AZIENDA CERTIFICATA DA DNV=UNI EN ISO 9001:2008=
COMPANY CERTIFIED BY DNV=ISO 9001:2008=
Elettromeccanica Piossasco S.r.l.Via Berchet, 22/24 - 10045 PIOSSASCO (TO) Italy
Tel. ++39 011.904 21 32 / 33 - Fax ++39 011.906 54 82
[email protected] - www.elpitalia.com
Elettromeccanica Piossasco nel mondoVENDITORI - DISTRIBUTORI ITALIA
FOREIGN VENDORS - DISTRIBUTORS
VENETO – TRENTINOT.K.R. di G. MOZZATOBorgata Soravia, 6432046 SAPPADA (BL)Tel. 349.2688298 - Fax 049.8843060e-mail: [email protected]
LOMBARDIA
Per le province di BG e BS:
ELETTRORAPPRESENTANZE INDUSTRIALI s.a.s.Via Enrico Fermi, 12/1424050 Grassobbio (BG)Tel. 035.526858 - Fax 035.526872e-mail: [email protected]
Per le province di PC e CR:
AGEA s.r.l.Via Emila Pavese, 99/B29121 PiacenzaTel. 0523.498.510 - Fax 0523.073466e-mail: [email protected]
EMILIA ROMAGNAFERIOLI MARCO & C. s.n.c.Via dei Cedri, 6840050 MONTERENZIO (BO)Tel./Fax 051.6557844 - Cell. 348.0949832e-mail: [email protected]
TOSCANASARTI SILVANOVia L.F. Menabrea, 550100 FIRENZE (FI)Tel. 055.679268 - Fax 055.6594630e-mail: [email protected]
MARCHEEDIF s.p.a.Via Valadier, 1662014 CORRIDONIA (MC)Tel. 0733.285911 - Fax 0733.281355e-mail: [email protected]
LAZIOR.E.I.L. s.n.c. di Cavalieri M. & C.Str. Vicinale Cerqueta Centrone, 600024 CASTEL MADAMA (Roma)Tel./Fax 0774.449688 - Cell. 337.782173 - 336.656723e-mail: [email protected] - [email protected]
CAMPANIAMAJORANO spa www.majorano.itVia Argine, 508 - 80147 NAPOLI (NA)Sede Legale Sede NapoliTel. 081.5914111 - Fax 081.5914264/29e-mail: [email protected] Vendita: Avellino - Battipaglia - Quarto
PUGLIALOCONSOLE P.V.A. sasSS 16 m 813+835, nr.1870126 Bari (BA)Tel. 080.5432390/91 - Fax. 080.5434049e-mail: [email protected]
CALABRIAMAJORANO CALABRIA s.r.l.www.majorano.itVia Argine, 508 - 80147 NAPOLI (NA)Sede Legale: Rende (CS)Tel. 0984.402755 - Fax 0984.839363e-mail: [email protected] Vendita: Crotone (KR) - Rossano (CS) Lauria (PZ)
SICILIAPIZZONE BENEDETTO & C. sncVia Lenin, 195 95045 LINERI MISTERBIANCO (CT)Tel 095.476963 - Fax 095.476307e-mail: [email protected]
SARDEGNAARAMU P.I. BASILE PAOLO RappresentanzeVia Ferrarsi snc - 09092 ARBOREA (OR)Tel. 0783.800300 - Fax 0783.802035e-mail: [email protected]
PRINCICIPAL COUNTRY WITH LOCAL AGENT OR DISTRIBUTOR:
AUSTRIAGERMANYFRANCECZECH REPUBLICBELGIUMPOLANDRUMANIAGREECENORWAYSWEDENUKRAINE
YEMENTUNISIELIBYASAUDI ARABIAUNITED ARAB EMIRATESGHANACONGOTANZANIAANGOLAKENYANIGERIA
Edi
zion
e 20
12
OIL IMMERSED DISTRIBUTION TRANSFORMERS
CAST RESIN DISTRIBUTION TRANSFORMERS
DRY TYPE TRANSFORMERS AND AUTOTRANSFORMERS
TRASFORMATORI DI DISTRIBUZIONE IN
OLIO
TRASFORMATORI DI DISTRIBUZIONE IN
RESINA
TRASFORMATORI E AUTOTRASFORMATORI A
SECCO
DEF. cop 62°:Layout 1 8-11-2011 15:20 Pagina 1
PresentazioneLa Elettromeccanica Piossasco nasce dalla trasformazione della Elettromeccanica Luparia fondata agliinizi degli anni ‘50 dal Sig. Giacinto e dal figlio Ing. Alessandro.La produzione originaria comprendeva ogni tipo di macchina elettrica, compresi i gruppi elettrogeni.Nel 1962, con la costruzione della sede in Piossasco (To),la ditta si è trasformata in Elettromeccanica Piossasco specializzandosi esclusivamente nella costruzione dei trasformatori. In tutti questi anni la crescita è stata costante grazie a lungimiranza, tenacia ed un serio impegno che ha portato il marchio EP ad essere conosciuto ed apprezzato sia in ambito nazionale che estero.Attualmente la ditta è diretta dai figli dell’Ing. Alessandro, i Sig.ri Giacinto, Lorenzo ed Andreaed è proiettata al consolidamento del marchio, attraverso losviluppo di nuove sinergie seguendo le esigenze di un mer-cato sempre più esigente e competente.
