NOTES:
(1) ALL LOW VOLTAGE SIGNAL WIRING SHALL BE 18-GAUGE MINIMUM. THE MINIMUM INDUCTIVE LOAD (LOCK) POWER WIRE GAUGE SHALL BE DETERMINED PER THE SDC WIRE GAUGE CHART. ALL WIRING (SINGLE OR MULTI-CONDUCTOR) SHALL BE COLOR CODED WITHOUT SPLICES. A MINIMUM OF TWO SPARE CONDUCTORS IS RECOMMENDED.
(2) SPECIFY VOLTAGE WHEN ORDERING PRODUCTS. VOLTAGE IS NOT SPECIFIED ONTHIS WIRE DIAGRAM, BE SURE ALL PRODUCTS ARE VOLTAGE COMPATIBLE.
(3) ALL WIRING MUST CONFORM TO NATIONAL, STATE AND LOCAL CODES.
(4) ALWAYS CONSULT WITH THE AUTHORITY HAVING JURISDICTION (AHJ) BEFORE INSTALLATION.
(5) WHERE REQUIRED BY CODE, CONNECT FAILSAFE SYSTEMS TO THE LOCAL FIRE LIFE SAFETY SYSTEM FOR EMERGENCY RELEASE.
(6) DOOR POSITION SWITCHES SHOWN WITH THE DOOR CLOSED
Solution #7 - Single Door Delayed Egress
Delayed Egress Door
Single Delayed Egress EMLock w/ Remote Annunciator Panel & Remote Bypass
- -- Page 1 of
-
© Security Door Controls
ACMains
(3) COND / 14 AWG
FACTORY INSTALLED JUMPER(REMOVE ONLY IF FIRE ALARM
INTERFACE IS CONNECTED)
VOLTAGE SELECTIONSWITCHES(SET FOR 24VDC)
TO 120VAC PRIMARYVOLTAGE CONNECTION
Battery InputTerminals
DC Voltage Output
Terminals
24 12
+ - + - C
602RF
(8) COND
1511SExitCheck® w/
EA100 Exit Annunciator
602RFPowerSupply
(8) COND**Single Lock Application
(5) COND
PROJECT NAME:
DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:
SO NO.: REVTITLE:-801 Avenida Acaso
Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861www.sdcsecurity.com
NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR ITS CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN WHICH THE EQUIPMENT IS INSTALLED AND OPERATED. ALL WIRING MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES FOR CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.
C NC- + - + NC NONO C C NC NO CNO C NO C NO C NO C NC NO C NC
[ BAS ][ DPS ][RESET][RM TRIG] [REX][RED RLY][GRN RLY][ LOCK ][ FP ][ PWR ]J6
J7
J2
[IBO][EXT SPKR]
UP
DNCOM
UP
DNCOM
UP
DNCOM
UP
DNCOM
A1
A3A2
+-PWR
RED
YELGRN
RTNRED
YELGRN
RTNRED
YELGRN
RTN
1234
RED
YELGRN
RTN
BLK
RED
GRN
BLUO
RG
WH
T
GRN - SECUREYEL - ALARM RED - UNLOCKED OFF - BYPASS
AUDIBLESHUNT
ACCESS
ONOFF
BLK – LED COM (-)GRN LED (+)RED LED (+)
YEL
YELWHT
WHT
GRN - SECUREYEL - ALARM RED - UNLOCKED OFF - BYPASS
Keep Closed
To Unlock
CloseTo
OverrideUnlock
PatientProtection
System(Optional - By Others)
To Patient Protection
System(3) COND
1511S ExitCheck® Delayed Egress EMLock®
EA100
TCC Control Panel
101-PAM
PUSH UNTIL ALARMSOUNDS. DOOR CAN BEOPENED IN 15 SECONDS.
MechanicalLatching Exit Device
101-PAMAnnunciator
Panel(Access/Bypass)
TCC SeriesDesktopConsole
(Access/Bypass/Reset)
REMOTE CONTROL DESK OPTIONS
Method of OperationDoor normally closed and secured with Delayed Egress unit and latching mechanical exit bar.Authorized Access – Access from outside not allowed.Authorized Egress – Desk personnel may allow authorized egress by pressing appropriate button on desk console or pressing Access button on 101-PAM wall plate.Unauthorized Egress – When an unauthorized egress is attempted, the Delayed Egress unit goes into alarm and announces warnings. Alarm warning will also be provided by siren in 101-PAM. The person attempting to exit is delayed for 15 seconds (or 30 seconds by AHJ) by the Delayed Egress unit. At end of 15 second period, the Delayed egress Emlock releases allowing person to exit by pressing exit bar push pad. The Delayed egress unit will continue to alarm until manually Reset.Fire/Emergency - Power supply to be connected the Fire/Emergency system to turn Off power supply and Unlock the Delayed Egress Emlock. Free egress allowed by pushing on exit bar pad.