  • Know Your Air Compressor

    READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustra-tions with your unit to familiarize yourself with the location of various controls and adjustments. Save this manualfor future reference.

    On/Off Switch

    Pressure

    Adjustment

    Quick Connect

    Coupling Tapered Inflator

    Inflating Needle

    Connect

    Description of Operation

    Pressure Adjustable Valve: The pressure valve con-trols the amount of pressure going from the air com-pressor to the accessory. The pressure adjusting valvecan be used to set approximate pressure between 10and 125 PSI (125 PSI is the highest pressure thiscompressor will deliver).

    On/Off Switch (located on opposite side of aircompressor): Used to turn air compressor on and off.

    Quick Connect Coupling: Makes tool change overseasy.

    Quick Connect Studs: Install on tools and insert intothe quick connect coupling to make tool changeovers easier.

    Thread Sealant Tape: Use on threads to eliminate airleaks.

    Female Tire Chuck: Adapter for inflating tires.

    Blow Gun: Ideal for blowing, cleaning, and inflating.

    Safety Nozzle: Prevents pressure build-up.

    Blow Gun Adapter: Attached to blow gun or femalehose end to allow the tapered Inflator or inflating nee-dle to be used.

    Inflating needle: Used to inflate sport balls.

    Tapered Inflator: Used to inflate toy inflatables/airmattresses.

    9- ENG A08593

  • How to Use Your Unit

    How to Stop:

    1. Set the On/Off switch to"OFF".

    To Use Quick Connect

    Coupling and Studs

    1. Apply thread sealant tapeto threads of quick con-nect coupling and studs,

    2. Assemble the quick con-nect coupling to the hose,Attach the studs to theblow gun and female tire chuck. Tighten securely,This will make it easier to change over theseaccessories.

    3. Pull quick connect coupling back and insert stud.See figure above,

    4. Slide coupling forward to lock in place,

    To Use Female Tire Chuck

    1. Attach female tire chuck to hose.

    2. See the "How to Start" paragraph to start aircompressor.

    3. Place the female tire chuck onto the tire valvestem of the tire to be inflated.

    , Slowly increase the pressure setting of theadjustable pressure valve to the tire manufactur-er's recommended PSI. Note: To ensure correct

    tire pressure use a tire pressure gauge.

    To Use Blow Gun

    1, Attach the blow gun to hose.

    If an accessoryis not being

    used with the blow gun, thesafety nozzle MUST beassembled.

    Safety Nozzle

    2. Assemble the safety nozzle or blow gun adapterto blow gun. See next figure.

    NOTE: To use the inflating needle or tapered inflatorthe blow gun adapter has to be assembled to blowgun.

    I Lever BlowGunAdapter

    Inflating Needle

    Tapered Inflator

    Safety Nozzle

    3. Attach the inflating needle or tapered inflator tothe blow gun adapter on the blow gun.

    4. See the "How to Start" paragraph to start aircompressor.

    5. Depress lever on blow gun to release the air.

    Before Starting:

    1. Place On/Off switch to "OFF".

    2. Place theadjustable pres-sure valve to 10PSI.

    2. Attach hose andaccessories.

    Too much air pressurecauses a hazardous risk of

    bursting. Check the manufacturer's maximumpressure rating for air tools and accessories.Carefully follow the "How to Start" instruc-tions.

    How to Start:

    1. Place On/Off switch to "OFF".

    2.

    3.

    4.

    5,

    Plug the power cord into the grounded outlet.

    Place On/Off switch to "ON" to start compressor.

    Check the manufacturer's maximum pressure rat-ing for the air tool, accessory, or vehicle tire beingused. The air compressor outlet pressure mustnever exceed the maximum pressure rating.

    Slowly increase the pressure setting of theadjustable pressure valve. You should be able tohear and feel air pressure being relieved by theadjustable pressure valve. If pressure is not beingrelieved, turn the air compressor off immediately.The pressure valve must be replaced.

    Compressed air from theoutfit may contain water

    condensation. Do not spray unfiltered air atan item that could be damaged. Some airoperated tools or devices may require filteredair. Read the instructions for the air tool ordevice.

    A08593 10-ENG

  • Air Hose Replacement

    The air hose attached to your compressor has anintegral pressure adjusting valve at the working end ofthe hose. Should service or replacement be required,make sure that the pressure adjusting valve is presentin the air hose line.

    DO NOT replace the hosewith standard hose that is

    not equipped with the pressure adjustingvalve. The appropriate hose assembly foryour compressor is available at Sears.

    Do not allow hose tobecome kinked or

    pinched at any time. This is important toavoid damage to your compressor and tomaintain pressure adjusting valve control.

    1.

    2.

    Set the On/Off switch to "OFF" and unplug thecord.

    Relieve all pressure from the air compressor headand air hose by turning the adjustable pressurevalve to 10 PSI.

    3. Protect the electrical cord and air hose from dam-

    age by winding them loosely around the air com-pressor.

    4. Store the air compressor in a clean and dry loca-tion.

    11- ENG A08593

  • Voltage sources, moving parts, or compressed air sources are exposed when repairing thecompressor. Personal injury can occur. Unplug the compressor before attempting any repairs.

    PROBLEM

    Air Leaks

    Compressor is not deliveringenough air.

    Motor will not run.

    CAUSE

    Hose fitting loose.

    Prolonged excessive use of air.

    Hole in hose.

    Air leaks.

    CORRECTION

    Tighten fitting.

    Decrease the amount of air usage.Your compressor is not largeenough for the air requirement.

    Fuse blown, circuit breakertripped.

    Extension cord is wrong length orgauge.

    High discharge pressure. Cannotbe adjusted lower.

    Loose electrical connections.

    Faulty motor.

    Adjustable pressure valve notfunctioning.

    Replace the hose.

    Tighten fittings.

    1.

