Transcript
FormatItem NoSLS573 codeDiscriptionQtyUnitRateAmount
Section DBILL NO :1 OFFICE BUILDING - WATER SUPPLY SCHEME Note
1. All rates & prices shall be excluive of VAT, Which should
only be shown separately in summery. As for the tender eveluation
purposes these rates & prices will be considered to be
exclusive of VAT. Item NoSLS573
codeDiscriptionQtyUnitRateAmountSECTION - DEXCAVATION AND EARTH
WORKEXCAVATINGClearingD.1.1.1Site preparation for cearing site
vegetation 3m away from outer wall and filling voids with selected
earth as directed by engineer344mD.1.2.1site preparation for
removing trees girth >500m and 1000mm and filling voids with
selected earth as directed by engineer 02nrD.1.2.2site preparation
for removing trees girth >1000m and 1500mm and filling voids
with selected earth as directed by engineer 02nrExcavation and
earth workD.2.4.1Excavation pits for columns depth not exceeding
1.0m commencing from ground level 04mD.2.4.2Excavation pits for
columns depth not exceeding 1.0m not exceeding 2.0m commencing from
ground level 0.70mD.2.5.1Excavation for foundation trenches width
exceeding 300mm and depth not exceeding 1.0m commencing from ground
level 29mD.2.5.2Excavation for foundation trenches width exceeding
300mm and depth exceeding 1.0m not exceeding 2.0m commencing from
ground level 4.9mD.7.2.1Categery B timber or suitable material for
earthwork support for pits total depth not exceeding 2.0m and
distance between opposing faces 2m171mD.7.2.1Categery B timber or
suitable material for earthwork support for foundation trenches
total depth not exceeding 2.0m and distance between opposing faces
2m19mD.8.3.1Disposal of excavated material away from site as
directed by the engineer44mD.9.1.1Filling to excavation with
selected excavated material an average depth 900mm and filling with
150mm thick layers watered compacted and well
rammed3.4mD.9.3.1Filling to make up level with selected excavated
material an average depth 200mm thick layers watered compacted and
well rammed20mD.9.3.1Filling to make up level with selected
excavated material an average depth50 mm thick layers watered
compacted and well rammed3.2mD.9.3.1Filling to make up level with
selected excavated material an average depth 125mm thick layers
watered compacted and well rammed1.5m
Section F1Item NoSLS573
codeDiscriptionQtyUnitRateAmountSECTION FCONCRETE WORKReinforcement
and formwork measured seperately uless otherwise stated.SECTION
F2INSITU CONCRETEMass concrete- Grade 15F1.18.1concrete channel
having 100mm thick walls, concrete drains complete as shown in
detail drawing50mF1.3.1.1In 100mm thick concrete bed and slab on
ground 12mF1.3.1.1In 125mm slab to slope ramp4.6mF1.3.1.1In 150mm
slab to slope porch ramp0.3mReinforced Concrete - Grade 25F1.14in
lintels1.1mF1.2.2.2In bases of column0.8mF1.2.3.2In column shaft
upto finish first floor level0.7m
Section F2Item NoSLS573
codeDiscriptionQtyUnitRateAmountSECTION F2FORMWORKformwork in
approved timber. Rate to include for splayed edges, battens,
strutting, bolting, wedging, easing, striking, and
removalF2.1.2.1200 mm height category B timber or suitable material
rough finish formwork for sides of column bases18mF2.12.1.1Catogory
B timber or suitable materialfor sides of attached isolated
columnsF2.12.2.1Catogory B timber or suitable materialfor sides of
attached square columns3.2mF2.13.1.1In sides and soffit of isolated
square beam10mF2.14.2.1To sides and soffit of lintels16m
Section F3Item NoSLS573
codeDiscriptionQtyUnitRateAmountSECTION F3 REINFORCEMENT IN INSITU
CONCRETETor/ild steel rod reinforcement cut to lengths, bent to
shape, placed in position and tied with GI wireFor beams and
lintelsF3.1.1.76mm diameter mild steel bars0.02tF3.2.1.710mm
diameter tor steel bars0.04tF3.2.2.712mm diameter tor steel
bars0.06tFor columnF3.1.1.16mm diameter mild steel
bars0.02tF3.2.1.110 mm diameter tor steel bars0.03tF3.2.2.112mm
diameter tor steel bars0.07t
Section GItem NoSLS573 codeDiscriptionQtyUnitRateItem
NoSECTION - G MASONRY WORKSECTION G1 - BRICK WORK / BLOCK
WORKG1.1.1.1.1225mm thick vertical common brick solid walls in
cement sand mortar 1:5 with English bond.167mG1.1.1.1.1113mm thick
vertical common brick solid walls in cement sand mortar 1:5 with
Streacher bond.53mSECTION G2 -STONE WORKRandom rubble masonry
vertical foundation in cement sand mortar 1:5G2.1.1.1.1475mm
wide66mG2.1.1.1.1350mm wide16mG2.1.1.1.1375mm
wide16mG2.1.1.1.1250mm wide04mSECTION -HWATER PROOFINGH.2.1.120 mm
