VMware Validated Design for Software-Defined Data Center
VMworld 2017 Content: Not fo
r publication or distri
bution
• This presentation may contain product features that are currently under development.
• This overview of new technology represents no commitment from VMware to deliver these features in any generally available product.
• Features are subject to change, and must not be included in contracts, purchase orders, or sales agreements of any kind.
• Technical feasibility and market demand will affect final delivery.
• Pricing and packaging for any new technologies or features discussed or presented have not been determined.
Disclaimer
2#PBO1721BU CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Building the Cloud is Often
the Bottleneck
#PBO1721BU CONFIDENTIAL 3
VMworld 2017 Content: Not fo
r publication or distri
bution
4
VMworld 2017 Content: Not fo
r publication or distri
bution
Approaches to Implement the Software-Defined Data Center
#PBO1721BU CONFIDENTIAL 5
Custom
Do It Yourself
▪ Design a custom architecture with in-house knowledge
▪ Manually deploy and maintain multiple individual software components
Build Your Own with
VMware Validated Designs
▪ The VMware Validated Designs provide standardized architecture
designs with extensively tested interoperability of the software
components
▪ Manually deploy individual software components following the VVD
guidelines and best practices to deploy and operate the SDDC
Automated with
VMware Cloud Foundation
▪ A VMware Cloud Foundation system is an integrated SDDC platform with
built-in automation for bring-up, configuration and patching/upgrading
of the stack
▪ Automatically implement an SDDC with a validated architecture that reflects
with VMware best practices by deploying VMware Cloud Foundation
VMworld 2017 Content: Not fo
r publication or distri
bution
VMware Validated DesignsSDDC Blueprints and Practices
#PBO1721BU CONFIDENTIAL 6
VMworld 2017 Content: Not fo
r publication or distri
bution
VMware Validated DesignsPrescriptive Blueprints with Comprehensive Deployment and Operational Practices
✓Broad Use Cases
ComprehensiveDocumentation
Proven & RobustStandardized
Designs
#PBO1721BU CONFIDENTIAL 7
VMworld 2017 Content: Not fo
r publication or distri
bution
VMware Validated Designs
#PBO1721BU CONFIDENTIAL 8
A History Lesson
1.0
2.0
3.0
3.0.2
4.0
4.1
February 2016▪ 12mo of Engineering▪ Release to PSO
and Partners
September 2016
▪ 2mo of Engineering
▪ Dual Region with DR
▪ Two Pod Architecture
July 2016
▪ 3.5mo of Engineering
▪ Smaller scope.(i.e. Dual Region + DR)
November 2016
▪ 1.5mo of Engineering
▪ Added M-Seg Use Case
▪ Added IT Automating IT Guide
March 2017
▪ 1.5mo of Engineering.
▪ Major Product Updates
▪ Added ROBO
August 2017
▪ 4mo of Engineering• Minor Product Updates• Consolidated Pod
Option
VMworld 2017 Content: Not fo
r publication or distri
bution
Design Decisions
9
VMware Validated Design for SDDC
Reduces risk by providinga baseline of standardization.
Ensures the design meets the design objectives.
Reinforces standardization with justification and
implications.Easy to follow checklist form.
#PBO1721BU CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Example Design Decisions
#PBO1721BU CONFIDENTIAL 10
VMware Validated Design for SDDC
NSX Design > Routing Design > Routing Model Design Decisions (4.1)
Decision ID Design Decision Design Justification Design Implication
SDDC-VI-SDN-017 Deploy NSX Edge Services Gateways
in an ECMP configuration for
north/south routing in both
management and shared edge and
compute clusters.
The NSX ESG is the recommended
device for managing north/south
traffic. Using ECMP provides multiple
paths in and out of the SDDC. This
results in faster failover times than
deploying Edge service gateways in
HA mode.
ECMP requires 2 VLANS for uplinks
which adds an additional VLAN over
traditional HA ESG configurations.
