Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia, Kuala Lumpur.
LAMPIRAN A (Rev. 21 JUL 2014)
Muka surat 1 dari 15
Senarai Pembekal Sistem Kekuda Bumbung Bil. 1/2014
1. Timber Truss
No Name and Address of System Provider
Material Properties Type of Bracings
Protective Coating for
Metal Connectors
Approval Status
1 MITEK ASIA SDN. BHD.
Lot 15, Jalan Sultan Mohamad 5
Kawasan Peindustrian Bandar Sultan Sulaiman
42000 Pelabuhan Kelang, Selangor
Tel : 03 – 3176 7473 Fax: 03 – 3176 7640
Hardwood Timber
Strength Group SG1-SG4
Toothed Metal Connectors
Min.Ult. Tensile 320 MPa Min.Yield Stress 250 MPa
Steel Brace
(Speedbrace) conforming to AS
4440-1997
With MiTek 35 x 2.8 nails
Hot-dipped Zinc
coated or Aluminium / Zinc
coated
Temporary Suspended
Effective on
26 Mei 2014
2 MULTINAIL ASIA SDN. BHD.
Lot.15, Jalan Bs 7/20
Taman Industries Bukit Serdang 43300 Seri Kembangan, Selangor
Tel : 03 – 8942 3099
Fax: 03 – 8942 5686
Hardwood Timber
Strength Group SG1-SG4
Toothed Metal Connectors
Min.Ult. Tensile 320 MPa Min.Yield Stress 250 MPa
Steel Brace
(Speedbrace) conforming to AS
4440-1997
With Multinail 35 x 3.0 flat head
nails
Hot-dipped Zinc
coated or Aluminium / Zinc
coated
3 NAIL-PLATE SDN. BHD.
13-A, Jalan SS 14/1A
47500 Subang Jaya, Selangor
Tel : 03 – 5631 9698 Fax: 03 – 5637 2433
Hardwood Timber
Strength Group SG1-SG4
Toothed Metal Connectors
Min.Ult. Tensile 320 MPa
Min.Yield Stress 250 MPa
Timber brace
(Hardwood)
SG1-SG4 conforming to
Australian Standard
Hot-dipped Zinc coated or
Aluminium / Zinc
coated
Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia, Kuala Lumpur.
LAMPIRAN A (Rev. 21 JUL 2014)
Muka surat 2 dari 15
Senarai Pembekal Sistem Kekuda Bumbung Bil. 1/2014
2. Cold Formed Steel Truss
No Name and Address of System Provider
Material Properties Approved Fastener
a) Types b) Head Marking (Class)
Minimum Corrosion Protection
Approval Status
1 UAC STEEL SYSTEM SDN.
BHD.
Lot 34 Jalan Beliong 15/11
Section 15, P.O. Box 7796
40000 Shah Alam, Selangor
Tel : 03 – 5513 1133
Fax: 03 – 5511 3699
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a) ASTeks
Red Point
(Self-drilling Screws)
b)A2S (Class 2)
Hot-dipped Zinc Coated
or
Aluminium
/ Zinc
Coated
2 NS BLUESCOPE LYSAGHT
MALAYSIA SDN. BHD.
6,Persiaran Kemajuan Seksyen 16
P.O.Box 2222, Pusat Bisnes Bukit
Raja 40800 Shah Alam, Selangor
Tel : 03 – 5520 6600
Fax: 03 – 5520 6601
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a) ASTeks Red Point
(Self-drilling
screws)
b)A2S (Class 2) &
A3S (Class 3)
Hot-dipped
Zinc Coated or
Aluminium
/ Zinc Coated
3 LITEFRAMES SDN. BHD.
190, Jalan Nilai 3/18
Nilai 3 Industrial Park 71800 Nilai, Negeri Sembilan
Tel : 06-799 2622
Fax: 06-799 5122
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a) ASTeks
Red Point (Self-drilling
screws)
b)A2S (Class 2) &
A3S (Class 3)
Hot-dipped
Zinc Coated
or Aluminium
/ Zinc
Coated
Conditional Approval
(Approval by CKASJ as
per project basis)
Effective on 16 June
2009
4 TONG YONG METAL SDN.
BHD.
