16 Tech Circle | Natick, MA 01760 | P 866.455.5222 F 508.651.2902 | www.millennium-groupinc.com
Table of ContentsA. MILLENIUM SOFTWARE.....................................................................................................................................1
Millennium Expert.....................................................................................................................................3Millennium Enterprise...............................................................................................................................4Millennium Xtra.........................................................................................................................................5
B. MILLENNIUM HARDWARE.................................................................................................................................7Door Control Device (DCD)........................................................................................................................8Site Control Unit (SCU)..............................................................................................................................9
Elevator Control Unit (ECU).....................................................................................................................12Elevator Control Device (ECD).................................................................................................................13Relay Control Device (RCD).....................................................................................................................14Millenium Site Ethernet Interface (SEI)...................................................................................................15Trunk Interface Unit (TIU)........................................................................................................................16Control Unit Enclosures...........................................................................................................................17Power Supplies........................................................................................................................................18
C. KITS...................................................................................................................................................................19Millenium Badging Kit.............................................................................................................................20
D. SYNERGISTICS SOFTWARE................................................................................................................................23SynergisticsCitadel..................................................................................................................................24
E. SYNERGISTICS HARDWARE..............................................................................................................................25Citadel DRC (Dual Reader Controller)......................................................................................................26WaPac CC1065 / QRC Controller..............................................................................................................27
Enhanced Door Control Device (EDCD)...................................................................................................10Enhanced Site Control Unit (ESCU)..........................................................................................................11
Millennium Software
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 1
On-line Network• LAN/WANnetwork• Eachsitecanhaveasecuritymanagementworkstation• Withinabuilding,thesysteminstantaneouslyprovidescomplete,prioritized,on-lineactivityreports
• Linksamulti-buildingcomplexviadedicatedordial-uptelephonelines,wirelessorfiberoptics
• High-levelaccesscontrolsystemthatreportsalleventstoaspecifiedworkstation,issuesIDcardsandprovides comprehensivemanagement tools
• Anti-passbackprotectionEconomical• Canusethewiringandreadersofanexistingaccesscontrolsystem
• Canworksimultaneouslywithupto3differentreaderprotocols
Easy to operate• Includesacompleteinteractivehelpfunction,complementedbyanoperationmanual
• EasytouseWindows®interface• Customizableoperatorlevels• Operator-configurablereportsReliable• Eachdevicecontrollerisintelligentandautonomoussothat,intheeventofacommunicationlinkinterruption,theaccesspointwillstillremainfullyoperational
High Tech• SupportsPINandcardtechnologiesbytimezone
• Native32bitapplication• Powerfuldatabasetoolstoimport
or export data to and from otherdatabase systems
• Visualalarmmapping,thepop-upgraphicalfloorplanshowstheexactlocationofanalarm
• Uptofourgraphicalfloorplanspermonitoring point
• Fullyconfigurablesystemparameters
• Scalablefrom1doorto100,000• Monitorsfrom1to700,000points• Capableofcontrollingelevatorswithamaximumof64,000floors
• Capableofcontrollingupto80,000relaydevices(on/off)
Millenium System Overview
System Features
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 2
Millenium Expert
ApplicationMillenium expert is a feature rich access control system designed to fitawiderangeofapplicationsandsites.Itsarchitectureissuitedfororganizationsthatwishtomaintainasolidaccesscontrolnetworkusingdifferentcommunicationmodes.Inaddition,Milleniumexpertallowsoperators to manage their access control system from a standard PC workstationanywhereontheircommunicationnetwork.
System Capacities
Attributes
System Features
Model # Model #Picture PictureDescription Description
135-510951-FCD
135-510951-UPG
PK2934
Millenium Expert SoftwarePackage
Millenium Expert User Guide
Upgrade from version 1.1,1.5and2.1
Network License per PC
• Number of Sites:1,000• Access Points per System:100,000• Readers per Access Point: 1• Monitored Alarmed Points:700,000
• Elevator Control: 64,000floors,10,000elevatorcars
• Workstations Supported: 32• Relays Supported: 200,000(on/off)plus80,000optional
• Cardholders: Unlimited• Time Zones: 200• Alarms per Access Point: 7
including door contact
• Reliable network withdistributed intelligence:Doorsfunctionnormallyevenifcommunicationisoff-line
• Modular expansion; one door oronesiteatatime
• Economical upgrade from otheraccess control systems
• Adaptstofacilitiesofanysize• Interfaces to most types of
readers and cards in the industry• Interconnects with mostcommunicationnetworks(TCP/IP,twistedpair,leasedline,fiberoptic,dialupandwirelesstechnologies)
• ODBC compliant database witheasy data export and import
• Increased security betweenpanels with a proprietarycommunicationprotocol
Scheduler:• Book events• Scheduledoorlocks/unlocks,
even days or weeks in advance• Event Recurrence ManagerAlarm Monitoring:• Graphical Screens: 4 maps per
alarm point
• AlarmSound:Attach.wavfilesto alarms
• Acknowledgements,instructionsanddescriptionsFacility (Guard) Tours:• Up to 96 tours; global
or individualAccess Point Relays:• 2 per access point
• 8 modes available includingalarm response modes
MusterTrac Reporting:• Exceptions-Attendance• Overtime-Absence/PresenceAnti-passback:• Global,PairedorTimedMultiple Reader Technologies Supported
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 3
Millenium EnterpriseApplicationMillenium Enterprise is an advanced access control system designed for multiplesiteenvironments,typicallyoveraLocalAreaNetwork(LAN)oraWideAreaNetwork(WAN).ItsarchitectureisspeciallysuitedfororganizationsthatwishtomaintainoperationsinmultiplelocationsutilizingacommonSQLServerdatabase.Inaddition,MilleniumEnterpriseallowsindividualtenants,throughdatapartitioning,tomanagetheirownbuildingusingtheirownworkstations,while giving overall control of the system to the facility manager.
