University of Southern Maine Addendum #1 High Fidelity Nursing Simulation Lab 10 February 2020 Project No. 31905 Page 1 of 4 2019-015 High Fidelity Nursing Simulation Lab at Science Building – C Wing University of Southern Maine, Portland Campus Portland, Maine Addendum #1 The attention of Contractors submitting bids for the subject property at the University of Southern Maine Portland Campus is called to the following addendum to the Request for Bids. The items set forth herein are to be included in and form a part of the bid proposal submitted. Note: The number of this addendum (1) and its date must be acknowledged on the bid form. LIST OF BIDDERS PRESENT AT WALKTHROUGH : Sign-in sheet for bidders present at the pre-bid walkthrough is attached at the end of this addendum. DRAWING CHANGES : The following drawings have been revised for Addendum 1: A9.2 – Door and Partition Types A10.0 – Typical Laboratory Details A10.2 – Detailed Simulation Plans and Elevations Revisions are clouded and noted with a triangle indicating the revision number. Drawings are attached at the end of this addendum. ANSWERS TO BIDDERS QUESTIONS : 1. Q - Drwg A9.2, The Doors & Partition Types Details show wood doors but the Door Schedule show all doors as AL (aluminum). With no wood door spec I assume all doors are to be aluminum.....correct? A - Yes all doors are aluminum with the exception of door 401A which is hollow metal. 2. Q - The two F-8 windows are detailed on the frame details, drawings A9.2… and detailed again on Drawing A10.0, Detail 1, as hollow-metal. A- The F8 windows detailed on A10.0 are correct, those two windows in the control room should be hollow metal so that we can angle the glass in the frame. The detail sections identified on A9.2 are incorrect.
9
Embed
Addendum #1 - Blane Casey...University of Southern Maine Addendum #1 High Fidelity Nursing Simulation Lab 10 February 2020 Project No. 31905 Page 2 of 4 3. Q - Based on detail 1, the
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
University of Southern Maine Addendum #1 High Fidelity Nursing Simulation Lab 10 February 2020 Project No. 31905
Page 1 of 4
2019-015 High Fidelity Nursing Simulation Lab
at
Science Building – C Wing
University of Southern Maine, Portland Campus Portland, Maine
Addendum #1
The attention of Contractors submitting bids for the subject property at the University of Southern Maine Portland Campus is called to the following addendum to the Request for Bids. The items set forth herein are to be included in and form a part of the bid proposal submitted.
Note: The number of this addendum (1) and its date must be acknowledged on the bid form.
LIST OF BIDDERS PRESENT AT WALKTHROUGH:
Sign-in sheet for bidders present at the pre-bid walkthrough is attached at the end of this addendum.
DRAWING CHANGES:
The following drawings have been revised for Addendum 1:
A9.2 – Door and Partition Types A10.0 – Typical Laboratory Details A10.2 – Detailed Simulation Plans and Elevations
Revisions are clouded and noted with a triangle indicating the revision number. Drawings are attached at the end of this addendum.
ANSWERS TO BIDDERS QUESTIONS:
1. Q - Drwg A9.2, The Doors & Partition Types Details show wood doors but the Door Scheduleshow all doors as AL (aluminum). With no wood door spec I assume all doors are to be aluminum.....correct?
A - Yes all doors are aluminum with the exception of door 401A which is hollow metal.
2. Q - The two F-8 windows are detailed on the frame details, drawings A9.2… and detailed againon Drawing A10.0, Detail 1, as hollow-metal.
A- The F8 windows detailed on A10.0 are correct, those two windows in the control room should be hollow metal so that we can angle the glass in the frame. The detail sections identified on A9.2 are incorrect.
University of Southern Maine Addendum #1 High Fidelity Nursing Simulation Lab 10 February 2020 Project No. 31905
Page 2 of 4
3. Q - Based on detail 1, the wall is a whole bunch thicker than 4 7/7” which is what the wallthickness needs to be for Wilson Partition 487 which is for 4 7/8” thick walls.
