Office Partitions With Electric - Global Industrial · Office Partitions With Electric 4/16/10 3:17 PM Page 8. 1-800-645-2986 OFFICE PARTITIONS Assembly Instructions P1 E STEP 6 Fit
Post on 29-Sep-2020
1 Views
Preview:
Transcript
Assembly Instructions1-800-645-2986OFFICE PARTITIONS
12
N
STEP 1Remove opening blanks onraceway cover for power and data.If panel contains no electric or dataand is used as a pass-thru, leaveopening blanks in place.
Rear view
Data PortOpenings
Power Box Opening
Rear View
Front View
STEP 2Insert data ports and data cables beforeinstalling raceway cover. (Phone connectors,data connectors and cables not included.)Removable, hinged raceway cover allowseasy access to receptacles and cables
P
Notch
RearPanel
Notch Lip
Lip
Lip
Notch
STEP 1Place notches in raceway
cover over the lipslocated on raceway leg.
STEP 2Swing panel upward untilmagnet snaps into place.
Adjust accordingly.
TIPPush or pull magnetic tabs in or out
for a better fit. Adjust as needed.
O
Use cable tie bracketto dress data cablesunder panels.
Use twist tiesor zip ties tofasten cablesunder panelsas needed.
Office Partitions With Electric 4/16/10 3:17 PM Page 1
globalindustrial.com
Office Partitions With Electric
AssemblyInstructions
Customer Service1-800-645-2986
WARNINGIn order to prevent structural failure, instability, tip-over, and/or serious injury, please follow instructionscarefully.
• Use only the instructions, parts andhardware included
• Maximum span for connectedpanels without support is 12 feet
• Do not move panels while they are connected together
• Maximum span for connectedpanels using overhead cabinets orshelves without support is 12 feet
• Consult licensed electrician forproper installation
Adjust all levelers toapproximately 1-1/4”
HARDWARE
ASSEMBLY• Configurations require the corresponding
steps needed for proper assembly.• Attach appropriate brackets or legs on
the ends of the panels as needed.• Do not attach bolts or brackets into the
outermost edge of a panel that will belast in line.
• Starter panel should use a corner,3-way, 4-way, or wall bracket.
• Insert bolt cap into unused threadedinsert to finish your project.
• Level each panel as you go along.
12’ 12’
1
1 2 IG 4
H1 H2 H3 H4 H5 H6 H8
H9 H10 H11 H12 H13 H14 H15
Straight Connector 3-way ConnectorWall Bracket Corner Connector 4-way Connector Bracket 90 ̊Connector
Screw Toggle BoltT-Bracket Straight Extension Hex Bolt Threaded Stud Panel Filler Cap
H16 H17 H18 H19 H20 H21
Aluminum PlatePanel Filler Post Bolt Cap Screw 36” Power Box 48” Power Box
H22 H23 H24 H25 H26 H27 H28
Raceway Cover 72” Starter Cable60” Power Box Panel Raceway 144” Starter Cable 20 AMP Plug 15 AMP Plug
H29 H30 H31 H32 H33 H34 H35
Circuit 1 Circuit 2Extended/Corner
Cable Circuit Tool Circuit 3 (IG) Circuit 4 Blank
H36 H37 H38
3-Way CapEnd Cap Corner Cap
12’ 12’
OverheadCabinets
OverheadShelves
Office Partitions With Electric 4/16/10 3:17 PM Page 2
Assembly Instructions1-800-645-2986OFFICE PARTITIONS
2
Go To“A”
Go To“B”
Go To“C”
Go To“D” Go To
“E”
Go To“F”
Go To“H”
Go To“I”
Go To“G”
Office Partitions With Electric 4/16/10 3:17 PM Page 3
Assembly Instructions1-800-645-2986OFFICE PARTITIONS
9
I
P1
P1
P1
P2
P3P2
P3
P3
H13 H9
H9
H9
H13
H4 H9 H11 H13 H14 H15 H16 H18 H19
(2) (1) (2) (12) (4) (2) (1) (3/6)* (6/12)*
H15H16
STEP 5Loosely attach
top bolts
STEP 6Insert panel filler capsinto panel filler post
top and bottom
STEP 7Insert post into bottom bracketfirst. Fit panel studs into bottombracket then attach bracket to
panel 2. Tighten bolts.