System Capacities
Attributes
System Features
Model #
Model #
Model #
Model #
Picture
Picture
Picture
Picture
Description
Description
Description
Description
135-509636-UCD
135-509636-FCD
135-509636-EUD
PK2932
CALL
Millenium Enterprise SoftwarePackage
Millenium Enterprise VersionUpgrade
CCTVInterface/ Call for Details
Millenium Enterprise User Guide
Database Conversion to Millenium Enterprise
Upgrade from version 2.1/ Expert to Enterprise
Third Party Data Interface
Network License per PC
• Number of Sites:1,000• Access Points per System:100,000• Readers per Access Point: 1• Monitored Alarmed Points:700,000
• Elevator Control: 64,000floors,10,000elevatorcars
• Workstations Supported: Depends on your product licensing
• Relays Supported: 200,000(on/off)plus80,000optional
• Cardholders: Unlimited• Time Zones: Global 200 (availabletoalltenantgroups),4intervalseachzone
• AlarmsperAccessPoint:7supervised inputs with 4 states
• Reliable network withdistributed intelligence:Doorsfunctionnormallyevenifcommunicationisoff-line
• Modular expansion; one door oronesiteatatime
• Economical upgrade from otheraccess control systems
• Adaptstofacilitiesofanysize• Interfaces to most types of
readers and cards in the industry• Interconnects with mostcommunicationnetworks(TCP/IP,twistedpair,leasedline,fiberoptic,dialupandwirelesstechnologies)
• Instant alarm annunciationsupportedbymaps,sounds,instructionsandreports
• Powerful database tools toexport or import data to and fromother systems
• Increased security betweenpanels with a proprietarycommunicationprotocol
Monitoring of Alarm Points:• Broadcastingofalarm
acknowledgementtoselectedworkstations
• Independentlyprogrammonitoringoptionsateachworkstation
• Writeinstructionsforselectedalarms
• LinksoundsandmapstoalarmsGuard Tours:• Buildupto96independenttoursAnti-passback:• Global,Paired,Timed&Timeout
reset (refusal of user’s card for aselectabletimeperiod)
Controllable Relay Modes:
• Noaction;1stuserautoactivate;Autoactivate
• Validuser;Rejecteduser;Anyuser;Dual custody
• Selectedalarms;Mirrorselectedalarms; Last person out
Multiple Reader Technologies Supported
135-507591-SGL
135-101806
135-101884
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 4
Millennium Xtra
Application Millennium Xtra is easy to use, fully featured access control software managed directly from an Internet Browser. With this convenience, control functions may be administered without the setup of additional, specialized workstations, saving time and money.
In the past, multiple workstations communicated with a software server with complicated connections that often presented challenges to the system administrators. Xtra simplifies this with one server and a local website accessible within the network. To add portability, any alarm event can be sent automatically via text or e-mail to any network supported device. This device can also be configured to have complete access from outside of the network. Highly secure communication protocols such as 128 bit SSL encryption ensure secure access to Millennium Xtra only for authorized personnel.
System Features • Reliable proven hardware with
modularity for flexible solutions • Data import/export capabilities• Real-time event monitoring• Multiple sessions
with different operators• E-mail/text alarm notification• Reports via scheduled e-mail• Partitioned database
• Enterprise-class software thatsupports thousands of doors
• Supports industry standard readersand cards
• Elevator Control• Multiple access levels per card• Zoned Anti-Passback• User defined data fields• Full system Lockdown
OPTIONS • exacqVision Video Interface• DMP Alarm Panel interface• Badging system• Suprema biometric readers• Salto door lock interface• Intercom interface• CBORD interface• Door toggle lock/unlock
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 5
OPERATING ENVIRONMENT: Processor: 2.8 GHz or faster, 64 Bit Compatible
Memory: Minimum of 8 GB
As the system is enlarged more memory should be added to ensure adequate performance
Hard Disk: Minimum of 120 GB Allocated for Millennium
Supported Operating Systems: Windows 7 SP1 Professional 64-bit Windows 8.1 Professional 64-bit Windows 10 Professional 64-bit Windows Server 2008 R2 SP1 Datacenter 64-bit Windows Server 2008 R2 SP1 Enterprise 64-bit Windows Server 2008 R2 SP1 Standard 64-bit Windows Server 2012 R2 Datacenter 64-bit Windows Server 2012 R2 Standard 64-bit
VMWare or MS Hyper-V Virtual hosts
Millennium Xtra includes the Microsoft SQL database engine
Browsers Supported: Internet Explorer Safari Chrome Firefox
Standard Features: Unlimited number of readers
Supports Millennium Door Control Devices and Site Control Units
Up to 100,000 cardholders
Multiple cards per user
User configurable card data
30 access levels per cardholder
Scheduled door lock/unlock
Full system lockdown capability
Alarm events via text/email
Anti-Passback capabilities
Easy Card Data import/export
Elevator Control
Optional Features: Badging System Interface
Dedicated Alarm Screen for alarm only monitoring
Video integration with exacqVision
Wireless lock integrations with Salto and VingCard
Suprema Biometric reader integration
Mercury Hardware integration, EP 1501/1502, MR52, 16IN, 16OUT
DMP Alarm Panel Integration Requires IP communications board in DMP 100/500 series controls
IP Intercom interface
Custom Database integrations are available, including CBORD
Full API
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 6
Millennium Hardware
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 7
Door Control Device (DCD)
Application• TheDCD(DoorControlDevice)isdesignedtocontrolasingle
access point. This device can accept inputs from most readertechnology,analogalarmdevices,andanaloginputsfromrequest to exit devices.
• Intheeventofacomputerorcommunicationsfailureit willstilloperateandloghistorytransactionsintothememorybuffer.
Features• SupportsWiegandCardReaderprotocols,configurablefrom0-50bits;MagstripetechnologiesABA/ISOTrack2withconfigurabledatabits;ClockandData,andMarlokopticalkeyprotocol.
• Communicatesusingvarioustypesofsupervisedwiringmethodsincluding;Daisy-Chaining,T-Tapping,HomeRunning,StarConfiguration,andHighSecurityLoopBack.
• Upto100,000DCD’scanbeconnectedover1000SCU’s(SiteControl Units).
