Fully Integrated 36” MasterCool
All Refrigerator:
K 2901 Vi / K 2911 Vi
All Freezer:
F 2901 Vi / F 2911 Vi
Bottom Mount:
KF 2901 Vi / KF 2911 Vi
French Door:
KF 2981 Vi
8mieleusa.comSpecification Sheets TRS 05202019 Please note: This information is subject to change
Shown: KF 2981 Vi
Fully Integrated 36” MasterCool
Please note the following:• This specification sheet is for a single built-in unit.• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specification sheet. *If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of the Heating Mat/Merge Kit.
SPECIFICATIONS
Overall Unit Dimensions 353/4” (908 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Depth does not include door panel]
Niche
Minimum Cabinet Niche Opening 36” (915 mm) W* x 84” - 853/16” (2134 - 2164 mm) H x 243/4” (629 mm) D
Electrical K 29x1 Vi F 29x1 Vi KF 29x1 Vi
Electrical Requirements110V / 120V, 60Hz, 15 Amps
In the case of side-by-side installations, a separate outlet must be used for each appliance.
Power Cord NEMA 5-15 plug, 5 ft (1.52 m)
Plumbing K 29x1 Vi F 29x1 Vi KF 29x1 Vi
Water Supply Requirements -
Connect to a cold water supply only. Do not connect to a low-mineral or a reverse osmosis system. Must be connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pres-sure must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi (8.3 bar), a pressure reducing valve must be installed.
Water Connection Line - Standard 1/4” O.D flexible water line. The maximum outer diameter of the water pipe (without fittings): 3/8” (10 mm). Water line is not included.
Shipping K 29x1 Vi F 29x1 Vi KF 29x1 Vi
Shipping Weight 435 lbs (197 kg) 462 lbs (210 kg) 507 lbs (230 kg)
Shipping Dimensions 40” (1016 mm) W x 8913/16” (1,294 mm) H x 291/4” (800 mm) D
Support
Call Miele (800) 999-1360
Miele Website 8www.mieleusa.com
20/20 Link 82020technologies.com
K 2901 Vi (Right Hinged)Item 36290101USA
K 2911 Vi (Left Hinged)Item 36291101USA
F 2901 Vi (Right Hinged)Item 37290101USA
F 2911 Vi (Left Hinged)Item 37291101USA
KF 2901 Vi (Right Hinged)Item 38290101USA
KF 2911 Vi (Left Hinged)Item 38291101USA
Page 2 of 12
KF 2981 Vi (French Door)Item 38298101USA
CUTOUT DIMENSIONS
• Niche depth assumes a 3/4” (19 mm) panel, please adjust according to custom panel thickness
Fully Integrated 36” MasterCool
CUTOUT DETAILS
• The electrical connection must not be positioned higher than 9” (228.6 mm) above the floor.
• The 1/4” (6.4 mm) plumbed water connection should not be positioned higher than 2” (50.8 mm) above the floor.
Notes:In case of an emergency the electrical outlet must be easily accessible and must not be concealed behind the appliance.
Page 3 of 12
POWER SUPPLY AND WATER CONNECTION(Water Connection For F 29x1 Vi & KF 29x1 Vi Only)
Fully Integrated 36” MasterCool
Water connection is located in front of unit.1/4” compression fitting is needed.
Electrical - 5 foot (1.52 m) - 120 Volt - 15 Amp - NEMA 5-15 molded plugWater line - 1/4” flexible water line - not included
Rear View Front View
Electrical Connection
Side View
Page 4 of 12
CUSTOM PANEL INSTALLATIONS
Width: 29 3/4" in all cases
Thickness: Minimum 3/4" outside frame
Height: Determined using the following calculation:
Panel Height = HOC - TKH
HOC = Total height of cabinet or side panelTKH = Toe-kick height
Note: Finish back side of panels to insure appearancePanel may extend above unit. This is notconsidered in height calculation
Maximum panel weight: 105.8 Pounds
MieleFully Integrated
Freezer
TKH
HO
C
Pane
l Hei
ght
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied bythe cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surroundingcabinets.
Panel size is determined in the following manner:
Panel NotesIf the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly.Simply maintain the toekick height and extend the panel the needed distance.