A - The wall in detail 1 on A10.0 is 4 7/8". F-8 frame should be hollow metal not Wilson’s aluminum partition.
4. Q - The pair of doors (door #401A) over the two electrical panels are supposed to be painted andblend with the wall to disappear. Currently the door schedule has these as aluminum with aluminum framing.
A – Door 401A should be hollow metal with a hollow metal frame, painted.
5. Q - Door #403, I have the same questions about this entry… how do I make stile and railaluminum door appear to be solid doors, Install smooth, double-faced aluminum panels in lieu of glass? The Architect doesn’t account for this?
A - Correct – install a smooth double-faced aluminum panel in place of the glass.
6. Q - The web address provided in Section 117200 – Medical Headwall Systems does not work.www.wittrockhc.com
A - Witt Rock has gone out of business. Substitute Amico Majestic Series single tier surface mounted headwall as basis-of-design. All specified requirements remain the same.
Q - The control contractor is listed in the spec. Will there be an allowance for this work or will each contractor be required to get a number from I.B.C. They might give out different numbers to different people.
A – No allowance provided for in this project.
7. Q - Any chance that the University can get the permitting process with the City of Portlandstarted?
A - The permitting process is already underway.
8. Q - The specified Carpet is only available in broadloom according to Mohawks website.Please advise.
A – For Basis of design, use Mohawk Power Surge Collection, Wavelength 955 Flow in tile format.
9. Q - Both Forbo and Armstrong are listed as basis of design products in the resilientdivision 9. We are instructed to carry 13” x 13” material (forbo sizes) however the color numbers listed for RT-1 and RT-2 correspond with Armstrong 12” x 24” striations.
University of Southern Maine Addendum #1 High Fidelity Nursing Simulation Lab 10 February 2020 Project No. 31905
Page 3 of 4
A - Basis of design for the resilient flooring to be Armstrong Striations BBT with Diamond 10 Technology Coating Bio-Flooring. Size: 12” x 24”. Colors as noted in the specification.
10. Q - Could you please direct me to where I can find the specifications on the “Large ScaleWall Graphic” which is shown on A10.7 Detail 2.
A – Graphic wallpaper has been eliminated from the project.
11. Q - Is there a specific start date?
A - As soon as possible.
13. Q - Access, laydown space, dumpster location?
A – A laydown area will be provided adjacent to the Science Building.
14. Q - Will Permit application process begin before GC award?
A - Permit process is underway
15. Q - Will classroom next door be active?
A - Yes, surrounding spaces will remain active and noise will need to be considered.
16. Q - Restriction on working hours / off hours work?
A – Normal working hours are expected between 7:30 and 4:00. Work outside normal workinghours can be requested and will be considered on an as needed basis.
17. Q - Is the thickness of the slab shown on the drawings?
A – The existing building drawings appear to show the slab thickness as 5" - V.I.F.
18. Q - Any existing VAV's?
A – No existing VAV’s.
19. Q - Is AV a separate scope?
A - AV is separate and RFP is still out. AV drawings are for reference only.
20. Q - Is there a spec on the graphic wallpaper?
A – Graphic wallpaper has been eliminated from the project.
21. Q - Construction budget?
A - $1.5M including the AV scope and manikins.
22. Q – Can you get any more detail on the Phenolic panels, such as color and thickness?
A – Basis of design is Trespa 3/16” thick, color “Steel Blue” Satin finish.
University of Southern Maine Addendum #1 High Fidelity Nursing Simulation Lab 10 February 2020 Project No. 31905
Page 4 of 4
23. Q – Can I get more details on the solid surface window sills. I would need some dimensions, Icannot tell from the floor plans how deep this is. Also a color for that would be important.
A – The sill in elevation 4 on A10.6 is approximately 2’ deep. The sills in de-brief room 2 and the office are approximately 5” deep and the sill in Sim room 1 are approximately 6” deep. Basis of design for all sills are 1” thick Corian, color “Deep Cloud”.