SDDC-VI-SDN-018 Deploy a single NSX UDLR for the
management cluster to provide
east/west routing across all regions.
Using the UDLR reduces the hop
count between nodes attached to it to
1. This reduces latency and improves
performance.
UDLRs are limited to 1,000 logical
interfaces. When that limit is reached,
a new UDLR must be deployed.
SDDC-VI-SDN-019 Deploy a single NSX UDLR for the
shared edge and compute, and
compute clusters to provide east/west
routing across all regions for
workloads that require mobility across
regions.
Using the UDLR reduces the hop
count between nodes attached to it to
1. This reduces latency and improves
performance.
UDLRs are limited to 1,000 logical
interfaces. When that limit is reached
a new UDLR must be deployed.
VMworld 2017 Content: Not fo
r publication or distri
bution
Software Components
#PBO1721BU CONFIDENTIAL 11
VMware Validated Design for SDDC
VMware vRealize Automation
VMware
NSX
VMware
vRealize Operations
VMware
vSAN
VMware vSphere APIs for
Daa Protection (VADP)
VMware
vSphere
VMware
vRealize Log Insight
VMware vRealize Business for Cloud VMware Site Recovery Manager
VMworld 2017 Content: Not fo
r publication or distri
bution
vRealize Business 7.3for Cloud
vRealize Automation 7.3vSphere 6.5 U1
vSAN 6.6.1
Site Recovery Manager 6.5.1 vRealize Log Insight 4.5and Content Packs
vRealize Operations 6.6.1and Management Packs
NSX 6.3.3
Bill of MaterialsVMware Validated Design for SDDC 4.1
For a complete list refer to the release notes.
VMworld 2017 Content: Not fo
r publication or distri
bution
Environmental and External Systems Requirements
#PBO1721BU CONFIDENTIAL 15
VMware Validated Design for SDDC
Active Directory
Certificate Authority
DNS and NTP
SMTP Relay
SFTP
Rack Space
Power
Cooling
VMworld 2017 Content: Not fo
r publication or distri
bution
Dual-Region Deployment Ready
#PBO1721BU CONFIDENTIAL 16
VMware Validated Design for SDDC
Characteristics & Restrictions
▪ Regional Distance is Rather Large
▪ A Region May Be Treated as an SDDC
▪ Multiple Regions are Not Treated as a Single SDDC
Workload Placement Closer to Customer
▪ Northern California and Southern California
▪ US East Coast and US West Coast
▪ US Region and EU Region
Common Uses
▪ Disaster Recovery: One region can be the primary site
and another region can be the recovery site.
▪ Data Privacy: Address laws & restrictions in some
countries by keeping tenant data within a region in the
same country.
San Francisco, CAPrimary Region
Los Angeles, CASecondary Region
VMworld 2017 Content: Not fo
r publication or distri
bution
Availability Zones
#PBO1721BU CONFIDENTIAL 17
VMware Validated Design for SDDC
AVAILABILIITY ZONE
AVAILABILIITY ZONE Characteristics
• “Islands” of infrastructure for physical isolation or
building-level redundancy and high-availability
• Positioned within “metro” distance to allow
synchronous storage replication (~50km/30mi with low single-digit latency and large bandwidth)
• Allows the SDDC equipment across the availability
zone to operate in an active/active manner as a single
virtual data center or region
• Isolated enough from each other to stop the
propagation of failure or outage across
their boundaries
Early Access Preview
• Guidance for vSAN Stretched Clusters
within a region
VMworld 2017 Content: Not fo
r publication or distri
bution
Pods – Standard Architecture
#PBO1721BU CONFIDENTIAL 18
VMware Validated Design for SDDC
VMworld 2017 Content: Not fo
r publication or distri
bution
Pods – Consolidated Management and Workload
#PBO1721BU CONFIDENTIAL 19
VMware Validated Design for SDDCNew in Version 4.1
▪ Consolidates Management, Edge, and Workload into a single pod.