PresentationElettromeccanica Piossasco firm born from the transformation of Elettromeccanica Luparia established inthe beginning of the 50th by Mr. Giacinto and his son Eng. Alessandro.At the beginning the production was including every elec-trical machine, power generator set included.In 1962 with the building of the factory in Piossasco (To),the firm changed in Elettromeccanica Piossasco, with theexclusive specialization in distribution transformers. Since past years up today the growing up was continuous thanks also to our willing and serious and per-sistent efforts who let E.P. firm well known in Italy and inthe foreign countries.Today the firm is controlled by the sons of the Eng. Alessandro, Mr. Giacinto, Lorenzo and Andrea and itis looking for the consolidation the own trade mark,through the satisfied of a market more and more exacting and qualified.
da II di cop a pag 5:Layout 1 8-11-2011 15:34 Pagina 1
1
Produzione avvolgimenti MT/BT
HV/LV windings production
Linea di taglio CNC lamierino magnetico per i nuclei
Magnetic coreʼs CNC cutting machine
Montaggio nuclei su appositi banchi
Coreʼs assembly on special workbench
Avvolgimenti MT/BT
HV/LV windings
da II di cop a pag 5:Layout 1 8-11-2011 15:34 Pagina 2
Carpenteria
Carpentry
2
da II di cop a pag 5:Layout 1 8-11-2011 15:34 Pagina 3
Trattamenti termicie riempimento casse
sotto vuoto
Thermics treatments andunder vacuum filling up oil
in the tank
3
Linea di montaggio
Assembling line
da II di cop a pag 5:Layout 1 8-11-2011 15:34 Pagina 4
Esecuzione e dotazioni standard1 - isolatori passanti in porcellana per MT 2 - isolatori passanti in porcellana per BT e neutro3 - commutatore di tensione manovrabile dall’esterno
a trasformatore disinserito4 - pozzetto termometrico5 - golfari di sollevamento6 - conservatore d’olio (da KVA 1.000 a KVA 3.000)7 - livello a quadrante (per trasformatori con conservatore)8 - capsula silicagel completa di sali
(per trasformatori con conservatore)9 - tappo di riempimento, tipo:
- valvola di scoppio per trasformatori con conservatore
- valvola di sovrapressione per trasformatori a riempimento integrale
10 - ruote 11 - valvola di scarico12 - morsetto terra13 - targa dati
Esecuzione e varianti a richiesta14 - termometro a quadrante a due contatti normalmente
aperti (NA) (da KVA 800 di serie)15 - Relè Buchholz per trasformatori con conservatore
(da KVA 1.000 di serie)16 - dispositivo DGPT (per trasformatori senza
conservatore, a riempimento integrale)- doppia tensione primaria- doppia tensione secondaria- perdite e tensioni differenti da quelle indicate- collegamenti e gruppi vettoriali differenti da quelli indicati
- frequenza Hz 60- isolatori MT di tipo sconnettibile (elastimold)- cassonetti di protezione per isolatori MT e/o BT- muffole per connessioni MT- slitte per appoggio su palo- cassetta centralizzazione contatti ausiliari cablata- olio siliconico- schermo tra avvolgimento primario e avvolgimento secondario
Execution and equipment by request14 - thermometer with two connections normally open (NO)
(from KVA 800 price included)15 - Buchholz Relay for transformer with oil keeper
(from KVA 1.000 price included)16 - DGPT relief device
(for transformer integral filling type)- double HV- double LV- losses and voltage different than indicated- connections and vectorial groups different than
indicated- frequency Hz 60- HV bushings disconnected type (elastimold)- air cable box for HV and/or LV bushings- HV cable box (BSS according)- skids for pole mounted- centralized box for auxiliary circuits - siliconic fluid- sheet screen between HV and LV windings
Execution and standard equipment 1 - brown porcellain bushings for HV2 - brown porcellain bushings for LV and neutral3 - tap-changer from the cover no load handling4 - thermometer pocket5 - lifting lugs6 - oil keeper (from KVA 1.000 to KVA 3.000)7 - oil level (for transformer with oil keeper)8 - silicagel breather with salt
(for transformer with oil keeper)9 - bursting valve, type:
- relief valve for transformer with oil keeper- over pressure valve for transformer integral filling
10 - rollers 11 - drain valve12 - earthing terminal13 - name plate
14
8 96
7
15
4
5
12
10 11
12 3
16
13
4
Attacchi terminali MT e BT - HV and LV terminal connections
da II di cop a pag 5:Layout 1 8-11-2011 15:34 Pagina 5
5
