YOU ARE DOWNLOADING DOCUMENT

Please tick the box to continue:

Transcript
Page 1: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

0 0KMeasurement of L

KOPIOπ νν→

Douglas BrymanUniversity of British Columbia

April 22, 2004 DOE OHEP Review of the BNL High Energy Physics Program

Page 2: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

CP

2*

"Jarlskog invariant" J

12

Im2 ts tdV VA λλ

= −

Standard Model CP Violation

Super-clean processes will challenge the Standard Model:

*

*

| | , CKM

949

KOIm( ) PIOt

s

s td

L t td

VVVK

Vπ νπ νν

ν0 0

+ +

Κ

E

Page 3: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

: Standard ModelK πνν→Negligible long distance effects. Top quark domiHadronic matrix elements (K ) fr

nancom

e.K e .π π ν→ →

s W +

t t

νν νν

( )0L

0

-11 8.0 1.1 Branching Ratio 10

Theoretical Uncert. (est.)

3.2 0.6

7% 2%

π νν π νν+ +

± ±

Κ → Κ →

u u

Z

d sW +

t

W +

u u

Z

d

d

W +

s νW +

ν, ,e µ τu

t

Buchalla and Buras, Nucl. Phys. B548, 309 (1999); Buras et al.,hep-ph/0402112; Isidori,hep-ph/307014.

Page 4: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Roles of K Measurements in Flavor Physicsπνν→

* ew physics could be revealed K .

:

*

New flavor physics in the sector may be very different from that in the secto b r:

s-d

If B - physics is consistent with the SM

IN πνν→

K would add crucial additional information; the complexity of the flavor sector beyond the SM

:

is

f deviations from the SM are indicated

πνν→

foreseen in many models.

Page 5: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

SK andψ π ν ν→ →B K

SM

Differences sensitive to new physics – virtually free of uncertainties.

SCP asymmetry in Kψ→B

0 0

+

( )( )

L π ννπ νν+

Γ →Γ →

KK

0

+

+ 0

0L

L

(Buras et al. hep-ph/040211)

(Buras hep-ph/0310208)

"Enhanced" Z Penguins (K ) x 1; (

Minimal Fl

K )

av

or Viol.(K ) x 2; (K ) x 4

Multiple Higgs

Low

*

*

** Extra

x 12sin(

dimensi

2 )

on

0.69

s* energy

βΓΓ

Γ

= −

Γ

X

SUSY

*

*

Nir and Worrah, Phys. Lett. ,319 (1998)B423

Page 6: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

0 0Experiments seeking K π νν→

0 00 0

0[ , ]

9( )R( ) 1.4 10

( )

[ Limit based on isospin and :

]LL

L

Grossman NirK

K xK all

νπ ν

π ν

π νν+ +

−Γ →→ ≡ <

Γ →

10 9

75.9 10

10 10

12

KTEV (FNAL) result:

KEK E391a : s.e.s.

KOPIO (BN 10 , >50 eventsL) : s.e.s.

x

goal

goal

− −

<

−• <

KOPIO seeks an improvement of 105 over present results.

Page 7: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

0 0 0 3L 0 2L 0 0L

10

10

0.93

0.36

0.1255

Mode Branching RatK

K

K Others

i

o

0 0 Measurement Primary Backgrounds

x

xe

LK

π ππ νγπ π π

π νν

− + −

+ −

Page 8: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

KOPIO: Measurement of K0L → π0νν̄

CONCEPTS

• Measure as much as possible:

Energy, position and ANGLE of each photon.

• Work in the C.M. system :

Use TOF to get the K0L momentum.

• Maximize Photon Veto Efficiency

• Maximize Intensity of Microbunched Beam

Page 9: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

-3 -2

100 Tp/spill (Upgraded from present 70 Tp)2.7 s spill, 2.3 s interspill period25 MHz micro-buching frequencyBunch width 200psInte

Prot

rbunch extinction 10 1

on Beam:

"Kaon Be0

42.5 degrea

em"

k:

ta

8 L

11

e-off angle Soft momentum spectrum [0.5,1.5 GeV] 10 K / spill, 12 % decay

10 neutrons / spill

Nominal BeamParameters

Page 10: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

KOPIO Beam and Constraints

Page 11: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Shashlyk calorimeter

2 X0 Preradiator

Beam γ veto

Scintillator

Paper + lead+ paper

WLS fiber

PM tube

50 m steeltapes

Vacuumtank

DS Veto

Barrel, US Veto

CP veto

Page 12: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

0 0LK π νν→

Preradiator

0π γγ→+ -Reconstruct first e e

in "Preradiator" to point toK decay vertex in vacuum.