Lot 5781 & 5782 Taman Selamat Alma
14000 Bukit Mertajam Seberang Perai Tengah
Pulau Pinang
Tel : 04 – 552 3086/ 3089 / 3090 Fax: 04 – 552 3087
Rectangular Hollow Section, RHS (with
flat surfaces) & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 0.6mm : Main Truss Member (RHS)
Min. Thickness 1.0mm : Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a) MKT
Hexagon Washer Head
(Self-drilling Screws)
b)M2 (Class 2) & M3(Class 3)
Hot-dipped
Zinc Coated
or Aluminium
/ Zinc Coated
Conditional Approval
(Approval by CKASJ as
per project basis)
Effective on 30 October
2013
Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia, Kuala Lumpur.
LAMPIRAN A (Rev. 21 JUL 2014)
Muka surat 3 dari 15
Senarai Pembekal Sistem Kekuda Bumbung Bil. 1/2014
2. Cold Formed Steel Truss
No Name and Address of System Provider
Material Properties Approved Fastener
a) Types b) Head Marking (Class)
Minimum Corrosion Protection
Approval Status
5 LOTEZ ENGINEERING SDN.
BHD.
B 7-3-2 Block B, Megan Corporate
Park
Taman Desa Petaling
57100 Kuala Lumpur
Tel : 03 – 9057 6691/ 6695
Fax: 03 – 9057 6617
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a)Ocean DX 520 HO C2
(Self-drilling
Screws)
b)DX (Class 2)
Hot-dipped
Zinc Coated or
Aluminium
/ Zinc
Coated
Temporary Suspended
Effective on
30 October 2013
6 KEMUNING STRUCTURES
SDN. BHD.
Lot 3801, 6 1/4 Miles, Seksyen 32 Jalan Klinik, Bukit Kemuning
40460 Shah Alam, Selangor
Tel : 03 – 5162 1688 Fax: 03 – 5162 4286
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a)Ocean
RG2-DX3 4.8-16 (Self-drilling
Screws)
b)DX(Class 2)
Hot-dipped
Zinc Coated
or Aluminium
/ Zinc
Coated
7
VISAGE INDUSTRIES SDN.
BHD.
Plot 162A, Lrg Perindustrian Bukit
Minyak 11
Kawasan Perindustrian Bukit Minyak MK 13
14100 Bukit Minyak, Penang
Tel : 04-508 1191 Fax: 04-508 2191
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a)MKT (Self-drilling
Srews)
b)M2 (Class 2) &
M3(Class 3)
Hot-dipped
Zinc Coated or
Aluminium
/ Zinc Coated
Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia, Kuala Lumpur.
LAMPIRAN A (Rev. 21 JUL 2014)
Muka surat 4 dari 15
Senarai Pembekal Sistem Kekuda Bumbung Bil. 1/2014
2. Cold Formed Steel Truss
No Name and Address of System Provider
Material Properties Approved Fastener
a) Types b) Head Marking (Class)
Minimum Corrosion Protection
Approval Status
8 COOLDEC METAL
INDUSTRIES SDN. BHD.
8 & 10, Jalan Pala 10, Kawasan
Industri Ringan Permatang Tinggi,
14000 Bukit Mertajam, Penang
Tel : 04-5885 198 / 398
Fax: 04-5889 598
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a)MKT (Self drilling
Screw)
b)M2(Class 2)
Hot-dipped
Zinc Coated or
Aluminium
/ Zinc
Coated
9 AJIYA STI SDN. BHD.
No.6, Jalan PPU 3
Taman Perindustrian Puchong Utama
85000 Puchong, Selangor
Tel : 03 – 5121 0011 Fax: 03 – 5121 0111
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a) Fast Mark
(Self-drilling Screws)
b)F2(Class 2)
Hot-dipped
Zinc Coated
or Aluminium
/ Zinc
Coated
Temporary Suspended
Effective on
22 May 2013
10 BRICKWELL ENGINEERING
SDN. BHD.
Lot 4135-4137
Kaw. Perindustrian Pengkalan
Chepa 16100 Kota Bharu, Kelantan.
