Top Banner
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright © 2019 Eaton 457 9L 9L Light-Pak N2LPS LED emergency lighting system Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Cl. II, Div. 2, Groups F, G (N2LPS only) Marine & Wet Locations NEMA 4, 4X Applications: Light-Pak N2LPS LED emergency lighting systems are used: To provide reliable illumination for egress areas during failure or interruption of power to the normal lighting system In areas where flammable gases or vapors may become present due to abnormal, unusual or accidental conditions In manufacturing plants, refineries, petrochemical and chemical plants, waste and sewage treatment facilities, oil terminals, food processing facilities, breweries and other industrial manufacturing or process industry facilities subject to wet or corrosive conditions To illuminate machinery or panels during a loss of AC power Where moisture, dirt, dust or corrosion will limit the life and reliability of ordinary emergency lighting systems Where required by the National Electrical Code ® , the Life Safety Code ® or other applicable codes Outdoor applications Features: Non-metallic, enclosed, gasketed housing – provides corrosion protection in the most extreme environments Durable and marine rated LED lamp head assemblies – provide protection against water ingress, corrosion and impact Nickel cadmium battery – high temperature rated nickel cadmium battery for reliable operation up to 55°C ambient Reduced maintenance costs – self-test, monitoring and diagnostics reduce costly maintenance checks Remote mountable lamp heads – lamp heads can be mounted independently from the enclosure, allowing you to focus light where you need it Solid state battery charger – ensures long life and reliable battery operation; prevents deep discharge by automatically disconnecting the battery from the luminaire N2RF includes 3 / 4” hub Standard materials: Power supply and remote luminaire enclosure – Krydon fiberglass-reinforced polyester LED lamp head assembly – epoxy powder coated aluminum Exterior hardware – nylon, plastic coated, and stainless steel Cover gasket – Hypalon synthetic rubber Certifications and compliances: NEC/CEC: Class I, Division 2, Groups B, C, D Class I, Zone 2 Class II, Division 2, Groups F, G (N2LPS only) NEMA 4, 4X Marine and wet locations suitability UL standards: UL1598A – Supplemental Requirements for Luminaires for Installation on Marine Vessels UL924 – Emergency Lighting and Power Equipment UL844 – Electric Luminaires Hazardous Locations CSA standards: C22.2 No. 141-M1985 C22.2 No. 137-M1981 NFPA: Life Safety Code NFPA101 – Section 5-9 (Emergency Lighting) Electrical ratings: Power supply: Input – 120-277 VAC, 50 or 60 Hz; 6W maximum Output – 12 VDC LED luminaire heads: Voltage – 12 VDC Lamp – 1W LED, 6W maximum Maximum 6 lamp heads Photometrics: Complete photometrics can be found at www.crouse-hinds.com/photometrics Options: Description Suffix • Breather/drain .................................... S931 External battery disconnect switch ... S932 Ordering information: Description Cat. # 28W, 12V power supply, two 1W LED lamp heads N2LPSM212222 28W, 12V power supply, less luminaire heads N2LPSM212220 Remote luminaire assembly, one LED lamp head N2RFM21221 Remote luminaire assembly, two LED lamp heads N2RFM21222 6W, 12V power supply with exit sign (single sided) N2LPSM212222 UX71SDHAZA 6W, 12V power supply with exit sign (double sided) N2LPSM212222 UX72SDHAZA Temperature performance data: Cat. # Class I & II, Division 2 N2LPS (all models) T6 N2RF (all models) AClass I, Division 2 only. Note:  Ambient temperature at which the Light-Pak system is rated is -20°C to 55°C. Operation at temperatures outside this range will affect the battery life and/or charging performance.
2

Crouse-Hinds series Light-Pak N2LPS LED Emergency …...emergency lighting system Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Cl. II, Div. 2, Groups F, G (N2LPS only) Marine & Wet

May 23, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Crouse-Hinds series Light-Pak N2LPS LED Emergency …...emergency lighting system Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Cl. II, Div. 2, Groups F, G (N2LPS only) Marine & Wet

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2019 Eaton 457

9L9L

Light-Pak N2LPS LEDemergency lighting system

Cl. I, Div. 2, Groups B, C, DCl. I, Zone 2Cl. II, Div. 2, Groups F, G (N2LPS only)Marine & Wet LocationsNEMA 4, 4X

Applications:Light-Pak™ N2LPS LED emergency lighting systems are used:• To provide reliable illumination for egress

areas during failure or interruption ofpower to the normal lighting system

• In areas where flammable gases or vaporsmay become present due to abnormal,unusual or accidental conditions