STEP 8Align panel 1 to bracket
and screw in self tappingscrews and washers H11
into side of panel 1.
H11
H16
STEP 1Remove feet from panel.
Attach connectors totop and bottom.
STEP 2Attach raceway
to bottom ofpanels. Add feet
and bottombracket.
STEP 3Attach aluminumplate(s) to bottom
of raceway.
H19
H18
H14
P2
STEP 4Insert panel studs.
*1 plate, 2 screws per 36" panel. 2 plates, 4 screws per 48" or 60" panel.
Office Partitions With Electric 4/16/10 3:17 PM Page 4
Assembly Instructions1-800-645-2986OFFICE PARTITIONS
8
H - Right
P1P2
P2
H15H16
H7
H - Left
P2P1
P2
P1
H15H16
H7
STEP 6Insert panelfiller caps intopanel filler posttop and bottom.Insert post intobottom bracketfirst, then intotop bracket.Then tighten allbolts firmly
STEP 6Insert panelfiller caps intopanel filler posttop and bottom.Insert post intobottom bracketfirst, then intotop bracket.Then tighten allbolts firmly
STEP 7Align panel to bracket and
screw in using 2 self tappingscrews and washers (H11) until
tight (do not overtighten).
P1P2
H11
H11
H13
STEP 1Remove feet from panel.
Attach connectors totop and bottom.
STEP 1Remove feet from panel.
Attach connectors totop and bottom.
P1
STEP 2Attach raceway to
bottom of panels. Addfeet and bottom bracket.
H13
STEP 2Attach raceway to
bottom of panels. Addfeet and bottom bracket.
STEP 3Attach
aluminumplate(s) to
bottomof raceway.
H18H19
STEP 3Attach
aluminumplate(s) to
bottomof raceway.
H18H19
H14
STEP 4Insert panel
studs.
H14
STEP 4Insert panel
studs.
STEP 5Loosely attach
top bolts.
STEP 5Loosely
attach topbolts.
H2 H7 H11 H13 H14 H15 H16 H18 H19
(1) (2) (2) (8) (2) (2) (1) (2/4)* (4/8)*
STEP 7Align panel to
bracket and screwin using 2 self
tapping screwsand washers (H11)until tight (do not
overtighten).
*1 plate, 2 screws per 36" panel. 2 plates, 4 screws per 48" or 60" panel.
Office Partitions With Electric 4/16/10 3:17 PM Page 5
Assembly Instructions1-800-645-2986
3
OFFICE PARTITIONSA
Note: Hardwareto anchor wallbracket to wall isnot provided.
P1
H13
B
P1 P2
P2
P2
P1
P1
H16
H15
H2
H13
P1
Foam seal mayneed to be trimmed
to fit panel.
H1
H14
H13
H13
H19
H18STEP 4
Insert panel studs.
H1 H13 H18 H19
(2) (6) (1/2)* (2/4)*
STEP 1Remove feet from panel.
Attach connectors totop and bottom.
STEP 2Attach raceway
to bottom ofpanels. Add feet
and bottombracket.
STEP 3Attach aluminumplate(s) to bottom
of raceway.
STEP 6Fit panel
studs intobottombracket,
then looselyattach to top
bracket.
STEP 7Insert panel
filler caps intopanel filler post
top andbottom. Insert
post intobottom bracketfirst, then intotop bracket.
Then tighten allbolts firmly.
STEP 1Remove feet from panel.
Attach connectors totop and bottom.
STEP 2Attach raceway
to bottom ofpanel. Add feet
and bottombracket.
STEP 3Attach aluminumplate(s) to bottom
of raceway.
H19
H18 STEP 4Attach to wall
(2) (10) (2) (2) (1) (2/4)* (4/8)*
H2 H13 H14 H15 H16 H18 H19
STEP 5Loosely attach top
bolts.
*1 plate, 2 screws per 36" panel. 2 plates, 4 screws per 48" or 60" panel.
Office Partitions With Electric 4/16/10 3:17 PM Page 6
Assembly Instructions
P1
1-800-645-2986
4
OFFICE PARTITIONS
C
D
STEP 4Loosely attach
top bolts
STEP 4Loosely attach
top bolts
P1P2
P1
P2
P3
STEP 6Fit panel studs into
bottom bracket, then boltand tighten top bracket
P2P3
STEP 7Insert panel filler caps into panel fillerpost top and bottom. Insert post into
bottom bracket first, then into topbracket. Then tighten all bolts firmly
H15
H16
Foam seal mayneed to be trimmed
to fit panel
H3 H13 H14 H18 H19
(2) (10) (2) (2/4)* (4/8)*
P2P3
H13
H4
P1
P1
STEP 3Attach aluminumplate(s) to bottom
of raceway.
