1
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
PREPARATION
Approximate Installation Time: 60 minutes
Tools Required for Installation:
➢ Chop Saw or Hacksaw ➢ Electric Drill ➢ 3/16” Masonry Drill Bit ➢ 9/64” Metal Drill Bit ➢ Philips Bit ➢ Pencil / Felt Tip Pen ➢ Safety Glasses
➢ Measuring Tape ➢ Masking Tape ➢ Standard Screw Driver ➢ Phillips Screw Driver ➢ Level ➢ Rubber Mallet ➢ Clear Caulking or Sealant
QUESTIONS
Before beginning installation of product, make sure all parts are present. Compare parts with package contents list
and diagram below. Grid appearance may differ from images shown. If any part is missing or damaged, do not
attempt to install the product.
Please call our customer service department at 1-800-874-8601, 8 am - 5 pm EST, Monday to Friday.
Rev. 07/01/2018
2
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
CST 998 Sill / Header 2
CST 991 Sill Cover Dam 1
CST 933 Header Cover 1
CST 993 Door Panel Wall Jamb 1
CST 956 Inline Panel Wall Jamb 1
CST 926 Strike Post with Magnet 1
CST 906 Inline / Door Jamb Cover 2
CST 927 & C 176 C Drip Rail with Drip Sweep 1
C-5313-8O or
SQ8X8O
8” Ladder Pull Back-to-Back Handle 8” Square Pull Back-to-Back Handle
1
1329 Plastic Screw Anchor 11
6-8114PHP Installation Screw (#8 x 1-1/4”) 11
878PHPO Panel Adjustment Screw (#8 x 7/8”) 15
638PHPTO Drip Rail Screw (#6 x 3/8”) 2
CP933 Drip Rail Plug (Left / Right Set) 1
- Door Panel and Inline Panel Assemblies 2
PACKAGE CONTENTS
3
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
CST 933
878PHPO (3x)
CST 998
878PHPO (3x)
CST 998
878PHPO (3x)
DOOR
PANEL
638PHPTO (2x)
CP933 CST 991
CST 906
HANDLE
CST 993
CST 926
CST 906
CST 927
C 176 C
878PHPO (3x)
6-8114PHP (6x)
1329 (6x)
878PHPO (3x)
1329 (5x)
6-8114PHP (5x)
CST 956
INLINE
PANEL
4
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
STEP 1. TRIM AND POSITION SILL ON CURB CENTERLINE
➢ Strike a centerline on the curb where the unit will sit.
➢ Measure the opening at the curb along the centerline.
Trim the Sill CST 998 (with weep holes) to fit.
➢ Position and center the Sill on the centerline with the
weep holes to the inside of the shower enclosure.
Temporarily tape in place to prevent movement.
Outside Shower
Enclosure
MARK CENTERLINE
WEEP HOLES
TO INSIDE
CST 998
CST 998
MEASURE CURB OPENING
INLINE PANEL ON LEFT SIDE
DOOR ON LEFT SIDE
INLINE PANEL ON RIGHT SIDE
DOOR ON RIGHT SIDE
CST 993 CST 956
CST 993 CST 956
STEP 2. IDENTIFY DOOR AND INLINE PANEL LOCATION
5
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
➢ Set the Inline Panel Wall Jamb CST 956 into the Sill CST 998 and up
against the wall on the Inline Panel side.
➢ While holding the Jamb plumb with a level, use the pre-drilled holes in
the Jamb to pencil mark (5) hole locations on the wall.
➢ Remove the Jamb and drill installation holes 1-1/2” deep using a 3/16”
masonry bit. Insert Plastic Screw Anchors 1329 into the holes.
➢ Secure the Jamb in place using (5) Installation Screws 6-8114PHP
(#6 Head - #8 x 1-1/14” Pan Head Philips).
STEP 3. INSTALL INLINE PANEL WALL JAMB
CST 956
CST 998
PL
UM
B
CST 956
CST 998 P
LU
MB
Outside Shower
Enclosure
➢ Set the Door Panel Wall Jamb CST 993 into the Sill CST 998 and up against the
wall on the Door side.
➢ While holding the Jamb plumb with a level, use the pre-drilled holes in the Jamb to
pencil mark (6) hole locations on the wall.
➢ Remove the Jamb and drill installation holes 1-1/2” deep using a 3/16” masonry bit.
Insert Plastic Screw Anchors 1329 into the holes.
➢ Secure the Jamb in place using (6) Installation Screws 6-8114PHP (#8 x 1-1/14”).
6-8114PHP (5x) 1329 (5x) CST 956
1329 (6x) 6-8114PHP (6x)
CST 993 CST 998
STEP 4. INSTALL DOOR PANEL WALL JAMB
CST 993
Outside Shower
Enclosure
CST 998
PL
UM
B
CST 993
PL
UM
B
6
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
STEP 5. SET INLINE PANEL
➢ Set the Inline Panel into the Sill CST 998 and push it
onto the Inline Panel Wall Jamb CST 956 until the
Panel is tight against the Jamb. The metal grid is to
the outside.
