Top Banner
1 FEATURES SPST 5A TV-8 rating capability (120A inrush current) High density mounting Saves space by 26% compared to FTR-H1 type High insulation Insulation distance between coil and contacts: 6mm Dielectric Strength: 4KV Surge Strength: 12KV Flux proof type. RTII Flammability 94V-0 Cadmium free contact for eco-program Safety standards UL, CSA approved UL/CSA TV-8 rating approved RoHS Compliant Please see page 5 for more information Actual marking does not carry the type name : "FTR" E.g.: Ordering code: FTR-F2PM012T Actual marking: F2PM012T FTR-F2P Series POWER RELAY 1 POLE - 120A Inrush current PARTNUMBER INFORMATION FTR-F2P M 012 T [Example] (a) (b) (c) (d) (a) Relay type FTR-F2P : FTR-F2P-Series (b) Coil type / enclosure M : High sensitivity (250mW) and high isolation (c) Coil rated voltage 012 : 5.....24 VDC Coil rating table at page 3 (d) Contact material T : Silver tin oxide
6

Datasheet: FTR-F2P relay

Oct 16, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Datasheet: FTR-F2P relay

1

FTR-K1 SERIES

FEATURES SPST 5A TV-8 rating capability (120A inrush current) High density mounting

Saves space by 26% compared to FTR-H1 type High insulation

Insulation distance between coil and contacts: 6mmDielectric Strength: 4KVSurge Strength: 12KV

Flux proof type. RTII Flammability 94V-0 Cadmium free contact for eco-program Safety standards

UL, CSA approvedUL/CSA TV-8 rating approved

RoHS CompliantPlease see page 5 for more information

Actual marking does not carry the type name : "FTR"E.g.: Ordering code: FTR-F2PM012T Actual marking: F2PM012T

FTR-F2P Series

POWER RELAY1 POLE - 120A Inrush current

PARTNUMBER INFORMATIONFTR-F2P M 012 T

[Example] (a) (b) (c) (d)

(a) Relay type FTR-F2P : FTR-F2P-Series

(b) Coil type / enclosure M : High sensitivity (250mW) and high isolation

(c) Coil rated voltage 012 : 5.....24 VDC Coil rating table at page 3

(d) Contact material T : Silver tin oxide

Page 2: Datasheet: FTR-F2P relay

2

FTR-K1 SERIES

SPECIFICATION

Item Open type

F2 PM ( ) T

Contact Data 1 form A (SPST-NO)

Construction

Configuration

Single

Material Silver tin oxide (AgNi)

Resistance (Initial) Max. 100 mΩ at 6 VDC, 1 A

Rated current 5A

Rated switching voltage 250VAC, 30VDC

Max. ca

Max. inrush current

rrying current 5A

117A 250VACMax. switching voltage 400VAC / 300 VDC

Max. switching power 1,250VA / 150W

Min. switching load* 100 mA, 5 VDC

Life Mechanical Min. 2 x 106 operations

Electrical AC contact rating Min. 100 x 103 operations

DC contact rating Min. 100 x 103 operations

Lamp load (TV-8) Min. 25 x 103 operations

Coil Data Rated power 250mW

Operate power 160mW

Operating temperature range -40 °C to +70 °C (no frost)Timing Data Operate Max. 15ms (no diode, without bounce)

Release Max. 5ms (no diode, without bounce)

Insulation Resistance (Initial) Min. 1,000MΩ @500VDC

Dielectric strength Open contacts 1,000VAC (50/60Hz) 1min

Contacts to coil 4,000VAC (50/60Hz) 1min

Surge strength Coil to contacts 12,000V / 1.2 x 50µs standard wave

Clearance 6mm

Creepage 6mm

EN61810-1, VDE0435 Voltage 250V

Pollution degree 2

Material group III a

Other Vibration resistance Misoperation>1us 10 to 55 to 10Hz single amplitude 0.75mm

10 to 55 to 10Hz single amplitude 0.75mm Endurance

Shock Misoperation>1us Min. 200m/s2 (11+/-1ms)Endurance Min. 1,000m/s2 (6+/-1ms)

Weight Approximately 12g

Sealing Flux proof, RTII

load before production since reference values may vary according to switching frequencies, environmental conditionsand expected reliability levels.

* Minimum switching loads mentioned above are reference values. Please perform the confirmation test with actural

FTR-F2P SERIES

Page 3: Datasheet: FTR-F2P relay

3

FTR-K1 SERIES

COIL RATING

Coil Code

Rated Coil Voltage (VDC)

Coil Resistance +/- 10% (Ohm)

Must Operate Voltage

(VDC) *

Must Release Voltage

(VDC) *

Rated Power (mW)

005 5 100 3.5 0.25

250

006 6 145 4.2 0.3

009 9 325 6.3 0.45

012 12 575 8.4 0.6

018 18 1,245 12.6 0.9

024 24 2,310 16.8 1.2

Note: All values in the table are valid for 20°C and zero contact curren* Specified operate values are valid for pulse wave voltage.