End of Addendum 1
24. Q - Upon review of the draft contracts provided, it appears both a modified A101 document and Special Conditions for A133 were included with the modified A201. It is our understanding that only one document (either A101 or A133) can accompany the A201 document. Please provide clarification if the A101 or the A133 document will accompany the A201 document provided.
A - Section 00 73 00.03 is to be deleted.
2
1 5 2 5 12
9
10
99
4 3 10 10
6
3 3
65
3
2
9
10
2
44 4
10
4 4
8
9
4
255
2
A10
.0
1
DO NOT SCREW GWB TO HEAD TRACK TO ALLOW FOR DEFLECTION
METAL STUDS
DEFLECTION TRACK
1 LAYER 5/8" GWB EACH SIDE
3/8" SEALANT CONTINUOUS AT TOP AND
BOTTOM (TYP)
4 7/8"
5 1/4"
7 1/4" 03A02A01A
01A
02A
03A
3 5/8" STUDS W/ 1 LAYER TYPE GWB ONEACH SIDE
4" STUDS W/ 1 LAYER TYPE GWB ONEACH SIDE
6" STUDS W/ 1 LAYER TYPE GWB ONEACH SIDE
STC ≈ 40STC ≈ 49 W/ SAFB
1 LAYER 5/8" GWB
3/8" SEALANT CONTINUOUS AT TOP AND
BOTTOM (TYP)
SUBSTRATE
METAL STUD
2 1/4"
3 1/8"
4 1/4" 2423
4 5/8" 25
23
24
25
2 1/2" STUDS W/ 1 LAYER GWB
3 5/8" STUDS W/ 1 LAYER GWB
4" STUDS W/ 1 LAYER GWB
22 1 5/8" STUDS W/ 1 LAYER GWB
22
WALL TYPE SUFFIX DESIGNATIONS:
.1 ABUSE RESISTANT GWB ON ONE SIDE
.2 ABUSE RESISTANT GWB ON EACH SIDE
.3 MOISTURE / MOLD RESISTANT GWB ON ONE SIDE
.4 MOISTURE / MOLD RESISTANT ON EACH SIDE
.5 VENEER PLASTER OVER GYPSUM BASE ON ONE SIDE
.6 VENEER PLASTER OVER GYPSUM BASE ON EACH SIDE
'S' PROVIDE 3" SOUND ATTENUATION FIRE BLANKET (SAFB) INSULATION
EXAMPLE
02C.5S
2 HOUR RATED PARTITION WITH 4" STUDS. 2 LAYERS OF TYPE X GWB ON EACH SIDE WITH VENEER PLASTER OVER GYPSUM BASE ON ONE SIDE. INCLUDE 3" SOUND ATTENUATION FIRE BLANKET INSULATION WITHIN THE STUD CAVITY.
WALL TYPE SUFFIX DESIGNATIONS
ALUMINUM STRIKE JAMB W/ SIDELIGHT6
3ALUMINUM DOOR HEADER
Scale: 3"=1'-0"
5ALUMINUM HINGE JAMB
Scale: 3"=1'-0"1
ALUMINUM STRIKE JAMB
Scale: 3"=1'-0"9
ALUMINUM SILL (FULL HEIGHT)
Scale: 3"=1'-0"
10ALUMINUM HORIZONTAL MUNTIN
Scale: 3"=1'-0"2
ALUMINUM JAMB MULLION
Scale: 3"=1'-0"
4ALUMINUM GLAZING HEADER
Scale: 3"=1'-0"
7ALUMINUM HEADER AT GLASS TRANSOM
Scale: 3"=1'-0"
PARTITION AS SCHEDULED
1 1/2"
ALUM JAMB
ALUM SNAP-ON TRIM
SAFETY GLASS
ALUM JAMB
ALUM SNAP-ON TRIM
ALUMINUM DOOR
1 1/2"
EXTENDED LIP STRIKE PLATE
DOOR SEAL
DOUBLE STUD
ALUM SNAP-ON TRIM
ALUMINUM DOOR
1 1/2"
DOOR HINGE
DOOR SEAL
SAFETY GLASSALUM JAMB
ALUM SNAP-ON TRIM
AULMINUM DOOR
1 1/2"
EXTENDED LIP STRIKE PLATE
DOOR SEAL
PARTITION AS SCHEDULED
ALUMINUM HEADER
ALUM SNAP-ON TRIM
ALUMINUM DOOR
DOOR SEAL
DOUBLE STUD
1 5/8" COLD ROLLED CHANNEL TO EXTEND TO ONE STUD BEYOND R.O.