Tel : 09 – 771 3677 / 3678
Fax: 09 – 771 3670
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a) Fast Mark DS 520 HO
(Self-drilling
Screws)
b)F2(Class 2)
Hot-dipped
Zinc Coated or
Aluminium
/ Zinc Coated
11 SUPERSPAN SDN. BHD.
No. 22, Jalan Batai Laut 4
Kawasan 16, Taman Intan
41300 Klang, Selangor Darul Ehsan
Tel : 03 – 3344 5748 Fax: 03 – 3343 0724
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a) ASTeks
Red Point
(Self-drilling
Screws)
b)A2S(Class 2)
Hot-dipped
Zinc Coated
or
Aluminium
/ Zinc Coated
Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia, Kuala Lumpur.
LAMPIRAN A (Rev. 21 JUL 2014)
Muka surat 5 dari 15
Senarai Pembekal Sistem Kekuda Bumbung Bil. 1/2014
2. Cold Formed Steel Truss
No Name and Address of System Provider
Material Properties Approved Fastener
a) Types b) Head Marking (Class)
Minimum Corrosion Protection
Approval Status
12 ECOSTEEL SDN. BHD.
Lot 825, Block 7 Demak Laut Industrial Park
93050 Kuching, Sarawak
Tel : 082 – 439 368
Fax: 082 – 433 063
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a)ASTeks Red Point
A 12-14x20
HWF (Self-drilling
Screws)
b)A2S (Class 2) &
A3S (Class 3)
Hot-dipped
Zinc Coated or
Aluminium
/ Zinc
Coated
13 LAVENDA BUILDING
SYSTEM SDN. BHD.
No. 2, Jalan Mandolin 33/5 Premier Industrial Park, Seksyen 33
40400 Shah Alam, Selangor
Tel : 03-5614 3670 Fax : 03-5614 3671
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a)TENN
(Self-drilling
Screws)
b)F2(Class 2 &
F3(Class 3)
Hot-dipped
Zinc Coated
14 MULTI RESOURCES SDN.
BHD.
Lot 1311, Pending Industrial Estate
P.O Box 1663
93734 Kuching, Sarawak Tel : 082-331 267
Fax : 082-487 301
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a)MTEK Screw #12-14x 23mm
(Self-drilling
Screws)
b)MT(Class 3)
Hot-dipped
Zinc Coated or
Aluminium
/ Zinc Coated
15 BRISTEEL CORPORATION
SDN. BHD.
7A, Lorong Anggur
Visa Industrial Estate Off Jalan Kolombong
88450 Kota Kinabalu, Sabah Tel : 088-382 811 / 15
Fax : 088-382 813
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member & Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a)MKT
DS 520 HO
DSF620HO (Self-drilling
Screws)
b)M2(Class 2) &
M3(Class 3)
Hot-dipped
Zinc Coated
or
Aluminium / Zinc
Coated
Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia, Kuala Lumpur.
LAMPIRAN A (Rev. 21 JUL 2014)
Muka surat 6 dari 15
Senarai Pembekal Sistem Kekuda Bumbung Bil. 1/2014
2. Cold Formed Steel Truss
No Name and Address of System Provider
Material Properties Approved Fastener
a) Types b) Head Marking (Class)
Minimum Corrosion Protection
Approval Status
16 HAI-POINT STEEL SDN.
BHD.
No. 593, Jalan Pinang Jaya
Bukit Pinang
06200 Kedah Darul Aman
Tel : 04-7142487, 7143487,
7144487, 7146487, 7176388
Fax : 04-7142368
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a)MKT DSM516 HO
#10x5/8
(Self-drilling Screws)
b) M2(Class 2)
Hot-dipped
Zinc Coated or
Aluminium
/ Zinc
Coated
17 NS BLUESCOPE LYSAGHT
SABAH SDN. BHD.
Lorong Kurma, Off Jalan Kolombong
88450 Kota Kinabalu, Sabah
Tel : 088-445 161 Fax : 088-421 178
: 088-421178 : 088-421178
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a)ASTeks
Red Point A3#12-14x
20HxW
(Self-drilling Screws)
b)A3(Class 3)
Hot-dipped
Zinc Coated
or Aluminium
/ Zinc
Coated
18 CITY TOP ENTERPRISE SDN.
BHD.
