NARROMINE 4A NRM4A - DEVELOPMENT APPLICATION ADDRESS: CLIENT: ITP DEVELOPMENT NARROMINE NSW 2821 6 EUROMEDAH RD. AUSTRALIA SHEET LIST SHEET NUMBER SHEET TITLE G-010 MAIN TITLE SHEET G-040 LOCATION PLAN G-210 GENERAL ARRANGEMENT C-130 SITE ELEVATION C-430 INVERTER STATION FOOTING DETAIL C-530 TYPICAL FENCING DETAIL C-631 ACCESS ROAD DETAIL E-341 TYPICAL ARRAY DETAIL E-430 TYPICAL INVERTER STATION DETAIL
9

E-430 TYPICAL INVERTER STATION DETAIL

Dec 24, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: E-430 TYPICAL INVERTER STATION DETAIL

NARROMINE 4A

NRM4A - DEVELOPMENT APPLICATION

ADDRESS:

CLIENT:

ITP DEVELOPMENT

NARROMINE NSW 2821

6 EUROMEDAH RD.

AUSTRALIA

SHEET LIST

SHEET NUMBER SHEET TITLE

G-010 MAIN TITLE SHEET

G-040 LOCATION PLAN

G-210 GENERAL ARRANGEMENT

C-130 SITE ELEVATION

C-430 INVERTER STATION FOOTING DETAIL

C-530 TYPICAL FENCING DETAIL

C-631 ACCESS ROAD DETAIL

E-341 TYPICAL ARRAY DETAIL

E-430 TYPICAL INVERTER STATION DETAIL

Page 2: E-430 TYPICAL INVERTER STATION DETAIL

© 2019 Microsoft Corporation © 2019 DigitalGlobe ©CNES (2019) Distribution Airbus DS

ADDRESS

CLIENT

PROJECT

P: +61 2 6257 3511

[email protected]

www.itpau.com.au

PO BOX 6217

O'CONNOR, ACT 2602

AUSTRALIA

DO NOT SCALE.

ALL MEASUREMENTS IN MM UNLESS

OTHERWISE STATED.

THIS DOCUMENT MAY ONLY BE

USED BY CLIENTS OF ITP OR THOSE

WHO HAVE RECEIVED EXPRESS

PERMISSION FROM ITP. THE USE OF

THIS DRAWING SHALL NOT EXTEND

BEYOND THE PURPOSE FOR WHICH

IT WAS ORIGINALLY PREPARED.

NO. STAGE DATE

1

2

3

4

5

6

DRAWN

CHECKED

APPROVED

DRAWING

DRAWING NO. REV NO.

SCALE

SHEET SIZE

ORIG. DATE

REV. DATE

NOTES

g:\itp solar farm development\a5000 engineering team\6 site-specific work\nrm4a narromine 4a\4 system design\4.01 cad\LOCATION PLAN.dwg, PLOTTED BY WOOKYEUNG JOE AT 5/7/2019 2:18 PM