thick horizontal damp proof course in cement sand mortar 1:3 on
250mm wide rubble foundaton and treated with two coats of hot tar
and blinded with sand16mH.2.2.120 mm thick horizontal damp proof
course in cement sand mortar 1:3 on 350mm wide rubble foundaton and
treated with two coats of hot tar and blinded with sand21m
Section KItem NoSLS573 codeDiscriptionQtyUnitRateAmountSECTION
- K METAL WORKDoors and windowsAll materials supplied,fabricated
and fixed in position complete as shown in detail on drawing and as
specified .Provition shall be made for breaking walls / concrete
floors whenever necessary and making goood as directed. Rate to be
included for supply and fix heavy quality brass ironmongory ,
inclding fixing with with brass screws to match and fixing of
security grills for windows and fanlights as directed K.1.1Glazed
panelled with Aluminium frame window (type W1) of size
1800*1650mm,complete as shown in detail on drawing and as
specified.07nrK.1.1Glazed panelled with Aluminium frame window
(type W2) of size 500*1650mm,complete as shown in detail on drawing
and as specified.02nrK.1.1Glazed panelled with Aluminium frame
fanlight (type F1) of size 500*750mm,complete as shown in detail on
drawing and as specified.05nrK.3.1Glazed panelled with Aluminium
louvers(type F2) of size 500*750mm,complete as shown in detail on
drawing and as specified.03nrK.6.1Glazed panelled with Aluminium
frame door (type D1) of size 1200*2550 complete as shown in detail
on drawing and as specified01nrK.6.1Glazed panelled with Aluminium
frame door (type D2) of size 900*2550mm,complete as shown in detail
on drawing and as specified.01nrK.6.1Aluminium frame with marine
type plywood door (type D3) of size 750*2100mm complete as shown in
detail on drawing and as specified02nrK.7.1Aluminium roller shutter
(type RS) of size 4000*2550 ,complete as shown in detail on drawing
and as specified.01nrK.9.1Glazed and Aluminium Slidding door (type
SD2) of size 900*2100 ,complete as shown in detail on drawing and
as specified.04nr
Section LItem NoSLS573 codeDiscriptionQtyUnitRateAmountSECTION
- LWOOD WORKSupplying and fixing category 'B' wrought timber for
following items, complete as shown in drawings and as directed.
Rateto be included for applying approved quality wood preservative
on all timber surfaces.L1.4.3.175x125mm purlin30mL1.4.4.150x175 mm
ridge plate4.8mL1.4.5.150x100 mm rafters357mL1.4.5.1150x175 mm hip
rafters34mL1.4.6.1 50x50 mm runner 321mL1.4.7.175x100 mm wall plate
39mL1.4.7.175x150 mm beam8.3m
Section NItem NoSLS573 codeDiscriptionQtyUnitRateAmountSECTION
- N PARTITIONSPartition workpartitioning supplied or fabricated and
fixed in position complete as shown in detail on drawing and as
specified. Provision shall be made for breaking walls and concrete
floor etc. whenever necessary and making good as directed.partition
typeN.4.1.1.1partition, type p3 3660x2700mm power coated aluminium
frame(colour to be specified ) with laminated plywood panels upto
2700 mm. And 5mm thick glazed partition. All inclusive as per
drawingmN.4.1.1.1partition, type p2 3050x2700mm power coated
aluminium frame(colour to be specified ) with laminated plywood
panels upto 2700 mm. And 5mm thick glazed partition. All inclusive
as per drawingmN.4.1.1.1partition, type p1 1890x2700mm power coated
aluminium frame(colour to be specified ) with laminated plywood
panels upto 2700 mm. And 5mm thick glazed partition. All inclusive
as per drawingmN.4.1.1.1partition, type p4 2740x2700mm power coated
aluminium frame(colour to be specified ) with laminated plywood
panels upto 2700 mm. And 5mm thick glazed partition. All inclusive
as per drawingmN.4.1.1.1partition, type p5 2815x2700mm power coated
aluminium frame(colour to be specified ) with laminated plywood
panels upto 2700 mm. And 5mm thick glazed partition. All inclusive
as per drawingmN.4.1.1.1partition, type p6 2540x900 mm power coated
aluminium frame(colour to be specified ) with laminated plywood
panels upto 2700 mm. And 5mm thick glazed partition. All inclusive
as per drawingmN.4.1.1.1partition, type p7 3275x900 mm power coated
aluminium frame(colour to be specified ) with laminated plywood
panels upto 2700 mm. And 5mm thick glazed partition. All inclusive
as per drawingmN.4.1.1.1partition, type p8 3038x900 mm power coated
aluminium frame(colour to be specified ) with laminated plywood
panels upto 2700 mm. And 5mm thick glazed partition. All inclusive
as per drawingm
Section QItem NoSLS573 codeDiscriptionQtyUnitRateAmountSECTION