Adjoining cabinet
Machine
Extended Panel
106 Pounds
Minimum 35 3/4” (908 mm)
Minimum 3/4” (19 mm) outside frame
Fully Integrated 36” MasterCool | K 29x1 Vi & F 29x1 Vi
Page 5 of 12
Fully Integrated 36” MasterCool | K 29x1 Vi & F 29x1 Vi
DOOR PANEL DIMENSIONSKFP 3604 - Door Panel
Available as an accessoryfor the following models:• K 29x1 Vi• F 29x1 Vi
Page 6 of 12
Pan
el "
B"
Hei
ght
Width: 29 3/4" in all casesThickness: Minumum 3/4" outside frame
Standard Upper Panel Height: 53 5/16"
Note: Finish back side of panels to insure appearancePanel may extend above unit. This is notconsidered in height calculation
Upper Maximum panel weight : 103.6 Pounds
Lower Panel Height: Use the following calculation:
Panel Height = HOM - 53 9/16 - TKH
HOM = Total height of machine. Can be adjusted tomatch adjoining cabinets - typically 84"HOM is adjustable between 83 1/2" - 85 3/8"
TKH = Toe-kick height (2" - 8 3/8")
Lower Maximum panel weight: 22 Pounds
Upper Panel
TKH
HO
M
Pan
el H
eigh
t
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied bythe cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surroundingcabinets.
Panel size is determined in the following manner:
Lower Panel
Upper Panel NotesIf the adjoining cabinets are taller than the height of machine (HOM) - the upper panel may be extended accordingly.Find the difference between height of the adjoining cabinets and the height of machine (HOM) and add to 53 5/16"
Adjoining cabinet
Machine
Extended Panel Example:Ajoining cabinet height: 87"Height of machine: 84"Difference: 3"
Extended panel height: 56 5/16"
CUSTOM PANEL INSTALLATIONS
Pan
el "
B"
Hei
ght
Width: 29 3/4" in all casesThickness: Minumum 3/4" outside frame
Standard Upper Panel Height: 53 5/16"
Note: Finish back side of panels to insure appearancePanel may extend above unit. This is notconsidered in height calculation
Upper Maximum panel weight : 103.6 Pounds
Lower Panel Height: Use the following calculation:
Panel Height = HOM - 53 9/16 - TKH
HOM = Total height of machine. Can be adjusted tomatch adjoining cabinets - typically 84"HOM is adjustable between 83 1/2" - 85 3/8"
TKH = Toe-kick height (2" - 8 3/8")
Lower Maximum panel weight: 22 Pounds
Upper Panel
TKH
HO
M
Pan
el H
eigh
t
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied bythe cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surroundingcabinets.
Panel size is determined in the following manner:
Lower Panel
Upper Panel NotesIf the adjoining cabinets are taller than the height of machine (HOM) - the upper panel may be extended accordingly.Find the difference between height of the adjoining cabinets and the height of machine (HOM) and add to 53 5/16"
Adjoining cabinet
Machine
Extended Panel Example:Ajoining cabinet height: 87"Height of machine: 84"Difference: 3"
Extended panel height: 56 5/16"
104 lbs
HOM - 51 1/2” (1307 mm) - TKH
51 3/8” (1304 mm)
Minimum 35 3/4” (756 mm)Minimum 3/4” (19 mm) outside frame
87” (2210 mm)84” (2134 mm)3” (76 mm)
54 1/2” (1379 mm)
Total height of machine. Can be adjusted to match adjoining cabinets - typically 84” (2133 mm).HOM is adjustable between 84” -85 3/16” (2134 mm - 2164 mm)
Lower Maximum panel weight: 22 lbs
Toe-kick height 2” - 8 3/8” (51 - 212 mm)TKH =
Fully Integrated 36” MasterCool | KF 2901 Vi / KF 2911 Vi
Page 7 of 12
Fully Integrated 36” MasterCool | KF 2901 Vi / KF 2911 Vi
DOOR PANEL DIMENSIONSKFP 3614 - Top PanelKFP 3624 - Bottom Panel
Available as an accessoryfor the following models:• KF 2901 Vi / KF 2911 Vii
Page 8 of 12
Pan
el "
B"
Hei
ght
Width: 29 3/4" in all casesThickness: Minumum 3/4" outside frame
Standard Upper Panel Height: 53 5/16"
Note: Finish back side of panels to insure appearancePanel may extend above unit. This is notconsidered in height calculation
Upper Maximum panel weight : 103.6 Pounds
Lower Panel Height: Use the following calculation:
Panel Height = HOM - 53 9/16 - TKH
HOM = Total height of machine. Can be adjusted tomatch adjoining cabinets - typically 84"HOM is adjustable between 83 1/2" - 85 3/8"
TKH = Toe-kick height (2" - 8 3/8")
Lower Maximum panel weight: 22 Pounds
Upper Panel
TKH
HO
M
Pan
el H
eigh
t
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied bythe cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surroundingcabinets.