Lorong Burung Keleto
Mile 5 ½, Inanam, Jalan Tuaran 88450 Kota Kinabalu
Sabah
Tel : 088-423 333, 088-429 199 Fax : 088-429 200, 088-436 617
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member & Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a) ASA Fastener
DX 620 HO CR
(Self-drilling Screws)
b)PX(Class 3)
Hot-dipped Zinc Coated
or
Aluminium / Zinc
Coated
19 SRT BUILDING SYSTEMS
SDN. BHD.
35 & 35A
Lintasan Perajurit 17 Taman Perdagangan &
Perindustrian Ipoh 31400 Ipoh
Perak Darul Ridzuan
Tel : 05-542 3041 Fax : 05-542 3042 & 05-542 3043
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member & Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a)MKT
Hexagon Washer
Head #10-24x16 mm
(Self-Drilling Screws)
b)M2(Class 2) & M3(Class 3)
Hot-dipped
Zinc Coated
or
Aluminium / Zinc
Coated
Conditional Approval
(Approval by CKASJ as
per project basis)
Effective on 23 January
2013
Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia, Kuala Lumpur.
LAMPIRAN A (Rev. 21 JUL 2014)
Muka surat 7 dari 15
Senarai Pembekal Sistem Kekuda Bumbung Bil. 1/2014
2. Cold Formed Steel Truss
No Name and Address of System Provider
Material Properties Approved Fastener
a) Types b) Head Marking (Class)
Minimum Corrosion Protection
Approval Status
20 NS BLUESCOPE LYSAGHT
(SARAWAK) SDN. BHD.
Lot 610, Section 66
Pending Industrial Area
P.O. Box 1007
93720 Kuching
Sarawak
Tel : 082-333 621 Fax : 082-483 486
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a)TENN DX Hexagonal
Wafer Head
(Self-drilling Screws)
b)J3(Class 3)
Hot-dipped
Aluminium / Zinc
Coated
21 YUNCO BUILDING SYSTEMS
SDN. BHD.
Lot 712, Block 7, Demak Laut
Industrial Park 93050 Kuching
Sarawak
Tel : 082-432 880 Fax : 082-432 894
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member & Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a)ASTeks
Red Point
A2S 12-14x20 HWF
(Self-drilling
Screws)
b)A2S(Class 2)
Hot-dipped Zinc Coated
or
Aluminium / Zinc
Coated
22 COOLDEC INDUSTRIES SDN.
BHD.
No. 11759, Miles 3
Jalan Apas, Lorong Sri Mawar 91000 Tawau
Sabah
Tel : 089-911 375/175 Fax : 089-911 135/607
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member & Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a)Chin Well
DS-HO#10 x 5/8
(Self-Drilling Screws)
b) (Class 2)
Hot-dipped Zinc Coated
or
Aluminium / Zinc
Coated
23 ROLFOM INNOVATION SDN.
BHD.
No. 126, Jalan P/AM 1/1
Arab Malaysian Industrial Park 71800 Nilai
Negeri Sembilan
Tel : 06-799 7296 Faks : 06-799 5296
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member & Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a) Fast Mark
DS 520 HO
(Self-Drilling Screws)
b)F2(Class 2)
Hot-dipped Zinc Coated
or
Aluminium / Zinc
Coated
Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia, Kuala Lumpur.
LAMPIRAN A (Rev. 21 JUL 2014)
Muka surat 8 dari 15
Senarai Pembekal Sistem Kekuda Bumbung Bil. 1/2014
2. Cold Formed Steel Truss
No Name and Address of System Provider
Material Properties Approved Fastener
a) Types b) Head Marking (Class)
Minimum Corrosion Protection
Approval Status
24 HS HENG SENG METAL SDN.
BHD.
PT 1431, Seksyen 39
Kawasan Perindustrian Pengkalan
Chepa II
Mukim Kemumin
16100 Kota Bharu
Kelantan Darul Naim Tel : 09-773 6233, 09-773 0132,
09-773 0136
Faks : 09-773 6135
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a)ASTeks Red Point
(Self-drilling
Screws)
b)A2S(Class 2) &
A3S(Class 3)