- QPLUMBING/ SANITARY INSTALLATIONSAll Fixtures shall be supplied
and fixed complete including effecting connection to water main and
disposal connection as required. All sanitory fittings shall be
approved quality make and colour unless otherwise stated. P.V.C
pipe (Type 1000) specials,fittings and other material supplying,
laying, and jointing or fixing completing walls with plated (P.V.C
brackets) involves as requires or laying underground as
directed.(Pipe diameter 50 mm shall be including all specials)Note:
The following quantities are provisional.Cold water
serviceQ.1.1.220mm dia P.V.C straight pipes laying in
trenchesmQ.1.1.620 mm dia P.V.C straight pipes laying on
groundmQ.2.1.120 mm elbow fittingsnrQ.2.1.125 mm elbow
fittingsnrQ.2.1.132 mm elbow fittingsnrQ.2.1.150 mm elbow
fittingsnrQ.2.1.325x25 mm tee fittingsnrQ.2.1.325x20 mm tee
fittingsnrQ.2.1.332x20 mm tee fittingsnrQ.2.1.332x25 mm tee
fittingsnrQ.2.1.625-20 mm reducer fittingsnrQ.2.1.650-32 mm reducer
fittingsnrQ.2.1.632-20 mm reducer fittingsnrQ.14.120 mm dia stop
valvenrQ.14.125 mm dia stop valvenrQ.14.132 mm dia stop
valvenrQ.14.150 mm dia stop valvenrQ.14.1Ball valvenrQ.14.125 mm
dia non return valvenrWaste Water ServiceQ.1.1.150 mm dia uPVC
waste water pipes laying in concrete ducts.mQ.1.1.163 mm dia waste
water pipes laying in ductsmQ.1.1.140 mm dia waste water pipes
laying in ductsmQ.2.1.2Extraover for 63 mm dia PVC pipe for 90
bends nrQ.2.1.2Extraover for 63 mm dia PVC pipe for 45 bends
nrQ.2.1.3Extraover for 63 mm dia PVC pipe for 63x63 mm tees
nrQ.2.1.3Extraover for 63 mm dia PVC pipe for 63x50 mm
teesnrQ.2.1.3Extraover for 63 mm dia PVC pipe for 63x40 mm
teesnrSewage Disposal SectionQ.1.1.1110 mm dia PVC sewer
pipemQ.1.1.1110 mm dia PVC vent pipemQ.2.1.3Extrover for 110 mm dia
PVC pipe for 110x110 mm teesnrQ.2.1.2Extraover for 110 mm dia PVC
for long radius bend nrFixutures and AppliancesAll fixtures Shall
be supplied and fixed complete including effecting connection to
water main and disposal connection as required.All sanitary
fittings shall be of approved colour unless otherwise stated. As
directed by the Engineer.Q.5.1.1Europian type low level suite
comprizing of pedestral type water closet complete with strap
system. Seat cover and all necessary accesaries all complete to
woorking order as directed by Engineer.nrQ.5.1.1Wash basin
pedestral type with chromium plated high quality wash basin tap,
waste plug accesaries. All complete to working Order as Directed by
the Engineer.nrQ.5.1.1600x500 mm bathroom mirror with plastic frame
complete with fittingsnr
Section SItem NoSLS573 codeDiscriptionQtyUnitRateItem
NoSECTION - S ELECTRICAL INSTALLATIONSNote : All condute pipes are
to be concealed in walls and ceiling.wiring to be completed upto
MCB.rate to be included for necessary testing. All materials of
approved quality.(as per IEE regulation) Supplying and fixing
completed as directed.rate to be included for all pvc copper pvc
wiring involved as specified and switching including switches with
approved made complete to working order. All fixes shall be
approved quality and made to the satisfaction of the Engineer and
as specification.S.11.1.1Main electrical cable 2x6 mm (pvc copper
pvc) from electricity meter point to main circuit breake
pointmS.22.2.1Final circuit for 5A socket outletnrS.22.2.2final
socket for ceiling fansnrS.22.2.3Final Circuit for lighting
switches.nrS.23.1Final circuit for 5A socket outlet flush
typenrS.24.1One way two gang switchnrS.24.1One way three gang
switch nrS.24.1One way four gang switchnrS.24.1One way five gang
switchnrS.26.1Wall bracket lamp with glass shades nrS.26.1Water
tight pendent lamp with plastic globenrS.26.1Double flourescent
lamp with prismatic type diffuser four feet longnrS.34.1.1Single
phase 30 A ELCB with 8 number 6A miniature circuit breakers in
operated in plastic box with hinged door. Rate to be included for
suitable buss bars. nrS.41.1.1Ceiling fans having 1400mm sweep with
5 speed regulator and off position and necessary
accesariesnrS.20.1Earth electrodes complete with 50mm dia 1500mm
long heavy guage GI pipe with a brick gully driven into ground for
connecting framework connectivity conductor in order to obtain
satisfactory earth resistance reading as required by IEEnr
Section T1Item NoSLS573
codeDiscriptionQtyUnitRateAmountSECTION - T FLOOR FINISHES/CEILING
FINISHESSECTION F1 - FLOOR FINISHEST1.1.1.112mm thick rendering in
cemet sand mortar 1:3 finished smooth with neat cement floating of
approved colour.mT1.1.1.112mm thick rendering in cemet sand mortar