    2.

    3.

    4.

    5.

    Check fuse box for blown fuse

    and replace as necessary.Reset circuit breaker. Do notuse a fuse or circuit breaker

    with higher rating than thatspecified for your particularbranch circuit.

    Check for proper fuse. Youshould be using a "TimeDelay" fuse.

    Check for low voltage prob-lem.

    Check the extension cord.

    Disconnect the other electricalappliances from circuit oroperate the compressor on itsown branch circuit.

    Check the extension cord.

    Check wiring connection insideterminal box area.

    Contact a Trained ServiceTechnician.

    Risk of burst-ing. DO NOT

    operate the compressor if thisproblem exists. Adjustable pres-sure valve must be replaced.

    A08593 12 - ENG

  • 14

    19 Torque30-45 in.-Ibs.

    15

    /16

    21

    / 2322

    KEY

    NO1234567899-89-99-109-119-129-1312131415161718192O212223

    \18

    +

    X

    +

    ×

    ×

    3

    717

    PART NO. DESCRIPTIONSSF-995 Screw #10-24 x 718 (4)CAC-1196 Cylinder HeadCAC-1212 Tube SealCAC-1199 Head GasketZ-A08548 Valve Plate AssemblySSG-8169 "O" RingAC-0187-1 Outlet Tube

    GasketZ-A04615 Sub Pump Assembly

    Rod AssemblyPre-Formed Compression RingConnecting Rod Cap

    D21127 Screw #10-24SSF-3147 Screw 3/8-16 UNC

    Cylinder SleeveAC-0815 Timing BeltD25731 Pump Isolator (5)CAC-1319-1 Shroud (left)D21709 Label, Tool RatingCAC-1320 Shroud (right)CAC-1206-1 ClampCAC-4324 Pressure Valve Assembly and HoseSUDL-9-1 Screw, GroundSSS-16 SwitchSSF-3156 Shroud Screws (5)CAC-1211 Housing Isolator (3)D21708 Label, Performance

    NOT ILLUSTRATED/NO SE MUSTRANx KK-4929 Fastener Kit> KK-4964 Connecting Rod Kit

    D30139 Gasket & Seal Kit+ D30324 Ring Kit

    A08593 Owner's ManualLA-3146 Label, WarningD23786 Power CordD23787 Jumper Wire

    22

    DESCRIPCIONTornillo #10-24 x 7/8 (4)Cabezal del cilindroSello del tuboJunta - CabezalPlaca de la valvulaAnillo "O"Tubo de salidaJuntaConjunto de Sub-BombaEnsamblaje de la bielaRing Anillo de compresidn preformadoTapa de la barra de conexi6nTornillo #10-24Tornillo 3/8-16 UNCManga del CilindroCorrea de regulaci6nAislante de pompe (5)Cubierta, izquierdaR6tulo, grade de la herramientaLubierta, derechaAbrazaderaValvula de presidn y mangueraTornillos para TierraInterruptorTornillos para la cubierta (5)Aislante del casco (3)R6tulo, funcionamiento

    El juego de sujetadoresEl juego de la barra de conexi6nJuego de empaquetaduras y sellosConjunto de sujeci6n juego de anilloManual del propietarioR6tulo, advertenciaCable electricoAlambre de puente

    13-ENG A08593

  • HOJA DE ESPECIFICACIONES ............... 14

    GARANTIA ................................ 14

    NORMAS DE SEGURIDAD ................ 15-18

    GLOSARIO ................................ 19

    ACCESORIOS ............................. 19

    ENSAMBLADO ............................. 19

    Contenido de la caja ..................... 19

    C6mo extraer el compresor de aire de la caja..19

    INSTALACION ............................. 20

    Ubicaci6n del compresor de aire ............ 20

    Instrucciones para conectar a tierra ......... 20

    Extensiones el@ctricas .................... 20

    Protecci6n del voltaje y del circuito .......... 20

    PROCEDIMIENTOS OPERATIVOS .......... 21-22

    Conozca su compresor de aire ............. 21

    Descripci6n de operaciones ................ 21

    Come usar su unidad ..................... 22

    Come detenerla ......................... 22

    C6mo utilizar z6calos y enchufes de

    conexi6n r_.pida ......................... 22

    C6mo utilizar el pico hembra para el infladode los neum6.ticos ....................... 22C6mo utilizar la pistola sopladora ........... 22

    Antes de comenzar ...................... 22

    C6mo dar arranque ...................... 22

    SERVIClOS Y REGULAClONES ............... 23

    Reemplazo de la manguera de aire .......... 23

    ALMACENAJE ............................. 23

    GUlA DE DIAGNOSTICO DE PROBLEMAS ...... 24

    PIEZAS DE REPARACION ................... 13

    COMO SOUCITAR PIEZAS PAPA REPARACION

    ............................... contratapa

    HOJA DE ESPECIFICACIONESModelo 919-152350

    Potwncia de trabajo 0,1CFM de desplazamiento 4,8Di_.metro 1-7/8"

    Carrera 1-1/4"

    Voltaje - Monof_.sico 120

    Requerimientos minimo por circuito ramal 10 ATipo de fusible Acci6n retardadaSCFM a 40 PSIG 3,7

    SCFM a 90 PSIG 2,6

    GARANTIA COMPLETA POR UN AI_IOCOMPRESOR DE AIRE

    Si este compresor de aire fallara por defectos en materiales o mano de obra dentro del lapso de un aSoa partir de lafecha de su compra, DEVUC:LVALOAL CENTRO DE REPARACIONESSEARS MAS CERCANO DENTRODE LOSESTADOSUNIDOS, Y SEARS LO REPARARA,LIBRE DE CARGO. Si se hubiese comprado a Orchard SupplyHardware, devu@lvaloal comercio Orchard mas cercano y Orchard Io reparar_.,libre de cargo.