INLINE PANEL
CST 998
CST 956
CST 956
INLINE
PANEL
Outside Shower Enclosure
➢ Insert (1) Inline / Door Jamb Cover CST 906 into the
open edge of the Inline Panel and (1) Cover into the
Door Panel Wall Jamb CST 993.
➢ The Covers insert into the channels toward the inside
of the shower enclosure.
CST 993 INLINE PANEL
Outside Shower Enclosure
CST 993
CST 906
CST 906
STEP 6. INSERT INLINE PANEL COVER AND DOOR JAMB COVER
INLINE
PANEL
7
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
➢ Measure between the Door Panel Wall Jamb CST 993 and the Inline Panel at the Header CST 998.
Trim the Header Cover CST 933 to the measurement obtained.
➢ Snap the Header Cover into the Header with the flange toward the inside of the enclosure.
➢ Measure between the Jamb and Inline Panel at the Sill CST 998. Trim the Sill Cover Dam CST 991
to the measurement obtained.
➢ Snap the Sill Cover into the Sill with the lip toward the outside of the enclosure.
STEP 8. TRIM AND INSTALL HEADER COVER AND SILL COVER
STEP 7. TRIM AND INSTALL HEADER
➢ Measure the shower opening above the top of the Door
Panel Wall Jamb CST 993 and the Inline Panel. Trim
the Header CST 998 (no weep holes) to fit.
➢ Set the Header over the Jamb and Inline Panel.
Outside
Shower
Enclosure
INLINE
PANEL
CST 998
MEASURE
CST 991
CST 933
CST 993
MEASURE
OPENING
CST 993
CST 998
CST 993
CST 998
MEASURE
CST 998
CST 998
CST 933
CST 998
CST 991
INLINE
PANEL
8
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
STEP 9. INSTALL STRIKE POST
➢ Insert the Strike Post CST 926 opposite the Door Hinge
location, into the outside channel of the Inline Panel or the
Door Panel Wall Jamb CST 993.
➢ Insert the Strike Post with the Magnet facing to the outside
of the enclosure and the polarity line away from the Door
opening.
➢ The Strike Post sits on top of the Sill Cover Dam CST
991, and the Header Cover CST 933 rests on top of the
Strike Post.
STEP 10. INSTALL DOOR PANEL
Outside Shower Enclosure
INLINE PANEL
➢ As per the Door Hinge location, insert the Door Hinge
Post into the outside channel of the Door Panel Wall Jamb
CST 993 or the Inline Panel.
➢ Insert the Door Panel as swinging open to the outside of
the enclosure and with the metal grid to the outside.
➢ The Hinge Post sits on top of the Sill Cover CST 991.
Outside Shower Enclosure
HINGE POST
SWING
OPEN OUT
CST 993
MAGNET
POLARITY LINE
CST 991
CST 926
INLINE
PANEL
DOOR PANEL
DOOR PANEL
CST 926
CST 993
CST 991
HINGE POST
INLINE PANEL
CST 933
9
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
3/8”
CST 926
1/4”
878PHPO (3x)
STEP 11. CHECK DOOR OPERATION AND SECURE DOOR AND INLINE PANELS
➢ Open and close the Door Panel to make sure it is operating properly. Check for the correct clearance between the Door
Panel Strike and the Strike Post CST 926 for proper magnetic closure alignment.
➢ Adjust the unit along the curb by telescoping the Strike Post and the Door Hinge Post in or out of the Inline Panel and
the Door Panel Wall Jamb CST 993 as necessary. The Hinge Post and Strike Post each allow maximum 3/8”
adjustment out.
➢ The Inline Panel has maximum 3/8” adjustment out on the Inline Panel Wall Jamb CST 956. Trim the Header Cover
CST 933 and Sill Cover Dam CST 991 as needed to adjust the Inline Panel.
➢ When satisfied with unit operation, secure the Door
Panel and Inline Panel from inside the enclosure
with Panel Adjustment Screws 878PHPO (#8 x
7/8” Pan Head Philips (Black Head)). Drill 9/64” pilot
holes 7/8” deep at each Screw location.
➢ Secure the Inline Panel to the Inline Panel Wall
Jamb CST 956 with (3) Screws at top, middle and
bottom. Locate Screws at 1/4” from the edge of the
Panel. Place Screws at 5” from the top and bottom
of the Panel.
➢ Secure the Door Hinge Post to the Door Panel
Wall Jamb CST 993 with (3) Screws at top, middle
and bottom. Locate Screws at 1/4” from the edge of
the Jamb. Place Screws at 5” from the top and
bottom of the Jamb.
➢ Secure the Strike Post CST 926 to the Inline Panel
with (3) Screws at top, middle and bottom. Locate
Screws at 1/4” from the edge of the Panel. Place
Screws at 5” from the top and bottom of the Panel.
