Assembly Instructions 1-800-645-2986 OFFICE PARTITIONS 12 N STEP 1 Remove opening blanks on raceway cover for power and data. If panel contains no electric or data and is used as a pass-thru, leave opening blanks in place. Rear view Data Port Openings Power Box Opening Rear View Front View STEP 2 Insert data ports and data cables before installing raceway cover. (Phone connectors, data connectors and cables not included.) Removable, hinged raceway cover allows easy access to receptacles and cables P Notch Rear Panel Notch Lip Lip Lip Notch STEP 1 Place notches in raceway cover over the lips located on raceway leg. STEP 2 Swing panel upward until magnet snaps into place. Adjust accordingly. TIP Push or pull magnetic tabs in or out for a better fit. Adjust as needed. O Use cable tie bracket to dress data cables under panels. Use twist ties or zip ties to fasten cables under panels as needed.
13
Embed
Office Partitions With Electric - Global Industrial · Office Partitions With Electric 4/16/10 3:17 PM Page 8. 1-800-645-2986 OFFICE PARTITIONS Assembly Instructions P1 E STEP 6 Fit
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
STEP 1Remove opening blanks onraceway cover for power and data.If panel contains no electric or dataand is used as a pass-thru, leaveopening blanks in place.
Rear view
Data PortOpenings
Power Box Opening
Rear View
Front View
STEP 2Insert data ports and data cables beforeinstalling raceway cover. (Phone connectors,data connectors and cables not included.)Removable, hinged raceway cover allowseasy access to receptacles and cables
P
Notch
RearPanel
Notch Lip
Lip
Lip
Notch
STEP 1Place notches in raceway
cover over the lipslocated on raceway leg.
STEP 2Swing panel upward untilmagnet snaps into place.
Adjust accordingly.
TIPPush or pull magnetic tabs in or out
for a better fit. Adjust as needed.
O
Use cable tie bracketto dress data cablesunder panels.
Use twist tiesor zip ties tofasten cablesunder panelsas needed.
Office Partitions With Electric 4/16/10 3:17 PM Page 1
globalindustrial.com
Office Partitions With Electric
AssemblyInstructions
Customer Service1-800-645-2986
WARNINGIn order to prevent structural failure, instability, tip-over, and/or serious injury, please follow instructionscarefully.
• Use only the instructions, parts andhardware included
• Maximum span for connectedpanels without support is 12 feet
• Do not move panels while they are connected together
• Maximum span for connectedpanels using overhead cabinets orshelves without support is 12 feet
Insert power box to rail underpanel. No tools required.
Move power box underpanel/raceway and align notcheson top of power box(es) withopenings on aluminum plate onbottom of raceway. Push up toconnect the two parts and move leftor right approximately 1 inch untilpower box feels snug.
Single 36" PanelPower Box
Push cable into power box until cableis fully inserted. This will be evident
when the power box latch isfully engaged and flat against
the cable end. Failure toensure the cable is
fully inserted mayresult in power
interruption.
10
Extended/CornerCable
Extended/CornerCable
Extended/CornerCable
1 2
L CABLE INSTALLATION
Pass Thru ApplicationCables run between panels as needed
Panel 1 Panel 2 Panel 3
When connecting around a 90° corner or across a 3 wayor 4 way, discard the panel to panel cable and use the
extended/corner cable.
36” PANEL
48” & 60” PANEL
Double 48" PanelPower Box
Double 60" PanelPower Box
Fire Risk. Connection to the power source, by alicensed electrician, and quantity of receptaclesused for a given circuit, must be in compliance
with all national and local electrical codes. Failureto observe this warning could result in a fire.
Risk of electrical shock. Be sure in-feed poweris disconnected to prevent personal injury.
No more than 16 simplex receptacles may besupplied by one 15 AMP circuit.
No more than 20 simplex receptacles may besupplied by one 20 AMP circuit.
Electrical connections between panels mustbe disconnected prior to removal of a
mechanical connection.
WARNING
H20
H21
H22
Office Partitions With Electric 4/16/10 3:17 PM Page 11
1 2 4IG
Assembly Instructions1-800-645-2986
LOFFICE PARTITIONS
11
Circuit 1 Circuit 2 Circuit 3 Circuit 4Isolated
ReceptacleRemoval Tool isrequired when
removingreceptacles from
power box.
Each power boxaccepts up to 6
simplex receptacles;3 per side.
M
The power system is an eight wire systemconsisting of four circuits. Each circuit israted at 20 amps/120 volts maximum. Circuit1 (black), Circuit 2 (red) and Circuit 4 (pink)share a common neutral (white) and ground(green) while Circuit 3 (blue) has anindividual neutral (gray) and ground(green/yellow). Circuits rated at 20 amps/120volts, or as permitted by local codes.
CONNECTING POWER SOURCE
SIMPLEX RECEPTACLE TYPES
Maximum 16 simplex receptacles per 15 amp circuit.Maximum 20 simplex receptacles per 20 amp circuit.
Connect starter cable to power box
STEP 1
STEP 2Use either a 15
or 20 AMPcircuit to
supply power
Have alicensed
electricianinstall a hard
wiredconnection.
(20 AMP STARTER)(15 AMP CIRCUIT 1)
(20 AMP CIRCUIT 1)
Blank
Installation usingpower pole.
Power pole notincluded.
Use blank to fill“empty” simplex
locations onpower box.
OR
OR
WARNING
Office Partitions With Electric 4/16/10 3:17 PM Page 12