    Si este compresor de aire fuese utilizado para propositos comerciales o de alquiler, la garantia solo tendra validezpor noventa dias a partir de la compra.

    Esta garantia le otorga derechos legales especificos, aunque usted podr_,tener otros derechos que podrian variarentre estados.

    Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, II 60179

    A08593 14- SP

  • SEGURIDAD Y PREVENCION DE PROBLEMAS DEL EQUIPO: Para ayudar al reconocimiento de esta informaciOn, hemosutilizado los simbolos mostrados abajo. Sfrvase leer el manual y prestar atenciOn a dichas secciones.

    Indica una situaci6n de inminente riesgo, la cual,si no es evitada, causarA la muerte o lesiones

    serias.

    Indica una situaciOn potencialmenteriesgosa, que si no es evitada, podria

    resultar en la muerte o lesiones serias.

    _lndica una situaciOn potencialmentepeligrosa, la cual, si no es evitada, podria

    resultar en lesiones menores o moderadas.

    Usado sin el simbolo de seguridad dealerta indica una situaci6n potencial-

    mente riesgosa la que, si no es evitada, podria causar dafios enla propiedad.

    GUARDE ESTAS INSTRUCClONES

    La operacibn o el mantenimiento inadecuados de este producto podrian ocasionar serias lesiones ydafios a la propiedad. Lea y comprenda todas las advertencias e instrucciones de funcionamientoantes de utilizar este equipo.

    RIESGO DE EXPLOSION O INCENDIO

    &QUI_ PUEDE OCURRIR?

    PARA LOS CONTACTOS ELI_CTRICOS ES NORMAL LAEXISTENCIA DE CHISPAS ENTRE EL MOTOR Y ELINTERRUPTOR A PRESION.

    SI LAS CHISPAS EL¢CTRICAS PROVENIENTES DEL COMPRESORTOMARAN CONTACTO CON EMANACIONES DE MATERIALESINFLAMABLES, ELLOS PODRIAN ARDER ORIGINANDOINCENDIO O EXPLOSION.

    RESTRINGIR CUALQUIERA DE LAS ABERTURAS DEVENTILAClON CAUSARA UN SERIO RECALENTAMIENTOY PODRIA PRODUCIR UN INCENDIO.

    DEJAR DESATENDIDO ESTE PRODUCTO MIENTRAS ELMISMO EST,&. EN FUNCIONAMIENTO PUEDE RESULTAR ENLESlONES PERSONALES O DAI_IOS A LA PROPIEDAD.

    _,C6MO PREVENIRLO?

    OPERE SIEMPRE EL COMPRESOR EN UN SECTOR BIENVENTILADO Y LIBRE DE MATERIALES COMBUSTIBLES,GASOLINA O EMANAClONES DE SOLVENTE.

    EN UN AREA DE ROCIADO DE MATERIALES INFLAMABLES,

    UBIQUE AL COMPRESOR POR LO MENOS A 6,1M (20 PIES) DEDISTANCIA DEL h.REA DE ROCIADO. PODRiA REQUERIRSEUNA EXTENSION DE LA MANGUERA.

    ALMACENE LOS MATERIALES INFLAMABLES EN UNAUBICACION SEGURA, ALEJADOS DEL COMPRESOR.

    JAMAS COLOQUE OBJETOS APOYADOS O SOBRE EL COM-PRESOR. OPERE EL COMPRESOR EN UN SECTOR ABIERTO,

    POR LO MENOS A 30 CM (12 PULGADAS) ALEJADO DECUALQUIER PARED U OBSTRUCCION QUE RESTRINJA ELFLUJO DE AIRE FRESCO A LAS ABERTURAS DE VENTILACION.

    OPERE EL COMPRESOR EN UN SECTOR LIMPIO, SECO, Y BIENVENTILADO. NO OPERE LA UNIDAD EN ESPACIOS CERRADOSO CUALQUlER ,&,REA CONFINADA.

    MANTleNGASE SlEMPRE ALERTA CADA VEZ QUE ELPRODUCTO ESTE FUNCIONANDO.

    15- SP A08593

  • RIESGO DE EXPLOSION

    TANQUE DE AIRE: LAS SIGUIENTES CONDICIONES PUEDEN DETERMINAR EL DEBILITAMIENTODEL TANQUE, Y ORIGINAR UNA VIOLENTA EXPLOSION DEL MISMO, SIENDO CAUSA DE DAhlOS ALA PROPIEDAD 0 LESIONES SERIAS.

    2.

    3.

    _,QU¢: PUEDE OCURRIR? &C6MO PREVENIRLO?

    DRENAJE INADECUADO DEL AGUA CONDENSADA ENEL TANQUE, SIENDO LA CAUSA DEL OXIDO QUE REDUCEEL ESPESOR DEL TANQUE DE ACERO.

    MODIFICACIONES O INTENTO DE REPARACIONES ALTANQUE.

    MODIFICACIONES NO AUTORIZADAS A LA VALVULA DEDESCARGA, VALVULA DE SEGURIDAD 0 CUALQUIEROTRO COMPONENTE QUE CONTROLE LA PRESION DELTANQUE.

    LA VIBRACION EXCESIVA PUEDE DEBILITAR EL TANQUEDE AIRE Y CAUSAR SU RUPTURA O EXPLOSION.

    AGREGADOS Y ACCESORIOS

    EL EXCESO A LOS VALORES DE PRESION ESTABLECIDOSPARA I.AS HERRAMIENTAS NEUMATICAS, PISTOLAS ROGIADO-RAS, ACCESORIOS ACTIVADOS POR AIRE, CUBIERTAS Y OTROSOBJETOS INFLABLES, PUEDE CAUSAR SU EXPLOSION O SERARROJADOS, PUDIENDO OCASIONAR SERIAS LESIONES.

