Top Banner
Bioloid Premium Kit Battle Droid Assembly Manual 1 Bioloid Premium Kit Battle Droid Assembly Manual v1.1
10

Bioloid Premium Kit Battle Droid Assembly Manual · Bioloid. Premium Kit. Battle Droid. Assembly Manual. 1. Bioloid Premium Kit Battle Droid Assembly Manual v1.1

Aug 15, 2018

Download

Documents

doduong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Bioloid Premium Kit Battle Droid Assembly Manual · Bioloid. Premium Kit. Battle Droid. Assembly Manual. 1. Bioloid Premium Kit Battle Droid Assembly Manual v1.1

Bioloid

Premium Kit

Battle Droid

Assembly Manual

1

Bioloid Premium Kit Battle Droid Assembly Manual v1.1

Page 2: Bioloid Premium Kit Battle Droid Assembly Manual · Bioloid. Premium Kit. Battle Droid. Assembly Manual. 1. Bioloid Premium Kit Battle Droid Assembly Manual v1.1

2

Attention!Before proceeding with assembly you must ensure each actuator’s horn is properly aligned. To visually verify proper alignment, the notch from the horn should be in line with the notch from the actuator’s body.If not, perform one of the following actions:A.Turn the horn manually until its properly aligned.B.Use Dyna mixel Wizard.

1. Start RoboPlus and run Dynamixel Wizard.2. Connect the actuator to the computer through USB2Dynamixel. Don’t forget to supply power to the actuator

separately.3 . Select the correct port, click on the Open Port icon, and click on Start Search.4. On address 30, Goal Position, click on Center Position. Dynamixel Wizard will then align the horn; you

can visually verify horn alignment afterwards.

(For more information, please refer to Dynamixel Management.)

I. Always assign ID numbers to the actuators before assembly. Robotis recommends you assign ID’s by one actuator at a time.

II. You may need apply gentle pressure to fit nuts into the actuator’s body. The tight fit is necessary to facilitate assembly.

A. Insert only one nut at a time.B . Use your screwdriver to apply pressure on the nut.C . Point the screwdriver away from your body and away from other people.

Dynamixel Wizard properly aligned horn

*Some robots may require a specific horn alignment before assembly.Please follow assembly instructions closely if such horn alignment is necessary.

Tips!

Page 3: Bioloid Premium Kit Battle Droid Assembly Manual · Bioloid. Premium Kit. Battle Droid. Assembly Manual. 1. Bioloid Premium Kit Battle Droid Assembly Manual v1.1

Attach one F3 to ID1. Connect one F3 to ID2.(Do not misalign horn position.)

Attach one F1 to one F12.(Attention to left and right direction.)

Attach ID3 and ID4 to STEP①and STEP②. (Do not misalign horn position.)Attach ID1 to ID3 through F3. Attach ID2 to ID4 through F3.

F3 x 2 S1 x 8

S1

N1 x 16

N1

F3

F1 x 2 F12 x 2 S1 x 8 N

1x 8

Right Left

N

1

S1F1

2

F1

BU x 2 WA x 2 S

1x 16 S-B x 2

S1

W

A

BU

S-B

S1

N

1x 8

N

1

3

1 2

1 2

1 2

3 4 5

F3

F1

2

F1

2

F1

Bioloid Battle Droid – Getting Started

Page 4: Bioloid Premium Kit Battle Droid Assembly Manual · Bioloid. Premium Kit. Battle Droid. Assembly Manual. 1. Bioloid Premium Kit Battle Droid Assembly Manual v1.1

4

Connect one F8 to each leg of STEP③.Connect ID1 and ID3; ID2 and ID4 with CABLE-14.Connect ID1 and ID with CABLE-14.

Attach one F1 (at the horn), one F3, two F55 to ID5.Attach one F1 (at the horn), one F3, two F55 to ID6.

F1 x 2 N

1x 32S1 x 24F55 x 8F3 x 4

N

1

F3

F55

F1S1

S

1

Right

S

1

Left

1 2 3

54

S1 x 8 N

1x 2

U

pdow

n

N

1

U

p

down

S

1

S1

U

p

N1

F8 x 2

F8

CABLE-14

CABLE-14 x 4

dow

n

U

p

1 2 3

4

F8

F8

F3

F1

F3

Page 5: Bioloid Premium Kit Battle Droid Assembly Manual · Bioloid. Premium Kit. Battle Droid. Assembly Manual. 1. Bioloid Premium Kit Battle Droid Assembly Manual v1.1

5

Attach one F3 and one F10 to each F4.