Please use at rated coil voltage. Please refer to characteristic data and set up adequate voltage in case of use at over voltage.

t.

Type Compliance Contact rating

UL UL 508

E63614

Flammability: UL 94-V0 (plastics)

5A, 30 VDC/250VAC (resistive)1/6 HP, 125VAC1/2 HP, 250VACTV-8, 120 VACPilot duty: C300

CSA C22.2 No. 14LR 40304

SAFETY STANDARDS

FTR-F2 SERIESFTR-F2P SERIES

DIMENSIONS

Dimensions Schematics PC board mounting hole layout(BOTTOM VIEW) (BOTTOM VIEW)

)( 8.10.5φ

3.3

0.5

0.35

24.3 max.24.0 typ.

25.3

max

.25

.0 ty

p.

11.3 max.11.0 typ.

0.43.516.5 7.5

)( 57.1 1

1 2

34

Orientation mark

COM

NO

3.516.5)( 8.1

7.5

)(

57.1-2 9.0φ -2 3.1φ

* Dimensions of the terminals do not include thickness of pre-solder.* Dimensions do not include tolerances.* Tolerance of PC board mounting hole layout: ±0.1 unless otherwise speficied.

Unit: mm( ): Reference

Page 4: Datasheet: FTR-F2P relay

4

FTR-K1 SERIES

CHARACTERISTIC DATA

FTR-F2P SERIES

0 0.2 0.4 0.6 0.8 1.0 1.20

20

40

60

80

100

5A

0A

FTR-F2P

0 20 40 60 80 100

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

2.2

FTR-F2P

5A

0A

0perate voltage (hot coil)

0perate voltage (cool coil)

10 20 50 100 200 500 1000

0.2

0.5

1

2

5

10

20

50

100

FTR-F2P

DC resistive

MakeOperate

Release

AC resistive

1

DC30V L/R=7ms

AC250V cosφ=0.4DC30V L/R=15ms

100

50

20

10

5

2

1

AC250V cosφ=0.7

AC250V/DC30V resistive

FTR-F2PN=100FTR-F2PM012T

100

90

80

70

60

50

40

30

20

10

00 01 02 03 04 05 06 07 08 09 0010 1 2 3 4 5 6 7

N=100FTR-F2PM012T

100

80

60

40

20

00 2 4 6 8 01 21 41

Coil temperature rise

Life curve Distribution of operate/release voltage Distribution of contact resistance

Operating range Maximum switching power

Tem

pera

ture

rise

(°C)

Ambient temperature (°C) Contact voltage (V)

Contact resistance (mΩ)Nominal voltage multiplying factor (%)Contact current (A)

Serv

ice

life

(x 1

04 ope

ratio

ns)

Dis

trib

utio

n (%

)

Dis

trib

utio

n (%

)

Cont

act c

urre

nt (

A)

Nom

inal

vol

tage

mul

tiply

ing

fact

or

Coil power (W)

(Characteristic data is not guaranteed value but measured values of samples from production line.)

Page 5: Datasheet: FTR-F2P relay

5

FTR-K1 SERIESFTR-F2P SERIES

CAUTIONS

GENERAL INFORMATION1.. ROHS Compliance

delegated directive 2015/863.• All relays produced by Fujitsu Components are compliant with RoHS directive 2011/65/EU, including commission-

2. Recommended lead free solder condition•

Lead free solder plating on relay terminals is Sn-3.0Ag-0.5Cu, unless otherwise specified. This material has beenverified to be compatible with PbSn assembly process.Recommended solder for assembly: Sn-3.0Ag-0.5Cu.

3.. Moisture Sensitivity• Moisture Sensitivity Level standard is not applicable to electromechanical relays, unless otherwise indicated.

4.. Tin Whiskers• Dipped SnAgCu solder is known as presenting a low risk to tin whisker development. No considerable

length whisker was found by our in house test.

Flow Solder Condition:Pre-Heating:

Soldering:

maximum 120˚Cwithin 90 sec.dip within 5 sec. at 255°C±5°C solder bath

Relay must be cooled by air immediately after soldering

Solder by Soldering Iron:Soldering Iron: 30-60WTemperature:eDuration:

: maximu 340-360˚Cmaximum 3 sec.