    DRENE EL TANQUE DIARIAMENTE O DESPUI_S DE CADA USO.Sl EL TANQUE GENERA UNA PCRDIDA, REEMPLikCELOINMEDIATAMENTE CON UN NUEVO TANQUE O REEMPLACE ELCOMPRESOR COMPLETO.

    JAMAS PERFORE, SUELDE, O EFECTUE MODIFICACION ALGUNAAL TANOUE O SUS ACCESORIOS.

    EL TANQUE ESTik DISENADO PARA RESISTIR PRESIONESOPERATIVAS ESPECiFICAS. JAMAS EFECTUE AJUSTES OSUSTITUYA PARTES QUE ALTEREN LAS REGULACIONES DEPRESION ORIGINALES DE FABRICA.

    PARA UN CONTROL ESENCIAL DE LA PRESION, DEBE USTEDINSTALAR UN REGULADOR Y UN MEDIDOR DE PRESlON A LA

    SALIDA DEL AIRE DE SU COMPRESOR. (Sl NO ESTUNIEREQUIPADO) SIGA LAS RECOMENDACIONES DE LOSFABRICANTES DE SU EQUIPO Y JAMAS EXCEDA LOS VALORESM/kXIMOS DE PRESION PERMITIDOS PARA LOS ACCESORIOS.JAMAS USE EL COMPRESOR PARA INFLAR OBJETOS QUEREOUIEREN POOA O BAJA PRESlON, TALES COMOJUGUETES PARA LOS NII_IOS, PELOTAS DE FUTBOL, PELOTASDE BASQUET, ETC.

    RIESGO DE OBJETOS ARROJADOS POR EL AIRE.

    _,QU¢: PUEDE OCURRIR?

    EL CHORRO DE AIRE COMPRIMIDO PUEDE CAUSAR DAI_IOS

    SOBRE LOS TEJIDOS BLANDOS DE LA PIEL EXPUESTA, YPUEDE PROPULSAR SUCIEDAD, ASTILLAS, PARTICULASSUELTAS Y PEQUE_IOSOBJETOS A ALTA VELOClDAD, OCASIONANDODANOS A LA PROPIEDAD O LESIONES PERSONALES.

    &C6MO PREVENIRLO?

    AL UTILIZAR EL COMPRESOR, USE SIEMPRE ANTEOJOS DESEGURIDAD ANSI Z87.1 APROBADOS, CON PROTEOCIONLATERAL.

    JAMAS APUNTE NINGUNA BOQUlLLA O PULVERIZADOR

    HAOIA PARTES DEL CUERPO, A OTRAS PERSONAS OANIMALES.

    APAGUE SIEMPRE EL COMPRESOR Y PURGUE LA PRESION

    DE LA MANGUERA DEL AIRE Y DEL TANQUE, ANTES DE INTENTAREL MANTENIMIENTO, EL ACOPLE DE HERRAMIENTAS OACCESORIOS.

    A08593 16- SP

  • RIESGO DE DESCARGA ELI=CTRICA

    _QUEPUEDE OCURRIR?

    SU COMPRESOR DE AIRE ESTA ACCIONADO POR ELECTRICIDAD.COMO CUALQUIER OTRO DISPOSITIVO ELECTRICO IMPULSADOEL¢CTRICAMENTE, Sl NO SE LO UTILIZA ADECUADAMENTE,PODRiA CAUSARLE UNA DESCARGA ELleCTRICA.

    LAS REPARAClONES INTENTADAS POR PERSONAL NOCALIFICADO PODRIAN OCASlONAR SERIAS LESlONES O LAMUERTE POR ELECTROCUCION.

    CONEXION A TIERRA: DEJAR DE PROVEER UNA ADECUADACONEXlON A TIERRA A ESTE PRODUCTO PODRiA OCASlONARLESlONES SERIAS O LA MUERTE POR ELECTROCUCION. VERINSTRUCCIONES PARA LA PUESTA A TIERRA.

    _C6MO PREVENIRLO?

    JAMAS OPERE EL COMPRESOR A LA INTEMPERIE CUANDOESTA LLOVlENDO O EN CONDICIONES DE HUMEDAD.

    NUNCA OPERE EL COMPRESOR SIN SUS DEFENSAS O SUSCUBIERTAS REMOVIDAS O DAI_IADAS.

    CUALQUIER CONEXlON ELleCTRICA O REPARACION

    REQUERIDA POR ESTE PRODUCTO DEBE SER EFECTUADAPOR PERSONAL AUTORIZADO DE LOS SERVICENTROS DEACUERDO A LOS CODIGOS ELECTRICOS NACIONALES YLOCALES.

    ASEGURESE QUE EL CIRCUITO ELleCTRICO AL CUAL ESTACONECTADO EL COMPRESOR, SUMINISTRA APROPIADACONEXlON A TIERRA, TENSION CORRECTA Y UNA ADECUADAPROTECCION DE FUSlBLES.

    RIESGO DE INHALACION

    &QU¢: PUEDE OCURRIR? _,COMO PREVENIRLO?

    EL AIRE COMPRIMIDO PROVENIENTE DEL COMPRESOR NOES SANO PARA RESPIRAR. EL CHORRO DE AIRE PUEDE

    CONTENER MONOXlDO DE CARBONO, VAPORES T(_XlCOS OPART[CULAS SOLIDAS PROVENIENTES DEL TANQUE. LAINHALACION DE DICHOS CONTAMINANTES PUEDE LLEGAR ACAUSAR SERIAS LESlONES O LA MUERTE.

    EL ROCIADO DE MATERIALES TALES COMO PINTURA,SOLVENTES, REMOVEDORES DE PINTURA, INSECTICIDAS, MATAHIERBAS, CONTIENEN EMANACIONES DAi_INAS Y VENENOSAS.