1:3 finished smooth with neat cement floating of approved colour on
ramp.mT1.1.1.112mm thick rendering in cemet sand mortar 1:3
finished rough floating of approved colour on porch
ramp.mT1.1.10.112 mm thick 100mm high plushed type skirting in
cement sand mrtar 1:3 and finished smooth with cement floating to
matching colour to floormT1.1.11.112mm thick render in cement sand
mortar 1:3 finished smooth with neat cement floating of approved
colour on drain.mT1.9.1Non slip type ceramic floor tiles of approed
quality make and colour laid on concreete in toilet and washing
area including beding. In cement sand mortar 1:2 with cement grout
and joints filled with cement grout of matching colour and complete
as directed by Engineer.mT1.9.1.1Homogenious ceremic floor tile of
approved quality and colour. Layed on concrete floor.porch,
clarical staff room, meter readers room, including bedding in
cement sand mortar 1:2 with cement grout and joints filled with
cement grout of matching colour and complete as shown in detailed
drawing and as directed by Engineer.mT1.9.9.112mm thick 100mm
height 1:3 cement sand mortar plush skirting to matching colour to
the floorm
Section T2Item NoSLS573
codeDiscriptionQtyUnitRateAmountSECTION T2WALL AND CEILING
FINISHESInternal plasteringT2.1.2.116 mm thick internal plastering
on brick wall in cement lime and sand mortar 1:1:5 and finished
smooth with lime floor.mT2.1.1.162.5 wide 16mm thick internal doors
and windows reveals in cement , lime, sand 1:1:5 and finished
smooth with lime puttymT2.1.1.1113mm wide internal side of
archmExternal plasteringT2.1.2.116 mm thick external plastering on
brick wall in cement lime and sand mortar 1:1:5 and finished
withsemi rough surface.mRevealsT2.1.1.162.5 wide 16mm thick
external doors and windows reveals in cement , lime, sand 1:1:5 and
finished semi rough with lime puttymT2.1.1.1175 mm wide 16mm thick
internal sides of the RSmT2.1.1.116 mm thick internal plastering on
brick wall in cement lime and sand mortar 1:1:5 and finished with
fair finish.mT2.13.2200x200mm glazes ceramic wall tile in approved
colour and quality on cement sand 1:3 tile bed and point with tile
grout to match and forming neat uniform joints between tiles in
toilet area including revealsm
Sheet13
Final BOQBILL NO :1 BUILDING NAME - Note 1. All rates &
prices shall be excluive of VAT, Which should only be shown
separately in summery. As for the tender eveluation purposes these
rates & prices will be considered to be exclusive of VAT. Item
NoSLS573 codeDiscriptionQtyUnitRateAmountSECTION - DEXCAVATION AND
EARTH WORKEXCAVATINGClearing2.001D.1.1.1Site preparation for
cearing site vegetation 5m away from outer wall and filling voids
with selected earth as directed by
engineerm985.000.002.002D.1.2.1site preparation for removing trees
girth >500m and 1000mm and filling voids with selected earth as
directed by engineer nr2,400.000.002.003D.1.2.2site preparation for
removing trees girth >1000m and 1500mm and filling voids with
selected earth as directed by engineer
nr4,200.000.002.004Excavation and earth work2.005D.2.4.1Excavation
pits for columns depth not exceeding 1.0m commencing from ground
level m572.000.002.006D.2.4.2Excavation pits for columns depth not
exceeding 1.0m not exceeding 2.0m commencing from ground level
m625.000.002.007D.2.5.1Excavation for foundation trenches width
exceeding 300mm and depth not exceeding 1.0m commencing from ground
level m572.000.002.008D.2.5.2Excavation for foundation trenches
width exceeding 300mm and depth exceeding 1.0m not exceeding 2.0m
commencing from ground level m625.000.002.009D.7.2.1Categery B
timber or suitable material for earthwork support for pits total
depth not exceeding 2.0m and distance between opposing faces
2mm365.000.002.010D.7.2.1Categery B timber or suitable material for
earthwork support for foundation trenches total depth not exceeding
2.0m and distance between opposing faces
2mm365.000.002.011D.8.3.1Disposal of excavated material away from
site as directed by the engineerm450.000.00Total of page no
010.00Item NoSLS573
codeDiscriptionQtyUnitRateAmount2.012D.9.1.1Filling to excavation
with selected excavated material an average depth 900mm and filling
with 150mm thick layers watered compacted and well
rammedm275.000.002.013D.9.3.1Filling to make up level with selected
excavated material an average depth 200mm thick layers watered
compacted and well rammedm1,375.000.002.014D.9.3.1Filling to make