NARROMINE 4A

ITP DEVELOPMENT

6 EUROMEDAH RD.

NARROMINE NSW 2821, AUSTRALIA

KB

LF

WJ

LOCATION PLAN

----

NRM4A-G-040 01.1

AS NOTED

A3

21/1/19

13/6/19

DEVELOPMENT APPLICATION

PARTNERS

####

####

####

####

####

####

####

####

####

####

####

####

SCALE: 1:100,000

LOCATION MAP1

-

SCALE: 1:10,000

LOCATION PLAN2

-

SOLAR FARM

FENCED AREA

DEVELOPMENT AREA

BOUNDARY

Page 3: E-430 TYPICAL INVERTER STATION DETAIL

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

T

T

hh

hhh

hh

h h

1

C-130

1

C-130

20m EASEMENT

22KV NETWORK

CONNECTION POINT

EXISTING

22KV LINE

DEVELOPMENT AREA

BOUNDARY

LAY DOWN AREA

FOR CONSTRUCTION

GRAVEL ROAD

STONE PILES TO BE REMOVED

STONE PILES TO BE REMOVED

PROPOSED SECONDARY VEHICLE ACCESS

PROPOSED MAIN

VEHICLE ACCESS

LAY DOWN AREA FOR

CONSTRUCTION

SITE DATUM

VEGETATION

ARRAY SECURITY FENCE

20.1 m

20.2 m

20 m

20 m

PROPOSED CAR PARK SPACE

DURING CONSTRUCTION

2

C-130

2

C-130

INVERTER

LOCATION

ADDRESS

CLIENT

PROJECT

P: +61 2 6257 3511

[email protected]

www.itpau.com.au

PO BOX 6217

O'CONNOR, ACT 2602

AUSTRALIA

DO NOT SCALE.

ALL MEASUREMENTS IN MM UNLESS

OTHERWISE STATED.

THIS DOCUMENT MAY ONLY BE

USED BY CLIENTS OF ITP OR THOSE

WHO HAVE RECEIVED EXPRESS

PERMISSION FROM ITP. THE USE OF

THIS DRAWING SHALL NOT EXTEND

BEYOND THE PURPOSE FOR WHICH

IT WAS ORIGINALLY PREPARED.

NO. STAGE DATE

1

2

3

4

5

6

DRAWN

CHECKED

APPROVED

DRAWING

DRAWING NO. REV NO.

SCALE

SHEET SIZE

ORIG. DATE

REV. DATE

NOTES

g:\itp solar farm development\a5000 engineering team\6 site-specific work\nrm4a narromine 4a\4 system design\4.01 cad\G-210 GENERAL ARRANGEMENT PLAN.dwg, PLOTTED BY WOOKYEUNG JOE AT 5/7/2019 2:18 PM

NARROMINE 4A

ITP DEVELOPMENT

6 EUROMEDAH RD.

NARROMINE NSW 2821, AUSTRALIA

KB

LF

WJ

GENERAL ARRANGEMENT

----

NRM4A-G-210 02.1

AS NOTED

A3

29/11/18

5/7/19

DEVELOPMENT APPLICATION

PARTNERS

####

####

####

####

####

####

####

####

####

####

####

####

SCALE: 1:5000

GENERAL ARRANGEMENT1

-

PROJECT INFORMATION

DC CAPACITY 6.048 MW

AC CAPACITY 5.0 MW

DC/AC RATIO 1.2

INVERTERS 2 x 2.5 MW AC

MOUNTING NEXTRACKER SINGLE AXIS TRACKER (1V)

MODULE CAPACITY 385 W - 72 CELL MONO (1500 V)

STRING CONFIGURATION 28 MODULES PER STRING

TRACKER 3-STRING: 88 m. 2-STRING: 60m

NO. TRACKERS 187x 3-STRING TRACKERS

TRACKER SPACING (N-S) 1 m

ARRAY PITCH 6 m

SPECIFIC YIELD 2133 kWh/kWp/year

ANNUAL GENERATION 12.98 GWh

CONNECTION VOLTAGE 22 kV

CONNECTION FEEDER EXISTING ESSENTIAL ENERGY FEEDER

NME8B5

CONNECTION SUBSTATION EXISTING ESSENTIAL ENERGY

NARROMINE SUBSTATION

SECURITY FENCE SETBACK 3m FROM DEVELOPMENT AREA

BOUNDARY

ARRAY SETBACK 20m FROM SECURITY FENCE

ACCESS ROAD WIDTH 10m

SITE INFORMATION

LOT / DP 46/752581 and 41/752581

ADDRESS 6 EUROMEDAH RD, NARROMINE NSW

2821

LGA NARROMINE SHIRE

LAT / LONG -32.22612, 148.30002

ELEVATION 236 m

LOT AREA 32.3 ha

FENCED AREA 15.6 ha

DNSP ESSENTIAL ENERGY

Page 4: E-430 TYPICAL INVERTER STATION DETAIL

DEVELOPMENT AREA

BOUNDARY

ARRAY SECURITY FENCE

3 m 101.6 m

EXISTING 22kV POLE

259.8 m

INDICATIVE MAXIMUM

ARRAY HEIGHT

6 m (TYPICAL)

