AIR-COOLED HEAT EXCHANGER(ACHE) LAYOUT

By

VIPIN.SPIPING-MATERIALSTECHNIP INDIA

19TH JAN 2007

2AIR-COOLED HEAT EXCHANGER LAYOUT

INTRODUCTION:

WHAT IS AN AIR COOLED HEAT EXCHANGER(ACHE)?

API 661 – AIR COOLED HEAT EXCHANGER FOR GENERAL REFINERY SERVICE

CONSTRUCTIONAL DETAILS

ONE OR MORE BUNDLES OF HEAT TRANSFER SURFACES

AIR MOVING DEVICE-FAN,BLOWER

POWER TRANSMISSION DEVICE TO MECHANICALLY ROTATE FAN,BLOWER

A PLENUM BETWEEN BUNDLES AND FAN

3AIR-COOLED HEAT EXCHANGER LAYOUT

TYPES OF ACHEINDUCED DRAFT

FORCED DRAFT

A- FRAME CONFIGURATION

4AIRCOOLERS IN DIFFERENT PLOTPLAN

WE HAVE COME ACROSS AIR COOLERS ON FOLLOWING PROJECTS

GONFREVILLE

KHARGH ETHYLENE

QATAR GAS-II ( BOTH IN INLET AREA

AND UTILITY AREAS)

RASGAS-III ( UTILITY AREA)

QCS (INLET AND UTILITY AREAS)

YLNG (COMPRESSOR AREA-UNIT47)

KHURSANIA PROJECT

5AIRCOOLERS IN DIFFERENT PLOTPLAN

6AIR-COOLED HEAT EXCHANGER LAYOUT

LAYOUT REQUIRMENTS OF AIR COOLED HEAT EXCHANGER (ACHE)

AREA OF LOCATION FOR ACHE:

1. ON TOP OF MAIN PIPE RACK

• MOST COMMON LOCATION

• PIPE RACK SPACING TO BE SPECIFIED WHEN SENDING ENQUIRIES FOR COOLERS

• CLIENT APPROVAL REQUIRED FOR LOCATING ACHE ON TOP OF RACK

2. ON A SEPARATE ELEVATED STRUCTURE

• MUST BE POPERLY ELEVATED TO FACILITATE GRAVITY FEED SYSTEM

7AIR-COOLED HEAT EXCHANGER LAYOUT

PROVIDE ROOM FOR CRANE ACCESS FOR MAINTENANCE

8AIR-COOLED HEAT EXCHANGER LAYOUT

ACCESS PLATFORMS ON EITHER SIDE TO ACCESS HEADER BOX

CHECK FOR THE ROOM CLEARENCES OVER ACCESS PLATFORMS

9AIR-COOLED HEAT EXCHANGER LAYOUT

IN GENERAL AVOID LOCATING PUMPS, PRV, AND CONTROL VALVESBELOW ACHE

VIBRATIONAL REQUIRMENTS HAS TO BE CONSIDERED WHILE DESIGNING

THERMAL MOVEMENT FOR LAYOUT CONSIDERATION SHALL BE FURNISHED BY THE VENDOR.

CHECK FOR THE NO. OF PASSES

NO. OF BUNDLES NEEDS TO BE KNOWN FOR KNOWING THE NO.OF NOZZLE AVAILABLE.

10AIR-COOLED HEAT EXCHANGER LAYOUT

PIPING LAYOUT REQUIRMENTS

CORRECT CONFIGURATION OF PIPING TO GIVE EQUAL OR NEAR EQUAL DISTRIBUTION

PIPING FROM OVERHEAD AS SHORT AS POSSIBLE TO MINIMIZE PRESSURE DROP

ROUTING SHOULD BE FLEXIBLE TO AVOID OVERLOADING OF NOZZLES

PROVIDING SUITABLE PIPE SUPPORTS AND ANCHORS

11AIR-COOLED HEAT EXCHANGER LAYOUT

PIPING CONFIGURATIONS

• CASCADE AND SYMMETRICAL RAKE SHOWS GOOD DISTRIBUTION

• ASYMMETRICAL RAKE SHOWS BAD DISTRIBUTION

12AIR-COOLED HEAT EXCHANGER LAYOUT

• ROUTE LINE IN ECONOMICAL PATH.

• CHECK FOR ACCESSIBILITY OF VALVES• CHECK FOR FLEXIBILITY ( GENERALY DONE IN DETAILED STAGE)• SUPPORTING CRITERIA SHALL GE CHECKED

( GENERALY DONE IN DETAILED STAGE)

13AIR-COOLED HEAT EXCHANGER LAYOUT

TOWER TO COOLER PIPING

14AIR-COOLED HEAT EXCHANGER LAYOUT

SIDE MOUNTED INLET HEADER

• MIN INLET PIPE RUN

• LESS FLEXIBLE

CENTRALLY MOUNTED INLET HEADER

• LONG INLET PIPE RUN

• MORE FLEXIBLE

15AIR-COOLED HEAT EXCHANGER LAYOUT

SYMMETRICAL RAKE

ARRANGMENT

AIR COOLER ARRANGMENT IN

16AIR-COOLED HEAT EXCHANGER LAYOUT

• UNIFORM DISTRIBUTION

• LINE SUFFICIENTLY FLEXIBLE

• MIN. PIPE RUN FOR INLET LINES

• LINES ARE NOT OBSTRUCTING MAINTENANCE ACCESS

AIR COOLER ARRANGMENT IN

17AIR-COOLED HEAT EXCHANGER LAYOUT

CASCADE ARRANGMENT

AIR COOLER ARRANGMENT IN KHURSANIA PROJECT

18AIR-COOLED HEAT EXCHANGER LAYOUT

• MINIMUM INLET PIPE RUN

• NO INDIVIDUAL ISOLATION VALVES

AIR COOLER ARRANGMENT IN KHURSANIA PROJECT

19

AIR COOLER ARRANGMENT IN KHURSANIA PROJECT

20AIR-COOLED HEAT EXCHANGER LAYOUT

21AIR-COOLED HEAT EXCHANGER LAYOUT

22AIR-COOLED HEAT EXCHANGER LAYOUT

23AIR-COOLED HEAT EXCHANGER LAYOUT