Thought Technology Ltd.Thought Technology Ltd.
Heart Rate Variability Suite
• Welcome
• Introductions
• Handouts
Heart Rate Variability Suite
• Welcome
• Introductions
• Handouts
Online Course - Lesson 1
Online Course - Lesson 1
Thought Technology Ltd.Thought Technology Ltd.
RESONANT FREQUENCY• Start at a rate•Bring them down to frequency•Look at Low Frequency and see more power at that rate•That rate is what causes rf to occur.
RESONANT FREQUENCY• Start at a rate•Bring them down to frequency•Look at Low Frequency and see more power at that rate•That rate is what causes rf to occur.
Course ParticipantsCourse Participants
Thought Technology Ltd.Thought Technology Ltd.
BioGraph Infiniti componentsThat help to do this work
• Breathing Pacer• What the software can do • Pulling out the Data and reporting• Using Richard Barwell’s Software
BioGraph Infiniti componentsThat help to do this work
• Breathing Pacer• What the software can do • Pulling out the Data and reporting• Using Richard Barwell’s Software
Course ParticipantsCourse Participants
BIOFEEDBACK FOUNDATION OF EUROPEThe Foundation for Learning
Typical Encoders• Sampling rates
– ProComp Infiniti•8 inputs•A-B: 2048 Hz•C-H: 256 Hz
– ProComp 2•2 inputs (built in EEG in A)•A-B: 256 Hz•C-D: 32 Hz
Thought Technology Ltd.Thought Technology Ltd.EKG Sensor PlacementEKG Sensor Placement
Thought Technology Ltd.Thought Technology Ltd.Lesson 1Lesson 1
Thought Technology Ltd.Thought Technology Ltd.Respiration - SensorsRespiration - Sensors
Thought Technology Ltd.Thought Technology Ltd.EKG SensorsEKG Sensors
Thought Technology Ltd.Thought Technology Ltd.
BioGraph InfinitiBioGraph Infiniti
BioGraph InfinitiBioGraph Infiniti
• Need version 5.1
Thought Technology Ltd.Thought Technology Ltd.
BioGraph InfinitiBioGraph Infiniti
BioGraph InfinitiBioGraph Infiniti
• Need version 5.1
Thought Technology Ltd.Thought Technology Ltd.Respiration PacerRespiration Pacer
• The respiration pacer was designed to do the following…………..in notes from F1
Thought Technology Ltd.Thought Technology Ltd.Respiration PacerRespiration Pacer
• Paul Lehrer likes to use EZ-Air.
Thought Technology Ltd.Thought Technology Ltd.OPEN DISPLAYOPEN DISPLAY
• Paul Lehrer likes to use EZ-Air. He writes down information and does NOT use the tools developed for him at this time
Thought Technology Ltd.Thought Technology Ltd.SCRIPTSCRIPT
• Paul Lehrer likes to use EZ-Air. He writes down information and does NOT use the tools developed for him at this time
Thought Technology Ltd.
Questions?
Lesson 1Lesson 1
Thought Technology Ltd.Thought Technology Ltd.OPEN DISPLAYOPEN DISPLAY
Thought Technology Ltd.Thought Technology Ltd.SCRIPT DATASCRIPT DATA
Thought Technology Ltd.Thought Technology Ltd.SCRIPTSCRIPT
• Paul Lehrer likes to use EZ-Air. He writes down information and does NOT use the tools developed for him at this time
Thought Technology Ltd.Thought Technology Ltd.SCRIPTSCRIPT
• Breathing is slowly slowly slowly slowed down. This would be Didier’s prefered approach to setting up a script.
Thought Technology Ltd.Thought Technology Ltd.SCRIPTSCRIPT
• Breathing is slowly slowly slowly slowed down. This would be Didier’s prefered approach to setting up a script.
Thought Technology Ltd.Thought Technology Ltd.SCRIPTSCRIPT
• Magnitude of the peak frequency
Thought Technology Ltd.Thought Technology Ltd.SCRIPTSCRIPT
• Magnitude or amplitude of the peak frequency wherever it is, NOT in the LF frequency only.