    EL AIRE OBTENIDO DIRECTAMENTE DEL COMPRESOR JAMASDEBERA SER UTILIZADO PARA PROVEER AIRE PARA CONSUMOHUMANO. PARA PODER UTILIZAR EL AIRE PRODUCIDO PORESTE COMPRESOR Y HACERLO RESPIRABLE, DEBERANINSTALARSE UN FILTRO ADECUADO Y UN EQUlPO DESEGURIDAD INTERCALADO. LOS FILTROS INTERCALADOSTANTO COMO EL EQUIPO DE SEGURIDAD UTILIZADO ENCON JUNTO CON EL COMPRESOR, DEBERAN SER CAPACESDE PROCESAR EL TRATAMIENTO DEL AIRE DE ACUERDO ATODOS LOS CODIGOS LOCALES Y FEDERALES, PREVIO ALCONSUMO HUMANO.

    TRABAJE EN UN .&.REA CON BUENA VENTILACION CRUZADA.LEA Y SIGA LAS INSTRUCCIONES DE SEGURIDAD PROVISTASEN EL ROTULO O EN LOS DATOS DE LAS HOJAS DE SEGURIDADDEL MATERIAL QUE EST.&.PULVERIZANDO. USE EL RESPIRADORAPROBADO NIOSH/MSHA DESIGNADO PARA UTILIZARSE CONSU APLICACION ESPEC[FICA.

    17 - SP A08593

  • RIESGO DE QUEMADURAS

    _,QU¢: PUEDE OCURRIR?

    TOCAR EL METAL EXPUESTO TAL COM© EL CABEZAL DEL

    COMPRESOR O LOS TUBOS DE SALIDA DEL ESCAPE, PUEDEOOASlONARLE SERIAS QUEMADURAS.

    &COMO PREVENIRLO?

    JAMAS TOQUE PARTES DE METAL EXPUESTAS EN ELCOMPRESOR DURANTE O INMEDIATAMENTE DESPUt_S DE LAOPERACION. EL OOMPRESOR PERMANECERA CALIENTEPOR VARIOS MINUTOS LUEGO DE LA OPERACION.

    NO LO CUBRA CON FUNDAS PROTECTORAS O INTENTE ELMANTENIMIENTO HASTA QUE LA UNIDAD HAYA ALCANZADOSU ENFRIAMIENTO.

    RIESGO DE PARTES MOVILES

    _,QU¢: PUEDE OCURRIR? &COMO PREVENIRLO?

    PARTES MOVIBLES TALES COMO LA POLEA, EL VOLANTE Y LACORREA PODRIAN SER LA CAUSA DE SERIAS LESlONES Sl

    ELLAS ENTRARAN EN CONTACTO CON USTED O SUS ROPAS.

    INTENTAR OPERAR EL COMPRESOR CON SUS PARTESDAI_IADAS O FALTANTES, O LA REPARACION DEL COMPRESORCON SUS PROTECCIONES REMOVIDAS, PUEDE EXPONERLOA USTED A PARTES MOVIBLES, QUE PODRIAN RESULTAR ENLESIONES SERIAS,

    NUNCA OPERE EL COMPRESOR SIN SUS DEFENSAS O SUSCUBIERTAS REMOVIDAS O DANADAS.

    CUALQUIER REPARACION REQUERIDA POR ESTE PRODUCTODEBE SER EFEOTUADA POR PERSONAL AUTORIZADO DELOS SERVICENTROS.

    RIESGO DE CAIDA

    _,QU¢: PUEDE OCURRIR? &COMO PREVENIRLO?

    UN COMPRESOR PORTATIL PUEDE CAERSE DE LA MESA, ELBANCO DE TRABAJO O DEL TECHO DAI_IANDO AL OOMPRESOR Y

    PUDIENDO RESULTAR EN SERIAS LESlONES O LA MUERTEDEL OPERADOR.

    OPERE SlEMPRE EL COMPRESOR EN UNA POSlClONESTABLE Y SEGURA A FIN DE PREVENIR EL MOVIMIENTOACCIDENTAL DE LA UNIDAD. JAMAS OPERE EL COMPRESORSOBRE UN TECHO U OTRA POSlCION ELEVADA. UTILICEMANGUERAS ADIClONALES DE AIRE PARA ALCANZARPOSlOIONES ALTAS.

    RIESGO DE DAI_IOS A LA PROPIEDAD AL TRANSPORTAR

    EL COMPRESOR

    (Fuego, inhalacion, daho a la superficie de vehiculos}

    Para unidades que requieran aceite en la bomba o motores a gasolina.

    _,QU¢: PUEDE OCURRIR? &COMO PREVENIRLO?

    DEPOSITE EL COMPRESOR SOBRE UNA ALFOMBRILLA PRO-TECTORA CUANDO LO TRANSPORTE. A FIN DE PROTEGER AL

    VEHfCULO DE Pt_RDIDAS POR GOTEO, RETIRE EL COMPRESORDEL VEHICULO INMEDIATAMENTE DESPUES DE SU ARRIBO ALDESTINO.

    A08593 18- SP

  • Familiaricese con los siguientes t6rminos, antes de operar launidad:

    Cfm: (Cubic feet per minute) Pies ct_bicos por minuto.

    SCFM: (Stardardcubic feetper minute)Pies ct_bicosestandarpor minuto; unaunidadde medida quepermitemedir la canti-dad de entregade aire.

    PSlG: (Poundpersquareinch)Ubrasper pulgadacuadrada.

    C6digo de certificaci6n: Los productos que usan una omas de las siguientes marcas: UL, CUL, ETL, CETL, hansido evaluados pot OSHA, laboratorios independientes cer-tificados en seguridad, y reOnenlos est_.ndaressuscriptospor los laboratories dedicados a la certificaci6n de laseguridad.

    Ramal: Circuito el6ctrico que transporta electricidad desdeel panel de control hasta el tomacorriente.

