RTD INCOTEST

Key advantages of RTD INCOTEST

RTD INCOTEST provides a reliable solution for a variety of applications.

• RTDINCOTESTenablesthedetectionofCUI(CorrosionUnderInsulation)andFAC(FlowAccelerated

Corrosion).

• Riseraveragewallthicknesscanbegaugedwithoutremovingmarinegrowth,neopreneorMonel.

• Non-contact‘dry’wallthicknessmeasurementscanbecarriedoutevenwithdirty,coatedroughand/orhigh

temperatureobject.

• TherobustdesignofRTDINCOTESTiselectrically,althoughnotintrinsicallysafe.

• Operationispossibleacrossawiderangeofclimaticconditionswithconsistentlyhighlevelsofreproducibility.

• Measuringthroughanynon-conductiveornon-magneticmaterial,RTDINCOTESTdetectsandcalculates

averagegenerallevelsofcorrosionorerosionandprovidesaninstantsitereportinameasuringmatrixformat.

RTDINCOTESTisthefast,accurateandreliablewayofsurveyingferrouspipesandvessels-throughtheir

thermalinsulation.Inoperation,itdoesnotdisturbinsulationorcoatingsandprovidesaccurateresults

throughaluminium,stainlessorgalvanizedsteelcladdings.WithRTDINCOTEST,insulationmaybehotorcold,wet,rough

orencrusted,irregularorheterogeneousorevenwithwiremesh.Throughitsexcellentrepeatability,RTDINCOTESTis

ideallysuitedforbaselineandperiodicmonitoringsurveys.

Page 2: NDT & Inspection RTD INCOTEST RTD... · NDT & Inspection RTD INCOTEST Key advantages of RTD INCOTEST RTD INCOTEST provides a reliable solution for a variety of applications. • RTD

RTD INCOTEST – fast and versatileWithacrewoftwoanddependentonaccessibility,RTDINCOTESTcansurveyandstoreupto1,000pointsperday.Itmonitorsthedecayofaneddycurrentpulsewithinasteelwall,computingtheaveragemetalthicknessbycomparingthetransienttime(echo)ofselectedsignalfeatureswithsimilarcalibrationtests.Theresultingmeasurementcanbeinfluencedbyanumberoffactorslikemetallurgyvariations(magneticandelectricalproperties)andtemperature.

Dependingonmetalthicknesstypicalsurveyscantakefrom2to40seconds.Computedaveragewallthicknessescanbeeasilylogged,andthevalidationsignaldisplayedon-screen.Rawdataisstoredforlaterretrieval.

RTD INCOTEST – technical information• Surveycapabilityofupto1,000pointsperday

dependingonaccessibility.• Reliablemeasurementscanbeobtainedinawide

rangeofclimaticconditionsandenvironmentswheretemperaturescangoupto500ºC (930ºF)andaslowas-100ºC(-150ºF).

• Constantoperationofupto8hourswithasinglebatterypack.

• Thesystemtransducermaybelocatedupto 100m(328ft)fromthebaseunit.

• Providesacomputedthicknessreadingwithin 2to40secondsdependentonwallthickness.

• Highlevelsofreproducibility+/-2%• Measuresthroughanynon-conductiveandnon-

magneticmaterialsuchasinsulationconcrete(withcladdingofaluminium,stainlesssteelorlowalloygalvanizedsteel),orfireretarder upto100mm(4”)thickandupto150mm(6”)whenpipeorvesselwallthicknessislessthan12.7mm(0.5”).

Applus RTDApplusRTDprovidesthefollowingservicesasindividualpackagesorcombinedtoprovideatotalAssetIntegrityManagementprogramme.

• Advanced(non-intrusive)InspectionServices• Sub-seaInspectionServices• EngineeringDesignSolutions• RiskBasedInspectionPlanning• InspectionManagementServices• InServiceInspection• PlantLifeManagement• MetallurgicalServices.

Importantly,ApplusRTDcanalsocalluponextensivein-houseexpertiseandresourcesforadvancedinspectionandconventionalNDT,providingatotalcapabilityformanagementofthroughlifeplantintegrity.

ApplusRTD,incollaborationwithourlocalandinternationalpartners,hasextensiveexperienceintheapplicationoftheseservicestoawiderangeofindustriesincluding:

• Oil&Gas• Petrochemical• Refining• OreProcessingandHandling• PowerGeneration.

www.ApplusRTD.com

INCOTESTonOffshoreExportRiser


Related Documents