ALUMINUM HEADER
ALUM SNAP-ON TRIM
ALUMINUM DOOR
DOOR SEAL
SAFETY GLASS
1 1/
2"
1 1/
2"
PARTITION AS SCHEDULED
ALUMINUM HEADER
ALUM SNAP-ON TRIM
SAFETY GLASS
DOUBLE STUD
ALUMINUM MUNTIN
ALUM SNAP-ON TRIM
SAFETY GLASS
SAFETY GLASS
ALUMINUM SILL
ALUM SNAP-ON TRIM
SAFETY GLASS
SILL STARTER
10CORNER POST
Scale: 3"=1'-0"
DOUBLE STUD
PARTITION AS SCHEDULED
8GLAZING DETAIL AT BUTT JOINT
Scale: 6"=1'-0"
CLEAR SEALANT AT GLAZING BUTT JOINT
SAFETY GLASS
PARTITION AS SCHEDULED
104.59°
12ALUMINUM HINGE JAMB W/ SIDELIGHT
Scale: 3"=1'-0"
SAFETY GLASSALUM JAMB
ALUM SNAP-ON TRIM
1 1/2"
DOOR SEAL
ALUMINUM DOOR
DOOR HINGE
1
1
1
1 1
1
F1
SINGLE DOOR
F2
DOUBLE DOOR
3'-0"
4'-6"
8'-7
1/2
"
7'-0
"
1 1/2" 1 1/2"
1 1/2" 1 1/2"
F3
SINGLE DOORW/ SIDELIGHT
3'-0"
7'-0
"
1 1/2" 1 1/2"
F4
SINGLE DOORW/ DOUBLE SIDELIGHT
4'-6"
1 1/2"
F5
DOUBLE DOORW/ SIDELIGHT
1 1/2" 1 1/2"
10'-6"
3'-6
"
1 1/
2"
1 1/2" 1 1/2"
4'-8"
6'-1
0"
2'-9" 1'-6 1/2"
1 1/2"
F6
WINDOW
F7
WINDOW
F8
FULL HEIGHT WINDOW
1'-5 1/2"
1'-6
"
3' - 0"
1 1/2"
VARIES
2'-4
"4'
-5"
1'-9
"
1'-1
0"
1 1/2" 1 1/2"
VARIES
9'-0
"
1 1/
2"
EQ EQ EQ
2'-4
"4'
-5"
1'-9
"
1'-9
"7'
-0"
1'-2
"
1
1
1
D1
SINGLE DOOR
D3
DOUBLE UNEVENFULL GLASS
3' - 0" 6' - 0"
7' -
0"
7' -
0"
D2
SINGLE FULL GLASS DOOR
D4
DOUBLE EVEN DOOR
7' -
0"
3' - 0"
7' -
0"
6"5'
-8"
10"
6" 2'-0" 6"
6"5'
-8"
10"
6" 2'-0" 6"6"6"6"
INFILL WITH ALUMINUM PANEL IN LIEU OF GLASS FOR DOOR 403
1
Architect of RecordEllenzweig
230 Congress StreetBoston, MA 02110T 617 491-5575F 617 868-2318
MEP | FA | FPAllied Engineering