MAGNETIC CLOSURE
ALIGNMENT
CENTER
Inside Shower Enclosure
Inside Shower Enclosure
3/8” 3/8”
1/4” 1/4”
CST 956 HINGE POST
DOOR PANEL INLINE PANEL 878PHPO (3x) 878PHPO (3x)
CST 993
CST 993
5”
5”
CST 956
INLINE
PANEL
DOOR
PANEL
878PHPO (3x)
878PHPO (3x)
878PHPO (3x)
CST 926
9/64” PILOT HOLES
HINGE
POST
10
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
Inside
Shower
Enclosure
STEP 12. SECURE HEADER AND SILL
➢ Secure Header and Sill CST 998 from inside the
enclosure with (3) Panel Adjustment Screws
878PHPO (#8 X 7/8”). Drill 9/64” pilot holes 7/8” deep
at each Screw location.
➢ Secure the Header and Sill to the Wall Jambs CST
956 and CST 993 at each end, and to the Inline Panel
vertical stile at center. Locate Screws at 1/4” from the
edge of the Header and Sill. Place Screws 1/4”
horizontally from the Panel and Door Jamb edges to
align with Screws securing the Panels.
1/4”
1/4” 878PHPO (3x)
878PHPO (3x)
CST 956
CST 993
INLINE
PANEL
CST 998
CST 998
Inside Shower Enclosure
CST 998
CST 998
CST 993
CST 956
INLINE PANEL
878PHPO (3x)
878PHPO (3x)
K2
K3
K1
K2
K4
INSIDE
HANDLE
➢ Locate existing holes for the Handle on the Door Panel.
➢ Loosen Set Screws (K4) and separate the Inside
Handle. Remove Cone Head Screws (K1) from the
Outside Handle.
➢ Slip a Washer (K2) and Bushing (K3) onto each Screw
(K1).
➢ Insert a Screw (K1) through the upper hole in the Door
from inside the enclosure. Slip a second Washer (K2)
onto the Screw (K1).
➢ Tighten the Screw (K1) to the Outside Handle.
➢ Repeat for the second Screw (K1).
➢ Take the Inside Handle and insert it over the heads of
the Screws (K1). Tighten the two Set Screws (K4).
Inside Shower Enclosure
OUTSIDE
HANDLE
DOOR
GLASS
STEP 13. INSTALL DOOR HANDLE
9/64” PILOT HOLES
11
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
STEP 14. PREPARE DRIP RAIL ASSEMBLY
➢ Notch the Door Sweep C 176 C on one end (hinge side) 3/4” x 1/4” as shown.
➢ Insert the Sweep into the channel at the bottom of the Drip Rail CST 927 with the notched end on
the hinge side. Pull the Sweep through until 1” extends from the Drip Rail on the hinge side. Trim
the excess on the strike side.
➢ Insert the left / right Drip Rail Plug CP933 into each end of the Drip Rail.
➢ On the hinge side punch out the center of the Plug to allow water to escape.
CST 927
C 176 C
CP933 (L/R)
Remove center of PLUG on hinge side
3/4”
1/2”
CST 927
C 176 C
1/4”
DOUBLE
SIDED TAPE
DRIP RAIL ASSEMBLY
12
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
➢ Remove the backing from the Tape on the Drip Rail CST 927. Position the Drip Rail flush with the edge of the Door
Panel on the hinge side.
➢ Adjust the height of the Drip Rail to 1” down from the top of the bottom horizontal rail. The Drip Sweep C 176 C will touch
the Sill Cover Dam CST 991 to prevent splash to the outside of the enclosure.
➢ Angle the Drip Rail up at the Door Strike to create a slope of minimum 1/8” down towards the Hinge for drainage.
➢ Check for interference between the Sweep and the unit by opening and closing the Door. Trim and adjust as needed.
➢ When satisfied, secure the Drip Rail to the Door using (2) self-drilling Drip Rail Screws 638PHPTO (#6 x 3/8” Pan Head
Philips Tek (Black Head)) with one at 1” from each end.
DOOR HINGE
DOOR STRIKE
638PHPTO (2x)
DRIP RAIL ASSEMBLY
DOOR HINGE DOOR STRIKE
1”
7/8”
1”
1”
DRIP RAIL SLOPED:
7/8” AT STRIKE
1” AT HINGE
DRIP RAIL ASSEMBLY
638PHPTO (2x)
CST 927
C 176 C
DOOR PANEL
CST 991 DRIP RAIL &
PANEL FLUSH DRIP RAIL &
PANEL FLUSH
STEP 15. INSTALL DRIP RAIL ASSEMBLY
Inside
Shower
Enclosure
GLASS
DRIP RAIL &
PANEL FLUSH
Inside Shower Enclosure
1”
Inside Shower
Enclosure
13
GRIDSCAPE DOOR w. INLINE PANEL
INSTALLATION INSTRUCTIONS – FULL DIVIDED-LIGHT
STEP 16. SEAL UNIT EXTERIOR
➢ To complete the installation, run a bead of clear (or
matching color) mildew resistant caulking around
the outside perimeter of the shower at the Sill CST
998 and the Wall Jambs CST 956 and CST 993.
Outside Shower
Enclosure
CST 956
CAULKING
CST 993
CST 998
➢ Caulk the crevices where the Strike Post CST 926 and
Door Hinge Post meet the Sill Cover Dam CST 991.
➢ Follow the caulking manufacturer’s instructions before
using the shower.
CST 991
CST 926
CAULKING
Inside
Shower
Enclosure
CAULKING