    Esta unidad es suficiente para abastecer de energia el6ctrica a los siguientes accesorios. Estos se encuentran disponibles atraves del catalogo para herramientas el_ctricas y manuales, en cualquiera de los comercios que mantiene la linea completade SEARS.

    Accesorios Herramientas para carpinteria

    Juegos de conexi6n r_.pida (varias medidas) M_.quina clavadora / abrochadora

    Herramientas pot especialidades

    Cepillo neum_tico

    Pistola infladora / sopladora

    Pistola engrasadora

    Pistola para aplicaci6n de sellador

    Contenido de la caja de embalaje

    1. Compresor de aire con manguera y v_.lvulareguladorade presi6n (cant. 1)

    2. Receptaculo para conexi6n ra.pida(Cant. 1)

    3. Enchufe para conexi6n r_pida (Cant. 2)

    4. Cinta selladora para rosca (Cant. 1)

    5. Pico hembrapara Ilenadode airea los neumaticos(Cant.1)

    6. Pistola sopladora (Cant. 1)

    7. Boquilla de seguridad (Cant 1)

    8. Adaptador para pistola sopladora (Cant. 1)

    9. Aguja parainflado (Cant.l)

    10. Inflador roscado (Cant. 1)

    Para extraer el compresor de aire de su caja

    1. Suj6telo de la manija y lev_.ntelo fuera de su caja.

    2. Extraiga y descarte todo el embalaje del compre-sor de aire.

    10

    19- SP A08593

  • COMO PREPARAR LA UNIDAD

    Ubicacion del compresor de aire

    Ubique alcompresorde aireen unazona limpia,secay bienventilada.La bomba del compresorde aire y su carcasahansido dise_adasparapermitirun enfriamientoadecuado.Lasaberturasdeventilaci6ndel compresorresultan- entonces-necesariasparaelmantenimientode unaadecuadatemperaturadefuncionamiento.No coloque g6neroso contenedores,enci-ma, nien las proximidadesde dichasaberturas.

    INSTRUCCIONES PAPACONECTAR A TIERRA

    RIESGO DEDESCARGA

    ELECTRICA Ante la eventualidad de un cortocir-cuito, la conexi6n a tierra reduce el riesgo de elec-trocuci6n proveyendo un conductor de escapepara la corriente el_ctrica. Este compresor de airedebe estar adecuadamente conectado a tierra.

    El compresor portatil de aire esta equipado con uncable que tiene un conductor destinado a tierra, conuna espiga apropiada para su conexi6n (ver las sigu-ientes ilustraciones). El enchufe debe ser utilizado conun toma corriente que haya sido instalado y conectadoa tierra de acuerdo a todos los c6digos y ordenanzaslocales.

    1. El cable que acompa_a a esta unidad tiene unaespiga para conexi6n a tierra. Esta DEBE serutilizada con un tomacorriente conectado a tierra.

    IMPORTANTE: El tomacorriente que ser_.utilizado deberahaber sido conectado a tierra conforme a todos los c6digoslocales y ordenanzas.

    2. AsegQresede queel tomacorrientequeserautilizadotengalamismaconfiguraci6nqueelenchufede conexi6na tierra.NO UTILICE UN ADAPTADOR.Ver figura.

    _hufe

    /Espiga de conexi6n a tierra

    Tomacorrientes"conectados a• tierra

    3.

    4.

    Inspeccioneelenchufey su cord6n antesde cada uso.No usesi existieransignos deda_os.

    Si las instruccionesde conexi6na tierra nofuerancomple-tamentecomprendidas,o si se estuvieraantela duda acer-ca de que el compresorestuvieseadecuadamente conec-tado a tierra, haga verificar la instalaci6n por un elec-tricista competente.

    LA CONEXIONINADECUADA

    A TIERRA PUEDE DETERMINAR UNADESCARGA ELI_CTRICA.No modifique el enchufe provisto. Si el mismono penetrara el tomacorriente disponible, unelectricista competente deberb instalar unoapropiado.

    La reparacibn del cable o del enchufe DEBERAser efectuada por un electricista competente.

    Cables de extensi6n el_ctrica

    Use extensiones de manguera de aire antes que prolonga-ciones de cables electricos, a fin de prevenir cddas de ten-si6n, perdida de la potencia eDctrica al motor, y tambi6n surecalentamiento.

    Si - no obstante - debe utilizarse una extensi6n de cable,asegQresede que:

    • La extensi6n electrica de 3 conductores, tenga unenchufe de conexi6n a tierra de 3 hojas, y que existaun receptaculo que acepte el enchufe del producto.

    • Est6 en buenas condiciones.

    No m_.slargo que 15,2 m (50 pies).

    Calibre 14 (AWG)o mayor. (La medida de los cables seincrementa a medida que su nQmeroordinal decrece.12, 10, y 8 AWG pueden ser usados tambien. NO USE16 N118 AWG).

    Proteccion del voltaje y del circuito

    Acerca del voltaje y la minima cantidad de circuitosrequeridos, refi6rase al Manual de piezas.

    Ciertos compresores de aire pueden ser operados enun circuito de 15 A, siempre que se cumplan las sigu-ientes condiciones:

    1. Que el voltaje suministrado a trav6s de losramales del circuito sea de 15 A.

    2. Que el circuito no sea utilizado para alimentar ningunaotra necesidad el6ctrica (iluminaci6n, artefactos, etc.)

    3. Que los cables de extensi6n cumplan con lasespecificaciones.

    4. Que el circuito est6 equipado con un interrupterautom_.tico de 15 A, o un fusible de acci6n retar-dada de 15 A. NOTA: Si el compresor estuvieseconectado a un circuito protegido con fusibles,utilice solamente los de acci6n retardada identifi-cados come "U".