▪ Requires only a minimum of 4 ESXi hosts
▪ All functional testing and validation of the design is done using vSAN.
▪ Any supported storage may be used. Adjust the operations guidance.
▪ Network Transport
▪ Supports both L2 and L3 transport services.
▪ Scalable and vendor-neutral network, use an L3 transport.
▪ Ready for Scale
▪ Expandable to a 32 ESXi host pod.
▪ SDDC solutions easily scale – deployed w/ native or NSX load balancing in place.
▪ Transitions to Two-Pod Distributed Management and Workload (Standard)
▪ Downtime Required
▪ Single Region and Single Availability Zone
▪ License Flexibility for NSX (No Universal Objects)
External
Connection
WAN/LAN
VMworld 2017 Content: Not fo
r publication or distri
bution
High-Level Deployment Architecture Objectives
#PBO1721BU CONFIDENTIAL 20
VMware Validated Design for SDDC
Two-Pod / Standard Architecture One-Pod / Consolidated Architecture
Minimum Hosts 8 4
Management VMs420 GB vRAM,
2TB VSAN, 6 TB NFS50% - 70% less
Recoverability Dual Region Single Region (DR to cloud)
Scale (VMs) Up to 10,000 Up to 1,500
Churn Medium (up to 150/hr) Low (up to 50/hr)
Availability 99% 95%
Modularity Foundation Cloud Operations Cloud Management Foundation Cloud Operations Cloud Management
Expansion options Additional Compute Pods (Up to 32 Hosts Each) Expand Pod to 32 Hosts or Grow to 2-Pod
VMworld 2017 Content: Not fo
r publication or distri
bution
Racks
#PBO1721BU CONFIDENTIAL 21
VMware Validated Design for SDDC
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
17 18 19 20 21 22 23 24 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32
CISCO NEXUS 2248PQSTAT
1 2 3 4
ID
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
4321
4321
4321
4321
17 18 19 20 21 22 23 24 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32
CISCO NEXUS 2248PQSTAT
1 2 3 4
ID
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
4321
4321
4321
4321
17 18 19 20 21 22 23 24 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32
CISCO NEXUS 2248PQSTAT
1 2 3 4
ID
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
4321
4321
4321
4321
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
Top-of-Rack Switches for Server Connectivity
Uplinks to Spine or Corefor Inter-Pod Connectivity
ServersTwo 40GbE Uplinks
to Spine or CoreOne 48 x 1 GbE
Management SwitchTwo 48 x 10 GbE
Top-of-Rack Switches
Compatible or Certified
ConfigurationsManagement Switch for
Out-of-Band Connectivity
Two PowerFeeds
Redundant Power
VMworld 2017 Content: Not fo
r publication or distri
bution
Servers
#PBO1721BU CONFIDENTIAL 22
Management Pod – Example
1 2 3 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
SD
▪ SD/USB or SATADOM Recommended
▪ Remote Syslog
Boot
▪ On Compatibility Guide
▪ RackmountSingle or Multi-Node
▪ Blade
Form Factor
▪ 2 x Sockets min.
▪ Intel XD or AMD NX Set
▪ High-Performance in BIOS
▪ 192GB RAM min.
Compute
▪ 2 x 10 GbE to
Top-of-Rack Leaf Switches
▪ Jumbo Frames
▪ 1x 1 GbE BMC to
Out-of-Band Switch
Network
Host
▪ vSAN Hybrid or All-Flash1 x Disk Groups min
▪ Flash Device for Cache Tier1 x 200GB Flash Device min.
▪ SAS for Capacity Tier2 x 1TB SAS min.
▪ Or Any Supported Storage
Storage
SATA DOM CPU MEMORY NIC IPMIAny SupportedvSAN
VMworld 2017 Content: Not fo
r publication or distri
bution
Servers
#PBO1721BU CONFIDENTIAL 23
Shared Edge/Compute and Compute Only Pod(s) – Example
SD
▪ SD/USB or SATADOM Recommended
▪ Remote Syslog
Boot
▪ 2 x Sockets min.