γ →

Calorimeter

Page 13: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

K π νν+ +→KOPIO Technique: Lessons from

Common Problem: Similar background processes exceed signal >1010

• Measure everything! (energy, position, angle, time)• Eliminate extra charged particles or photons

* E949 π0 inefficiency < 10-6

* KOPIO π0 inefficiency < 10-8

• Suppress backgrounds below the signal * Predict backgrounds from data: dual cuts* Use “Blind analysis” techniques * Test predictions “outside-the-box”

• Evaluate candidate events with S/N function

Page 14: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

0949 Veto and Kinematics (P,R,E...)

Veto Reversed Veto AppliedRa

n

Ba

ge vs. Energy Momentum

Dual cutsckground Suppression

:E π π

γγ γ

+ +→K

Max. vetoγ

Check for correlations

Page 15: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Missing mass (2Emiss1 Emiss

2 cosθ12) vs.Missing energy (Emiss

1 + Emiss2 )

0 0 0L K π π→Photon vetoing & Kinematics:

Suppress events with low energy photons

4 4 80 (10 )(10 ) 10πε − − −< = 0 0L K π νν→

KEK Photonuclear

2

4

~ 10 (20-100 MeV) ~ 10 (100-220 MeV)

60 10

γε

πε

−<

E787

Photon Vetoing

Page 16: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Charged Particle Vetoing0Example Background: L eπ νγ− +→K

signal in 4 below 200 keV

π−

π+

185 290 Momentum (MeV/c)

10-5

10-4

10-3

ε

PSI Measurement(Preliminary)

Data

MC

KOPIO Goal 4

5

4

4

NIM 359, 478 (1995)

KEK: 1 GeV/c________________________

Particle (3.2 0.9) 10

1.6 101.3 10

(6.0 0.6) 10________________________

e xx

e xx

ε

π

π

+ −

+ −

− −

− −

±

<

<

±

A

Plastic Scintillator

Page 17: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Key features of the KOPIO concept have been established:• Micro-bunching• Photon pointing, energy resolution• Vetoing – including charged particles, photons, catcher

Page 18: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High
Page 19: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Kinematic suppression of backgroundsGoal: >50 Events with S/N>2

0* * *

1 2.E vs E Eγ γπ−

0 0L K π νν→

0 0 0L K π π→

Page 20: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

S/N=2

0 0 0 3L 0 2L 0 0L

10

10

0.93

0.36

0.1255

K 14

Estimated Background Levels Branchin

K 5

K 3 Others

g Ratio Bkg. Ev

ents

1

x

xeπ ππ νγπ π π

− + −

+ −

******* Signal: 49 Background: 24

12000 Hours; Acceptance 9 x 10-3

Page 21: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High
Page 22: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

AGS Microbunching Beam testMicrobunch width Interbunch extinction

Measured the inter-bunch extinction ratio(flux between bunches/within bunch).Observed a ratio of ~3-4% (could be less)KOPIO requires ~ 10-3 - 10-2

Need to control power supply ripple

Studied the RF extraction mechanismproposed for KOPIO & measured a microbunch rms width of 244 ps --KOPIO requires a 300 ps rms

Also developed monitoring methods

Page 23: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Vacuum System R&D

Finite elementAnalysis

Current Design:Honeycomb vessel and endsAl core, domed endsSolid Be beam pipe

Page 24: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Neutral Beam (neutrons) Collimated to Supress Halo

Vertical Collimation Scheme

Page 25: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Simulation of Neutron CollimationNominal beam Neutron Energy Spectrum

Page 26: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Prototype Cathode Strip Chamber

Preradiator R&DChambers, electronics, and scintillator prototyped.Mechanical design in progress.

4m

Extruded Scintillatorwith WLS fiber

Page 27: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

KOPIO Prototype Measurements– Tagged Photon Beams

Preradiator Angular resolution:25 mr at 250 MeV/c

Page 28: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Shashlyk R&D

Shashlyk modules prototypedand tested in beams.Mechanical design in progress

APD

Page 29: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Shashlyk Beam Measurements

Simulation: Combined Energy Resolution

3%( )E GeV

σ

Page 30: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

New Aerogel tiles

Catcher R&D

Modules prototyped andtested in beams.

Page 31: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

KOPIO Funding and Support Partners

• NSF• RSVP MREFC and R&D• University groups

• DOE OHEP• BNL Physics Department group• Yale group

• DOE ONP; BNL CAD (and university groups)• Canadian agencies (NSERC, CFI, TRIUMF)• Japanese agencies• Others (Russia, Switzerland, Italy (INFN) )

Page 32: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

DOE-Supported GroupsMajor Responsibilities

• Yale– Shashlyk Calorimeter– Neutral beam and other simulations

• BNL (CAD)– AGS upgrades, proton beam, target– Neutral beam

• BNL (PHYSICS)– Detector infrastructure and integration– Veto detector systems– DAQ system– Simulations

Page 33: Douglas Bryman University of British Columbia · Measurement of K00 L KOPIO →πνν Douglas Bryman University of British Columbia April 22, 2004 DOE OHEP Review of the BNL High

Summary and Outlook

• KOPIO R&D is concluding successfully.• Advanced planning for the construction

phase is beginning.• US Agencies – NSF and DOE – are

cooperating well, and international partners are contributing substantially.


Related Documents