• In manufacturing plants, refineries,petrochemical and chemical plants,waste and sewage treatment facilities,oil terminals, food processing facilities,breweries and other industrialmanufacturing or process industry facilitiessubject to wet or corrosive conditions

• To illuminate machinery or panels during aloss of AC power

• Where moisture, dirt, dust or corrosionwill limit the life and reliability of ordinaryemergency lighting systems

• Where required by the National ElectricalCode®, the Life Safety Code® or otherapplicable codes

• Outdoor applications

Features:• Non-metallic, enclosed, gasketed housing

– provides corrosion protection in themost extreme environments

• Durable and marine rated LED lamp headassemblies – provide protection againstwater ingress, corrosion and impact

• Nickel cadmium battery – hightemperature rated nickel cadmium batteryfor reliable operation up to 55°C ambient

• Reduced maintenance costs – self-test,monitoring and diagnostics reduce costlymaintenance checks

• Remote mountable lamp heads – lampheads can be mounted independentlyfrom the enclosure, allowing you to focuslight where you need it

• Solid state battery charger – ensureslong life and reliable battery operation;prevents deep discharge by automaticallydisconnecting the battery from theluminaire

• N2RF includes 3/4” hub

Standard materials:• Power supply and remote luminaire

enclosure – Krydon fiberglass-reinforcedpolyester

• LED lamp head assembly – epoxy powdercoated aluminum

• Exterior hardware – nylon, plastic coated,and stainless steel

• Cover gasket – Hypalon synthetic rubber

Certifications and compliances:NEC/CEC:• Class I, Division 2, Groups B, C, D• Class I, Zone 2• Class II, Division 2, Groups F, G (N2LPS

only)• NEMA 4, 4X• Marine and wet locations suitabilityUL standards:• UL1598A – Supplemental Requirements

for Luminaires for Installation on MarineVessels

• UL924 – Emergency Lighting and PowerEquipment

• UL844 – Electric Luminaires HazardousLocations

CSA standards:• C22.2 No. 141-M1985• C22.2 No. 137-M1981NFPA:• Life Safety Code NFPA101 – Section 5-9

(Emergency Lighting)

Electrical ratings:• Power supply:

Input – 120-277 VAC, 50 or 60 Hz; 6WmaximumOutput – 12 VDC

• LED luminaire heads:Voltage – 12 VDCLamp – 1W LED, 6W maximumMaximum 6 lamp heads

Photometrics:• Complete photometrics can be found at

www.crouse-hinds.com/photometrics

Options:Description Suffix• Breather/drain .................................... S931• External battery disconnect switch ... S932

Ordering information:Description Cat. #

28W, 12V power supply, two 1W LED lamp heads N2LPSM21222228W, 12V power supply, less luminaire heads N2LPSM212220Remote luminaire assembly, one LED lamp head N2RFM21221Remote luminaire assembly, two LED lamp heads N2RFM212226W, 12V power supply with exit sign (single sided) N2LPSM212222 UX71SDHAZA

6W, 12V power supply with exit sign (double sided) N2LPSM212222 UX72SDHAZA

Temperature performance data:Cat. #

Class I & II, Division 2

N2LPS (all models) T6N2RF (all models)

AClass I, Division 2 only.

Note:   Ambient temperature at which the Light-Pak system is rated is -20°C to 55°C. Operation at temperatures outside this range will affect the battery life and/or charging performance.

Page 2: Crouse-Hinds series Light-Pak N2LPS LED Emergency …...emergency lighting system Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Cl. II, Div. 2, Groups F, G (N2LPS only) Marine & Wet

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2019 Eaton458

9L9L

Dimensions (in inches):

Light-Pak N2LPS LEDemergency lighting system

Cl. I, Div. 2, Groups B, C, DCl. I, Zone 2Cl. II, Div. 2, Groups F, G (N2LPS only)Marine & Wet LocationsNEMA 4, 4X

Weights:Cat. # Weight (lbs.) Weight (kg.)

N2LPSM212222 12.00 7.26N2LPSM212220 10.00 5.44N2RFM21221 7.00 3.63N2RFM21222 8.00 4.08

12.40

14.91

25.63

UX71SDHAZ option – single sided

UX72SDHAZ option – double sided

Status indication Status description Status definition

No light AC power removed from circuit* Steady light (no blinks) Fully charged or test in process* - * Light blinks once Battery charging**-** Light blinks twice Battery failure***-*** Light blinks three times Circuit failure****-**** Light blinks four times Lamp failure

Detail indication logic: