Rev Drawn Revisions Approved juwi Inc. 1710 29th St. Suite 1068 Boulder, CO 80301 www.juwiamericas.com PROPRIETARY AND CONFIDENTIAL ISSUED BY: JOB #: SCALE: DWG #: DWG TITLE: PRINT SIZE: TO BE REPRODUCED IN COLOR DRAWN BY: LATEST REV: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 SITE DEVELOPMENT PLAN PCD EA NUMBER: 17-46 A TRACT LOCATED IN SECTIONS 22, 26, 27, 28, 35, TOWNSHIP 16 SOUTH, ALL IN RANGE 65 WEST OF THE SIXTH PRINCIPAL MERIDIAN, EL PASO COUNTY, COLORADO PALMER SOLAR PROJECT AND WILLIAMS CREEK SUBSTATION 60.00 MW AC EL PASO COUNTY, CO BC B T:\CO404 - CSU\ENGINEERING\01 Drawings\01 AutoCAD Working Drawings\01 Title\11 Project Elevations.dwg Arch D JSI CO404 NTS 11 Project Elevations A BC 2/8/19 -- SCALE: TYPICAL TRACKING ARRAY-FRONT AND SIDE ELEVATIONS 11 1 NTS SCALE: POWER STATION-FRONT AND SIDE ELEVATIONS 11 2 NTS INVERTER CONCRETE PAD WIND SENSOR MV TRANSFORMER 200'-225' 7'-8" 4'-8' SOLAR PANEL INVERTER POWER STATION TRACKING AND ARRAY CONTROLS 33'-38' 14' MAX 5'-10' 11'-13' 2' 19'-20' RAMMED PILE FOUNDATION (TYP.) POLYCRYSTALLINE SOLAR MODULE (TYP.) POWER STATION TRACKING AND ARRAY CONTROLS WIND SENSOR MV TRANSFORMER DC COMBINER MPT TRANSFORMER SCALE: O&M/STORAGE SHED-FRONT AND SIDE ELEVATIONS 11 3 NTS 15'-25' 10'-14' 22'-26' 38'-42' B BC 2/11/19 --
9
Embed
TYPICAL TRACKING ARRAY-FRONT AND SIDE ELEVATIONS 1 · typical tracking array-front and side elevations 11 1 nts scale: power station-front and side elevations 11 2 nts inverter concrete
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
be disclosed and registeredwith juwi site representative
SECURITY
3" LETTERING
BLACK LETTERING WITH
WHITE BACKGROUND
H10
H11
NO
TRESPASSING
VIOLATORS
WILL BE
PROSECUTED
H01
H08
H09
H04
H05
H14
H15
H03
H12
H06
H07
BLUE IS 3M
REFLECTIVE VINYL
5
1
2
" LETTERING
4
1
4
" LETTERING
H02
H21
H19
H20
H17
H26
H28
H18
H16
This site is subject to access authorization
and control procedures
60.00 MW AC Photovoltaic Generation Facility
H29
H23
PALMER SOLAR
H13
H22
S
A
M
P
L
E
H30
H31
PS##.D##
Vmpp - 39.0 A Voc - 47.7 V
Impp - 9.49 A Isc - 10.04 A
H27
Site address:
Phone Number:
???
???
