Top Banner
An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014
15

An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

Jan 03, 2016

Download

Documents

Madlyn Payne
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

An Example of Residential

Solar RetrofitShawn Fitzpatrick, P.E.

Energy EngineerAdvanced Energy

September 30, 2014

Page 2: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

House Before Solar Retrofit

Page 3: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

House Description Before Retrofit

• 900 sq.ft. conditioned space, 2 bedroom, 1 bath

• Built in 1949• No floor or wall insulation and poor

R11 ceiling insulation• Single pane windows• Gas heat, Electric AC• Electric tank type water heater• Electric cloths dryer

Page 4: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

House After Solar Addition and Renovation

Page 5: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

How Bad will PV Shading Be?

Page 6: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

The Solar Pathfinder• Hemispherical reflection on dome is

traced on sun chart with grease pencil• Similar new devices are electronic with

digital camera

Page 7: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

Solar Pathfinder Shadow Trace

• One trace gives information for every month and hour in the year

• Add up unshaded percentages for each month

• This gives the percentage of solar availability for each month

Page 8: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

Solmetric SunEye - Digital Shade Analyzer

Page 9: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

Calculation of Shade Factor from Pathfinder

MonthSun Chart % Solar

AvailabilityAvg. Sunhours/Day

(kWh/m2-day)Available Sun Hours

(kWh/m2-day)

Jan 56.0% 3.8 2.13

Feb 61.0% 4.5 2.75

Mar 68.0% 5.2 3.54

Apr 73.0% 5.7 4.16

May 97.0% 5.7 5.53

Jun 95.5% 5.7 5.44

Jul 97.0% 5.6 5.43

Aug 78.5% 5.5 4.32

Sep 70.5% 5.2 3.67

Oct 63.0% 4.9 3.09

Nov 57.0% 4.1 2.34

Dec 51.0% 3.6 1.84

Average   5.0 3.68

    Shade Factor 0.74

Page 10: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.
Page 11: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

How Is the PV Doing?

• PV modules are now 21 years old. They were originally installed on a Duke Energy project in Charlotte, NC in 1993.

• I installed my second-hand PV in February 2006 (~ 8 yrs. ago)

• The average annual solar production for recent 6 years was 2067 kWh/yr.

• Based on PV Watts software, PV was expected to produce 2290 kWh of electricity per year

• PV production over last 6 years is within 10% of expected

Page 12: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

PV Generation and House Usage

2007 2008 2009 2010 2011 20120

500

1000

1500

2000

2500

3000

3500

4000

4500

2406

2918 2988

39083718

3583

House kWh Usage Solar PV kWh Generation

Ele

ctri

cal En

erg

y (

kW

h)

Page 13: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

How Is the PV Doing?

• PV generation has remained almost constant over 6 years (varied with weather)

• House consumption has increased somewhat during this time but leveled out the last few years

• 2007 PV generation equaled 87% of house consumption

• 2012 PV generation equaled 56% of house consumption

Page 14: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

2012 Monthly Solar Generation and House Usage

Jan-

12

Feb-

12

Mar

-12

Apr-1

2

May

-12

Jun-

12

Jul-1

2

Aug-

12

Sep-

12

Oct-1

2

Nov-1

2

Dec-1

20

100

200

300

400

500

600

700

House kWh Usage Solar PV kWh Generation

Ele

ctri

cal En

erg

y (

kW

h)

Page 15: An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.

Shawn Fitzpatrick, P.E.Energy EngineerAdvanced Energy

919 [email protected]