▪ Intel XD or AMD NX Set
▪ High-Performance in BIOS
▪ 128GB RAM min.
Compute
Host
▪ vSAN Hybrid or All-Flashn Disk Groups
▪ SSD for Caching Tier
▪ Flash Device for
Capacity Tier
▪ Or Any Supported Storage
Storage
SATA DOM CPU MEMORY NIC IPMI
▪ On Compatibility Guide
▪ RackmountSingle or Multi-Node
▪ Blade
Form Factor
Any SupportedvSAN
▪ 2 x 10 GbE to
Top-of-Rack Leaf Switches
▪ Jumbo Frames
▪ 1x 1 GbE IPMI to
Out-of-Band Switch
Network
1 2 3 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Using vSAN? Visit vsanreadynode.vmware.com
VMworld 2017 Content: Not fo
r publication or distri
bution
Network Transport Services
▪ The VMware Validated Designs supports both L2 and L3 transport services.
▪ For a scalable and vendor-neutral data center network, use an L3 transport.
▪ When deciding to use L2 or L3, consider the following:
▪ The NSX ECMP Edge devices establish L3 routing adjacency with the first upstream L3 device to provide equal cost routing for management and workload virtual machine traffic.
▪ The investment you have today in your current physical network infrastructure.
▪ All design documentation is provided for an L3 transport. You must appropriately adjustthe design deployment and day-two operations guidance under the context of an L2 transport.
Minimal Design Requirements
▪ One 10 GbE port on each ToR for host uplinks.
▪ Host uplinks are not configured in an ether-channel (LAG/vPC)
▪ Layer 3 device that supports BGP
▪ IGMP support required by vSAN and NSX Hybrid Mode
24
VMware Validated Design for SDDC
VMworld 2017 Content: Not fo
r publication or distri
bution
Example: L3 Leaf-and-Spine Topology
#PBO1721BU CONFIDENTIAL 25
VMware Validated Design for SDDC
VMworld 2017 Content: Not fo
r publication or distri
bution
Example: L3 Leaf-and-Spine Topology ToRs
#PBO1721BU CONFIDENTIAL 26
VMware Validated Design for SDDC
VMworld 2017 Content: Not fo
r publication or distri
bution
Example: L3 Leaf-and-Spine Topology Subnet Guidelines
• Use /24 subnets to reduce confusion and mistakes when working with IPv4 subnets.
• Use .1 as the (floating) interface with .2 and .3 for Virtual Router Redundancy Protocol (VRPP) or Hot Standby Routing Protocol (HSRP).
• Use the RFC1918 IPv4 address space for these subnets and allocate one octet by region and another octet by function. For example, the mapping 172.regionid.function.0/24 results in the following sample subnets
#PBO1721BU CONFIDENTIAL 27
VMware Validated Design for SDDC
Pod Function Sample VLAN Sample IP range
Management Management 1611 (Native) 172.16.11.0/24
Management vMotion 1612 172.16.12.0/24
Management VXLAN 1614 172.16.14.0/24
Management VSAN 1613 172.16.13.0/24
Shared Edge and Compute Management 1631 (Native) 172.16.31.0/24
Shared Edge and Compute vMotion 1632 172.16.32.0/24
Shared Edge and Compute VXLAN 1634 172.16.34.0/24
Shared Edge and Compute VSAN 1633 172.16.33.0/24
Note: The above ranges are meant as samples. Your actual implementation depends on your environment
VMworld 2017 Content: Not fo
r publication or distri
bution
Example: L3 Leaf-and-Spine Topology
#PBO1721BU CONFIDENTIAL 28
VMware Validated Design for SDDC
Design for Workload Requirements
Compute Only Pods and Clusters May Span Racks
Management and Shared Edge/Compute Pods and ClustersMay Span Racks if L2 Network Transport is Used. Peer with Upstream L3.