Hot-dipped
Zinc Coated or
Aluminium
/ Zinc
Coated
25 JUARA STEEL SDN. BHD.
Lot 10463, Batu 5
Jalan Kampung Jawa
41000 Klang Selangor Darul Ehsan
Tel : 03-5161 8005
Faks : 03-5162 1372
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member & Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a)ASTeks
Red Point
(Self-drilling Screws)
b)A2S(Class 2) & A3S(Class 3)
Hot-dipped Zinc Coated
or
Aluminium / Zinc
Coated
26 ARI TIMUR (KB) SDN. BHD.
Lot 1306
Kawasan Perindustrian Pengkalan Chepa II
16100 Kota Bharu
Kelantan Tel : 09-774 5946
Faks : 09-774 6946
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a) Fast Mark
(Self-drilling Screws)
b)F2(Class 2)
Hot-dipped
Zinc Coated
or
Aluminium
/ Zinc
Coated
27 SUPER GLORY INDUSTRIES
SDN. BHD.
Lot 921, Blok 26, KLD
Tanjung Kidurong Road P.O. Box 1954
97000 Bintulu
Sarawak Tel : 086-251 119 / 086-251 441
Faks : 086-251 444
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member & Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a)ASTeks
Red Point
A2S 12-14x20 HWF
(Self-drilling
Screws)
b)A2S(Class 2)
Hot-dipped Zinc Coated
or
Aluminium / Zinc
Coated
Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia, Kuala Lumpur.
LAMPIRAN A (Rev. 21 JUL 2014)
Muka surat 9 dari 15
Senarai Pembekal Sistem Kekuda Bumbung Bil. 1/2014
2. Cold Formed Steel Truss
No Name and Address of System Provider
Material Properties Approved Fastener
a) Types b) Head Marking (Class)
Minimum Corrosion Protection
Approval Status
28 THUNG HING INDUSTRIAL
TRADING SDN. BHD.
Lot P.T 1351, Jalan Mohd Taib
Kawasan Industrian Sg. Choh
48000 Rawang
Selangor Darul Ehsan
Tel : 603 – 6099 9999
Faks : 603 – 6099 9922
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a) Ocean
#10-16X19 (Self-drilling
Screws)
b)DX(Class 2)
Hot-dipped
Zinc Coated or
Aluminium
/ Zinc Coated
29 6 CONNECTIONS SDN. BHD.
Lot PTD 12537, LB (2) Batu 19 Jalan Segamat
84900 Tangkak, Johor
Tel : 606 – 978 1107 Faks : 606 – 978 3153
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a)TENN
(Self-drilling Screws)
b)JX(Class 2)
Hot-dipped
Zinc Coated or
Aluminium
/ Zinc Coated
Temporary Suspended
Effective on
30 October 2013
30 MINE TECH GLOBAL
SERVICES (M) SDN. BHD.
Lot 3736, Kg. Labuhan, Kerteh
24300 Kerteh, Kemaman Terengganu
Tel : 609 – 826 3050
Faks : 609 – 826 4042
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member & Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a) Fast Mark
DS 520 HO
(Self-drilling Screws)
b)F2(Class 2)
Hot-dipped Zinc Coated
or
Aluminium / Zinc
Coated
Temporary Suspended
Effective on
26 Mei 2014
31 RONAS NIAGA ENTERPRISE
SDN. BHD.
Plot 7, Jalan PBR 33, Kawasan Perindustrian
Bukit Rambai,
75400 Melaka Tel : 06 – 351 5877
Fax : 06 – 351 6877
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a)TONG MUI
DS 520 (Self-drilling
Screws)
b)T.M(Class 2)
Hot-dipped
Zinc Coated
or
Aluminium
/ Zinc
Coated
Temporary Suspended
Effective on
26 Mei 2014
Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia, Kuala Lumpur.
LAMPIRAN A (Rev. 21 JUL 2014)
Muka surat 10 dari 15
Senarai Pembekal Sistem Kekuda Bumbung Bil. 1/2014
2. Cold Formed Steel Truss
No Name and Address of System Provider
Material Properties Approved Fastener
a) Types b) Head Marking (Class)
Minimum Corrosion Protection
Approval Status
32 DANCAST SDN. BHD.
Plot 18, 19, 20 & 21 Kawasan Perindustrian Bandar
Darul Aman
06000 Jitra, Kedah Darul Aman
Tel : 04 – 917 6437
Fax: 04 – 917 6324
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to 1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm then Min. Yield Stress 450 MPa
a)Fast Mark DS 520 HO
(Self-drilling
Screws)
b)F2(Class 2)
Hot-dipped
Zinc Coated
or
Aluminium
/ Zinc Coated
33 DUNGUN INTERGRADE
SDN. BHD.