Thought Technology Ltd.Thought Technology Ltd.SCRIPTSCRIPT
• Three values that Paul Lehrer uses
• Indication that pulse transit time
Thought Technology Ltd.Thought Technology Ltd.SCRIPTSCRIPT
• Magnitude or amplitude of the peak frequency wherever it is, NOT in the LF frequency only.
Thought Technology Ltd.Thought Technology Ltd.
QuestionsQuestions
Lesson 1Lesson 1
Thought Technology Ltd.Thought Technology Ltd.SCRIPTSCRIPT
Negative In Phase Positive
-180 0 degrees +180
Thought Technology Ltd.Thought Technology Ltd.PHASEPHASE
Negative In Phase Positive
-180 0 degrees +180
Thought Technology Ltd.Thought Technology Ltd.PHASEPHASE
BLOOD PRESSURE & CO2 AND O2
Thought Technology Ltd.Thought Technology Ltd.PHYSICAL
DIFFERNCESPHYSICAL
DIFFERNCES
RESONANT FREQUENCY WILL CHANGE WITH SIZE AND SHAPE OF CHILD
ADULT CHILD DIFFERENCES
SPORTY AS LESS SPORTY
HRV FOR CHILDREN
Thought Technology Ltd.Thought Technology Ltd.Respiration PacerRespiration Pacer
Options in Infiniti
• 1. Seconds
• Breath for a length of time
• 2. Percentages
• Percentage of time at a rate
• Article on breathing and meditation
Thought Technology Ltd.Thought Technology Ltd.
Event LabelsEvent Labels
Options: Event LabelsOptions: Event Labels
• Set event labels here. Event labels can be used to mark data while recording as a reminder of what was happening in the session
Thought Technology Ltd.Thought Technology Ltd.Event LabelsEvent Labels
Thought Technology Ltd.Thought Technology Ltd.Event Marker LabelsEvent Marker Labels
• Press CONTROL AND THE LETTER OR THE NUMBER
Thought Technology Ltd.Thought Technology Ltd.
Select a Client & Session
Select a Client & SessionDatabaseDatabase
Thought Technology Ltd.Thought Technology Ltd.Replay Session Replay Session
Thought Technology Ltd.Thought Technology Ltd.
Confidential ModeConfidential Mode
Database: selecting a clientDatabase: selecting a client
• From the left hand column select a client
• This client list is in confidential mode, to remove confidential mode, go to options, and uncheck it
Thought Technology Ltd.Thought Technology Ltd.
Selecting a SessionSelecting a Session
Database: selecting a recorded sessionDatabase: selecting a recorded session
• Select a recorded session from the right hand column
• Note that the type of session is listed under “Type”
Thought Technology Ltd.Thought Technology Ltd.
Replay SessionReplay Session
Database: Replay SessionDatabase: Replay Session
• With a client and recorded session selected, click on Replay Session
• Select the desired channel set and screens and click on OK.
Thought Technology Ltd.Thought Technology Ltd.
Select ScreensSelect Screens
Database: Selecting ScreensDatabase: Selecting Screens
• From picture mode you can see captures of the different screens. Note that some screens are two monitor (one screen for clinician, the other for client)
Thought Technology Ltd.Thought Technology Ltd.Replay Session Replay Session
Thought Technology Ltd.Thought Technology Ltd.Replay Session Replay Session
Thought Technology Ltd.Thought Technology Ltd.Left and Right AxesLeft and Right Axes
Thought Technology Ltd.Thought Technology Ltd.Screen #1Screen #1
Thought Technology Ltd.Thought Technology Ltd.ArtifactsArtifacts
Thought Technology Ltd.Thought Technology Ltd.
Screen AnatomyScreen Anatomy
Replay Mode: Heart Rate Variability Training ScreenReplay Mode: Heart Rate Variability Training Screen
• The training screen contains a number of graphs (bar and line), a frequency analysis, an epoch graph, sound, and a couple of animations.
Thought Technology Ltd.Thought Technology Ltd.