PartNumber–149-1000958Includedinkits135-510016and135-510017(2),
064-510299(1)and064-510430(1)
SpecificationsPower Requirements• 9-14VDC,fromourstandardPowerSupply.Currentconsumptionis50mAnominal,and150mAmaximum.
Circuit Protection• Inputpowerisprotectedfromreversepolarity,overvoltage,andtransientsurges.
DCD Device Communications• Atwistedpair,multi-drop,RS-485polling scheme is used to communicatefrom the DCD to the other MilleniumDevices.
Dimensions• 4.24”x7.35”@<1lb,10.4x18.7cm@<0.4Kg
Programmable Relays• EachDCDemploys2programmableSinglepole,FormCrelaysthatareratedfor2amps@24VDC.
Alarm Monitoring• TheDCDhasthecapabilitytomonitor
up to 7 independent alarm inputs. 4aresupervisedwith1KEOLresistors,and the other 3 are normally closedcircuits. The circuit must have a breaktimeofatleast500msforthealarmtotrigger.
All Events History Buffer• 200alleventshistory,storedinRAM
memory with a minimum of 24 hoursbackup.
Operating Temperature• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity.
Event Buffer• 100softwareselectablepriorityevents(alarms,comfail,etc.).Theseeventsarestoredon-boardiftheSCUisoff-
line with the host computer. They can be programmed to send signals back tothecomputeriftheyareactivated.
Cover Tamper• On-boardintegratedtamperswitch.
Approvals and Listing• UL294
Model # Model #Picture PictureDescription Description
149-100958
060-101025
041-100992Door Control Device (DCD)
Standard Back Box
Back Box with Lock Cover
Seepage19forenclosurespecifications
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 8
Site Control Unit (SCU)
Application• TheSCU(SiteControlUnit)isacommunicationshubandmemorybufferforthedoorcontrollersandotherdeviceswithin the Millenium family. A single SCU can support up to100DCDS,4ECUsand10ECDs.On-boardsecuritymeasuresensuretheintegrityofthedataaswellaspreventingattemptedhackingorpiratingofaccounts.
Features• Allbi-directionalcommunicationstoandfromthePCcanuseeitherRS-232orRS-485protocols
• Communicationsfortheaccesscontroldevicenodeuseatwistedpair,shieldedcableonanRS-485bus
• Upto1000fullysupervisedSCUscanbeconnectedtoasinglePCrunningtheMilleniumforWindows®software• TheSCUiscompatiblewithallofthepopularcommunicationmodesfoundintoday’sinstallationenvironments:dial-up,fiberoptic,leasedline,radiofrequency,andTCP/IPNetworkingprotocol
SpecificationsPower Requirements:• 9-14VDC,suppliedbytheKabaPS1powersupply;Currentconsumptionis50mAnominal,and90mAmaximum
Circuit Protection:• Inputpowerisprotectedfromreversepolarity,over-voltageandtransientsurges
PC and SCU Communications:• RS-232viaDB-9Fconnectorora4-wireRS-485connectionusingterminalblocks.(RS-485requiresTIU)
SCU Device Communications:• Atwistedpair,multi-drop,RS-485polling scheme is used to communicatewith other Millenium devices
Dial-up Modem Support:•HayesATcommandset,at9600baud.
• Callbackfeaturewheneventbufferis80%full,orfollowingspecificevents
Supervisory Relay:• A2Amp,24VDC,singleFormCrelay that changes state when the SCU loses communicationwiththeotherboard systemAll Events History Buffer:• 2000event,storedinRAMmemory
with a minimum of 24 hours backupPriority Event Buffer:• 100softwareselectablepriorityevents(alarms,comfail,etc.)• Theseeventsarestoredon-boardiftheSCUisoff-linewiththehostcomputer. Stored events are sentto the host computer oncecommunicationsarere-established
Cover Tamper Switch:• On-boardintegratedtamperswitchExternal Clock Sync:• Terminalblockconnectionsareavailableforsynchingtherealtime clock to an external AC source • UsedforinternationalACsituationsandinfrequentcall-insApproval and Listings:• UL294Operating Temperature:• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidityDimensions:• 4.24”x7.35”@<1lb• 10.8x18.7cm@<0.45Kg
Model # Model #Picture PictureDescription Description
149-101117
060-101025
041-100992Site Control Unit (SCU)
Standard Back Box
Back Box with Lock Cover
Seepage19forenclosurespecifications
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 9
Enhanced Door Control Device (EDCD)
Specifications
Application • The EDCD (Enhanced Door Control Device) offers a larger
cardholder database and significantly faster processing andcommunications speed than the standard DCD. It controls asingle access point accepts connections to most readertechnologies.
• Stores data for up to 60,000 cards. Because the cardholderaccess levels are stored here, in the event of a computer orcommunications failure it will provide uninterrupted access control and log up to 2000 transactions into memory.
Features • Supports Wiegand Card Reader protocols, configurable
from 0-256, Magstripe formats of ABA/ISO Track 2 withconfigurable data bits; Clock and Data, and Marlok.
• Communications between EDCDs is via RS-485 using varioustypes of supervised wiring methods; Daisy-Chaining, T-Tapping, Home Running, and High Security Loop Back.
• EDCD’s communicate to the Millennium Software throughSite Control Units (SCU or ESCU). Each SCU/ESCU can supportup to 99 EDCDs, depending on system configuration needs.
Card Data Storage • Each EDCD stores data for up to 60,000
cards
Transaction History Buffer • 2,000 transaction history providesretention of card activity ifcommunications with the ESCU is lost
Alarm Event History Buffer • 100 software selectable alarmevents (alarms, com fail, etc.) arestored if communications with theESCU is lost.
EDCD Device Communications • A twisted pair, multi-drop, RS-485
polling scheme is used to communicatebetween the EDCD, the ESCU, andother Millennium Devices.
Programmable Relays • Each EDCD includes 2
programmable Single pole, Form Crelays that are rated for 10 amps @24 VDC. These are typically used fordoor locking devices
Alarm Monitoring • The EDCD has the capability to monitor
up to 7 independent alarm inputs. 4are supervised, and the other 3 arenormally closed circuits.