DEVELOPMENT

AREA

BOUNDARY

3 m

ARRAY

SECURITY FENCE

31.6 m

2.1 m2.6 m

EXISTING 22 kV LINE

(MIN. 7.3m CLEARANCE TO GROUND)

9.3 m 6 m 3.5 m

0.9 m

ARRAY SECURITY FENCE

MAIN ACCESS GATEINDICATIVE MAXIMUM

ARRAY HEIGHT

2.1 m

6 m 3.5 m

0.9 m

92 m

SECONDARY VEHICLE

ACCESS

ARRAY

SECURITY

FENCE

288.8 m

2.6 m

ADDRESS

CLIENT

PROJECT

P: +61 2 6257 3511

[email protected]

www.itpau.com.au

PO BOX 6217

O'CONNOR, ACT 2602

AUSTRALIA

DO NOT SCALE.

ALL MEASUREMENTS IN MM UNLESS

OTHERWISE STATED.

THIS DOCUMENT MAY ONLY BE

USED BY CLIENTS OF ITP OR THOSE

WHO HAVE RECEIVED EXPRESS

PERMISSION FROM ITP. THE USE OF

THIS DRAWING SHALL NOT EXTEND

BEYOND THE PURPOSE FOR WHICH

IT WAS ORIGINALLY PREPARED.

NO. STAGE DATE

1

2

3

4

5

6

DRAWN

CHECKED

APPROVED

DRAWING

DRAWING NO. REV NO.

SCALE

SHEET SIZE

ORIG. DATE

REV. DATE

NOTES

g:\itp solar farm development\a5000 engineering team\6 site-specific work\nrm4a narromine 4a\4 system design\4.01 cad\C-130 SITE ELEVATION.dwg, PLOTTED BY WOOKYEUNG JOE AT 5/7/2019 2:18 PM

NARROMINE 4A

ITP DEVELOPMENT

6 EUROMEDAH RD.

NARROMINE NSW 2821, AUSTRALIA

KB

LF

WJ

SITE ELEVATION

----

NRM4A-C-130 01.1

AS NOTED

A3

23/1/19

13/6/19

DEVELOPMENT APPLICATION

PARTNERS

####

####

####

####

####

####

####

####

####

####

####

####

SCALE: 1:200

SITE ELEVATION (NORTH)1

G-210

SCALE: 1:200

SITE ELEVATION (EAST)2

G-210

Page 5: E-430 TYPICAL INVERTER STATION DETAIL

SETOUT DATUM

6414 5474

2337

601

500

648 750

GRAVEL NOM.

20mm DIAMETER

STEEL PILE FOOTINGS

POWER SKID BASE

SHOWN INDICATIVELY

SCALE: 1:50

TYPICAL FOOTING PLAN1

C-430

2

C-430

2

C-430

200

POWER SKID BASE

SHOWN INDICATIVELY

STEEL DRIVEN PILE TO BE SPECIFIED

BY STRUCTURAL ENGINEER

SCALE: 1:50

TYPICAL FOOTING SIDE SECTION2

C-430

13286

100

FINISHED GRADE

3

C-430

FINISHED GRADEPOWER SKID BASE

SHOWN INDICATIVELY

SCALE: 1:50

TYPICAL FOOTING END SECTION3

C-430

STEEL DRIVEN PILE TO BE SPECIFIED

BY STRUCTURAL ENGINEER

ADDRESS

CLIENT

PROJECT

P: +61 2 6257 3511

[email protected]

www.itpau.com.au

PO BOX 6217

O'CONNOR, ACT 2602

AUSTRALIA

DO NOT SCALE.