NOTE:- da KVA 25 a KVA 800 esecuzione con cassa stagna ad alette a riempimento integrale senza conservatore dʼolio;
- da KVA 1.000 a KVA 1.600 esecuzione con cassa ad alette con conservatore dʼolio;- da KVA 2.000 a KVA 3.150 esecuzione con cassa a radiatori con conservatore dʼolio (a richiesta esecuzione con cassa ad alette)
NOTES:- from KVA 25 to KVA 800 execution with tank corrugated type integral filling, without oil keeper;- from KVA 1.000 to KVA 1.600 execution with tank corrugated type with oil keeper;- from KVA 2.000 to KVA 3.150 execution with tank radiators cooler with oil keeper (by request tank corrugated type)
Esempi di esecuzioni varie su specifiche e/o capitolato Cliente
Examples of differents executions according customer’s specificationsan/or standards
I dati della tabella sono indicativi e possono essere soggetti a modifica senza preavviso - Specifications of the techical data are indicative and be modified without forewarning
TRASFORMATORI TRIFASI IN OLIO tensioni di esercizio fino a Kv 24 / 0,690 - SERIE EP
THREE PHASES OIL IMMERSED TRANSFORMERS rated voltage up to Kv 24 / 0,690 - EP SERIES
25 200 780 7,0 4 3,15 3,90 780 460 1.120 360 65 300 46 55
50 235 1.250 5,3 4 2,54 3,62 790 460 1.165 360 80 350 46 57
63 250 1.500 5,0 4 2,43 3,56 800 550 1.175 360 90 400 48 58
100 380 2.000 4,0 4 2,06 3,35 920 600 1.200 520 120 500 50 59
125 440 2.400 4,2 4 1,98 3,28 930 620 1.240 520 130 600 50 59
160 500 2.900 3,5 4 1,87 3,21 1.000 620 1.240 520 150 700 55 62
200 660 3.250 3,2 4 1,69 3,08 1.035 630 1.270 520 180 800 56 63
250 770 3.950 2,9 4 1,64 3,05 1.085 780 1.300 520 220 950 58 65
315 990 5.000 2,7 4,5 1,67 3,31 1.140 745 1.360 520 240 1.100 60 67
400 1.150 6.000 2,4 4,5 1,59 3,24 1.270 790 1.430 670 270 1.300 61 68
500 1.350 7.000 2,2 4,5 1,49 3,17 1.355 860 1.455 670 330 1.500 61 69
630 1.850 9.000 2,0 6 1,59 3,93 1.460 920 1.525 670 400 1.700 62 70
800 1.950 11.000 1,9 6 1,54 3,89 1.570 990 1.590 670 450 2.100 62 72
1000 2.200 13.000 1,8 6 1,47 3,83 1.760 1.090 1.815 820 550 2.700 64 73
1250 2.500 15.200 1,8 6 1,38 3,76 1.850 1.140 1.930 820 660 3.250 66 75
1600 3.200 19.500 1,7 6 1,39 3,77 1.950 1.250 2.100 820 800 3.900 68 76
2000 3.600 23.500 1,7 6 1,34 3,73 2.500 1.560 2.160 1.070 900 4.600 70 79
2500 4.400 26.500 1,6 6 1,23 3,64 2.620 1.680 2.220 1.070 1.000 5.400 74 81
3150 5.000 32.000 1,5 6 1,19 3,61 2.700 1.720 2.300 1.070 1.200 6.400 75 83
POTENZA PERDITE WATTS CORRENTE TENSIONE CADUTA DI TENSIONE DIMENSIONI mm PESI Kg RUMOROSITA’
POWER LOSSES WATTS A VUOTO di C.C REGULATION DIMENSIONS mm WEIGHTS Kg NOISE LEVEL
KVA A VUOTO in C.C. NO LOAD Impedance COSFI’ 1 COSFI’ 0,9 LUNGHEZZA LARGHEZZA ALTEZZA INTER. PESO OLIO PESO TOT. LpA LwACURRENT Vcc % RUOTE Kg Kg ( dB ) ( dB )
NO LOAD on C.C. % LENGHT WIDTH HEIGHTWHEEL OIL WEIGHT TOT. WEIGHTBASE Kg Kg
da II di cop a pag 5:Layout 1 8-11-2011 15:34 Pagina 6
Esempi di esecuzioni varie su specifiche e/o capitolato Cliente
Examples of differents executions according customer’s specificationsan/or standards
6
TRASFORMATORI TRIFASI IN OLIO tensioni di esercizio fino a Kv 24 / 0,690 - SERIE MEC
THREE PHASES OIL IMMERSED TRANSFORMERS rated voltage up to Kv 24 / 0,690 - MEC SERIES
25 150 700 3,3 4 2,84 3,77 780 460 1.140 360 70 320 43 50
50 190 1.100 2,9 4 2,25 3,45 790 460 1.170 360 85 355 43 50
63 225 1.300 2,8 4 2,12 3,37 800 550 1.180 360 95 425 45 54
100 320 1.750 2,5 4 1,81 3,17 930 620 1.220 520 130 530 46 54
125 380 2.000 2,4 4 1,66 3,07 940 630 1.250 520 135 590 46 55
160 460 2.350 2,3 4 1,53 2,98 1.010 640 1.260 520 155 750 47 55
200 550 2.800 2,2 4 1,47 2,93 1.050 650 1.280 520 195 870 48 56
250 650 3.250 2,1 4 1,37 2,85 1.090 790 1.310 520 240 1.040 48 56
315 780 3.850 2,0 4 1,29 2,80 1.145 760 1.380 520 260 1.180 49 57
400 930 4.600 1,9 4 1,22 2,74 1.290 800 1.440 670 280 1.420 49 58
500 1.100 5.500 1,8 4 1,17 2,71 1.370 880 1.465 670 350 1.670 50 59
630 1.300 6.500 1,7 6 1,20 3,62 1.470 940 1.540 670 450 1.930 51 60
800 1.500 9.000 1,6 6 1,29 3,67 1.580 1.000 1.600 670 460 2.150 52 62
1000 1.700 10.500 1,5 6 1,22 3,63 1.770 1.100 1.825 820 570 2.800 54 63
1250 2.200 14.000 1,4 6 1,29 3,69 1.870 1.160 1.950 820 690 3.380 56 65
1600 2.600 16.000 1,3 6 1,17 3,59 1.960 1.260 2.120 820 860 4.200 57 66
2000 3.000 19.000 1,2 6 1,12 3,55 2.520 1.580 2.180 1.070 880 5.000 60 69