Panel size is determined in the following manner:
Lower Panel
Upper Panel NotesIf the adjoining cabinets are taller than the height of machine (HOM) - the upper panel may be extended accordingly.Find the difference between height of the adjoining cabinets and the height of machine (HOM) and add to 53 5/16"
Adjoining cabinet
Machine
Extended Panel Example:Ajoining cabinet height: 87"Height of machine: 84"Difference: 3"
Extended panel height: 56 5/16"
CUSTOM PANEL INSTALLATIONS
104 lbs
HOM - 51 1/2” (1307 mm) - TKH
51 3/8” (1304 mm)
Minimum 35 3/4” (756 mm)Minimum 3/4” (19 mm) outside frame
87” (2210 mm)84” (2134 mm)3” (76 mm)
54 1/2” (1379 mm)
Total height of machine. Can be adjusted to match adjoining cabinets - typically 84” (2133 mm).HOM is adjustable between 84” -85 3/16” (2134 mm - 2164 mm)
Lower Maximum panel weight: 22 lbs
Toe-kick height 2” - 8 3/8” (51 - 212 mm)TKH =
Fully Integrated 36” MasterCool | KF 2981 Vi
Page 9 of 12
Minimum 17 13/16” (452.5 mm)
Fully Integrated 36” MasterCool | KF 2981 Vi
DOOR PANEL DIMENSIONSKFP 3634 - Top PanelsKFP 3624 - Bottom Panel
Available as an accessoryfor the following models:• KF 2981 Vi
Page 10 of 12
HINGING DETAILS
HINGING DETAILS 115° OPENING
Fully Integrated 36” MasterCool
Available for the following models:• K 29x1 Vi• F 29x1 Vi• KF 29x1 Vi
Page 11 of 120-1/8"
Front Panel
1"1-1/4"
1-1/2"
0-3/4"
0-3/4"
1-1/4"1-1/2"1-3/4"2" 1"
Cabinet Front
0-3/4"
1"1-1/4"1-1/2"
0-1/8"
FrontPanel
0-3/4"
1-1/4"1-1/2"1-3/4" 1"
Cabinet Front
rooD °511rooD °09
snoitpo ssenkcihTsnoitpo ssenkcihT
Door Swing
NOTE: Additional space needed depending onthickness of front panels and handle used
38 11
/16"
7/16"
Door Swing
16 7/8"MAX
NOTE: Additional space needed depending onthickness of front panels and handle used
3”(76.2mm)
1-3/4”(44.5mm)
1-3/8”(35mm
)1-1/6” (29.6m
m)
1/4”(6.4mm
)17/24” (18m
m)
2-1/24”(52mm)2-1/3” (59mm)2-5/8” (67mm)
3”(76.2mm)
1-3/4”(44.5mm)
1-3/8”(35mm
)1-1/6” (29.6m
m)
1/4”(6.4mm
)17/24” (18m
m)
2-1/24”(52mm)2-1/3” (59mm)2-5/8” (67mm)
0-3/4” (19 mm
)1” (25 m
m)
1-1/4” (32 mm
)1-1/2” (38 m
m)
1-3/4” (44 mm
)
1-1/2” (38 mm)
1-1/4” (32 mm)
1” (25 mm)
0-3/4” (19 mm)
0-1/8” (3 mm)
0-1/8"
Front Panel
1"1-1/4"
1-1/2"
0-3/4"
0-3/4"
1-1/4"1-1/2"1-3/4"2" 1"
Cabinet Front0-3/4"
1"1-1/4"1-1/2"
0-1/8"
FrontPanel
0-3/4"
1-1/4"1-1/2"1-3/4" 1"
Cabinet Front
rooD °511rooD °09
snoitpo ssenkcihTsnoitpo ssenkcihT
Door Swing
NOTE: Additional space needed depending onthickness of front panels and handle used
38 1
1/16
"
7/16"