Circuit Protection • Input power is protected from reverse
polarity, over voltage, and transientsurges.
Operating Temperature • 14° to 104°F (-10° to 40°C) less than
90% non-condensing humidity.
Power Requirements • 9-14 VDC, from our standard PowerSupply. Current consumption is 50mAnominal, and 150 mA maximum.
Cover Tamper • On-board integrated tamper switch.
Approvals and Listing• UL 294 pending
Dimensions• 4.24” x 7.35” @ < 1lb, 10.4 x 18.7cm
@ < 0.4Kg
Model # Picture Description Model # Picture Description
149-101966
Back Box with Lock and cover
041-100992EDCD Door Control Device
060-101025 Standard Back Box
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 10
Enhanced Site Control Unit (ESCU)
Application • The Enhanced Site Control Unit (ESCU) is a communications
hub and memory buffer that sits between Millenniumdevices (DCD/EDCDs, ECUs, etc.), and the Millennium software running on a computer/server. Depending uponsystem operational needs and configuration, a singleESCU can support up to 99 DCD/EDCDs or 4 ECUs and 10ECDs.
Features • All communications between the ESCU and the
computer/server is IP which connects via anEthernet socket on the ESCU. Communicationsbetween the ESCU and the Millennium devices isRS-485, on a twisted pair, shielded cable.
• When used with EDCDs, the communications speedon the RS-485 network can be as high as 38.4k.
• Depending upon the Millennium software chosen, up to 1000 fully supervised ESCUs can be connected to a singleComputer/Server.
Specifications
Computer to ESCU Communications: • IP via the on board Ethernet
connector and Cat5/Cat6 cable.ESCU t o M i l l enni um Device Communications: • Two wire, multi-drop, RS-485 via
shielded, twisted pair
Transaction History Buffer: • 2000 event on board storage
Alarm Event History Buffer: • 100 software selectable priority event
(alarms, com fail, etc.) storage• These events are stored on-board
if the ESCU is off-line with the hostsoftware. Stored events are sent tothe host software oncecommunications are re-establishedCircuit Protection:• Input power is protected from
reverse polarity, over-voltage andtransient surges
Power Requirements: • 9-14 VDC, supplied by the PS1 power
supply; Current consumption is 50mAnominal, and 90mA maximum
Cover Tamper Switch: • On-board integrated tamper switchApproval and Listings:• UL 294 pendingOperating Temperature:• 14° to 104°F (-10° to 40°C) less than
90% non-condensing humidityDimensions: • 4.24” x 7.35” @ < 1lb• 10.8 x 18.7cm @ < 0.45Kg
Model # Picture Description Model # Picture Description
149-101992 Site Control Unit (SCU) 041-100992 Back Box with Lock Cover
060-101025 Standard Back Box
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 11
Elevator Control Unit (ECU)
Application• TheECU(ElevatorControlUnit)isthedevice
that interfaces between the SCU and the ECDs.EachECUhas16built-inrelaystocontrolelevatorfunctions.Upto4ECUscanbeconnectedtoasingleSCU,givingtheMilleniumsystemthecapabilityofcontrollingupto64,000floorrelays.
Features• Controlsasmanyas10elevatorcarsand64floorswhenfourunitsarecascadedonasingle SCU.
• 10,000usercapacity.WhenfourunitsareconnectedtogetheronasingleSCU,40,000users are available.
Specifications
Input Power Requirements:• 120VACinputona2Ampunswitcheddedicatedcircuit(EC2-101190)
• Forinternationalpowerrequirementsthereisa240VACmodelavailable(EC2-101191)
Programmable Relays:• EachECUemploys16programmablesinglepole,FormCrelaysthatareratedfor5Ampsat24VDC
All Events History Buffer:• 2000events,storedinRAMmemory
with a minimum of 24 hours backupAlarm Monitoring:• Monitorsupto4independent
Normally Closed (nonsupervised) alarm inputs. The circuit must have abreaktimeofatleast500msforthe alarm to triggerPriority Event Buffer:• 100softwareselectablepriorityevents(alarms,comfail,etc)
• Theseeventsarestoredon-boardiftheECUisoff-linewiththehostcomputer. Stored events aresent to the host computer once
communicationsarere-establishedCover Tamper Switch:• On-boardintegratedtamperswitch
Fuse Protection:• A2Ampslowblowfuseprotectsthe
AC inputKeyswitch Override:• UsedbyFireDepartmentpersonnel
to override the access control systemduring an emergency
Operating Temperature:• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity
Dimensions:• 14.25”X12.25”X4.25”@20lbs• [email protected] / Listing:• UL294
Model # Picture Description
EC2-101190
EC2-101191
120VElevatorControlUnit
240VElevatorControlUnit
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 12
Elevator Control Device (ECD)
Application• The ECD (Elevator Control Device) allows a key/card reader
to communicate with the Elevator Control Unit (ECU) in orderto control elevator access.
Features• SupportsWiegandcardreaderprotocols,configurablefrom0-50bits;magneticstripetechnologiesABA/ISOTrack2withconfigurabledatabits;Marlok™opticalkeyprotocol
• TheECDcommunicatesusingasupervised,home-runwiringconfigurationtotheECU
• Upto10ECDscanbeconnectedtoasingleSCUunit,withmaximumarchitectureof10,000ECDspersystem
Specifications
Power Requirements:• 9-14VDC,suppliedbya9VDCclassIIplug-intransformer;Currentconsumptionis50mAnominal,and100m maximum
Circuit Protection:• Inputpowerisprotectedfromreversepolarity,over-voltageandtransientsurges
ECD Device Communications:• Atwistedpair,homerun,RS-485
polling scheme is used tocommunicate from the ECD to the ECU
Cover Tamper Switch:• On-boardintegratedtamperswitchOperating Temperature:• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity
Dimensions:• 4.25”X7.35”@<1lb• 10.8x18.7cm@<0.45KgCertification / Listing:• UL294
Model # Picture Description
149-101179
060-101025
Elevator Control Device (ECD)
Standard Back Box
Model # Picture Description
041-100992 Back Box with Lock Cover
Seepage18forenclosurespecifications
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 13
Relay Control Device (RCD)
Application• The RCD (Relay Control Device) expands the controlcapabilitiesofMillenium.TheRCDisanadd-onboardthatcancontrolupto8additionalprogrammablerelays,foranyproduct that requires voltage switching. It operates and logshistorytransactionsintothememorybufferevenifcommunicationswiththeSCUhavebeeninterrupted.