2500 3.800 24.500 1,1 6 1,15 3,58 2.650 1.700 2.250 1.070 1.100 5.750 63 71
3150 4.400 30.000 1,0 6 1,12 3,56 2.750 1.750 2.320 1.070 1.350 6.600 66 75
POTENZA PERDITE WATTS CORRENTE TENSIONE CADUTA DI TENSIONE DIMENSIONI mm PESI Kg RUMOROSITAʼPOWER LOSSES WATTS A VUOTO di C.C REGULATION DIMENSIONS mm WEIGHTS Kg NOISE LEVEL
KVA A VUOTO in C.C. NO LOAD Impedance COSFIʼ 1 COSFIʼ 0,9 LUNGHEZZA LARGHEZZA ALTEZZA INTER. PESO OLIO PESO TOT. LpA LwACURRENT Vcc % RUOTE Kg Kg ( dB ) ( dB )
NO LOAD on C.C. % LENGHT WIDTH HEIGHTWHEEL OIL WEIGHT TOT. WEIGHTBASE Kg Kg
I dati della tabella sono indicativi e possono essere soggetti a modifica senza preavviso - Specifications of the technical data are indicative and can be modified without forewarning NOTE: vedi pagina 5NOTES: as page 5
da pag 6 a pag 11:Layout 1 8-11-2011 15:36 Pagina 1
7
TRASFORMATORI TRIFASI IN OLIO tensioni di esercizio fino a Kv 24 / 0,690 - SERIE MEC 2
THREE PHASES OIL IMMERSED TRANSFORMERS rated voltage up to Kv 24 / 0,690 - MEC 2 SERIES
100 250 1.400 1,5 4 1,47 2,93 930 620 1.230 520 140 540 43 48
125 320 1.650 1,4 4 1,39 2,87 940 630 1.250 520 145 600 43 49
160 360 1.850 1,3 4 1,23 2,75 1.010 640 1.270 520 160 760 44 50
200 440 2.200 1,2 4 1,17 2,71 1.050 650 1.300 520 200 890 45 51
250 520 2.600 1,1 4 1,11 2,66 1.130 750 1.400 520 250 1.170 45 52
315 630 3.100 1,0 4 1,05 2,62 1.150 760 1.425 670 270 1.200 46 53
400 740 3.650 0,9 4 0,98 2,56 1.355 830 1.580 670 310 1.500 47 54
500 820 4.600 0,9 4 0,99 2,57 1.400 900 1.600 670 410 1.880 47 55
630 900 5.600 0,8 6 1,06 3,50 1.555 960 1.630 670 430 2.000 48 56
800 1.100 7.500 0,7 6 1,11 3,54 1.600 1.010 1.650 670 480 2.200 49 57
1000 1.300 9.000 0,7 6 1,07 3,51 1.780 1.110 1.830 820 580 2.850 50 58
1250 1.650 11.000 0,6 6 1,05 3,50 1.880 1.160 1.960 820 700 3.430 51 59
1600 2.000 13.000 0,5 6 0,98 3,44 1.970 1.260 2.130 820 900 4.350 52 60
2000 2.400 16.000 0,5 6 0,97 3,43 2.540 1.600 2.200 1.070 1.020 5.200 54 62
2500 2.900 21.000 0,5 6 1,01 3,47 2.720 1.750 2.280 1.070 1.200 5.900 56 66
3150 3.350 24.200 0,4 6 0,94 3,41 2.780 1.800 2.380 1.070 1.400 6.700 60 69
POTENZA PERDITE WATTS CORRENTE TENSIONE CADUTA DI TENSIONE DIMENSIONI mm PESI Kg RUMOROSITAʼPOWER LOSSES WATTS A VUOTO di C.C REGULATION DIMENSIONS mm WEIGHTS Kg NOISE LEVEL
ʻKVA A VUOTO in C.C. NO LOAD Impedance COSFIʼ 1 COSFI 0,9 LUNGHEZZA LARGHEZZA ALTEZZA INTER. PESO OLIO PESO TOT. LpA LwACURRENT Vcc % RUOTE Kg Kg ( dB ) ( dB )
NO LOAD on C.C. % LENGHT WIDTH HEIGHTWHEEL OIL WEIGHT TOT. WEIGHTBASE Kg Kg
I dati della tabella sono indicativi e possono essere soggetti a modifica senza preavviso Specifications of the technical data are indicative and can be modified without forewarning
NOTE: vedi pagina 5NOTES: as page 5
da pag 6 a pag 11:Layout 1 8-11-2011 15:36 Pagina 2
8
Esecuzioni varie e accessori
Differents executions and accessories
da pag 6 a pag 11:Layout 1 8-11-2011 15:36 Pagina 3
9
Esempio disegno cassonetti di protezione MT/BT
Drawing of example of HV/LV air cable box of protection
Principali gruppi collegamento in accordo con le norme CEI/IEC
Main connection groups according IEC (CEI) standards
Esempio disegno
Drawing of example
da pag 6 a pag 11:Layout 1 8-11-2011 15:36 Pagina 4
Trasformatori in resinaesecuzione e dotazioni standard- tensione primaria: fino a Kv 24- tensione secondaria: fino a Kv 0,5- classe d’isolamento: fino a Kv 24- collegamento: triangolo stella con neutro (altri a richiesta)- gruppo: Dyn11 o Dyn5 (altri a richiesta)- frequenza: Hz 50- nucleo con lamierino a cristalli orientati- avvolgimento primario inglobato- avvolgimento secondario impregnato- basette per la variazione tensione primaria- piastre per il collegamento BT- ruote- golfari di sollevamento- morsetto terra- n. 3 termosonde tipo PT 100 cablate in cassetta- centralina elettronica per il controllo della temperatura- targa dati- grado protezione IP 00
Cast resin transformersstandard execution and equipment- primary tension: up to Kv 24- secondary tension: up to Kv 0,5- insulation class: up to Kv 24- connection: delta star with neutral (others by request)- group: Dyn11 or Dyn5 (others by request)- frequenza: Hz 50- core with oriented grain, insulated with carlite- cast resin HV windings - impregnated LV windings- plaque for primary voltage tappings variation- plate for LV connection- rollers- lifting lugs- earthing terminal- n. 3 temperature sensor type PT 100 wired inside box - electronic temperature monitoring unit- name plate- protection degree IP 00