ALL MEASUREMENTS IN MM UNLESS

OTHERWISE STATED.

THIS DOCUMENT MAY ONLY BE

USED BY CLIENTS OF ITP OR THOSE

WHO HAVE RECEIVED EXPRESS

PERMISSION FROM ITP. THE USE OF

THIS DRAWING SHALL NOT EXTEND

BEYOND THE PURPOSE FOR WHICH

IT WAS ORIGINALLY PREPARED.

NO. STAGE DATE

1

2

3

4

5

6

DRAWN

CHECKED

APPROVED

DRAWING

DRAWING NO. REV NO.

SCALE

SHEET SIZE

ORIG. DATE

REV. DATE

NOTES

g:\itp solar farm development\a5000 engineering team\6 site-specific work\nrm4a narromine 4a\4 system design\4.01 cad\C-430 INVERTER STATION FOOTING DETAIL.dwg, PLOTTED BY WOOKYEUNG JOE AT 5/7/2019 2:18 PM

NARROMINE 4A

ITP DEVELOPMENT

6 EUROMEDAH RD.

NARROMINE NSW 2821, AUSTRALIA

KB

LF

WJ

INVERTER STATION FOOTING DETAIL

----

NRM4A-C-430 01.1

AS NOTED

A3

20/5/19

13/6/19

DEVELOPMENT APPLICATION

PARTNERS

####

####

####

####

####

####

####

####

####

####

####

####

Page 6: E-430 TYPICAL INVERTER STATION DETAIL

DIAGONAL TWIN 3.15mm

TWISTED CABLE WIRE

WITH 12mm GALVANIZED

TURNBUCKLE

BRACING RAIL

DN32 CLASS 2 L/G PIPE

SUPPORT CABLES

4.00mm SINGLE STRAND TENSION

WIRE STRAINED TAUT TO BETWEEN

1.0 AND 1.2kN TENSION

NOM. 15 - 50mm

250

750

250

CORNER PANELINTERMEDIATE (REGULAR) PANEL

CORNER POST

DN50 CLASS 2

M/G PIPE

BARBED WIRE 3 ROWS OF 1.57mm

TWISTED WIRED FIXED TO CRIMPED

POSTS AT 150mm CENTERS

3300

INTERMEDIATE POST

DN40 CLASS 2 L/G PIPE

2.50mm GALVANIZED WIRE

CHAIN LINK WITH 50mm PITCH

(W10Z)

750

600

250

750

250

750

250

3300

INTERMEDIATE

POST

DN40 CLASS 2

L/G PIPE

STRAINER POST

DN50 CLASS 2

M/G PIPE

3300

INTERMEDIATE

POST

DN40 CLASS 2

L/G PIPE

INTERMEDIATE (REGULAR) PANEL INTERMEDIATE STRAINING PANEL INTERMEDIATE (REGULAR) PANEL

SHALL BE BRACED AT NOT

MORE THAN 150m INTERVALS

ON STRAIGHT LENGTHS

STRAINER

POST

DN50 CLASS 2

M/G PIPE

1700

400

300

4

5

°

FENCE AND GATES TO BE DESIGNED AND CONSTRUCTED TO AS 1725 PART 1

SCALE: 1:50

TYPICAL FENCE SECTION1

-

STRAINER POST

DN50 CLASS 2

M/G PIPE

2.50mm GALVANIZED WIRE CHAIN

LINK WITH 50MM PITCH (W10Z)