up level with selected excavated material an average depth50 mm
thick layers watered compacted and well
rammed3.2m1,525.004,880.002.015D.9.3.1Filling to make up level with
selected excavated material an average depth 125mm thick layers
watered compacted and well rammed1.5m1,425.002,137.50SECTION
FCONCRETE WORKReinforcement and formwork measured seperately uless
otherwise stated.SECTION F2INSITU CONCRETEMass concrete- Grade
152.016F1.18.1concrete channel having 100mm thick walls, concrete
drains complete as shown in detail
drawingm1,871.000.002.017F1.3.1.1In 100mm thick concrete bed and
slab on ground m12,500.000.002.018F1.3.1.1In 125mm slab to slope
rampm12,500.000.002.019F1.3.1.1In 150mm slab to slope porch
rampm12,500.000.00Reinforced Concrete - Grade 252.020F1.14in
lintelsm21,016.000.002.021F1.2.2.2In bases of
columnm21,016.000.002.022F1.2.3.2In column shaft upto finish first
floor levelm21,016.000.00SECTION F2FORMWORKformwork in approved
timber. Rate to include for splayed edges, battens, strutting,
bolting, wedging, easing, striking, and removalTotal of page no
027,017.50Item NoSLS573
codeDiscriptionQtyUnitRateAmount2.023F2.1.2.1200 mm height category
B timber or suitable material rough finish formwork for sides of
column basesm200.000.002.024F2.12.1.1Catogory B timber or suitable
material for sides of attached isolated
columnsm1,365.000.002.025F2.12.2.1Catogory B timber or suitable
materialfor sides of attached square
columnsm1,365.000.002.026F2.13.1.1In sides and soffit of isolated
square beamm1,435.000.002.027F2.14.2.1To sides and soffit of
lintelsm1,435.000.00SECTION F3 REINFORCEMENT IN INSITU
CONCRETETor/ild steel rod reinforcement cut to lengths, bent to
shape, placed in position and tied with GI wireFor beams and
lintels2.028F3.1.1.76mm diameter mild steel
barst201,003.000.002.029F3.2.1.710mm diameter tor steel
barst201,003.000.002.030F3.2.2.712mm diameter tor steel
barst201,003.000.00For column2.031F3.1.1.16mm diameter mild steel
barst201,003.000.002.032F3.2.1.110 mm diameter tor steel
barst201,003.000.002.033F3.2.2.112mm diameter tor steel
barst201,003.000.00SECTION - G MASONRY WORKSECTION G1 - BRICK WORK
/ BLOCK WORK2.034G1.1.1.1.1225mm thick vertical common brick solid
walls in cement sand mortar 1:5 with English
bond.m2,743.000.002.035G1.1.1.1.1113mm thick vertical common brick
solid walls in cement sand mortar 1:5 with Streacher
bond.m1,374.000.002.036SECTION G2 -STONE WORKRandom rubble masonry
vertical foundation in cement sand mortar 1:5Total of page no
030.00Item NoSLS573
codeDiscriptionQtyUnitRateAmount2.037G2.1.1.1.1475mm
widem5,400.000.002.038G2.1.1.1.1350mm
widem4,600.000.002.039G2.1.1.1.1375mm
widem4,800.000.002.040G2.1.1.1.1250mm widem2,500.000.00SECTION
-HWATER PROOFING2.041H.2.1.120 mm thick horizontal damp proof
course in cement sand mortar 1:3 on 250mm wide rubble foundaton and
treated with two coats of hot tar and blinded with
sandm350.000.002.042H.2.2.120 mm thick horizontal damp proof course
in cement sand mortar 1:3 on 350mm wide rubble foundaton and
treated with two coats of hot tar and blinded with
sandm400.000.00SECTION - K METAL WORKDoors and windowsAll materials
supplied,fabricated and fixed in position complete as shown in
detail on drawing and as specified .Provition shall be made for
breaking walls / concrete floors whenever necessary and making
goood as directed. Rate to be included for supply and fix heavy
quality brass ironmongory , inclding fixing with with brass screws
to match and fixing of security grills for windows and fanlights as
directed 2.043K.1.1Glazed panelled with Aluminium frame window
(type W1) of size 1800*1650mm,complete as shown in detail on
drawing and as specified.nr25,591.000.002.044K.1.1Glazed panelled
with Aluminium frame window (type W2) of size 500*1650mm,complete
as shown in detail on drawing and as specified.nr10,000.000.00Total
of page no 040.00Item NoSLS573
codeDiscriptionQtyUnitRateAmount2.045K.1.1Glazed panelled with
Aluminium frame fanlight (type F1) of size 500*750mm,complete as
shown in detail on drawing and as
specified.nr4,569.000.002.046K.3.1Glazed panelled with Aluminium
louvers(type F2) of size 500*750mm,complete as shown in detail on
drawing and as specified.nr4,569.000.002.047K.6.1Glazed panelled
with Aluminium frame door (type D1) of size 1200*2550 complete as
shown in detail on drawing and as
specifiednr68,745.000.002.048K.6.1Glazed panelled with Aluminium
frame door (type D2) of size 900*2550mm,complete as shown in detail
on drawing and as specified.nr48,182.000.002.049K.6.1Aluminium