H19
H18
STEP 3Attach aluminumplate(s) to bottom
of raceway. H19
H18
H13
H13
H13
H3
H14
H14
P2
STEP 1Remove feet from panel.
Attach connectors totop and bottom.
STEP 1Remove feet from panel.
Attach connectors totop and bottom.
STEP 2Attach raceway
to bottom ofpanels. Add feet
and bottombracket.
STEP 2Attach raceway
to bottom ofpanels. Add feet
and bottombracket.
STEP 5Insert panel
studs
STEP 5Insert panel
studs
STEP 6Fit panel studs into
bottom bracket, thenloosely attach to top
bracket
Foam sealmay need tobe trimmedto fit panel
H4 H13 H14 H15 H16 H18 H19
(2) (14) (4) (2) (1) (3/6)* (6/12)**1 plate, 2 screws per 36" panel. 2 plates, 4 screws per 48" or 60" panel.
Office Partitions With Electric 4/16/10 3:17 PM Page 7
Assembly Instructions
P1
1-800-645-2986
7
OFFICE PARTITIONS
G
H4 H8 H10 H12 H13 H14 H15 H16 H18 H19
(1) (1) (1) (2) (14) (4) (2) (1) (3/6)* (6/12)*
P1
P1P3
P2
P2
P3
H8 H12
H16
STEP 9Bolt on top
bracket H8 toshort panel 3.
DO NOT FORCE DRILLWARNING
TOGGLE BOLT (H12) ASSEMBLY INTO FILLER POST
31 2
H13
H8
H16
STEP 1Remove feet from panel.
Attach connectors totop and bottom.
H13
STEP 2Attach raceway
to bottom ofpanels. Add feet
and bottombracket. STEP 3
Attach aluminumplate(s) to bottom
of raceway.H19
H18
STEP 4Loosely attach
top bolts.
H14
P2P3
STEP 5Insert panel
studs.
STEP 7Assembled panels
P1 and P2.
STEP 8Fit panel studs into bottom
bracket first, then mark position
of vertical holes on filler post.
STEP 10Drill holes where
marked from
previous Step 5.
P1P2
H15H16
STEP 6Insert panel filler
caps into fillerpost top and
bottom. Insertpost into bottombracket. Fit panelstuds into bottombracket, then boltand tighten top
bracket.
STEP 11Follow toggle
bolt assembly
diagram.
*1 plate, 2 screws per 36" panel. 2 plates, 4 screws per 48" or 60" panel.
Office Partitions With Electric 4/16/10 3:17 PM Page 8
Assembly Instructions1-800-645-2986OFFICE PARTITIONS
P1
E
STEP 6Fit panel studs from panel 2 and 3
into bottom bracket on panel 1,
then loosely attach to top bracket
P2
P3
P1
P2
P3
P4
P1
5
STEP 1Remove feet from panel.
Attach connectors totop and bottom.
STEP 2Attach raceway
to bottom ofpanels. Add feet
and bottombracket.
H13
P2P3P4
H14
STEP 3Attach aluminumplate(s) to bottom
of raceway.H19
H18
STEP 4Loosely attach
top bolts
STEP 5Insert panel
studs
H5
H13
Foam seal mayneed to be trimmed
to fit panel
H5 H13 H14 H18 H19
(2) (18) (6) (4/8)* (8/16)*
STEP 7Fit panel studs into bottom bracket
first, then into top bracket. Thentighten all bolts.
*1 plate, 2 screws per 36" panel. 2 plates, 4 screws per 48" or 60" panel.
Office Partitions With Electric 4/16/10 3:17 PM Page 9
Assembly Instructions1-800-645-2986
F
H3
OFFICE PARTITIONS
H13
H8
STEP 6Align panel to bracket and screw
in using 2 self tapping screwsand washers (H11) until tight
(do not overtighten).
P1
P2
6
H11
H3 H8 H11 H13 H14 H18 H19
(2) (1) (2) (8) (2) (2/4)* (4/8)*
P1
STEP 3Attach
aluminumplate to bottom
of raceway.