Attach each part from STEP⑤(do not misalign horn position) and STEP⑥to ID7.Attach each part from STEP⑤(do not misalign horn position) and STEP⑥to ID8.

Attach both parts of STEP⑦to F51.

F3 x 2 N1 x 8S5 x 8F10 x 4F4 x 2

F3

F10

S5

F4

S1 x 8

S1

dow

n

F51U

p

F51 x 1

1 2

1 2

N

1x 8S

1x 16BU x 2 WA x 2

N1

B

U

WA

S-B

S1

WA

BU

S-B

S1

1 2 3

S-B x 2

F4

F10 x 2

F3

F51

Page 6: Bioloid Premium Kit Battle Droid Assembly Manual · Bioloid. Premium Kit. Battle Droid. Assembly Manual. 1. Bioloid Premium Kit Battle Droid Assembly Manual v1.1

6

Attach one F5, One F9, one F10 and one F54 to STEP⑧.

Attach one F54 and one F60 to STEP⑨.

S2 x 4F5 x 1 F10 x 1 S5 x 2F9 x 1

S2

N1

S2

F5

F9

S5

F54

F10

N1

N1 x 6

S2

F54 x 1

N

1x 2S2 x 2F60 x 1 F54 x 1

N1

F54

F60

S2N

1

1 2 3

1-

1

1 2

F9

F5

F5

F10

F54

F60

F54

Page 7: Bioloid Premium Kit Battle Droid Assembly Manual · Bioloid. Premium Kit. Battle Droid. Assembly Manual. 1. Bioloid Premium Kit Battle Droid Assembly Manual v1.1

7

Attach STEP④and ⑩.Connect ID1 and ID5 with CABLE-14.Connect ID2 and ID6 with CABLE-14.Connect ID5 and ID6 with CABLE-10.

Attach an F52, an IR SENSOR, a SINGLE BRACKET, and a PLATE 3x7, to CM-510.Connect IR SENSOR to CM-510 with 5P CABLE-15 (through Port 1 of CM-510).

S2 x 2

S

2

CABLE-10

CABLE-10

CABLE-10 x 2

1 2

3

PLATE 3x7

RIVE

T

SINGLE

BRACKET

IR SENSOR

5P CABLE-15

F5

2

S1

S

1

PORT 1 ( | )

5P CABLE

RIVE

T

S1 x 12 5P CABLE-15 x 1 IR SENSOR x 1 RIVET x 8

SINGLE BRACKET x 2 PLATE 3x7 x 1 F52 x 1

CABLE-

BAT

CABLE-BAT x 1

CABLE-

BAT

CM-510 x 1

1 2

3

3-

1

F5

2

CM-510

Page 8: Bioloid Premium Kit Battle Droid Assembly Manual · Bioloid. Premium Kit. Battle Droid. Assembly Manual. 1. Bioloid Premium Kit Battle Droid Assembly Manual v1.1

8

Connect ID7 to CM-510 with CABLE-18.Connect ID8 to CM-510 with CABLE-18.Connect the battery to CM-510 with the battery cable.

CABLE-18

BATTERY x 1

BATTERY

CABLE-18 x 2

12

3

Page 9: Bioloid Premium Kit Battle Droid Assembly Manual · Bioloid. Premium Kit. Battle Droid. Assembly Manual. 1. Bioloid Premium Kit Battle Droid Assembly Manual v1.1

9

Assembly CheckAfter assembly please check the following procedure to ensure correctness.

Run the assembly check programSet the robot in PLAY mode; hold the D button then press START.Once the START button is pressed, the assembly check program begins.

AX12+ initial position and ID checkSelect each actuator separately and compare it to the picture below.Ensure the actuators’ horns are properly aligned (the horn’s notch should be aligned with the actuator’s). Pressing the U or D button selects one actuator at a time. The selected actuator’s LED lights up and goes to its initial position.Check starts from ID1. U moves to the next ID in ascending numerical order; D, in descending numerical order. If the actuator’s ID does not exist then the robot beeps.Although the LED may lit, if there is no power then check the wiring on the actuator.

Page 10: Bioloid Premium Kit Battle Droid Assembly Manual · Bioloid. Premium Kit. Battle Droid. Assembly Manual. 1. Bioloid Premium Kit Battle Droid Assembly Manual v1.1

10

Sensor and behavior checkFrom STEP② press R. The robot returns to its initial position as pictured above.Place your hand close to the sensors as pictured below. Robot behavior begins.If the robot does not behave, as pictured below, then check the sensor wiring and its port.Pressing L will return the robot back to STEP②.

If everything works fine, play the robot.Set the robot in PLAY mode and press START. The robot will play.