da pag 6 a pag 11:Layout 1 8-11-2011 15:36 Pagina 5
11
Esempi di esecuzioni varie
Examples of differents executions
NOTE: vedi pagina 5NOTES: as page 5
TRASFORMATORI TRIFASI IN RESINA tensioni di esercizio fino a Kv 24 / 0,690 - SERIE EP
THREE PHASES CAST RESIN TRANSFORMERS rated voltage up to Kv 24 / 0,690 - EP SERIES
50 380 1.780 2.000 2,2 6 1.050 620 1.000 520 530 50 57
100 530 1.880 2.200 2 6 1.100 620 1.100 520 600 50 57
160 680 2.650 3.000 1,9 6 1.250 670 1.130 520 780 51 62
200 780 2.800 3.200 1,7 6 1.300 670 1.150 520 910 52 63
250 880 3.350 3.800 1,5 6 1.300 670 1.200 520 990 54 64
315 1.000 4.200 4.800 1,4 6 1.400 820 1.240 670 1.140 55 66
400 1.200 4.850 5.500 1,3 6 1.400 820 1.360 670 1.310 56 67
500 1.350 5.900 6.700 1,2 6 1.450 820 1.390 670 1.480 56 68
630 1.650 6.850 7.800 1,2 6 1.500 850 1.540 670 1.770 57 69
800 2.000 8.350 9.500 1,1 6 1.600 850 1.580 670 2.120 58 70
1000 2.300 9.800 11.000 1,0 6 1.650 1.000 1.810 820 2.500 59 72
1250 2.750 12.000 13.500 1,0 6 1.800 1.000 1.880 820 3.000 60 74
1600 3.100 14.250 16.000 0,9 6 1.800 1.000 2.110 820 3.470 62 76
2000 3.800 16.000 18.000 0,9 6 1.850 1.300 2.330 1.070 4.380 64 77
2500 5.000 20.700 23.000 0,8 6 2.000 1.300 2.390 1.070 5.200 65 79
3150 5.700 24.300 27.000 0,7 6 2.200 1.300 2.490 1.070 6.370 67 82
POTENZA PERDITE WATTS CORRENTE TENSIONE DIMENSIONI mm / PESI Kg RUMOROSITAʼPOWER LOSSES WATTS A VUOTO di C.C. DIMENSIONS mm / WEIGHTS Kg NOISE LEVEL
KVA A VUOTO in C.C. in C.C. NO LOAD Impedance LUNGHEZZA LARGHEZZA ALTEZZA INTER. PESO TOT. LpA LwAa 75°C a 120° CURRENT Vcc % RUOTE Kg ( dB ) ( dB )
NO LOAD on C.C. on C.C. % LENGHT WIDTH HEIGHTat 75°C at 120°C WHEEL BASE TOT. WEIGHT
Kg
I dati della tabella sono indicativi e possono essere soggetti
a modifica senza preavviso
Specifications of the technical dataare indicative and can be modified
without forewarning
da pag 6 a pag 11:Layout 1 8-11-2011 15:36 Pagina 6
Esempi di esecuzioni varie
Examples of differents execution
12
Esecuzioni e varianti a richiesta- doppia tensione primaria- doppia tensione secondaria- perdite e tensioni differenti da quelle indicate- collegamenti e gruppi vettoriali differenti da quelli indicati- frequenza Hz 60- schermo tra avvolgimento primario - terminali sconnettibili tipo elastimold per MT- ventilatori per il raffredamento forzato- centralina elettronica per il controllo dei ventilatori
Executions and equipment by request- double primary voltage- double secondary voltage- losses and voltage different than indicated- connections and vectorial groups different than indicated- frequency Hz 60- sheet screen between HV and LV windings- HV disconnected terminal elastimold type- cooling fans- electronic monitoring unit for the control of the cooling fans
TRASFORMATORI TRIFASI IN RESINA tensioni di esercizio fino a Kv 24 / 0,690 - PERDITE RIDOTTE
THREE PHASES CAST RESIN TRANSFORMERS rated voltage up to Kv 24 / 0,690 - REDUCED LOSSES
250 750 3.200 3.600 1,30 6 1.350 670 1.250 520 1.080 52 62
315 880 3.880 4.400 1,25 6 1.450 820 1.300 670 1.280 53 64
400 1.000 4.600 5.300 1,10 6 1.450 820 1.400 670 1.450 53 65
500 1.150 5.950 6.500 1,06 6 1.500 820 1.400 670 1.620 53 66
630 1.430 6.650 7.500 1,06 6 1.550 850 1.570 670 1.910 54 67
800 1.730 7.850 9.000 0,90 6 1.650 850 1.600 670 2.270 55 69
1000 1.900 8.600 9.800 0,85 6 1.700 1.000 1.850 820 2.760 57 71
1250 2.300 9.900 11.800 0,85 6 1.800 1.000 1.900 820 3.280 59 72
1600 2.500 12.300 14.000 0,80 6 1.850 1.000 2.150 820 3.730 62 74
2000 3.200 16.200 18.000 0,70 6 1.900 1.300 2.350 1.070 4.450 64 75
2500 4.200 19.000 22.000 0,68 6 2.100 1.300 2.400 1.070 5.550 64 77
3150 5.000 23.200 25.800 0,65 6 2.300 1.300 2.500 1.070 6.600 66 80
POTENZA PERDITE WATTS CORRENTE TENSIONE DIMENSIONI mm / PESI Kg RUMOROSITAʼPOWER LOSSES WATTS A VUOTO di C.C. DIMENSIONS mm / WEIGHTS Kg NOISE LEVEL
KVA A VUOTO in C.C. in C.C. NO LOAD Impedance LUNGHEZZA LARGHEZZA ALTEZZA INTER. PESO TOT. LpA LwAa 75°C a 120° CURRENT Vcc % RUOTE Kg ( dB ) ( dB )
NO LOAD on C.C. on C.C. at % LENGHT WIDTH HEIGHTat 75°C at 120°C WHEEL BASE TOT. WEIGHT
Kg
I dati della tabella sono indicativi e possono essere soggetti a modifica senza preavviso Specifications of the technical data are indicative and can be modified without forewarning