Lot 6069, Batu 5,Jalan Paka, 23000 Dungun, Terengganu,
Terengganu Darul Iman
Tel : 09 - 8422710 Fax : 09 - 8422712
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate Min. Thickness 1.0mm : Main Truss Member
& Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a) Fast Mark
DS 520 HO (Self-drilling
Screws)
b)F2(Class 2)
Hot-dipped
Zinc Coated
or
Aluminium
/ Zinc
Coated
Temporary Suspended
Effective on
26 Mei 2014
34 INTECHMAN SDN. BHD.
No A21, Kawasan Industri Mara
(KIM)
KM 13 Off Jalan Batu Caves, 68100 Kuala Lumpur
Tel : 03 – 6186 2267
Faks : 03 – 6187 2267
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member & Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a)Fast Mark
DS 520 HO
(Self-drilling Screws)
b)F2(Class 2)
Hot-dipped Zinc Coated
or
Aluminium / Zinc
Coated
35 TECK GUAN STEEL SDN.
BHD.
No. 6, Jalan Cenderakasih,
Off Jalan Lintas, Kolombong, 88450 Kota Kinabalu, Sabah
Tel : 088-439955 Fax : 088-425135
C-Lipped Channel & Batten
Min. Thickness 1.2mm : Wall Plate
Min. Thickness 1.0mm : Main Truss Member & Bracing
Min. Thickness 0.5mm : Batten
For base metal thickness less than or equal to
1.2mm then Min. Yield Stress 550 MPa
For base metal thickness greater than 1.2mm
then Min. Yield Stress 450 MPa
a)ASTeks
Red Point
A2S 12-14x20 HWF
(Self-drilling Screws)
b)A2S(Class 2)
Hot-dipped
Zinc Coated
or
Aluminium / Zinc
Coated
Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia, Kuala Lumpur.
LAMPIRAN A (Rev. 21 JUL 2014)
Muka surat 11 dari 15
Senarai ini dikeluarkan oleh : Pengarah Kanan
Cawangan Kejuruteraan Awam, Struktur & Jambatan Jabatan Kerja Raya Malaysia
Tingkat 15, Centrepoint North
The Boulevard, Mid Valley City Lingkaran Syed Putra
59200 Kuala Lumpur
Pegawai untuk dihubungi : Ir. Hj. Mohd. Noor Azudin Mansor Tel: 03-9235 4650 E-mel: [email protected]
Ir. Mohd Zamri Abdullah Tel: 03-9235 4405 E-mel: [email protected] En. Abdullah Ab. Wahab Tel: 03-9235 4771 E-mel: [email protected]
En. Megat Kamarulzaman Mgt. Yusoff Tel: 03-9235 4774 E-mel: [email protected]
En. Mohd Rosdi Yusoff Tel: 03-9235 4776 E-mel: [email protected]
Untuk senarai terkini sila layari http:// www.jkr.gov.my
Muka surat 12 dari 15
GARIS PANDUAN BAGI REKABENTUK DAN PEMASANGAN
KEKUDA BUMBUNG PASANGSIAP
1. Keperluan Am
1.1 Setiap Kontraktor Utama yang ingin menggunakan sistem kekuda bumbung jenis Pre-
Fabricated Cold Formed Steel atau Pre-Fabricated Timber hendaklah membuat
permohonan kepada Pegawai Penguasa / Pengarah Projek dengan mengisi Borang
Permohonan Penggunaan Sistem Kekuda Bumbung (Lampiran C).
1.2 Pegawai Penguasa / Pengarah Projek akan memastikan bahawa Pembekal Sistem (System
Provider) yang dicadangkan oleh Kontraktor Utama adalah terdiri dari pembekal-pembekal
yang telah disenaraikan di dalam Senarai Pembekal Sistem Kekuda Bumbung (Lampiran
A). Senarai ini akan dikemaskini dari masa ke masa dan boleh diakses di laman web
www.jkr.gov.my pada ruangan Pengumuman.