Features• EachRCDhas8individuallyisolatedsinglepole,FormCrelayoutputs,whichcanbeprogrammedforactivationbyavariety of triggering sources
Specifications
Power Requirements:• 9-14VDC,suppliedbytheKabaPS1powersupply;Currentconsumptionis50mAnominal,and200mAmaximum
Circuit Protection:• Inputpowerisprotectedfromreversepolarity,over-voltageandtransient surgesRCD Device Communications:• ATwistedPair,RS-485pollingscheme
is used to communicate with the otherMillenium Devices
Programmable Relays:• EachRCDemploys8programmable
singlepole,FormCrelaysthatareratedfor2Ampsat24VDCAll Events History Buffer:• 2000event,storedinRAMmemory with a minimum of 24 hours backupPriority Event Buffer:• 100softwareselectablepriorityevents(alarms,comfail,etc.)
• Theseeventsarestoredon-boardiftheRCDisoff-linewiththehostcomputer. Stored events aresent to the host computer oncecommunicationsarere-established
Cover Tamper Switch:• On-boardintegratedtamperswitchOperating Temperature:• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity
Dimensions:• 4.24”x7.35”@<1lb• 10.8x18.7cm@<0.45kgCertification / Listing:• UL294
Model # Model #Picture PictureDescription Description
149-100993
060-101025
041-100992Relay Control Device (RCD)
Standard Back Box
Back Box with Lock Cover
• TheRCDcommunicatesusingvarioustypesofsupervisedwiringmethods,includingDaisyChaining,T-Tapping,HomeRunning,StarConfiguration,andHighSecurityLoopBack
• Upto10RCDscanbeconnectedtoasingleSCU,withamaximumarchitectureof80,000relayspersystem
Seepage18forenclosurespecifications
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 14
Millenium Site Ethernet Interface (SEI)
Application• TheSEI(SiteEthernetInterface)isdesignedtoprovidecommunicationsbetweentheMilleniumPC and the Site Control Unit(s) by means ofEthernetNetworksutilizingaTCP/IPprotocol.
SpecificationsPower Requirements• 12-15VDC,suppliedbyeitheracentralpowersupplyoranauxiliarypowersupply,700mAmaximum.
Model # Picture Description
051-507972
051-509428
Site Ethernet Interface(SEI)120V
Site Ethernet Interface(SEI)220V
IP Address Setting• SoftwarethroughRS-232port,or
through TelNet
Data Backup• Nonvolatilememory
Network Interface• 10baseT• StaticIP
SCU Interface• RS-232-CCommunications Protocol (Network)• TCP/IP
Communications Protocol (SCU interface)• Proprietary
Operating Environment• 32°to104°F(0°to40°C)lessthan90%non-condensinghumidity
Dimensions• 7”X6”X11/4”@21lbs• [email protected]
Minimum Requirements• MilleniumWindows®version1.5
and up
Installationdiagramshowing the Millenium Server/Workstationconfigurationandmixedcommunicationmodes.
Ethernet
Millenium® Server PCSEI
Millenium® Workstation
Millenium®Workstation
Modem
SCU#2
SCU#1
SEI
SCU#3
SCU#4
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 15
Model # Picture Description
135-101186-001
135-101186-002
135-100957-001
135-100957-002
051-507968
051-507967
003-101394
003-101395
120VTIUHardwarepackage,withoutMarlokkeyreader.Includes:TIU(120V),walltransfomer&manuals.Formagneticstripe
card,biometricsandtouchkeyaccess.
240VTIUHardwarepackage,withoutMarlokkeyreader.Includes:TIU(240V),walltransfomer&manuals.Formagneticstripe
card,biometricsandtouchkeyaccess.
120VTIUHardwarepackage,withMarlokWedgekeyreader.Includes:TIU(120V),walltransfomer&manuals.
For Marlok key access.
240VTIUHardwarepackage,withMarlokWedgekeyreader.Includes:TIU(240V),walltransfomer&manuals.
For Marlok key access.
TIUPack120VReplacement TIU and wall transformer
TIUPack240VReplacement TIU and wall transformer
120Vto9VDCwalltransformer500mAforTIU
240Vto9VDCwalltransformer500mAforTIU
Trunk Interface Unit (TIU)
ApplicationTheTIU(TrunkInterfaceUnit)isanRS-232toRS-485dataprotocolconverter.Itisusedwhenthe Site Control Unit (SCU) is located more than 50ftfromthecomputerorwhenmultipleSCUsaredaisy-chainedinthesamebuilding.
System Features• ConvertsRS-232protocoltoRS-485protocolforlongercommunicationcablingdistances
• FrontpaneldiagnosticlightsforinstantverificationofcommunicationstatusbetweenthecomputerandtheSCU
SpecificationsPower Requirements• 9-14VDC,suppliedby9VDC
class ll plug in transformer; Currentconsumptionis50mAnominal,100mAmaximum
Connection to the PC• 15”cablewithaDB-9Fconnector
Connection to the SCU• RS-485,5conductor,shieldedcableCommunications Distance• Upto5000ftfromthecomputerto
the last SCU on the trunk
Operating Temperature• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity
Dimensions• 3.60”x5.20”x1.30”at2lbs.• 9.1x13.2x3.3cmat0.90Kg
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 16
Control Unit Enclosures
Control Panel Enclosure• TheControlPanelisbuiltofheavy14-gaugesteel,andincludesabackplatereadytoreceivecombinationsof3Milleniumcircuitboards.Theeasytoremovebackplateallowsforquickassembly,wiringandtestingatthedealer’sfacilitiespriortoinstallation.Thecontrolpanelcanthenbewallmountedwithoutremovingtheback plate.