We highly recommend that you confirm your actual solder conditions

・ All values mentioned in this datasheet are provided under ideal conditions. Please perform the confirmationtest before actual use.・ Reflow soldering is prohibited.・ Do not use relays in the atmosphere with sulfide gas, chloride gas or nitric oxide. Contact resistance ma

increase.・ Do not use silicon or silicon-containing product or materials near relays. It may cause contact failure.

Page 6: Datasheet: FTR-F2P relay

6

FTR-K1 SERIESFTR-F2P SERIES

Fujitsu Components International Headquarter Offices

JapanFUJITSU COMPONENT LIMITEDShinagawa Seaside Park Tower 20F,12-4, Higashi-shinagawa 4-chome, Shinagawa-ku,Tokyo,140-0002, JapanTel: (81-3) 3450-1682Email: [email protected]: www.fcl.fujitsu.com/

North and South AmericaFUJITSU COMPONENTS AMERICA, INC1230 E. Arques Ave. M/S 160Sunnyvale, CA. 94085, USATel: (1-408) 745-4900Fax: (1-408) 745-4970Email: [email protected]: us.fujitsu.com/components

EuropeFUJITSU COMPONENTS EUROPE B.V.Diamantlaan 252132 WV HoofddorpNetherlandsTel: (31-23) 5560910Fax: (31-23) 5560950Email: [email protected]: www.fujitsu.com/uk/components

Asia PacificFUJITSU COMPONENTS ASIA, LTD.102E Pasir Panjang Road#01-01 Citilink Warehouse ComplexSingapore 118529Tel: (65) 6375-8560Fax: (65) 6273-3021Email: [email protected]: www.fujitsu.com/sg/products/devices/components

ChinaFUJITSU ELECTRONIC COMPONENTS (SHANGHAI) CO., LTD.Unit 4306, B.M. InterContinental Center100 Yu Tong Road, Shanghai 200070, ChinaTel: (86-21) 3253 0998Fax: (86-21) 3253 0997Email: [email protected]: www.fujitsu.com/cn/products/devices/components/

Hong KongFUJITSU COMPONENTS HONG KONG CO., LTDUnit 2313, Seapower Tower, Concordia PlazaNo.1 Science Museum Road, Tsim Sha Tsui, Kowloon,Hong KongTel: (852) 2881-8495Tex: (852) 2894-9512Email: [email protected]: www.fujitsu.com/sg/products/devices/components/

KoreaFUJITSU COMPONENTS KOREA LIMITED#403, 180, Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13524 Korea Tel: (82) 31-708-7108Fax: (82) 31-709-7108Email: [email protected]/sg/products/devices/components/

c 2021 Fujitsu Components Europe B.V. All rights reserved. All trademarks or registered trademarks are the property of their respective owners.

Fujitsu Products are intended for general use, including without limitation, in personal, household and office environments, in buildings and for ordinary usein the industry. Fujitsu Products are not intended to be used in applications where extremely high safety is required ("High Safety Required Applications"), such as, but not limited to, applications in nuclear facilities, in aircraft automatic flight control, in air traffic control, in mass transit system control, in missile launch systems, in weapon systems, in medical equipment for life support or any application involving a direct serious risk of physical injury or death.Please do not use Fujitsu Products without securing the sufficient safety and reliability required for the High Safety Required Applications.In addition, Fujitsu shall not be liable against the customer and/or any third party for any claims or damages arising in connection with the use of Fujitsu Products in the High Safety Required Applications.Fujitsu warrants that its Products, if properly used and serviced, will conform to their specification and will be free from defects in material and workmanship for twelve months from delivery.The implied warranties of merchantability and fitness for a particular purpose and all other warranties, representations and conditions, express or implied by statute, trade usage or otherwise, except as set forth in this warranty, are excluded and shall not apply to the Products delivered.

The contents, data and information in this datasheet are provided by Fujitsu Component Ltd. as a service only to its user and only for general information purposes. The use of the contents, data and information provided in this datasheet is at the users’ own risk.Fujitsu has assembled this datasheet with care and will endeavor to keep the contents, data and information correct, accurate, comprehensive,complete and up to date.Fujitsu Components Europe B.V. and affiliated companies do however not accept any responsibility or liability on their behalf, nor on behalf of its employees, for any loss or damage, direct, indirect or consequential, with respect to this datasheet, its contents, data, and information and related graphics and the correctness, reliability, accuracy, comprehensiveness, usefulness, availability and completeness thereof.Nor do Fujitsu Components Europe B.V. and affiliated companies accept on their behalf, nor on behalf of its employees, any responsibility or liability with respect to these datasheets, its contents, data, information and related graphics and the correctness, reliability, accuracy, comprehensiveness, usefulness, availability and completeness thereof. Rev. August 25, 2021