DIAGONAL TWIN 3.15mm

TWISTED CABLE WIRE

WITH 12mm GALVANIZED

TURNBUCKLE

BRACING RAIL

DN32 CLASS 2 L/G PIPE

SCALE: 1:50

INTERMEDIATE STRAINING PANEL FENCE SECTION2

-

6090

3000 3000

DIAGONAL TWIN 3.15mm

TWISTED CABLE WIRE

WITH 12mm GALVANIZED

TURNBUCKLE

BRACING RAIL

DN32 CLASS 2 L/G PIPE

1000

300

150

400 x 400 x 300mm IN-SITUE CONCRETE

PAD INSET WITH 2 OF DN25 KEEPERS FOR

DROP BOLTS

2 OF 16mm ROUND GALV. STEEL DROP

BOLTS WELDED TO GATE FRAME

1700

2100

SCALE: 1:50

DOUBLE LEAF 6 METER GATE SECTION3

-

GATE OUTER FRAME

DN32 CLASS 2 L/G PIPE

GATE INNER FRAME

DN25 CLASS 2 L/G PIPE

1 HORIZONTAL MEMBER AND

2 VERTICAL MEMBERS

TOP DIAGONAL BRACE

DN20 CLASS 2 L/G PIPE

GATE POST

DN80 CLASS 2 M/G PIPE

350

900

1000

300

1700

2100

SCALE: 1:50

SINGLE LEAF GATE SECTION4

-

DIAGONAL TWIN 3.15mm

TWISTED CABLE WIRE

WITH 12mm GALVANIZED

TURNBUCKLE

BRACING RAIL

DN32 CLASS 2 L/G PIPE

GATE OUTER FRAME

DN25 CLASS 2 L/G PIPE

GATE INNER FRAME

DN20 CLASS 2 L/G PIPE

1 HORIZONTAL MEMBER

TOP DIAGONAL BRACE

DN20 CLASS 2 L/G PIPE

GATE POST

DN50 CLASS 2 M/G PIPE

TOP CABLE POSITION

BOTTOM CABLE POSITION

NOM. 50 PITCH

NOM. 50 PITCH

2.50 HEAVILY GALV.

WIRE CODE W10Z

BARBED SELVEDGE

KNUCKLED SELVEDGE

ADDRESS

CLIENT

PROJECT

P: +61 2 6257 3511

[email protected]

www.itpau.com.au

PO BOX 6217

O'CONNOR, ACT 2602

AUSTRALIA

DO NOT SCALE.

ALL MEASUREMENTS IN MM UNLESS

OTHERWISE STATED.

THIS DOCUMENT MAY ONLY BE

USED BY CLIENTS OF ITP OR THOSE

WHO HAVE RECEIVED EXPRESS

PERMISSION FROM ITP. THE USE OF

THIS DRAWING SHALL NOT EXTEND

BEYOND THE PURPOSE FOR WHICH

IT WAS ORIGINALLY PREPARED.

NO. STAGE DATE

1

2

3

4

5

6

DRAWN

CHECKED

APPROVED

DRAWING

DRAWING NO. REV NO.

SCALE

SHEET SIZE

ORIG. DATE

REV. DATE

NOTES

g:\itp solar farm development\a5000 engineering team\6 site-specific work\nrm4a narromine 4a\4 system design\4.01 cad\C-530 TYPICAL FENCING DETAIL.dwg, PLOTTED BY WOOKYEUNG JOE AT 5/7/2019 2:19 PM