frame with marine type plywood door (type D3) of size 750*2100mm
complete as shown in detail on drawing and as
specifiednr45,025.000.002.050K.7.1Aluminium roller shutter (type
RS) of size 4000*2550 ,complete as shown in detail on drawing and
as specified.nr75,562.000.002.051K.9.1Glazed and Aluminium Slidding
door (type SD2) of size 900*2100 ,complete as shown in detail on
drawing and as specified.nr47,850.000.00SECTION - LWOOD
WORKSupplying and fixing category 'B' wrought timber for following
items, complete as shown in drawings and as directed. Rateto be
included for applying approved quality wood preservative on all
timber surfaces.2.052L1.4.3.175x125mm
purlinm225.000.002.053L1.4.4.150x175 mm ridge
platem232.000.002.054L1.4.5.150x100 mm
raftersm125.000.002.055L1.4.5.1150x175 mm hip
raftersm282.000.002.056L1.4.6.1 50x50 mm runner
m139.000.002.057L1.4.7.175x100 mm wall plate
m225.000.002.058L1.4.7.175x150 mm beamm250.000.00SECTION
L2JOINERY2.059L2.10.2.125x225mm valance board fixed to the edges of
rafters with boltsm826.000.00Total of page no 050.00Item NoSLS573
codeDiscriptionQtyUnitRateAmount2.060L2.11.2.125x225 mm barge board
fixed to edge of wall plate, purlin, and ridge plate with brass
screw nailm826.000.00SECTION - N PARTITIONSPartition
workpartitioning supplied or fabricated and fixed in position
complete as shown in detail on drawing and as specified. Provision
shall be made for breaking walls and concrete floor etc. whenever
necessary and making good as directed.partition
type2.061N.4.1.1.1partition, type p3 3660x2700mm power coated
aluminium frame(colour to be specified ) with laminated plywood
panels upto 2700 mm. And 5mm thick glazed partition. All inclusive
as per drawingm8,500.000.002.062N.4.1.1.1partition, type p2
3050x2700mm power coated aluminium frame(colour to be specified )
with laminated plywood panels upto 2700 mm. And 5mm thick glazed
partition. All inclusive as per
drawingm8,500.000.002.063N.4.1.1.1partition, type p1 1890x2700mm
power coated aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And 5mm thick glazed
partition. All inclusive as per
drawingm8,500.000.002.064N.4.1.1.1partition, type p4 2740x2700mm
power coated aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And 5mm thick glazed
partition. All inclusive as per
drawingm8,500.000.002.065N.4.1.1.1partition, type p5 2815x2700mm
power coated aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And 5mm thick glazed
partition. All inclusive as per
drawingm8,500.000.002.066N.4.1.1.1partition, type p6 2540x900 mm
power coated aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And 5mm thick glazed
partition. All inclusive as per drawingm8,500.000.00Total of page
no 060.00Item NoSLS573
codeDiscriptionQtyUnitRateAmount2.067N.4.1.1.1partition, type p7
3275x900 mm power coated aluminium frame(colour to be specified )
with laminated plywood panels upto 2700 mm. And 5mm thick glazed
partition. All inclusive as per
drawingm8,500.000.002.068N.4.1.1.1partition, type p8 3038x900 mm
power coated aluminium frame(colour to be specified ) with
laminated plywood panels upto 2700 mm. And 5mm thick glazed
partition. All inclusive as per drawingm8,500.000.00SECTION - PROOF
COVERING/ROOF PLUMBINGSupplying and fixing in position complete as
shown in detail on Drawing and as directedRoof
covering2.069P.31.1.1Zn/Al sheet roof covering on timber frame
pitch 20.rate to be apply approved quality and colour painting
suitable nailing and bolt
connection.m1,298.000.002.070P.36.1.1Ridge plate covering with
Zn/Al Ridge coverm508.000.002.071P.37.1.1hip plate covering with
Zn/Al hip coverm508.000.00Roof Plumbing2.072P.43.1.1150mm square
type Zn/Al gutter fixed to the valance board with Zn/Al brackets at
300mm centers complete as
directed.m1,186.000.002.073P.44.1.1Extraover for 150mm Zn/Al gutter
,Zn/Al end capsnr250.000.002.074P.44.1.1Extraover for 150mm running
headsnr250.000.002.075P.44.1.1Extraover for 150mm
elbownr250.000.002.076P.45.1.1100mm dia Zn/Al down pipe with the
necessary accessaries with complete to the wall with Zn/Al down
pipe clips at suitable lengthnr1,186.000.002.077P.46.1.1Extraover
100mm Zn/Al down pipe for Zn/Al down pipe shoenr450.000.00SECTION -
QPLUMBING/ SANITARY INSTALLATIONSAll Fixtures shall be supplied and
fixed complete including effecting connection to water main and
disposal connection as required. Total of page no 070.00Item
NoSLS573 codeDiscriptionQtyUnitRateAmountAll sanitory fittings