Homogenous Nodes within the Pod
May Be Heterogeneous Pod to Pod
VMworld 2017 Content: Not fo
r publication or distri
bution
vSphere Clusters
#PBO1721BU CONFIDENTIAL 29
VMware Validated Design for SDDC
ESXi ESXi ESXi ESXi
Management Distributed Switch
Universal Management Transport Zone in Hybrid Mode
Any Supported Storage
plus NFS
VTEP VTEP VTEP VTEP VTEP VTEP VTEP VTEP
ESXi ESXi ESXi ESXi
Compute Distributed Switch
Any Supported Storage
VTEP VTEP VTEP VTEP VTEP VTEP VTEP VTEP
ESXi ESXi ESXi ESXi
Compute n Distributed Switch
Any Supported Storage
VTEP VTEP VTEP VTEP VTEP VTEP VTEP VTEP
Universal Compute Transport Zone in Hybrid Mode
plus NFS
Management ClusterMinimum 4 Nodes | vSphere HA and DRS Enabled
vSAN Ready Nodes Recommended
Shared Edge and Compute ClusterBusiness Workload Requirements | Minimum 4 Nodes
vSphere HA and DRS Enabled | Edge Resource Pool and Anti-Affinity Rules
Compute Cluster nBusiness Workload Requirements | Minimum 4 Nodes
vSAN Ready Nodes Recommended
Management StackManaged by Management Stack vCenter Server
Compute StackManaged by Compute Stack vCenter Server
Management Pod Shared Edge and Compute Pod Compute Pod n
plus NFS
VMworld 2017 Content: Not fo
r publication or distri
bution
Distributed Switches
#PBO1721BU CONFIDENTIAL 30
VMware Validated Design for SDDC
VMworld 2017 Content: Not fo
r publication or distri
bution
Storage
#PBO1721BU CONFIDENTIAL 31
VMware Validated Design for SDDC
Primary Storage
VMware vSAN is Recommended
for Management Pod
Any Supported Storage
for Shared Edge and Compute Pod
Any Supported Storage
for Compute Only Pod(s)
Secondary Storage
NFS for Backups
NFS for Log Archives
NFS for Content Library and TemplatesVMworld 2017 Content: N
ot for publicatio
n or distribution
vSAN Optional for Management Pod Primary Storage
• Previous releases required vSAN as primary storage in the management pod. This requirement has been relaxed inthe 4.1 release.
• All functional testing and validation of the design is done using vSAN.
• Although the VMware Validated Designs highly recommend the use of vSAN, in particular for the management pods, any supported storage solution may be used.
• If a storage solution other than vSAN is selected:
– You must appropriately adjust the design deployment and day-two operations guidance under the context of vSAN.
– The storage design must match or exceed the capacity and performance capabilities of the vSAN configuration in the design.
#PBO1721BU CONFIDENTIAL 32
VMware Validated Design for SDDC
0%
50%
100%
25%
75%
0%
50%
100%
25%
75%
vSAN
Datastore
Non-vSAN
Datastore
VMworld 2017 Content: Not fo
r publication or distri
bution
NFS Secondary Storage
#PBO1721BU CONFIDENTIAL 33
VMware Validated Design for SDDC
Volume 1 Volume 2
NFS Storage Array
Region A
Export for Backups
Export for
Content Library
and Templates
Export for
Log Archives
Volume 1 Volume 2
NFS Storage Array
Region B
Export for Backups
Export for
Content Library
and Templates
Export for
Log ArchivesVMworld 2017 Content: Not fo
r publication or distri
bution
vCenter Server and Platform Services
#PBO1721BU CONFIDENTIAL 34
VMware Validated Design for SDDC
VMworld 2017 Content: Not fo
r publication or distri
bution
Two-Layer Certificate Authority + Certificate Replacement
CertGenVVD tool saves you time when creating signed certificates. See VMware Knowledge Base article 2146215.