720-838-2323
H25
PS##.WS J-BOX
WEATHER STATION JUNCTION BOX
PS##.SEN## J-BOX
MONITORING SENSORS JUNCTION BOX
PS##.EWSA##
WIND STOW ANEMOMETER
10
1
2
H24
ONLY AUTHORIZED
PERSONNEL MAY ENTER
THE AREA BEYOND THIS
CHECKPOINT
SQUIRREL CREEK SOLAR
DELIVERIES
PS##.MTR##
Voltage - 480 V
PS##.E1
INVERTER
3,360 kVA, 34.5/19.9 kV (G-WYE) - 630 V (DELTA)
TRANSFORMER T1
PS##.MTR##
Row #
PS##.MPT1
MOTOR POWER TRANSFORMER
630V (DELTA) - 480V (G-WYE)
PS###.SCADA
SCADA ENCLOSURE
MOTOR POWER TRANSFORMER
DISCONNECT
ENERGIZED WORK PROHIBITED
KEY # DESCRIPTION SIGN LOCATION INSTALLER MATERIAL FONT/SIZE QUANTITY
SIGN AND LABEL SCHEDULE
H32
BIRDSALL SOLAR
DELIVERIES
H01 No Trespassing sign - Metal - 18" x 12" GATE/FENCE EVERY 200' Fence STEEL/ALUMINUM ARIAL/2" 196H02 Danger high voltage sign, English and Spanish - Metal - 6" x 12" GATE/FENCE EVERY 200' Fence STEEL/ALUMINUM ARIAL/2" 196H03 Site Identification Sign - Metal - 60" x 36" ENTRANCE Fence STEEL/ALUMINUM SEE DETAIL 3H04 Safety Sign - Metal - 36" x 36" ENTRANCE Fence STEEL/ALUMINUM SEE DETAIL 2H05 PPE Caution Sign - Metal 14.4" x 24" ENTRANCE Fence STEEL/ALUMINUM SEE DETAIL 3H06 Hazardous material declaration sign - Metal - 24" x 12" ENTRANCE Fence STEEL/ALUMINUM SWIS721/0.35" 2H07 PPE Sign - Metal - 48" x 96" ENTRANCE Fence STEEL/ALUMINUM SEE DETAIL 3H08 Check in sign - Metal - 24" x 24" ENTRANCE Fence STEEL/ALUMINUM SEE DETAIL 2H09 Only Authorized Personnel - Metal - 18" x 24" ENTRANCE AND ENTRANCE ROAD Civil STEEL/ALUMINUM SEE DETAIL 2H10 Birdsall Solar Deliveries - Metal - 36" x 72" RECEIVING AREA Civil STEEL/ALUMINUM SEE DETAIL 2H11 Squirrel Creek Solar Delivieries - Metal - 36" x 72" RECEIVING AREA Civil STEEL/ALUMINUM SEE DETAIL 2H12 Security sign - Metal - 24" x 12" SECURITY TRAILER Fence STEEL/ALUMINUM ARIAL/3" 2H13 No Cell Phone Use While Driving - 16" x 24" ENTRANCE ROAD Fence STEEL/ALUMINUM SEE DETAIL 2H14 Speed Limit Sign - 24" x 30" ENTRANCE ROAD Fence STEEL/ALUMINUM NA 2H15 Stop Sign - Metal - 30" x 30" ENTRANCE ROAD Fence STEEL/ALUMINUM NA 5H16 DC/AC Electric shock hazard sticker DCB DOOR, INVERTER AC/DC Electrical FLEXIBLE VINYL SEE DETAIL 294H17 Inverter Electric shock hazard sticker INVERTER (NEAR GROUND FAULT INDICATOR) Electrical FLEXIBLE VINYL SEE DETAIL 42H18 Transformer Switch Warning Sticker - Vinyl - 6"x 10" TRANSFORMER SWITCH Electrical FLEXIBLE VINYL ARIAL, VARIES 21
H19 Arc flash label - Vinyl - 5" x 3" DCB DOOR, INVERTER AC/DC, TRANSFORMER,SWITCH GEAR, SE, MPT, MOTOR Electrical FLEXIBLE VINYL SEE DETAIL LOT
H28 Energized Work Prohibited - Vinyl - 12" x 3" DCB, RCB, INVERTER AC AND DC CABINETS,TRANSFORMER LV BUS DUCT Electrical SELF LAMINATING VINYL ARIAL, VARIES 462
H29 Weather Station Junction Box nameplate label - Phenolic - 4" x 2" WEATHER STATION JUNCTION BOX Electrical PVC SWIS721/0.625"/0.25" 2
EAST 1/4 CORNER SEC. 272-1/2" ALUMINUM CAPSTAMPED "LS 22095"
FLUSH
ACCEPTED CENTER 1/4 CORNER OF SEC. 26
NO. 6 REBAR W/ BROKEN CAPFLUSH
N: 1290783.78
N88°50'18"E 2633.37'(M)N88°48'56"E 2624.75'(R)
N88°48'46"E 2605.40'(M) S2605.40'(M)
N88°48'46"E
APN: 5600000123OWNER: CITY OF COLORADO SPRINGS
WSEO LEASEAREA BOUNDARY
WSEO LEASEAREA BOUNDARY
WSEO LEASEAREA BOUNDARY
WSEO LEASEAREA BOUNDARY
12
2.37
'N
00°
31'
16 "
W
S
N89°12'01"E 4051.24'
N0
0°3
1'1
6 "W
230
.97
'
N89°22'23"E 460.00'
N0
0°3
7 '3
7"W
675
.42
'
WILLIAMS CREEK SUBSTATION
12 PALMER SUBSTATION
PI 0
+00.0
00
°00'0
0"
PI
16
+72
.05
8°5
8'1
7"
PI
18
+30
.05
0°0
0'0
0"
10+
00
APR
APAP
APO
RIG
INAL
ISSU
E (7
18-4
69)
ISSUED BY:JOB #:SCALE:DWG #:
DWG TITLE:
REV
DR
AWN
REV
ISIO
NS
CH
ECKE
DR
EVIE
WED
APPR
OVE
D
230KV GEN TIE
230KV GT-SD
1"=400' @11X17
ESC ENGINEERING INC.