1.3 Pegawai Penguasa / Pengarah Projek juga akan menyemak kelayakan Pemasang Bertauliah
(Accredited Installer) dengan menuntut setiap penamaan Pemasang Bertauliah
menyertakan surat asal perakuan dari Pembekal Sistem berkenaan.
1.4 Pegawai Penguasa / Pengarah Projek akan menyatakan persetujuan terhadap permohonan
Kontraktor Utama apabila semua keperluan yang telah ditentukan dalam garis panduan ini
telah dipatuhi serta yakin dengan kemampuan Pemasang Bertauliah dan Jurutera
Rekabentuk yang dicadangkan.
1.5 Pegawai Penguasa / Pengarah Projek akan mengemukakan satu (1) salinan Borang
Permohonan (Lampiran C) kepada Pengarah Kanan, Cawangan Kejuruteraan Awam,
Struktur & Jambatan, Jabatan Kerja Raya Malaysia, Tingkat 15, Centre Point
North, The Boulevard, Mid Valley City, Lingkaran Syed Putra, 59200 Kuala Lumpur untuk tujuan rekod.
1.6 Pegawai Penguasa / Pengarah Projek akan hanya membuat bayaran untuk pembekalan dan
pemasangan kekuda keluli bumbung berkenaan sesudah pihak Kontraktor Utama
mengemukakan kepada Pegawai Penguasa / Pengarah Projek perakuan siap yang
ditandatangani oleh Jurutera Professional yang berdaftar dengan Lembaga Jurutera
Malaysia (BEM). Perakuan tersebut mengesahkan bahawa pembuatan dan pemasangan
kekuda telah disiapkan dan kerja telah dibuat selaras dengan lukisan pembinaan dan
penentuan yang telah dikemukakan terdahulu.
Lampiran B
Muka surat 13 dari 15
2. Pengemukaan Dokumen Sokongan oleh Kontraktor Utama
2.1 Kontraktor Utama adalah dikehendaki untuk mengemukakan kepada Pegawai Penguasa /
Pengarah Projek dokumen-dokumen lain yang berkaitan selain dari Borang Permohonan
(Lampiran C) bagi menyokong permohonan beliau. Dokumen-dokumen lain yang
dimaksudkan itu ialah seperti berikut:
i) Pengiraan rekabentuk kekuda bumbung (bebanan servis M&E yang ditanggung oleh
struktur kekuda seperti air-conditioner ducting, dan lain-lain dimasukkan dalam
rekabentuk, jika berkenaan. Walaubagaimanapun, struktur kekuda tidak harus
direkabentuk untuk menanggung bebanan tangki air.
ii) Pengiraan rekabentuk untuk komponen kritikal (critical members).
iii) Pengiraan rekabentuk untuk perembat kekal (permanent bracing).
iv) Pengiraan rekabentuk bagi sambungan anggota kekuda (truss connection) spt.
fastener, L-bracket dan anchor-bolt.
v) Pengiraan rekabentuk untuk sokong kekuda (truss support) yang menggunakan wall
plate.
vi) Lukisan kerja yang disahkan (certified construction drawings) yang merangkumi
lukisan keseluruhan struktur kekuda, perincian pemasangan bagi perembat kekal,
sambungan anggota kekuda (termasuklah perincian sambungan yang melibatkan
penggantungan servis M&E, dll) dan sokong kekuda.
vii) Method Statement untuk kerja-kerja fabrikasi dan pemasangan.
viii) Program kawalan mutu dan pemeriksaan yang bakal dijalankan.
ix) Perakuan Jurutera Rekabentuk berhubung pematuhan keperluan kadar ketahanan
kebakaran sepertimana termaktub dalam Undang-Undang Kecil Bangunan Seragam
(UBBL) yang berkuatkuasa.
2.2 Semua dokumen-dokumen kejuruteraan yang dihasilkan dan dikemukakan kepada
Pegawai Penguasa / Pengarah Projek oleh Kontraktor Utama berhubung dengan kekuda
bumbung tersebut hendaklah disahkan, ditandatangani dan diturunkan mohor Jurutera
Professional oleh Jurutera Perekabentuk yang bertauliah.