• Thebackplateconsistsofgalvanizedsteelincluding12stainlesssteelstand-offspositionedtoseatuptothreeMilleniumcontrolboards.AnycombinationofthreeDCDs,SCUs,orRCDscanbequicklysnappedon.
• Thebeigepaintedcontrolboxincludesacamlock,2keys,afulllengthpianohinge,ventilationholesand6knock-outs.
• 14.2”x12.2”X4.1”-36.2x31.1x10.5cm
Back Box Package• ScrewMountedCover• MountstheDCU• 111⁄2”X51⁄4”X13⁄4”(292mmX133mmX44mm)• IncludesmetalStand-off
Surface Box• CamlockMountedCover• MountstheFCUorDCU• 103⁄4”X103⁄4”X23⁄4”(273mmX273mmX70mm)• IncludesmetalStand-off
#062-510235
041-100992
#060-101025
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 17
Model # Picture Description
PS1-100212-001
PS1-100213-001
WPT-1
PS2-510068
124-033067
EPS-1
132-024003
132-100780
PowerSupplyand8AHBatteries,120V/60Hz5A/12V,lineconditionerandbatteriesincluded.
ULListed(294),CSAListed(1950)
PowerSupplyand8AHBatteries,240V/50Hz5A/12V,lineconditionerandbatteriesincluded.
CSA Listed (1950)
Wire-InTransformer120Volts-1A/12VOptiontoEPS-1.Mayberequiredbysomecities
PowerSupplyandCharger120V/60Hz12V,2.5AmpKeyLockableCabinet
(Withoutlineconditioner)Includeswalltransformer
LineConditionerPCBforPS1
PowerSupplyand4AHBattery,120V/60Hz1A/12V.(Withoutlineconditioner)
Battery,6V8AHgelledleadacidforPS1(2 required per power supply)
Battery,12V4AHforEPS-1(One required per power supply).
Power SuppliesApplication• ThePS1powersupplyisarobustfilteredDCpowersourceforthe
Millenium controller boards. Its secondary board generates the necessarybiasingvoltagesfortheRS-485communications,whichlinkthecontrollerboards to the Site Control Unit.
• Includesbatteries,enclosure,andkeylock
SpecificationsInput Power Requirements• Requires120VACor220VACinputon
a 5 Amp unswitched dedicated circuitOutput Power• Deliversaregulatedandfiltered13.8VDCoutputat5Amps
Battery Backup• Usestwo6Volt,8Ampleadacidtypebatteries
Fuse Protection• TheACinputisprotected
by a 2 Amp low blow fuse
• A5Ampslowblowfuseisusedtoprotectthebatteries
Protection• TheDCoutputiscurrentlimited
against possible short circuits• ACfailuremonitoring• FormAoutputformonitoringthe
status of the AC input
Cover Tamper Switch• FormAoutputtomonitorthestatus
of the enclosure door
Approvals and Listings• UL294,CSA1950
Operating Temperature• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity
Dimensions (PS1-100212-001) (PS1-1002213-001)• 14.25”x12.25”X4.125”@27lbs• [email protected]
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 18
Millennium Kits
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 19
Millenium Badging Kit
Attributes
System Features
Automatic Portrait Background:• Changecolorortexturebehindthe
portrait without retaking itAdobe and TrueType Font Support:•UseanyWindows®font,including Adobe Type 1• AdobefontsrequireAdobeType
ManagerJPEG Compression:• Portraitstoragesizeis
approximately 10KB per image• ImportsandexportsTIFF,PCX,BMPandotherimagefileformats
Ghost Image / Electronic Overlay:• Turnanygraphicimageintoan
electronic overlay to cover part ofthe portrait and data
• Printaduplicate,semi-transparentcopy of the portrait on the badgefor added security
Connectivity to Standard Databases• ODBCcompliantimport/exportutilityReporting:• SortandselectonanydatabasefieldNetwork Support• Multiworkstationsupport;securityguardsatanystationcanmatch the user photo from thedatabase with the person thatrequested access
• Supportssignaturepadsandmagneticstripeencoding
Password Protection• Assignseachoperatorasecurityleveltoprotectconfidentialend-userinformation
Badge Creation History• Automaticallymaintainshistoryofbadgeissuedate,alongwithreasons for issue and operator
Remote Camera Control• Zoom,orAuto-centerportrait
with keyboard or mouse• Color,brightness,contrast
and white balance remotelyadjusted
• Supportsprintingtoproximity,Wiegand card formats and encodingofmagneticstripes
• Millenium2.1/ExpertorEnterprisesoftwareapplication
• Windows98SEandabove• Easytousegraphicaluserinterface• User-friendlycardlayout• Draganddropplacementofgraphic
elements
• Multiworkstationsupport;securityguardsatanystationcanmatchtheuser photo from the database withthe person that requested access
• SupportssignaturepadsandmagneticstripeencodingPasswordProtection
• Assignseachoperatorasecurityleveltoprotectconfidentialend-
userinformation
• Includesstaticandvariabletext• Automaticallymaintainshistoryofbadgeissuedate,alongwithreasonsfor issue and operator
• Zoom,orAuto-centerportraitwith keyboard or mouse
• Color,brightness,contrastandwhitebalanceremotelyadjusted
ApplicationThe Millenium Badge Module allows you to create and supply your own photo ID badges. It consists of several optionstofityourneeds:asoftware-controlleddigitalcamera,ahigh-endimagingcapturecard,andpowerfulWindows®-basedsoftware.Badgescanincludeabarcode,digitalsignatureormagneticstripeencodingcompatiblewithouron-lineandstandaloneelectronic access control systems.