NOTE: vedi pagina 5NOTES: as page 5
da pag 12 a III di copert :Layout 1 8-11-2011 15:38 Pagina 1
13
- centralina elettronica per il controllo della temperatura
- centralina elettronica per il controllo dei ventilatori- termosonde PT 100- barre di ventilazione
- electronic monitoring unit for temperature control- electronic monitoring unit for the control of the
cooling fans- temperature sensor type PT 100- cooling fans
Esempio disegno
Drawing of example
Esempi di esecuzioni varie
Examples of differents executions
da pag 12 a III di copert :Layout 1 8-11-2011 15:38 Pagina 2
Tabella dimensioni box di protezione standard
Schedule dimensions protection box standard
Box di protezione autoventilato di tipo autoportante,composto da pannelli imbullonati, montato sul carrellodelle ruote del trasformatore.Esecuzione standard: IP 31 - RAL 9002
Box of protection self-ventilated, self-carrying type, boltedpanels consists, mounted on the transformerʼs rollers base.Standard execution: IP 31 - RAL 9002
14
da pag 12 a III di copert :Layout 1 8-11-2011 15:38 Pagina 3
Disegni di esempio
Drawings of examples
15
Trasformatori in ariaesecuzioni e dotazionistandard- tensione primaria: fino a Kv 3- tensione secondaria: fino a Kv 1- classe d’isolamento: fino a Kv 3- frequenza Hz 50- nucleo con lamierino a cristalli orientati- avvolgimenti primario e secondario in rame- morsettiera:- tipo Weidmuller (fino a KVA 50)- in bachelite con bulloneria in ottone(da KVA 50 a KVA 100)
- in piastre di rame (oltre KVA 100)- piedini d’appoggio in ferro- golfari di sollevamento- morsetto terra- rifinitura in vernice isolante rossa- targa dati
Esecuzioni e variantia richiesta- doppia tensione primaria- doppia tensione secondaria- frequenza Hz 60- schermo tra avvolgimento primario e
avvolgimento secondario- cassonetto di protezione
Dry type transformersstandard execution and equipment- primary voltage up to Kv 3- secondary voltage up to Kv 1- insulation class up to Kv 3- frequency Hz 50- core with oriented grain, insulated with carlite- HV and LV copper windings- connecting terminal:
- Weidmuller type (up to KVA 50)- by bakelite with brass bolts
(from KVA 50 to KVA 100)- by copper plate (over KVA 100)
- iron feet- lifting lugs- earthing terminal- finishing touch by red insulating paint- name plate
Execution and equipmentby request- double primary voltage- double secondary voltage- frequency Hz 60- sheet screen between primary and secondary
windings- air cable box
da pag 12 a III di copert :Layout 1 8-11-2011 15:38 Pagina 4
16
Controlli di qualità - Collaudi e proveLa Elettromeccanica Piossasco opera con un Sistema Assicurazione Qualità in accordo con le norme ISO 9001:2008.La costante applicazione del Manuale Qualità e delle relative procedure operative assicura un rigoroso controllo su tutti i materiali ed i componenti in arrivo, sul magazzino, sui processi di produzione,fino ai collaudi finali ed alla consegna ai clienti. I collaudi finali presso la nostra sala prove prevedono:prove di routine: (comprese nel prezzo);prove di tipo: (extra a pagamento, su richiesta del cliente).Su richiesta del cliente è possibile effettuare prove speciali extra a pagamento presso enti esterni riconosciuti (es. CESI - Milano).E’ inoltre assicurata l’assistenza post vendita ai clienti.
Quality control - Checks and testsElettomeccanica Piossaco operate according a Quality Assurance Sistem in compliance ISO 9001:2008 Standard.The Quality Manual’s constant application, with the relatives operative procedures, guarantee a severe checking with all materials and components, with the store, with production’s processing, up to the final test and to the costumers deliver.In our test room we carry out:routine test: (price included);type test: (extra payment , by customer request)By customer request is possible carry out special test in certified institute (ex. CESI - Milano) by extra payment.After sale service is also assured.
Norme di riferimentoI nostri trasformatori vengono costruiti in conformità con le norme:Trasformatori in olio:CEI 14.4 - IEC 60076 1/12Trasformatori in aria: CEI 14.8 - IEC 726 Trasformatori in resina: CEI 14.8 - HD 464 - IEC 60076-11
Su richiesta del Cliente è possibile la costruzione di trasformatori in accordo con altre norme.