64 Seconds for FFT64 Seconds for FFT
Replay Mode: Heart Rate Variability Training ScreenReplay Mode: Heart Rate Variability Training Screen• Note that the frequency calculations will not come into effect before 64 seconds of data have been recorded. Before this point, the values are not valid and thus are not shown
Thought Technology Ltd.Thought Technology Ltd.
Replay Mode ControlsReplay Mode Controls
Replay Mode: Control MenuReplay Mode: Control Menu
• Press the Green Arrow to begin (Play)
• Press the Red Square to Stop
• Press the two Yellow Rectangles to Pause
• Press the numbered buttons to move through screens
Thought Technology Ltd.Thought Technology Ltd.
Time ScaleTime Scale
Replay Mode: Time ScaleReplay Mode: Time Scale
• To change the time scale, click on the drop down time menu and select your desired time scale
• Note that only line graphs will reflect this change
Thought Technology Ltd.Thought Technology Ltd.
Line GraphLine Graph
Replay Mode: Line GraphReplay Mode: Line Graph
• This line graph shows three different signals in different colours
•The signals are identified by the colours and labels above the graph
Thought Technology Ltd.Thought Technology Ltd.
Respiration PacerRespiration Pacer
Replay Mode: PacerReplay Mode: Pacer
• The breathing pacer allows the client to follow a pacer during respiration. Follow the ball up on inhale, and down on exhale
Thought Technology Ltd.Thought Technology Ltd.
Pacer SettingsPacer Settings
Replay Mode: PacerReplay Mode: Pacer• The pacer can be modified to virtually any respiration rate: right click on the instrument and select “Edit Pacer Settings”
• A box appears and it is here that you can modify the settings
Thought Technology Ltd.Thought Technology Ltd.
F1 Help At All TimesF1 Help At All Times
Replay Mode: F1 Help MenuReplay Mode: F1 Help Menu
• At any time press F1 to bring up a topic specific help menu
• You can also search topics in the left hand column
Thought Technology Ltd.Thought Technology Ltd.
AnimationsAnimations
Replay Mode: AnimationsReplay Mode: Animations
• Animations are to give visual feedback
• Animations can be continuous and move (circular or linear), or can be on or off (binary)
Thought Technology Ltd.Thought Technology Ltd.
Bar GraphsBar Graphs
Replay Mode: Bar GraphsReplay Mode: Bar Graphs• These bar graphs are set to an auto scale (continuously variable) and have thresholds (automatic thresholds)
• A small line graph beneath the bar graphs shows the raw signal
Thought Technology Ltd.Thought Technology Ltd.
FFT – Only after 64 secs
FFT – Only after 64 secs
Frequency Analysis (FFT)
Graph blank for first 64 seconds
Frequency Analysis (FFT)
Graph blank for first 64 seconds
Thought Technology Ltd.Thought Technology Ltd.
FFT – 2 DimensionsFFT – 2 Dimensions
Replay Mode: Frequency Analysis (FFT)Replay Mode: Frequency Analysis (FFT)
• The FFT (Fast Fourier Transformation) is a Frequency Analysis of the EKG IBI signal
• Note that the peak frequency changes colour for easy identification
Thought Technology Ltd.Thought Technology Ltd.
Epoch GraphEpoch Graph
Replay Mode: Epoch GraphReplay Mode: Epoch Graph
• This Epoch Graph can have both bar and line graphs (only bar shown below) and shows progress through a session (updates every 20 seconds)
• The vales are colour labeled and the last values are also shown as a numeric value at the top of the graph
Thought Technology Ltd.Thought Technology Ltd.
Numeric DisplayNumeric Display
Replay Mode: NumericReplay Mode: Numeric
• The numeric instrument simply shows the numerical value of the current statistic
• Note that the number is often dampened (averaged or slowed) to ensure that it is easily readable
Thought Technology Ltd.Thought Technology Ltd.Light and Tone
FeedbackLight and Tone
Feedback
Thought Technology Ltd.
Lesson 1 Review
• Thanks
• Any Questions?• Homework for Lesson 1• Date & Time for Lesson 2
Lesson 1 Wrap UpLesson 1 Wrap Up
Thought Technology Ltd.Thought Technology Ltd.
QuestionsQuestions
Lesson 1Lesson 1