NARROMINE 4A

ITP DEVELOPMENT

6 EUROMEDAH RD.

NARROMINE NSW 2821, AUSTRALIA

KB

LF

WJ

TYPICAL FENCING DETAIL

----

NRM4A-C-530 01

AS NOTED

A3

23/1/19

13/6/19

DEVELOPMENT APPLICATION

PARTNERS

####

####

####

####

####

####

####

####

####

####

####

####

Page 7: E-430 TYPICAL INVERTER STATION DETAIL

4000 400400

100

150

3000

150

FINISHED GRADE

4

:1

33:133:1

4

:1

WEARING COURSE MIN 100mm THICKNESS

40mm MAX CLASS 3 CRUSHED ROCK

BASE COURSE MIN 150mm THICKNESS 55mm MAX

NATURAL GRAVELS, PIT MATERIALS OR QUARRY WASTE

NATURAL SUB-GRADE

WEARING COURSE MIN 150mm THICKNESS 50mm MAX

NATURAL GRAVELS, PIT MATERIALS OR QUARRY WASTE

NATURAL SUB-GRADE

33:133:1

FINISHED GRADE

SCALE: 1:50

CROSS SECTION - PRIMARY ROAD1

-

SCALE: 1:50

CROSS SECTION - SECONDARY ROAD2

-

500

150

500

DRAINAGE

CHANNEL

SCALE: 1:500

TYPICAL TURNING DETAIL PLAN3

-

R

2

0

0

0

0

4000

ADDRESS

CLIENT

PROJECT

P: +61 2 6257 3511

[email protected]

www.itpau.com.au

PO BOX 6217

O'CONNOR, ACT 2602

AUSTRALIA

DO NOT SCALE.

ALL MEASUREMENTS IN MM UNLESS

OTHERWISE STATED.

THIS DOCUMENT MAY ONLY BE

USED BY CLIENTS OF ITP OR THOSE

WHO HAVE RECEIVED EXPRESS

PERMISSION FROM ITP. THE USE OF

THIS DRAWING SHALL NOT EXTEND

BEYOND THE PURPOSE FOR WHICH

IT WAS ORIGINALLY PREPARED.

NO. STAGE DATE

1

2

3

4

5

6

DRAWN

CHECKED

APPROVED

DRAWING

DRAWING NO. REV NO.

SCALE

SHEET SIZE

ORIG. DATE

REV. DATE

NOTES

g:\itp solar farm development\a5000 engineering team\6 site-specific work\nrm4a narromine 4a\4 system design\4.01 cad\C-631 ACCESS ROAD DETAIL.dwg, PLOTTED BY WOOKYEUNG JOE AT 5/7/2019 2:19 PM

NARROMINE 4A

ITP DEVELOPMENT

6 EUROMEDAH RD.

NARROMINE NSW 2821, AUSTRALIA

KB

LF

WJ

ACCESS ROAD DETAIL

----

NRM4A-C-631 01.1

AS NOTED

A3

20/5/19

13/6/19

DEVELOPMENT APPLICATION

PARTNERS

####

####

####

####

####

####

####

####

####

####

####

####

Page 8: E-430 TYPICAL INVERTER STATION DETAIL

7221 8230 8230 8230 8230 8034 8034 8230 8234 8230 7221

FINISHED GRADE

SCALE: 1:500

TYPICAL ARRAY PLAN - 84 MODULE TRACKER1

E-341

SCALE: 1:500

TYPICAL ARRAY ELEVATION - 84 MODULE TRACKER3

E-341

TRACKING PILES

48450

88660

40210

46 MODULES 38 MODULES

19720 40210

59930

18 MODULES 38 MODULES

SCALE: 1:500

TYPICAL ARRAY PLAN - 56 MODULE TRACKER2

E-341

3

E-341

3

E-341

4

E-341

4

E-341

5

E-341

2 2

3

6

0

°

PILE DEPTH SUBJECT TO CONFIRMATION BY

STRUCTURAL ENGINEER FOLLOWING

GEO-TECHNICAL INVESTIGATION

DEPENDING ON SOIL CONDITIONS A Ø300mm

CONCRETE COLLAR MAY BE NECESSARY

1

9

5

9

SCALE: 1:50

TYPICAL ARRAY SECTION5

E-341

TY

P. 1

50

09

00

15

26

17

85

26

17

FINISHED

GRADE

ADDRESS

CLIENT

PROJECT

P: +61 2 6257 3511

[email protected]

www.itpau.com.au

PO BOX 6217

O'CONNOR, ACT 2602

AUSTRALIA

DO NOT SCALE.

ALL MEASUREMENTS IN MM UNLESS

OTHERWISE STATED.