Certificate Mode
• VMCA Hybrid Mode
– All user-facing certificates are signed by a certificate authority (CA).
– All virtual infrastructure management components use TLS/SSL certificates that are signed by the VMware Certificate Authority (VMCA).
• Supports a Two-Layer CA environment.
Certificate Replacement
• If the CA-signed certificates expire after you deploy the SDDC, you must replace them individually on each affected component.
• Provides guidance for replacing all CA-signed certificates that are expiring. *
#PBO1721BU CONFIDENTIAL 35
VMware Validated Design for SDDC
VMworld 2017 Content: Not fo
r publication or distri
bution
NSX
#PBO1721BU CONFIDENTIAL 36
VMware Validated Design for SDDC
VMworld 2017 Content: Not fo
r publication or distri
bution
Distributed Logical Networking
#PBO1721BU CONFIDENTIAL 37
VMware Validated Design for SDDC
Universal Distributed Logical Router
UDLRCTRL
ECMPESG
ECMPESG
ECMPESG
ECMPESG
LEAF LEAF LEAF LEAF
BGP BGP BGP BGP
Universal Transit Logical Switch
VC PSC NSXM NSXC VC PSC NSXM
SPINESPINERegion A Region B
Virtual Networks
VMworld 2017 Content: Not fo
r publication or distri
bution
38
#PBO1721BU CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Cloud Operations
#PBO1721BU CONFIDENTIAL 39
VMware Validated Design for SDDC // vRealize Operations
VMworld 2017 Content: Not fo
r publication or distri
bution
vRealize Log Insight Cluster
vRealize Log Insight
User Interface
vRealize Log Insight Clients
vRealize
Operations
Ingestion API Syslog
Master Worker nWorker
Content Packs
+ 3rd Party
...Log Archive
NFS Export
Cloud Operations
#PBO1721BU CONFIDENTIAL 40
VMware Validated Design for SDDC // vRealize Log Insight
NSX
VMworld 2017 Content: Not fo
r publication or distri
bution
Cloud Operations
#PBO1721BU CONFIDENTIAL 41
VMware Validated Design for SDDC // vRealize Log Insight
VMworld 2017 Content: Not fo
r publication or distri
bution
Distributed Deployment with NSX
42
VMware Validated Design for SDDCVMware Validated Design for SDDC // Cloud Operations
#PBO1721BU CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
43#PBO1721BU CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
44#PBO1721BU CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Management Packs and Content PacksVMware Validated Design for SDDC
vRealize Operations 6.6Management Packs
vRealize Log Insight 4.5Content Packs
Now Included by default with product deployment.
▪ Management Pack for vCenter Server
▪ Management Pack for vRealize Log Insight
▪ Management Pack for vSAN (New in v6.6)
▪ Management Pack for vRealize Automation (New in v6.6)
▪ Management Pack for vRealize Business for Cloud (New in v6.6)
Installed post-deployment.
▪ Management Pack for NSX for vSphere
▪ Management Pack for Storage Devices
Now Included by default with product deployment.
▪ General
▪ Content Pack for vSphere
▪ Content Pack for vSAN (New in v4.5)
▪ Content Pack for vRealize Operations
Installed post-deployment.