    Si cualquiera de las condiciones enumeradas no pud-iese ser cumplida, o si el funcionamiento del compre-sor causara reiteradas interrupciones de la energiacon la que se Io alimenta, podria ser necesario operaral mismo desde un circuito de 20 A. Para ello no ser_.necesario cambiar su cable de alimentaci6n.

    A08593 20- SP

  • Conozca su compresor de aire

    LEA ESTE MANUAL DEL PROPIETARIOY SUS NORMAS DE SEGURIDADANTES DE OPERARLA UNIDAD. Compare lasilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaciones. Conserve estemanual para referencias futuras.

    Interruptor ON/OFF

    Valvula

    reguladorapresibn

    Pico hembra

    para el inflado

    de los ,,_neumaticos

    rosca

    Picos de

    _ ::!¢_;°;:_; conex 6n_ " "

    ra ,o _ ...._.,_,,,_ .X, Tobera de segundadZbcalo para _ _/_ Adaptador para pistolaconexi6n rapida Inflador c6nico

    / sopladoraAguja para inflar

    Descripci6n de operaciones

    V&lvula reguladora de presibn: Lavalvulade presi6ncontrolala cantidadde presi6n que circuladesde el compresorde airealaccesorio.Lavalvulareguladorade presi6npermite regularlapresi6nen un tango entre 10y 125 PSI(125 PSIes el valor depresi6n maselevadoque puede entregarestecompresor).

    Interruptor de prendido y apagado (On/Off Iocalizado enel lado opuesto del compresor de aire): Usado paraprender y apagar el compresor de aire.

    Zbcalo para conexibn r_pida: Facilita el recambio r@idode las herramientas.

    Picos de conexibn r&pida: Instaladossobre las herramientase insertado en los z6calos de conexi6n r@ida, facilita larapidez del recambio de las herramientas.

    Cinta selladora para filetes de rosca: Usada para aplicarsobre los filetes a fin de eliminar las perdidas de aire.

    Pico hembra para el inflado de los neum_ticos:Adaptador para el inflado de neumaticos.

    Pistola sopladora: Ideal para soplar, limpiar e inflar.

    Tobera de seguridad: Previene el incremento de la presi6n.

    Adaptador para pistola sopladora: Conectado a la pistolasopladora o al extremo hembra de la manguera, permite eluso del pico c6nico del inflador o de la aguja para inflado.

    Aguja para inflado: Utilizada para el inflado de pelotasdeportivas.

    Inflador cbnico: Utilizado para el inflado de juguetesinflableso colchones de aire.

    21 - SP A08593

  • COmo utilizar su unidad [ Palanca Adaptador del sopladorI de manguera

    Cbmo detenerla:

    1. Coloque la posici6n de la Ilaveinterruptora On/Off en la posi-ci6n "OFF".

    COme utilizar zOcalos,yconectores de conexmnrdpida:

    1. Aplique cinta selladora sobrelos filamentos de los z6calosy conectores rapidos.

    2. Ensamble el conector rapidoa la manguera. Enchufe elconector a la pistola sopladoray al pico hembra parael infladode los neumaticos. AjOstelo firmemente.EIIo facilitara el cambio de dichos accesorios.

    3. Tire hacia atras la cupla de conexi6n del acoplamientor_.pidoe inserte el enchufe. Ver la figura de arriba.

    4. Deslice la cupla de acoplamiento a su posicion inicial.

    Cbmo utilizar el pico hembra para el inflado delos neumdticos

    1. Conecte a la manguera el pico hembra para inflado deneumaticos.

    2.

    3.

    4.

    Veael parrafo "come poner en marcha" el compresorde aire.

    Coloque el pico hembra de inflado de cubiertas sobreel tallo de la valvula de la cubierta que debe ser infiada.

    Incremente lentamente el nivel de presi6n de la valvulareguladora hasta el valor PSI recomendado por el fabri-cante de la cubierta. Nota: Para asegurar el valorcorrecto de la presi6n de inflado, utilice el calibrador depresi6n.

    Cbmo utilizar la pistola sopladora

    1. Conecte la pistola sopladora a la manguera.

    Si no se intenta utilizar accesorioalgunocon la pistolasopladora,DEBE ensamblarse la boquilla de Boquillade seguridadseguridad.

    2. Ensamble la boquilla de seguridad o el adaptador delextremo de la manguera a la pistola sopladora. Vea lapr6xima figura.

    NOTA" Para poder utilizar la aguja de inflar o el infladorcSnico,el adaptador del soplador debe estarensambladoa la pistola sopladora.A08593

    Aguja para inflar

    Inflador cbnico

    Boquilla de seguridad

    3. Conecte la aguja para inflar o el inflador c6nico aladaptador de la pistola sopladora.

    4. Vea el parrafo "come poner en marcha" para dararranque al compresor de aire.

    5. Presione la palanca de la pistola sopladora a fin depermitir el paso del aire.

    22 - SP

    Antes de comenzar:

    2.

    3.

    Coloqueel interruptorOn/Off en laposici6n "OFF".

    Lleve el control de

    la presi6n de lava.lvulareguladora ala posici6n 10 PSI.

    Conecte mangueras y accesorios.

    Demasiada presi6n de airecrea el riesgo de explosi6n.

    Verifiquelos valoresmaximos recomendados por elfabricante para las herramientas de aire y accesorios.Siga cuidadosamente las instrucciones dadas en"C6mo Poner en Marcha".

    Cbmo poner en marcha:

    I. Coloque el interruptor On/Off en la posici6n "OFF".

    2. Enchufe el cable de energia el6ctrica en un tomacorrienteconectado a tierra.

    3.

    4.

    5.

    Coloque el interruptor On/Off en la posici6n "ON" paradar arranque al compresor.

    Verifique los valores ma.ximosde presi6n admitidos porel fabricante, para la herramienta neumatica, accesorio ocubierta neumatica del vehiculo para la que sera usada.La salida de presi6n del compresor de aire jamas debeexceder los valores de presi6n estipulados.