StandardOur transformers are manufactured according following standards:Oil immersed transformers:IEC 60076 1/12 - CEI 14.4Dry type transformers:EC 726 - CEI 14.8Cast resin transformers:HD 464 - IEC 60076-11 - CEI 14.8
By customer request is possible to produce transformers according other standards.
da pag 12 a III di copert :Layout 1 8-11-2011 15:38 Pagina 5
PRINCIPALI CLIENTI ITALIANI:
FERROVIE DELLO STATO Compartimenti di Torino, Genova, Alessandria, Bologna, Firenze - ENEL SpA Compartimenti di Torino, Genova, Novara -MARINA MILITARE ITALIANA - BASI NATO Arsenali di La Spezia, Napoli, Taranto, Aviano (Pd), Sigonella (Ct) - ESERCITO ITALIANO Arsenale di Pia-cenza - AERONAUTICA MILITARE ITALIANA Aeroporti di Comiso (Rg), Ghedi (Bs), 27° rep. Genio Campale (Vi) - U.S.S.L. N. 23 Torino, N. 4 Genova,N. 9 Reggio Emilia - GRUPPO FIAT - FIAT AUTO Torino, SOFIM (Fg), CIS Compagnia Italiana Strade (To) - FIAT ENGINEERING Torino, RIV-SKF Ai-rasca (To) e Villar Perosa (To) - WHITHEHEAD MOTOFIDES Marina di Pisa (Pi), SATA Melfi (Pz) Indotto FIAT - C.S.I. La Loggia (To), I.T.C.A. Gruglia-sco (To), FIBRO Quarona (Vc) - ILAS SUD Cassino (Fr), UNICAR Torino, UNICAR SUD Anagni (Fr), ELCAT Rivoli (To), FARA Beinasco (To), NUOVAFAST Cumiana (To) - FISTER Torino, VITALONI Torino, FISPA Torino, ELCAT SUD Pofi (Fr), GRUPPO GILARDINI SAVARA Beinasco (To), CROMO-DORA Venaria (To), FLEXIDER Torino
ALTRI CLIENTI PARTICOLARMENTE SIGNIFICATIVI:
NEBIOLO MACCHINE Settimo Torinese (To) - IMPRESA RECCHI Torino - HONEYWELL Caluso (To) - A.T.M. Torino - AUTOSTRADA TO/SV Torino -GRUPPO ING. BERTOLDO Nole Canavese (To) - DELTASIDER Torino - RIVOIRA Torino - COMOLI & FERRARI Novara - CARTIERE BURGO Torino- SOCIETA' GESTIONE IMPIANTI SESTRIERE Sestriere (To) - ALIVAR Novara - AZIENDA SERVIZI MUNICIPALIZZATI Settimo T.se (To) - FIMET Bra(Cn) - AZIENDA ACQUEDOTTO MUNICIPALE TORINO - CINZANO S.Vittoria (Cn) - ELETTROMARKET POLETTI & OSTA Casale Monferrato (Al) -COMINT Genova - OTO MELARA La Spezia - DE BARBIERI Genova - ITALSIDER Genova - ANSALDO COMPONENTI Genova - S.A.R.I.S. Savona,BORRA Gussago (Bs) - COSTRUZIONI ARMANDO CIMOLAI Pordenone - MARCHIOL SpA Villorba (Tv) - IMPRESA RIZZANI DE ECCHER Udine -NUOVA WALTER Cologno Monzese (Mi) - POMINI Castellanza (Va) - NUOVA MAGRINI GALILEO Milano e Bergamo - ROCKWELL Como e Gruglia-sco (To) - SECIT Milano - MEREGALLI Monza (Mi) - B & B Ingg. SpA Sesto S. Giovanni (Mi) - I.T.T. FLYGTH Cusago (Mi) - IMPRESA LODIGIANI Fran-colino di Carpiano (Mi) - DE NORA SpA Milano - WORTHINGTON POMPE Desio (Mi) - FUNIVIE VAL DI LEI Madesimo (So) - GIANNETTI RUOTECeriano Laghetto (Mi) - DE NORA SpA Milano - SIBA Soc. Italo Britannica dell'Acqua Srl Milano - ELETTROLUX Firenze - SOCIETA' IMPIANTO FU-NIVIE Abetone (Fi) - NUOVO PIGNONE Firenze - S.I.E. Soc. Imp. Isola del Giglio (Gr) - CARCERE ISOLA GORGONA (Li) - E.MA.CO. Viareggio (Lu)- IMPRESA PONTELLO Firenze - CARCERE DI POGGIBONSI Poggibonsi (Si) - AZIENDA MEZZI MECC. DEL PORTO DI LIVORNO - BIME SpA Pe-scia (Pt) - CRESAM S.Pietro a Grado (Pt) - AZIENDA PISANA TRASPORTI Pisa - ELECTRA Forlì - ASFALTI SINTEX Bologna - ARISTEA SpA Bolo-gna - SERENARI IMPIANTI Bologna - TECHNOFRIGO EUROPA Castel Maggiore (Bo) - CONSORZIO DELLA BONIFICA PARMIGIANA MOGLIASECCHIA Reggio Emilia - C.E.I.R. Ravenna - AZIENDA ELETTRICA MUNICIPALE IMOLA (Bo) - REGGIANE OFFICINE MECCANICHE ITALIANEReggio Emilia - SOC. SINCO Parma - PROT. EL. PONZI Parma - COOP. COSTRUTTORI Ferrara - DUTRAL