▪ Content Pack for NSX for vSphere
▪ Content Pack for vRealize Automation 7
▪ Content Pack for vRealize Orchestrator 7.0.1+
▪ Content Pack for Linux (Added to the Architecture)
▪ Content Pack for Microsoft SQL Server
#PBO1721BU CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Region A
vRealize Automation vRealize Business
BUC
BUS
vRO
vRA IWS IMS DEM IAS SQL
vRA IWS IMS DEM IAS
Region B
IAS
Cloud Management Platform Components
#PBO1721BU CONFIDENTIAL 46
VMware Validated Design for SDDC
BUS vRealize Business Appliance
BUC vRealize Business Data Collector
SQL Microsoft SQL Server Database
VRA vRealize Automation Appliance
IWS vRealize Automation IaaS Web Server
IMS vRealize Automation IaaS Manager Service
IAS vRealize Automation IaaS vSphere Proxy Agent
DEM vRealize Automation Distributed Execution Manager
BUC
IAS
vRealize Automation
and Business
VMworld 2017 Content: Not fo
r publication or distri
bution
Distributed Deployment with NSX
47
VMware Validated Design for SDDCVMware Validated Design for SDDC // Cloud Operations
#PBO1721BU CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Cloud Management Layer – vRealize Automation
#PBO1721BU CONFIDENTIAL 48
VMware Validated Design for SDDC
User Traffic
Network Traffic
Pool ID vra-iaas-mgr-443
DNS CNAME vra01ims01.rainpole.local
Virtual Server (VIP) 192.168.11.59
Algorithm Round-Robin
Session
PersistenceNone
Health /VMPSProvision = ProvisionService
Pool ID vra-iaas-web-443
DNS CNAME vra01iws01.rainpole.local
Virtual Server (VIP) 192.168.11.56
Algorithm Round-Robin
Session
PersistenceSource IP – 1800 Seconds Expiration
Health /wapi/api/status/web = REGISTERED
Pool ID vra-svr-443 vra-svr-8443 vra-vro-8283
DNS CNAME vra01svr01.rainpole.local vra01svr01.rainpole.local vra01svr01.rainpole.local
Virtual Server (VIP) 192.168.11.53 192.168.11.53 192.168.11.53
Algorithm Round-Robin Round-Robin Round-Robin
Session
PersistenceSource IP – 1800 Seconds Expiration Source IP – 1800 Seconds Expiration Source IP – 1800 Seconds Expiration
Health /vcac/services/api/health = 204 /vcac/services/api/health = 204 /vco-controlcenter/docs
VMworld 2017 Content: Not fo
r publication or distri
bution
Disaster Recovery of SDDC Solutions
#PBO1721BU CONFIDENTIAL 49
VMware Validated Design for SDDC
Region A Non-Replicated
vRealize Log Insight
Region A Infrastructure Management
vSphere
NSX
Site Recovery Manager
vSphere Data Protection or VADP-Based Solution
Region A Replicated
vRealize Operations
vRealize Automation
vRealize Business
SRM(using vSphere Replication)
Region B Infrastructure Management
vSphere
NSX
Site Recovery Manager
vSphere Data Protection or VADP-Based Solution
Region B Non-Replicated
vRealize Log Insight
Region B Replicated
vRealize Operations
vRealize Automation
vRealize Business
SRM (using vSphere Replication)
VMworld 2017 Content: Not fo
r publication or distri
bution
Documentation
#PBO1721BU CONFIDENTIAL 50
VMware Validated Design for SDDC
≠
Release Notes
Architecture Details
Architecture Diagrams
Planning and Preparation Guides
Step-by-Step Deployment Guides
Operations Guides
▪ Monitoring and Alerting
▪ Business Continuity
▪ Disaster Recovery
▪ Plus more Operations Add-ons
Download the Docs Todayvmware.com/go/vvd-docs
VMware Validated Design 4.1 Documentation Center
VMworld 2017 Content: Not fo
r publication or distri
bution
Sizing Tool on VMware Code
Provide qualified partners a sizing tool for deployments adhering to the VMware Validated Design for SDDC
Online web based tool which integrates with VMware Compatibility Guide to pull certified vSAN ReadyNodedetails
vmware.com/go/vvd-sizing
#PBO1721BU CONFIDENTIAL 51
VMware Validated Design for SDDC
VMworld 2017 Content: Not fo
r publication or distri
bution
52
Download the Poster Todayvmware.com/go/vvd-sddc-poster
#PBO1721BU CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Get StartedVMware Validated Design for SDDC
Access the Documentation
vmware.com/go/vvd-docs