Door Swing
16 7/8"MAX
NOTE: Additional space needed depending onthickness of front panels and handle used
DOOR SWING AT 115° OPENING 11 3/4”(298 mm)
MaxAvailable for the following models:• K 29x1 Vi• F 29x1 Vi• KF 2901 Vi / KF 2911 Vi
HINGING DETAILS 90° OPENING
Specification Sheets TRS 05202019
Fully Integrated 36” MasterCool
Available for the following models:• K 29x1 Vi• KF 29x1 Vi
Page 12 of 12
0-1/8"
Front Panel
1"1-1/4"
1-1/2"
0-3/4"
0-3/4"
1-1/4"1-1/2"1-3/4"2" 1"
Cabinet Front
0-3/4"
1"1-1/4"1-1/2"
0-1/8"
FrontPanel
0-3/4"
1-1/4"1-1/2"1-3/4" 1"
Cabinet Front
rooD °511rooD °09
snoitpo ssenkcihTsnoitpo ssenkcihT
Door Swing
NOTE: Additional space needed depending onthickness of front panels and handle used
38 11
/16"
7/16"
Door Swing
16 7/8"MAX
NOTE: Additional space needed depending onthickness of front panels and handle used
7/16”(11 mm)
1-3/16”(30mm)
1-7/16”(36.5mm)
1-11/16”(43mm)
1-15/16”(49.2mm)
Handle or object that is NOT flush with Cabinet Front.
0-3/4” (19 mm
)1” (25 m
m)
1-1/4” (32 mm
)1-1/2” (38 m
m)
1-3/4” (44 mm
)2” (51 m
m)
0-3/4” (19 mm)
1” (25 mm)
1-1/4” (32 mm)
1-1/2” (38 mm)
0-1/8” (3 mm)
When installing hinge side next to an appliance or object that is within range of the door panel, limit the door opening angle to 90°. This is done by installing the banking pin as illustrated. Insert the banking pin through the holes and drive in with a hammer.
0-1/8"
Front Panel
1"1-1/4"
1-1/2"
0-3/4"
0-3/4"
1-1/4"1-1/2"1-3/4"2" 1"
Cabinet Front0-3/4"
1"1-1/4"1-1/2"
0-1/8"
FrontPanel
0-3/4"
1-1/4"1-1/2"1-3/4" 1"
Cabinet Front
rooD °511rooD °09
snoitpo ssenkcihTsnoitpo ssenkcihT
Door Swing
32 1
1/16
"
7/16"
Door Swing14 3/8"MAX
NOTE: Additional space needed depending on the thicknessof front panels and handle used.Freezer units cannot be stop pinned at 90°
NOTE: Additional space needed depending on the thicknessof front panels and handle used.Freezer units cannot be stop pinned at 90°
0-1/8"
Front Panel
1"1-1/4"
1-1/2"
0-3/4"
0-3/4"
1-1/4"1-1/2"1-3/4"2" 1"
Cabinet Front
0-3/4"
1"1-1/4"1-1/2"
0-1/8"
FrontPanel
0-3/4"
1-1/4"1-1/2"1-3/4" 1"
Cabinet Front
rooD °511rooD °09
snoitpo ssenkcihTsnoitpo ssenkcihT
Door Swing
NOTE: Additional space needed depending onthickness of front panels and handle used
38 1
1/16
"
7/16"
Door Swing
16 7/8"MAX
NOTE: Additional space needed depending onthickness of front panels and handle used
DOOR SWING AT 90° OPENING 7/16” (11 mm)
38 11
/16” (
982
mm
)
Available for the following models:• K 29x1 Vi• KF 2901 Vi / KF 2911 Vi