PA
LM
ER
SO
LA
R6
5.0
0M
W A
C,
84
.94
MW
DC
EL P
AS
O C
OU
NT
Y,
CO
718-469
A
B
C
D
E
A
B
C
D
E
87654321
87654321
JUWI INC.1710 29TH ST. SUITE 1068BOULDER, CO 80301WWW.JUWIAMERICAS.COM
SITE DEVELOPMENTPLAN
11-FEB-2019
STRUCTURE HEIGHT = 88` AGL
STRUCTURE HEIGHT = 70` AGL
VERT. SCALE
HORIZ. SCALE40.0 FT.
400.0 FT. NORTH
SUBSTATION CONSTRUCTION STANDARDS
APPROVED AS OF:
OPERATIONS: ENGINEERING:DRAWING BY:
5-21-2013 PG.4-5 1/2
H. ENGLE S. CORNELL T. RICHTER
SUBSTATION FENCE SIGNAGE
FENCE SIGNAGEALTERNATING NO TRESPASSING AND WARNING SIGNS SPACED AT 25' (MAX.)
DRIVE -THROUGH GATE SIGNAGE(3) SIGNS FOR ALL DRIVE-IN GATES
MAN-GATE SIGNAGENO TRESPASSING AND WARNING SIGNS
MOUNTED ON THEFENCE FABRIC(OUTSIDE OFFIXED FENCE)
GATE OPENS
25'-0" MAX
14.00"TO TOPOF SIGN
14.00"TO TOPOF SIGN
14.00"TO TOPOF SIGN
14.00"TO TOPOF SIGN
SUBSTATION CONSTRUCTION STANDARDS
APPROVED AS OF:
OPERATIONS: ENGINEERING:DRAWING BY:
5-21-2013 PG.4-5 2/2
H. ENGLE S. CORNELL T. RICHTER
SUBSTATION FENCE SIGNAGE
NOTES:1. Signs for substation fences:
a. Three signs have been approved for substation fences.b. The first is an address sign that will have the substation name and both an address and GPS coordinates.c. The second sign will be a "No Trespassing" sign, in both English and Spanish (CSU item #193-000-001).d. The third sign will be a "Warning, Keep Out" sign, with the phone number to utilities dispatch (CSU item
#193-000-002).e. All signs shall meet ANSI Z535 requirements.
2. Fabric:a. Fence fabric shall have both no trespassing and warning signs posted on a alternating basis not to exceed 25'
between each sign. Example: No Trespassing signs should be spaced not to exceed 50' intervals. Warningsigns are to also meet this minimum spacing requirement.
b. All signs shall be centered between posts. The top of the signs shall be approximately 14" below the top of thewire support of the fabric.
c. Mounting of the signs shall be on all four corners, attached to fence fabric by the following method: 9 gauge,double strand steel wire, double wrapped to fence fabric or by another method.
3. Gates:Address signs will be mounted on the fence fabric- not the gate fabric. The address sign shall be located on theside in which the gate opens. The top of the address sign shall be approximately 14" below the top rail. The gatemust include a warning sign and no trespassing sign. These shall be mounted on the fence fabric of the gate. Thetop of these signs shall be approximately 14" below the top fence rail. All signs must be approved by andprovided by the site owner (Colorado Springs Utilities). Man-gates do not require an address sign, but shouldhave both a "No Trespassing" sign and a "Warning" sign, installed with the same requirements.
WARNING SIGNFOR GATES & FENCES
18" X 12"(ITEM #193-000-001)
NO TRESPASSING SIGNFOR GATES & FENCES
18" X 12"(ITEM #193-000-002)
SUBSTATION IDENTIFICATION SIGNFOR USE NEAR DRIVE-IN GATES
18" X 12"
7/16" HOLES DRILLEDON ALL FOUR CORNERS(ALL SIGN TYPES)