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 20
Millenium Badging Kit (continued)Attributes
Multiple Video Inputs• Supportedvideoinputsandformats
include composite NTSC andPAL,S-VHS&RGBforworldwideapplications
• Built-inTWAINinterface(forportable digital cameras andscanners)
Printer• Multipleprintersupport• UseanyWindows-compatibleID
card printerPrinting• Unattendedbatchprintingorbadgesbyname,IDnumber,typeor report
• PrintreportswhichincludephotoIDonanyWindowscompatibleprinter
• Doublesizedbadgeprinting(withcompatibleprinter)
• PrintWindowsbarcodefonts• Producecopy-proofoverlaysfor
placement over bar codes
Reporting• Sortandselectonanydatabasefield
Minimum PC requirement• Pentium®PCwith2serialports• SVGA15inchmonitor• Mouse&keyboard• 800X600VGAscreenresolutionComponents• MilleniumBadgeModuleapplication
• SecuritykeyOptional components• Signaturepad• FlashPointhighresolutionSVGA
capture card• CCDhighresolutioncamera,withremotecontrolandzoom
• Portraitlightingkitwithdesktopbase
• Systemcables• Factory-presetPC
• Modularpackagesavailableforyourspecificneeds
Supplies• MosttypesofPVCcards
Model # Picture Description
135-509233
1600-30-1260
1600-30-1280
1600-30-1270
1600-30-1280 Badging Camera with Light Kit and Stand
Hardware Kit #1Includes:Pentiumprocessor,15”colormonitor,keyboardandmouse.PCspecificationsubjecttochange.Askyoudealerforinformation.ImageCapturecard-PCI,portraitlightkit,light
andcamerastand,anddigitalcamera.
Hardware Kit #3Includes:Lightandcamerastand,ImageCapturecard-PCI,computer. This kit can be used worldwide regardless of the
TVstandardandvoltage.
Hardware Kit #2Includes:ImageCapturecard-PCIwithcable(toVHScamera).UsedincombinationwithMilleniumbadgesoftwareandportabledigitalcameraorvideocamera.Thiskit
canbeusedworldwidewherethePAL,NTSCorSCCAMvideostandardsapply.
MilleniumBadgesoftwareonlyadd-onmoduleOnCD-ROM.RequiresMilleniumversion2.1/Expert,Millenium
Enterprise. Includes: Quick Start Guide and security key.
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 21
Millenium Badging Kit (continued)
Model # Picture Description
M9005-724
M9005-725
M9005-726
M9005-727
M9005-751
N9005-761Med
M9005-772
M9005-946
M9006-381
PF3
PCF6
PCX
PC1
CK1
120-509157
PCX-PF2
Magicard Rio single side color card printer
Magicard RioM single side with mag encoding
Magicard RioMS single side with mag + chip encoding
Magicard RioS single side with chip only
MagicardRioLC1/D5panelcolordyefilmYMCKO-350images
Magicard Rio Cleaning Kit (medium 10 cards/ 2 pens/ 3 cleaning rollers)
MagicRio/Tango5tackyrollers-cleaningsystem
MagicardRioCleanCards(bulk-10perpackage)
AltoMsinglesideentrylevelhandfeedprinterwithMagneticencoder
Alto500shotblackresincassettedyefilm
Alto100PVCcardsindispensersplus100shotPF2cassetteYMCKO
Alto empty card dispenser
Alto50PVCblankcardsindispenser
Altocleaningkit(5-Tcards,1pen)
SignaturePad,PressureSensitiveTouchPad1024x1024,418x789DPI
Alto2qty.reader-to-fill50-cardcapacitydispensersforloadingtechnologycardsplus100shotPF2cassetteYMCKO
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 22
Synergistics Software
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 23
Synergistics CitadelApplicationCitadelisamodern,affordablemulti-siteaccesscontrolsystemdesignedtocontrol a single building or a virtually unlimited number of buildings using either directconnectionoverwireorfiber,orremoteconnectionoverdialuptelephonelines. Data entry is supported at the host computer which may be shared with other programs while Citadel is running in background. Access control and alarm monitoring are performed at each controller from distributed databases where all trancactionsareloggedtemporarilyforscheduledhostuploadingandinputpointalarmsarereportedinrealtimetothehostcomputer.
Attributes
System Features
Model # Picture Description
CitadelSW31-0001
31-0002
Citadel System SoftwarePackage
Citadel Firmware used for upgrades from Building Watch
Alarm Monitoring AndI/O Specifications:• Supports5inputpointspercontroller,(expandableto13)
• Supports5relayoutputpointspercontroller,(expandableto13)
• Supportsinputtooutputpointmapping
• Timedinputpointmasking• Timescheduleuploadingofsitetransactionlog
• Realtimeandautomaticuploadingof alarms to host computer
• InputpointstatusannunciationinactivealarmWindow
• Timedelayeddoorajarmonitoring(door open too long)
• Monitorsforceddooranddoorajarwithasingleinputpoint
System Logging:• ScheduledTransactionLogging• RealTimeAlarmLoggingCommunications:• RS232Serialportcommunications
between host computer and sites.
• Supportsdirectwirecommunicationwith local site.
• Supportsdirectmodemcommunicationswithlocalsite
• Supportstelephonedialupcommunicationswithremotesites
• Hostcomputertositecommunicationsbyanyoralloftheabovemethodsofcommunications
• RS4852wiremulti-dropcommunicationsbetweensitecontrollers
• True distributed processing system• 4,000 Cardholders per controller• Single or block entry of cards• Easy database backup and restore
from within the softwareprogram
• Card issue levels for mag stripecards
• System database stored inMicrosoft Access
• Supports report generation
• User defined card format• 32 card readers or keypads
per site• Supports all common card
technologies• Supports biometrics and keypads• Supports multiple reader
technologies per system• Supports 208 input points per site• Supports 32 programmable
privilege groups per site• Supports 64 programmable time
schedules per site• 32 Programmable holidays• Supports virtually unlimited dial- up sites)• Supports 2 direct wired sites from
serial port configuration.• Timed Door Control• Antipassback• Supports optional video image
personnel identification badgedesign, printing and management
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 24
Synergistics Hardware
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 25
Model # Picture DescriptionDRC2032C31-0005
DRC2032CB31-0012IO200031-1004
CitadelDualReadercontroller(includesenclosure&powersupply)
Citadel I/O expansion board with (8) inputs and (8) outputs
CitadelDualReadercontrollerandpowersupplywithbatterybackup. Card readers not included. All listed card readers may be used with this product.