shall be approved quality make and colour unless otherwise stated.
P.V.C pipe (Type 1000) specials,fittings and other material
supplying, laying, and jointing or fixing completing walls with
plated (P.V.C brackets) involves as requires or laying underground
as directed.(Pipe diameter 50 mm shall be including all
specials)Note: The following quantities are provisional.Cold water
service2.078Q.1.1.220mm dia P.V.C straight pipes laying in
trenchesm257.000.002.079Q.1.1.620 mm dia P.V.C straight pipes
laying on groundm275.000.002.080Q.2.1.120 mm elbow
fittingsnr40.200.002.081Q.2.1.125 mm elbow
fittingsnr53.600.002.082Q.2.1.132 mm elbow
fittingsnr70.800.002.083Q.2.1.150 mm elbow
fittingsnr179.500.002.084Q.2.1.325x25 mm tee
fittingsnr87.500.002.085Q.2.1.325x20 mm tee
fittingsnr100.000.002.086Q.2.1.332x20 mm tee
fittingsnr125.000.002.087Q.2.1.332x25 mm tee
fittingsnr135.000.002.088Q.2.1.625-20 mm reducer
fittingsnr100.000.002.089Q.2.1.650-32 mm reducer
fittingsnr175.000.002.090Q.2.1.632-20 mm reducer
fittingsnr135.000.002.091Q.14.120 mm dia stop
valvenr30.000.002.092Q.14.125 mm dia stop
valvenr55.000.002.093Q.14.132 mm dia stop
valvenr70.000.002.094Q.14.150 mm dia stop
valvenr105.000.002.095Q.14.1Ball valvenr1,652.000.002.096Q.14.125
mm dia non return valvenr125.00ERROR:#REF!Waste Water
Service2.097Q.1.1.150 mm dia uPVC waste water pipes laying in
concrete ducts.m295.000.002.098Q.1.1.163 mm dia waste water pipes
laying in ductsm315.000.002.099Q.1.1.140 mm dia waste water pipes
laying in ductsm275.000.002.100Q.2.1.2Extraover for 63 mm dia PVC
pipe for 90 bends nr215.000.002.101Q.2.1.2Extraover for 63 mm dia
PVC pipe for 45 bends nr215.000.00Total of page no
08ERROR:#REF!Item NoSLS573
codeDiscriptionQtyUnitRateAmount2.102Q.2.1.3Extraover for 63 mm dia
PVC pipe for 63x63 mm tees nr240.000.002.103Q.2.1.3Extraover for 63
mm dia PVC pipe for 63x50 mm teesnr230.000.002.104Q.2.1.3Extraover
for 63 mm dia PVC pipe for 63x40 mm teesnr225.000.00Sewage Disposal
Section2.105Q.1.1.1110 mm dia PVC sewer
pipem1,074.000.002.106Q.1.1.1110 mm dia PVC vent
pipem731.000.002.107Q.2.1.3Extrover for 110 mm dia PVC pipe for
110x110 mm teesnr1,004.000.002.108Q.2.1.2Extraover for 110 mm dia
PVC for long radius bend nr1,310.000.00Fixutures and AppliancesAll
fixtures Shall be supplied and fixed complete including effecting
connection to water main and disposal connection as required.All
sanitary fittings shall be of approved colour unless otherwise
stated. As directed by the Engineer.2.109Q.5.1.1Europian type low
level suite comprizing of pedestral type water closet complete with
strap system. Seat cover and all necessary accesaries all complete
to woorking order as directed by
Engineer.nr15,240.000.002.110Q.5.1.1Wash basin pedestral type with
chromium plated high quality wash basin tap, waste plug accesaries.
All complete to working Order as Directed by the
Engineer.nr10,795.000.002.111Q.5.1.1600x500 mm bathroom mirror with
plastic frame complete with fittingsnr6,255.000.00SECTION - S
ELECTRICAL INSTALLATIONSTotal of page no 090.00Item NoSLS573
codeDiscriptionQtyUnitRateAmountNote : All condute pipes are to be
concealed in walls and ceiling.wiring to be completed upto MCB.rate
to be included for necessary testing. All materials of approved
quality.(as per IEE regulation) Supplying and fixing completed as
directed.rate to be included for all pvc copper pvc wiring involved
as specified and switching including switches with approved made
complete to working order. All fixes shall be approved quality and
made to the satisfaction of the Engineer and as
specification.2.112S.11.1.1Main electrical cable 2x6 mm (pvc copper
pvc) from electricity meter point to main circuit breake
pointm565.000.002.113S.22.2.1Final circuit for 5A socket
outletnr2,447.000.002.114S.22.2.2final socket for ceiling
fansnr4,001.000.002.115S.22.2.3Final Circuit for lighting
switches.nr2,292.000.002.116S.23.1Final circuit for 5A socket
outlet flush typenr505.000.002.117S.24.1One way two gang
switchnr343.000.002.118S.24.1One way three gang switch
nr355.000.002.119S.24.1One way four gang
switchnr370.000.002.120S.24.1One way five gang
switchnr392.000.002.121S.26.1Wall bracket lamp with glass shades
nr1,111.000.002.122S.26.1Water tight pendent lamp with plastic
globenr1,111.000.002.123S.26.1Double flourescent lamp with
prismatic type diffuser four feet
longnr4,382.000.002.124S.34.1.1Single phase 30 A ELCB with 8 number
6A miniature circuit breakers in operated in plastic box with
hinged door. Rate to be included for suitable buss bars.