    Incremente lentamente los valores de presi6n desde elregulador de la valvula de presi6n. Debera ustedescuchar y percibir la presi6n del aire que va siendoelevada por acci6n de la valvula reguladora. Si dichapresi6n no fuese liberada, apague inmediatamente elcompresor de aire. La va.lvulareguladora de la presi6ndebera ser reemplazada.

    Elaire comprimido provenientede la salida podra contener

    condensaci6n de agua. No rode aire sin filtrar sobre unarticulo que pudiese ser da_ado. AIgunas herramientaso dispositivos accionados por aire requieren aire filtrado.Lea las instrucciones dadas para las herramientasneumaticas o los accesorios.

  • Cambio de la manguera de aire

    La manguera de aire conectada a su compresor tieneuna v6.1vulapara su sistema integral de presi6n en elextremo de trabajo de la manguera. En caso de quefuese necesario el servicio o la reparaci6n fueserequerida, asegQrese de que la v_.lvula de regulaci6nde la presi6n se encuentre presente en la manguerade aire.

    NO reemplace lamanguera utilizando la

    manguera est_.ndar que no esta equipada con lav6.1vulareguladora de presi6n. El equipo demanguera apropiado para su compresor seencuentra disponible en Sears.

    No permita que la manguerase retuerza ni sea perforada

    en momento alguno. Esto es importante para evitardafios al compresor y para mantener el control dela v&lvula reguladora de presi6n.

    1. Coloque el interruptor On/Off en la posici6n"OFF" y desenchufe el conductor el@ctrico.

    2. Libere toda la presi6n del cabezal del compresorde aire y de la manguera, girando la v_.lvula depresi6n regulable a 10 PSI.

    3. Proteja el conductor el@ctrico y la manguera deaire de dafios, dobl_.ndolos flojamente alrededordel compresor de aire.

    4. Guarde el compresor de aire en un sitio limpio yseco.

    23- SP A08593

  • Las fuentes de tensi6n, partes en movimiento o fuentes de aire comprimido quedanexpuestas al reparar el compresor. EIIo podria ocasionar lesiones personales.

    Desenchufe el compresor antes de intentar cualquier reparaci6n.

    PROBLEMA

    P6rdidas de aire

    El compresor no entregasuficiente aire

    CAUSA

    Conexi6n suelta de la manguera

    Uso excesivamente prolongadodel aire

    CORRECClON

    Ajustar la conexi6n

    Disminuirla cantidadde uso deaire. Sucompresor no tiene suficiente capacidad paralos requerimientosdeaire a los que estasiendo sometido.

    El motor no trabaja

    AIta presi6n de descarga. No puedeser reducida.

    Orificio en la manguera

    Orificio en la manguera

    Estall6 el fusible; se dispar6 elinterruptor autom_.tico.

    El cable de extensi6n electrica tieneuna Iongitud o calibre err6neos.

    Conexiones el6ctricas sueltas.

    Fallas del motor.

    La v_.lvulade regulaci6n de la presi6nno funciona,

    Reemplace la manguera.

    Ajuste las conexiones

    1.

    2.

    3.

    4.

    5.

    Verifique la caja de fusiblesinspeccionando la existencia defusibles fundidos, y reemplace losnecesarios. Restablezca la posi-ci6n del interruptor automa.ticodel circuito. No utilice un fusible ointerruptor automatico de mayorvalor que el especificado para elramal de su circuito.

    Verifique que el fusible sea eladecuado. Debe utilizar fusiblesde acci6n retardada.

    Verifique el problema del sumin-istro de bajo voltaje.

    Verifique la extensidn del conduc-tor el6ctrico.

    Desconecte los otros artefactosel_ctricos que estuvieren operan-do en el ramal del circuito que lecorresponde al compresor.

    Verifique la extensi6n del conductorel6ctrico.

    Verifique la conexi6n en la caja terminal

    Contacte a un tecnico calificado enservicio

    Riesgode

    explosi6n. NO opere el compresor sieste problema existiera. Debera reem-plazarse la valvula de regulaci6n de lapresi6n.

    A08593 24 - SP

  • 25-SP A08593

  • A08593 26-SP

  • 27-SP A08593

  • iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_HHHHHHHHH

    iiiiiiiiiiiiiiiiiiii_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii,,,iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii

    Your Home

    For repair- in your home - of all major brand appliances,lawn and garden equipment, or heating and cooling systems,

    no matter who made it, no matter who sold it!

    For the replacement parts, accessories andowner's manuals that you need to do-it-yourself.

    For Sears professional installation of home appliancesand items like garage door openers and water heaters.

    1-800-4-MY-HOME ® Anytime, day or night(1-800-469-4663) (U.S.A. and Canada)www.sears.com www.sears.ca

    Our Home

    For repair of carry-in products like vacuums, lawn equipment,and electronics, call or go on-line for the nearest

    Sears Parts and Repair Center.

    1-800-488-1222 Anytime, day or night (U.S.A. only)www.sears.com

    To purchase a protection agreement (U.S.A.)or maintenance agreement (Canada) on a product serviced by Sears:

    1-800-827-6655 (U.S.A.) 1-800-361-6665 (Canada)

    Para pedir servicio de reparaciona domicilio, y para ordenar piezas:

    Au Canada pour service en fran(_ais:

    1-800--LE-FOYER Mc(1-800-533-6937)www.sears.ca

    6 AR, © Sears, Roebuck and Co.

    ® Registered Trademark / TMTrademark / SMService Mark of Sears, Roebuck and Co.

    ® Marca Registrada / TMMarca de Fa.brica / SMMarca de Servicio de Sears, Roebuck and Co.

    MCMarque de commerce / MDMarque depos6e de Sears, Roebuck and Co.