Ferrara - IDEOMAT Modena - IFE SpAS. Nicolò (Pc) - ELETTROSISTEMI San Buceto (Ch) - AZ. MUN. SERV. SPEC. Tolentino (Mc) - FERRI S.r.l. Pescara -HONDA ITALIA INDUSTRIALESpA Chieti - CHEVRON OIL ITALIANA Roma - ELF Idrocarburi Roma - S.A.E.M. Roma - BANCO DI S. SPIRITO Roma - CEISUD Napoli - MAJORANONapoli - AZIENDA COLTIVAZIONE TABACCHI (Bn) - I.M.E.S. Manfredonia (Fg) - CARLI ANGELO Barletta (Ba) - DE SARLO Installazioni Sava (Ta) -F.LLI SCARNATI Rende (Cs) - VITALE SUD Lamezia Terme (Cz) - S.A.I.E. Manfredonia (Fg) - TRIPPINI Srl Crotone - SIREL Siracusa - MIGLIORE SO-NEPAR Palermo - LEDIFF srl Piano Tavola (Ct) - C.O.E.M. SpA Catania - ELETTROSICILIANA COSTRUZIONI Catania - F.LLI BRIGUGLIO Messina- CAVEDIL Catania - ELFIM Messina - STRANO SpA Catania - COEMI Siracusa - DI PIETRO SpA Cagliari - COM ELECTRIC Oristano - GRASSETTOCOSTRUZIONI Diga sul Tirso (Or) - RACCA Elettrof. Ind.li Cagliari - VANACORE fornit. elett. Sassari
PRINCIPALI CLIENTI ESTERI:
MAKSAN COMPANY Nicosia, CYPRUS - HELLENIC SUGAR INDUSTRY, GREECE - E.K.H.M. Thessaloniki, GREECE - E.G. LAROS & CO. E.E.Athens, GREECE - S. AIVAZIDIS S.A. Thessaloniki, GREECE. Important installation on Greece: GREEK RAILWAY COMPANY, EGNATIA ROAD &PATHE ROAD, ATHENS 2004/OLIMPIC GAMES COMMITTEE. - TELECOMMUNICATIONS COMPANY - Ets. Ch. FOCQUET & Cie SA-NV - Vilvoorde,BELGIUM - S.T.E.G. Societè Tunisienne de l'Electricitè et du Gaz Tunis, TUNISIE - ENEL Enterprise National Des Industries Electrotechniques Alger,ALGERIE - GENERAL WIRES AND ELECTRICAL PRODUCTS Benghasi, LYBIA - SCECO WEST Jeddah, SAUDI ARABIA - SCECO SOUTH Jeddah,SAUDI ARABIA - S.E.M.A.C.O.M. Jeddah, SAUDI ARABIA - ELECTRICAL WORKS AND MAINTENANCE Jeddah, SAUDI ARABIA - HESHAM EN-TERPRISES Jeddah, SAUDI ARABIA - AL-ARABI Riyad, SAUDI ARABIA - ELECTRIC HOUSE Jeddah, SAUDI ARABIA - AL ZARQUA ELECTRICITYJeddah, SAUDI ARABIA - NSRE AL JAZIRA Jeddah, SAUDI ARABIA - SALEM M. ALGUTHMI EST. - Jeddah, SAUDI ARABIA - ALKOMED Manama,BAHRAIN - AlHUSSAINI EST. Taiz, YEMEN - E.E.L.P.A. - E.R.E.SA. Asmara, ETHIOPIA - F.I.P. S.A. Fabrique Ivorienne de Parquet, IVORY COAST -EUROLATINA COMERCIAL C.A. Caracas, VENEZUELA - A.R.K.O. s.r.o. Kocice, SLOVENSKÁ REPUBLICA - NIYA Engineering LTD - G.R.A. Kaduna,NIGERIA - N.E.P.A - National Electric Power Authority - NIGERIALAMYA - AL-JAZERAH EST Riyadh, SAUDI ARABIA - ELIN SEILBAHNTECHNICKGmbh & Co Kg Innsbruck, AUSTRIA - COCA COLA BOTTLING Tirana, ALBANIA - MARCHIOL d.o.d. Nova Gorica, SLOVENIJA - EXIMET TRAFO LTDPraha, CZECH REPUBLIC - CES - Centrum Elektroniki Stosowanej Krakow, POLAND - KOPEX SA. Katowice, POLAND - ELEKTROPRIVREDASRBJIE Lazarevac, SRBJIE - WESTPAC INTERNATIONAL LTD Dublin, IRELAND - SYRIAN GAS COMPANY, SYRIA - SYRIAN PETROLEUM COM-PANY, SYRIA - LEMI TRAFO, BULGARIA - PARKMORE SWITCHGEAR LTD, IRELAND - ISMET AG Schwenningen, GERMANY - TALBERGS LTDRiga, LATVIA
da pag 12 a III di copert :Layout 1 8-11-2011 15:38 Pagina 6
AZIENDA CERTIFICATA DA DNV=UNI EN ISO 9001:2008=
COMPANY CERTIFIED BY DNV=ISO 9001:2008=
Elettromeccanica Piossasco S.r.l.Via Berchet, 22/24 - 10045 PIOSSASCO (TO) Italy
Tel. ++39 011.904 21 32 / 33 - Fax ++39 011.906 54 82
[email protected] - www.elpitalia.com
Elettromeccanica Piossasco nel mondo
FOREIGN VENDORS - DISTRIBUTORS
PRINCICIPAL COUNTRY WITH LOCAL AGENT OR DISTRIBUTOR:
AUSTRIAGERMANYFRANCECZECH REPUBLICBELGIUMPOLANDRUMANIAGREECENORWAYSWEDENUKRAINE
YEMENTUNISIELIBYASAUDI ARABIAUNITED ARAB EMIRATESGHANACONGOTANZANIAANGOLAKENYANIGERIA