Citadel DRC (Dual Reader Controller) ApplicationThe Citadel DRC (Dual Reader Controller) is designed to control 2 access points. The DRC’s 2 card reader input ports can accept input from most reader technologies,analogalarmdevices,andanalogrequesttoexitdevices.TheDRCisequipped to control 4 output relays (2 door relays + 2 auxiliary relays). In the event ofacomputerorcommunicationfailure,itwillcontinuetooperateandloghistorytransactionsintothememorybuffer.Expandingbeyond2doorsissimpleandinexpensive with the Citadel system; up to 16 DRC panels can be linked together usingasecondaryRS-485network.
Specifications
System Features
Power Requirements:• 12VAC40VA
PC to DRC Communications:• IPnetwork(Ethernet)• SerialRS-232• Dialupmodem
DRC to DRC Communications• RS-485Network
Circuit protection• CardReaderandotherinputports
are protected from over voltage andtransient surges
Programmable Relays• EachDRCemploys2programmablesingle-pole,dualthrowrelaysthatareratedfor10Ampsat250VAC
All Events History Buffer• 2000transactioneventstoredinbattery-backedRAMmemory
Alarm monitoring• TheCitadelDRCcanmonitor
independent alarm inputs includingdoorforcedandotheruserdefinableinputpointsinrealtime.Whendialupcomm.isused,DRCwillinitiateacall to the host in the event of an
alarm.
Event Buffer• Eventsstoredon-boardwithhost
selectable upload frequency. Alarmssent to host immediately.
Approvals and Listing• UL294Equivalent?
Operating Temperature• 14ºFto104ºF(-10ºto40ºC);<90%non-condensinghumidity.
Dimensions and Weight• 8.5”x7.5”@<1lb
• SupportsWiegandprotocols,configurablefrom0-50bits,andmagneticstripetechnologiesABA/ISOTrack2withconfigurabledatabits.
• EachDRCcanbeconfiguredtocommunicate directly to the host PCviaadirectseriallink(RS-232),dial-upmodem,orthroughanIPnetwork.
• 2Readers• 2DoorRelays• 2AuxiliaryRelays• 5Inputpoints(expandsby8withoptionalIOE)
• Upto16DRC’scanbelinkedtogetherthroughasecondarytwisted-pairRS-485networkeliminatingtheneed for a Site Control Unit. In suchaconfigurationoneoftheDRC’satthe site is connected to the host PCandactsasthemasterDRC,whileupto15additionalslaveDRC’sarelinkedto the PC through that DRC via thesecondaryRS-485network.
• 4,000–8,800cardspercontroller• Standardanduser-definedcard
formats
• 1Alarmoutputpoint(expandsby8withoptional(IOE)
• TimedDoor/AuxRelayControl• InputandOutputpointmapping• 4-digitPIN• 32privilegegroupspersite• 64timeschedules+32holiday
schedules per site• Usesbiometricsandkeypads• Transactionlogging• Realtimealarmmonitoring• Anti-passback• Automatictransactionuploading
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 26
WaPac CC1065 / QRC ControllerSystem Features
• WapacorXtrasoftwarecompatible• Supportfor20,000Cards,Expandableto80,000• 1,000EventBuffer• Stand-AloneDistributedProcessing• 64TimeSchedules• 64AccessCodes• 64ProgrammableHolidaySchedules• 4CardReadersPoints• 4DoorInputPoints• 4RequesttoExitInputPoints• 45A30VDCDoorRelays• 45A30VDCAuxiliaryRelays• 4AuxiliaryInputs• 1DedicatedAlarmOutput• CoverTamperInput• CommunicationsStatusIndicator
Model # Picture Description
CC1065TAW06-5005
CC1065NW06-5009
CC1065DAW06-5013
PIO1060AREW06-6002
PIO1060AW06-6004
QRC1065W41-0015
QRC1065WPB06-4055
CC1065NWPB06-4068
CC1065NWMPB06-4069
CC1065DAWMPB06-4067
21-0062
MOD56
WaPacDial-upCommunicationControllerAssemblyProvidesdialupmodemcommunicationswithhostcomputer.Assemblyincludesenclosure/powersupply,communicationscardfordialupandQRCBoard.Includessupportfor(4)readersand(9)I/Os.Requires(2)modems,pleaseseePart#09-0010
WaPacNetworkCommunicationControllerAssemblyProvidesnetworkcommunicationswithhostcomputer.Assemblyincludesenclosure/powersupply,LantronicscommunicationscardfornetworkcommunicationsandQRC
board. Includes support for (4) readers and (9) I/O’s
WaPacDirect-WiredCommunicationControllerAssemblyProvidesdirectwiredcommunicationswithhostcomputer.Assemblyincludes
enclosure/powersupply,CommunicationscardfordialupcommunicationsandQRCboard. Includes support for (4) readers and (9) I/Os.
Programmable (16) input point and (16) relay output controller for WaPac May be used for elevators and alarm points
Programmable (16) input point controller for WaPac. No relays on panel
WaPac Quad reader controller. Includes support (4) readers and (9) I/OsAssembly includes enclosure/power supply
WaPac Quad reader controller. Includes support for (4) readers and (9) I/Os
WaPacnetworkcommunicationscontrollerforTCP/IP,includingLantronicscommunicationcard
WaPacnetworkcommunicationscontrollerforTCP/IP,includingLantronicscommunicationcardandexpandedmemory
WaPacdirect-wiredcommunicationscontrollerwithexpandedmemory
WA-PACDOStoWA-PACPROfirmwareUPGRADE/formulti-cardformat,orolderfirmware
External 56K baud modem
Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 27
16 Tech Circle | Natick, MA 01760 | P 866.455.5222 F 508.651.2902 | www.millennium-groupinc.com