H19
H18
H13
H14
P2
STEP 1Remove feet from
panel. Attachconnectors to
top and bottom.
STEP 2Attach raceway
to bottom ofpanel. Add feet
and bottombracket.
STEP 4Insert panel studs. Foam seal may need
to be trimmed to fit panel
P2
P1
STEP 5Bolt and tighten top
bracket H8 onto panel 2.
STEP 6Fit panel studs into
panel bracket.
*1 plate, 2 screws per 36" panel. 2 plates, 4 screws per 48" or 60" panel.
Office Partitions With Electric 4/16/10 3:17 PM Page 10
Assembly Instructions1-800-645-2986OFFICE PARTITIONS
J INSTALLATION OF POWER BOX
Insert power box to rail underpanel. No tools required.
Move power box underpanel/raceway and align notcheson top of power box(es) withopenings on aluminum plate onbottom of raceway. Push up toconnect the two parts and move leftor right approximately 1 inch untilpower box feels snug.
Single 36" PanelPower Box
Push cable into power box until cableis fully inserted. This will be evident
when the power box latch isfully engaged and flat against
the cable end. Failure toensure the cable is
fully inserted mayresult in power
interruption.
10
Extended/CornerCable
Extended/CornerCable
Extended/CornerCable
1 2
L CABLE INSTALLATION
Pass Thru ApplicationCables run between panels as needed
Panel 1 Panel 2 Panel 3
When connecting around a 90° corner or across a 3 wayor 4 way, discard the panel to panel cable and use the
extended/corner cable.
36” PANEL
48” & 60” PANEL
Double 48" PanelPower Box
Double 60" PanelPower Box
Fire Risk. Connection to the power source, by alicensed electrician, and quantity of receptaclesused for a given circuit, must be in compliance
with all national and local electrical codes. Failureto observe this warning could result in a fire.
Risk of electrical shock. Be sure in-feed poweris disconnected to prevent personal injury.
No more than 16 simplex receptacles may besupplied by one 15 AMP circuit.
No more than 20 simplex receptacles may besupplied by one 20 AMP circuit.
Electrical connections between panels mustbe disconnected prior to removal of a
mechanical connection.
WARNING
H20
H21
H22
Office Partitions With Electric 4/16/10 3:17 PM Page 11
1 2 4IG
Assembly Instructions1-800-645-2986
LOFFICE PARTITIONS
11
Circuit 1 Circuit 2 Circuit 3 Circuit 4Isolated
ReceptacleRemoval Tool isrequired when
removingreceptacles from
power box.
Each power boxaccepts up to 6
simplex receptacles;3 per side.
M
The power system is an eight wire systemconsisting of four circuits. Each circuit israted at 20 amps/120 volts maximum. Circuit1 (black), Circuit 2 (red) and Circuit 4 (pink)share a common neutral (white) and ground(green) while Circuit 3 (blue) has anindividual neutral (gray) and ground(green/yellow). Circuits rated at 20 amps/120volts, or as permitted by local codes.
CONNECTING POWER SOURCE
SIMPLEX RECEPTACLE TYPES
Maximum 16 simplex receptacles per 15 amp circuit.Maximum 20 simplex receptacles per 20 amp circuit.
Connect starter cable to power box
STEP 1
STEP 2Use either a 15
or 20 AMPcircuit to
supply power
Have alicensed
electricianinstall a hard
wiredconnection.
(20 AMP STARTER)(15 AMP CIRCUIT 1)
(20 AMP CIRCUIT 1)
Blank
Installation usingpower pole.
Power pole notincluded.
Use blank to fill“empty” simplex
locations onpower box.
OR
OR
WARNING
Office Partitions With Electric 4/16/10 3:17 PM Page 12
Assembly Instructions1-800-645-2986OFFICE PARTITIONS
13
QSTEP 1
Depending on where your powersource comes from, remove openingblank from End Cap, Three Way orCorner Cap. Place over starter cable
and attach to bottom of panelraceway. Adjust accordingly.
STEP 2If power source does not exit from
End, Corner or Three Way, leave
opening blank in place and attached
cap as needed.
Finished End panel with powersource exiting raceway.
Finished Three Waywith power source
exiting raceway.
Finished Corner with powersource exiting raceway.
Office Partitions With Electric 4/16/10 3:17 PM Page 13
top related