THIS DOCUMENT MAY ONLY BE

USED BY CLIENTS OF ITP OR THOSE

WHO HAVE RECEIVED EXPRESS

PERMISSION FROM ITP. THE USE OF

THIS DRAWING SHALL NOT EXTEND

BEYOND THE PURPOSE FOR WHICH

IT WAS ORIGINALLY PREPARED.

NO. STAGE DATE

1

2

3

4

5

6

DRAWN

CHECKED

APPROVED

DRAWING

DRAWING NO. REV NO.

SCALE

SHEET SIZE

ORIG. DATE

REV. DATE

NOTES

g:\itp solar farm development\a5000 engineering team\6 site-specific work\nrm4a narromine 4a\4 system design\4.01 cad\E-341 TYPICAL ARRAY DETAIL.dwg, PLOTTED BY WOOKYEUNG JOE AT 5/7/2019 2:19 PM

NARROMINE 4A

ITP DEVELOPMENT

6 EUROMEDAH RD.

NARROMINE NSW 2821, AUSTRALIA

KB

LF

WJ

TYPICAL ARRAY DETAIL

----

NRM4A-E-341 01.1

AS NOTED

A3

23/1/19

13/6/19

DEVELOPMENT APPLICATION

PARTNERS

####

####

####

####

####

####

####

####

####

####

####

####

SCALE: 1:50

TYPICAL ARRAY SECTION3

-

SCALE: 1:50

TYPICAL ARRAY ELEVATION - 84 MODULE TRACKER2

E-341

Page 9: E-430 TYPICAL INVERTER STATION DETAIL

SCALE: 1:50

PLAN VIEW1

-

12192

24

38

INVERTER 01 TRANSFORMER INVERTER 02 MVSG

2

E-430

2

E-430

LVSG ACCESS

27

00

INVERTER 01 LV & MV SWITCHGEAR

CABINETS

TRANSFORMER INVERTER 02

38

0

20

0

26

81

28

80

SCALE: 1:50

SIDE ELEVATION2

E-430

3

E-430

3

E-430

FINISHED GRADEINVERTER STATION SKID BASE WITH INTEGRATED

TRANSFORMER OIL CONTAINMENT

29

78

SCALE: 1:50

END ELEVATION3

E-430

FINISHED

GRADE

ADDRESS

CLIENT

PROJECT

P: +61 2 6257 3511

[email protected]

www.itpau.com.au

PO BOX 6217

O'CONNOR, ACT 2602

AUSTRALIA

DO NOT SCALE.

ALL MEASUREMENTS IN MM UNLESS

OTHERWISE STATED.

THIS DOCUMENT MAY ONLY BE

USED BY CLIENTS OF ITP OR THOSE

WHO HAVE RECEIVED EXPRESS

PERMISSION FROM ITP. THE USE OF

THIS DRAWING SHALL NOT EXTEND

BEYOND THE PURPOSE FOR WHICH

IT WAS ORIGINALLY PREPARED.

NO. STAGE DATE

1

2

3

4

5

6

DRAWN

CHECKED

APPROVED

DRAWING

DRAWING NO. REV NO.

SCALE

SHEET SIZE

ORIG. DATE

REV. DATE

NOTES

g:\itp solar farm development\a5000 engineering team\6 site-specific work\nrm4a narromine 4a\4 system design\4.01 cad\E-430 TYPICAL INVERTER STATION DETAIL.dwg, PLOTTED BY WOOKYEUNG JOE AT 5/7/2019 2:19 PM

NARROMINE 4A

ITP DEVELOPMENT

6 EUROMEDAH RD.

NARROMINE NSW 2821, AUSTRALIA

KB

LF

WJ

TYPICAL INVERTER STATION DETAIL

----

NRM4A-E-430 01.1

AS NOTED

A3

20/5/19

13/6/19

DEVELOPMENT APPLICATION