2.3 Jurutera Perekabentuk yang boleh ditauliahkan untuk menjalankan kerja-kerja rekabentuk
dengan pengesahan pemasangan di tapak ialah jurutera yang berdaftar dengan Lembaga
Jurutera Malaysia (BEM) sebagai Jurutera Professional (Professional Engineer) dan
masih dibenarkan untuk menjalankan kerja-kerja kejuruteraan.
2.4 Kontraktor Utama dikehendaki untuk menyelia kerja-kerja pemasangan kekuda bumbung
tersebut serta memastikan kerja yang dihasilkan adalah terbaik dan keselamatan awam
adalah terjamin pada setiap masa.
Lampiran B
Cawangan Kejuruteraan Awam, Struktur & Jambatan CKASJ/SKB/1/2010
Ibu Pejabat JKR Malaysia, Kuala Lumpur
(Tandatangan Kontraktor Utama dan Cop Mohor)
(Alamat Perekabentuk)
(Nombor Pendaftaran LJM)
(Tandatangan Pembekal Sistem dan Cop Mohor)
Muka surat 14 dari 15
Permohonan Penggunaan Sistem Kekuda Bumbung :
Pre-Fabricated Cold Formed Steel Factory Fabrication
Pre-Fabricated Timber On-site Fabrication
A. Maklumat Asas Projek
i. Nama projek : ....................................................................................................................
....................................................................................................................
ii. No. Kontrak : ....................................................................................................................
iii. Nama dan Alamat : ....................................................................................................................
Kontraktor Utama .....................................................................................................................
....................................................................................................................
B. Maklumat Cadangan Sistem Kekuda
Adalah saya Kontraktor Utama projek ini memohon untuk menggunakan sistem kekuda pasangsiap
tersebut sebagaimana butiran di bawah :
i. Nama dan Alamat Pembekal Sistem : ..........................................................................................
......................................................................................................................
......................................................................................................................
ii. Nama dan Alamat Perekabentuk : ................................................................................................
......................................................................................................................
......................................................................................................................
iii. Nama dan Alamat Pemasang Bertauliah : ...................................................................................
......................................................................................................................
......................................................................................................................
(Sila sertakan Surat Perakuan Pemasang Bertauliah dari Pembekal Sistem)
C. Perakuan Kontraktor Utama
Adalah saya Kontraktor Utama projek ini yang memohon untuk menggunakan kekuda pasangsiap seperti
butiran di atas, mengakui bahawa saya adalah bertanggungjawab sepenuhnya terhadap pembekalan,
rekabentuk dan pemasangan kekuda pasangsiap tersebut.
Tarikh : ........................................... ............................................................
D. Perakuan Pembekal Sistem
Saya mengesahkan bahawa sistem kekuda syarikat kami dicadangkan untuk projek di atas mencapai segala
keperluan yang dinyatakan di dalam spesifikasi.
Tarikh : ........................................... ............................................................
Lampiran C
Muka surat 15 dari 15
ADDENDUM KEPADA SPESIFIKASI JKR (UNTUK PROJEK-PROJEK
YANG MASIH MENGGUNAKAN STANDARD SPECIFICATIONS FOR
BUILDING WORKS 2005)
1) Semua kerja rekabentuk, pembekalan dan pemasangan sistem kekuda bumbung keluli
(cold formed) hendaklah merujuk Spesifikasi JKR : Pre-Fabricated Cold Formed
Steel Roof Trusses (JKR 20601-0186-11). Dilampirkan muka hadapan spesifikasi
JKR 20601-0186-11.
2) Semua kerja rekabentuk, pembekalan dan pemasangan sistem kekuda bumbung kayu
hendaklah merujuk Spesifikasi JKR : Pre-Fabricated Timber Roof Trusses (JKR
20601-0190-12). Dilampirkan muka hadapan spesifikasi JKR 20601-0190-12.
3) Spesifikasi JKR 20601-0186-11 merupakan addendum kepada spesifikasi JKR :
Standard Specifications For Building Works 2005. Dilampirkan salinan surat edaran
bil.(30)dlm.JKR.CKASJ/02.500/030/LN/42 bertarikh 9 Januari 2012 untuk
pemakaian spesifikasi kepada klausa-klausa berkaitan dalam spesifikasi JKR :
Standard Specifications For Building Works 2005.
Lampiran D