nr12,503.000.002.125S.41.1.1Ceiling fans having 1400mm sweep with 5
speed regulator and off position and necessary
accesariesnr5,207.000.002.126S.20.1Earth electrodes complete with
50mm dia 1500mm long heavy guage GI pipe with a brick gully driven
into ground for connecting framework connectivity conductor in
order to obtain satisfactory earth resistance reading as required
by IEEnr5,220.000.00Total of page no 100.00Item NoSLS573
codeDiscriptionQtyUnitRateAmountSECTION - T FLOOR FINISHES/CEILING
FINISHESSECTION F1 - FLOOR FINISHES2.127T1.1.1.112mm thick
rendering in cemet sand mortar 1:3 finished smooth with neat cement
floating of approved colour.m417.000.002.128T1.1.1.112mm thick
rendering in cemet sand mortar 1:3 finished smooth with neat cement
floating of approved colour on ramp.m417.000.002.129T1.1.1.112mm
thick rendering in cemet sand mortar 1:3 finished rough floating of
approved colour on porch ramp.m417.000.002.130T1.1.10.112 mm thick
100mm high plushed type skirting in cement sand mrtar 1:3 and
finished smooth with cement floating to matching colour to
floorm268.000.002.131T1.1.11.112mm thick render in cement sand
mortar 1:3 finished smooth with neat cement floating of approved
colour on drain.m417.000.002.132T1.9.1Non slip type ceramic floor
tiles of approed quality make and colour laid on concreete in
toilet and washing area including beding. In cement sand mortar 1:2
with cement grout and joints filled with cement grout of matching
colour and complete as directed by
Engineer.m3,302.000.002.133T1.9.1.1Homogenious ceremic floor tile
of approved quality and colour. Layed on concrete floor.porch,
clarical staff room, meter readers room, including bedding in
cement sand mortar 1:2 with cement grout and joints filled with
cement grout of matching colour and complete as shown in detailed
drawing and as directed by Engineer.m3,175.000.002.134T1.9.9.112mm
thick 100mm height 1:3 cement sand mortar plush skirting to
matching colour to the floorm268.000.00SECTION T2WALL AND CEILING
FINISHESInternal plastering2.135T2.1.1.162.5 wide 16mm thick
internal doors and windows reveals in cement , lime, sand 1:1:5 and
finished smooth with lime puttym29.000.002.136T2.1.1.1113mm wide
internal side of archm36.000.00Total of page no 110.00Item NoSLS573
codeDiscriptionQtyUnitRateAmount2.137T2.1.2.116 mm thick internal
plastering on brick wall in cement lime and sand mortar 1:1:5 and
finished smooth with lime floor.m528.000.00External
plastering2.138T2.1.2.116 mm thick external plastering on brick
wall in cement lime and sand mortar 1:1:5 and finished withsemi
rough surface.m431.000.00Reveals2.139T2.1.1.162.5 wide 16mm thick
external doors and windows reveals in cement , lime, sand 1:1:5 and
finished semi rough with lime puttym36.000.002.140T2.1.1.1175 mm
wide 16mm thick internal sides of the RSm475.000.002.141T2.1.1.116
mm thick internal plastering on brick wall in cement lime and sand
mortar 1:1:5 and finished with fair
finish.m528.000.002.142T2.13.2200x200mm glazes ceramic wall tile in
approved colour and quality on cement sand 1:3 tile bed and point
with tile grout to match and forming neat uniform joints between
tiles in toilet area including revealsm3,302.000.00SECTION
VPAINTING2.143V.1.1.1Apply two coates of wall primer an two coates
of approved quality and make luxury emulsion paint on faces of
internal walls.m367.000.002.144V.1.1.1Apply two coates of wall
primer an two coates of approved quality and make luxury emulsion
paint on faces of internal doors and windows
reveal.m367.000.002.145V.1.1.1preparing and apply two coates of
primer and two coates of emulsion weather sealing paint on faces of
extrnal wallsm384.000.002.146V.1.1.1Apply two coates of wall primer
an two coates of approved quality and make luxury emulsion paint on
faces of internal walls of bath room.m367.000.002.147V.1.1.2.1Apply
two coates of wall primer an two coates of approved quality and
make luxury emulsion paint on faces of internal side of
arch.m23.000.00Total of page no 120.00Item NoSLS573
codeDiscriptionQtyUnitRateAmount2.148V.1.1.2.1Apply two coates of
wall primer an two coates of approved quality and make luxury
emulsion paint on faces of external doors and windows
reveal.m24.000.002.149V.1.1.2.1Apply two coates of wall primer an
two coates of approved quality and make luxury emulsion paint on
faces of internal sides of RS.m23.000.00SECTION WDRAINAGE SYSTEM
BELOW GROUND(following quantities are
provisional)2.150W.13.1.1construction of 600x600 mm brick masonry
man hole. All complete as directed by
Engineer.nr5,200.000.002.151W.15.1.1construction of internal
diameter 900mm brick masonary black water soakage pit. All complete
as directed by Engineer.nr13,700.000.002.152W.16.1.1construction of
1000x1000 mm brick masonry waste water pit. All complete as
directed by Engineer.nr14,200.000.00Total of page no 120.00
Page &P of &N
Sheet1Summery sheetPage numberAmount
(Rs)01020304050607080910111213TOTAL
Section VItem NoSLS573 codeDiscriptionQtyUnitRateAmountSECTION
VPAINTINGV.1.1.1Apply two coates of wall primer an two coates of
approved quality and make luxury emulsion paint on faces of
internal walls.mV.1.1.1Apply two coates of wall primer an two
coates of approved quality and make luxury emulsion paint on faces
of internal doors and windows reveal.mV.1.1.2.1Apply two coates of
wall primer an two coates of approved quality and make luxury
emulsion paint on faces of internal side of arch.mV.1.1.1preparing
and apply two coates of primer and two coates of emulsion weather
sealing paint on faces of extrnal wallsmV.1.1.2.1Apply two coates
of wall primer an two coates of approved quality and make luxury
emulsion paint on faces of external doors and windows
reveal.mV.1.1.2.1Apply two coates of wall primer an two coates of
approved quality and make luxury emulsion paint on faces of
internal sides of RS.mV.1.1.1Apply two coates of wall primer an two
coates of approved quality and make luxury emulsion paint on faces
of internal walls of bath room.m
Section WItem NoSLS573 codeDiscriptionQtyUnitRateAmountSECTION
WDRAINAGE SYSTEM BELOW GROUND(following quantities are
provisional)W.13.1.1construction of 600x600 mm brick masonry man
hole. All complete as directed by Engineer.nrW.15.1.1construction
of internal diameter 900mm brick masonary black water soakage pit.
All complete as directed by Engineer.nrW.16.1.1construction of
1000x1000 mm brick masonry waste water pit. All complete as
directed by Engineer.nr