Dioxins & Furans emission measurements
June 2016
at Fortum Klaipeda
KW3 B.V.
Report number: KW3-20160049R02
UAB Fortum Klaipeda, Kretainis str. 3,
Lithuania Relatie nummer.: 96
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
Summary
On 27 of June 2016, KW3 B.V. performed emission measurements at the main stack of a waste incineration plant
on the location of Fortum UAB, Lithuania.
The purpose of the emission measurements was to determine the emission of Dioxins & Furans in the flue gas of
the main stack.
The measurements were performed in accordance with the EN ISO 17020 and EN 15259. The specific standards for each component are described in chapter 2. The sample was analysed under EN ISO 17025.
Table 0.1 Emission dioxins & furans
Installation measurement Dioxins & Furans
Concentratie in ng/Nm3 at 11 % O2
Waste incineration plant 1 < 0.004
The average concentration for the sum of dioxins & furans is below the ELV of 0.1 ng/Nm3 at 11 vol. % O2.
The sample period was at 6 hours and at least 4 m3 of flue gas was led through the XAD cartouche.
Homogeneity tests
Profile measurements have been performed in 2013 and the flue gas at the sampling location is homogeneous.
See report: 7019303r01; 2013.
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
Mailing list
1. Client (Digital)
2. KW3 B.V. archive (1x)
Colophon
Project leader : A. van Meekeren
Author : A. van Meekeren
Quality check calculations and report : M. Noortman
Measurement engineers on-site : B. Oudmaijer
: A. van Meekeren
Client
Name : UAB Fortum
Address : Kretainio street 3, LT-94103, Klaipeda Lithuania
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
TABLE OF CONTENTS
1 INTRODUCTION ............................................................................................................................ 5
1.1 Introduction ........................................................................................................................ 5
2 MEASURING AND SAMPLING SYSTEM ..................................................................................... 6
2.1 Discontinuous measuring system (KW3) ........................................................................ 6
2.2 Quality KW3 B.V. ................................................................................................................ 6
3 Measuring program ...................................................................................................................... 7
3.1 General................................................................................................................................ 7
3.2 Emission program ............................................................................................................. 7
3.3 Description measuring area ............................................................................................. 7
4 results of measurements ............................................................................................................. 9
4.1 Measuring results Dioxins & Furans ............................................................................... 9
5 Uncertainty of measurements KW3 .......................................................................................... 10
5.1 Measuring uncertainty KW3 B.V. ................................................................................... 10
Appendix ............................................................................................................................................. 11
Appendix 1 Schematic of the gas sampling and analysing systems SRM ........................ 11
Appendix 2 Emission results ................................................................................................. 12
Appendix 3 Laboratory results .............................................................................................. 14
Appendix 4 Overview waste incineration plant ..................................................................... 17
Appendix 5 Accreditation certificate KW3 B.V. ..................................................................... 18
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
1 INTRODUCTION
1.1 Introduction
On 27 of June 2016, KW3 B.V. performed emission measurements at the main stack of a waste incineration plant
on the location of Fortum UAB, Lithuania.
The purpose of the emission measurements was to determine the emission of Dioxins & Furans in the flue gas of
the main stack.
The measurements were performed in accordance with the EN ISO 17020 and EN 15259. The specific standards
for each component are described in chapter 2. The sample was analysed under EN ISO 17025.
In chapter 2 and 3 a description of the measurement system and the measurement program is presented. In
chapter 4 the results and the calculations of the tests are presented. The accuracy of the results is discussed in
chapter 5.
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
2 MEASURING AND SAMPLING SYSTEM
2.1 Discontinuous measuring system (KW3)
Dioxins/ Furans
The dioxins & furans sampling were performed using the so-called condensation method. Via a cooled glass
measuring probe an isokinetic part stream from the waste gases was sucked through a XAD-2 cartridge. The
concentration of 17 PCDDs and PCDFs is then determined in a laboratory through high resolution mass
spectrometry gas chromatography.
The sampling is conducted in accordance with EN 1948-1. A schematic representation of the sampling system is
shown in appendix 1, figure 1.
Humidity flue gas
During the measurements flue gas is led through cooled glass bottles (impingers) to collect the water from the
flue gas. Before the measurement the impingers are weighted and after each measurement the impingers are
weighted again. Together with the exact known volume led through the impingers the humidity is calculated.
A schematic representation of the sampling system is shown in appendix 1, figure 2.
The sampling is conducted in accordance with the following European standards:
Table 2.1 EN standards
Component European standard/ method
Dioxins & Furans EN 1948-1
H2O EN 14790:2006
Volume flow ISO 10780
Emission sampling EN 15259:2007
2.2 Quality KW3 B.V.
KW3 B.V. is certified to perform emission measurements according to EN ISO/IEC 17020 (type A)/ ISO 9001 by
the Dutch council of Accreditation (no I304).
KW3 B.V. is certified for measuring NO, NO2, NOx, O2, CO, CO2, SO2, CxHy, dust, Hg, heavy metals (particle-
bound and volatile), gas velocity, gas temperature, gas humidity, flow, HCl, HF, NH3, H2S, CL2, formaldehyde,
dioxins & furans (PCDD/PCDF’s and PAH’s).
All project leaders and field engineers are in possession of a VCA certificate on level “ Safety for Operational
Supervisors Netherlands”.
All used equipment is electrical certified according to EN 1010, EN 50110 and EN 3140.
All inspectors on site are trained in performing emission measurements.
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
3 MEASURING PROGRAM
3.1 General
The purpose of the measurement was to determine the emission concentration of Dioxins & Furans in the flue gas
of the waste incineration plant.
The plant is from UAB Fortum Klaipeda and has a capacity of 255000 tons waste per year. The incinerator is
designed for thermal destruction of solid waste. Herewith the boiler is used to produce steam for generating
electricity.
Before the flue gas is emitted to the air several treatment procedures are involved:
- Injection of NH3 for reducing NOx; - Injection of lime and charcoal; - Further treatment in a condenser.
See appendix 3 for an overview of the waste incineration plant.
3.2 Emission program
In table 3.1 the measuring program is presented.
Table 3.1 Emission measuring program component date measurements period
Dioxins & Furans 27-6-2016 1 11:56 – 17:56
3.3 Description measuring area
Table 3.2 Description measuring area
Parameters position measuring surface
Criteria
Placement stack at measuring surface vertical horizontal / vertical
distance after disturbance compliant > 5 x Dn.
distance straight duct after measuring surface compliant > 2 x Dn.
distance till outlet stack compliant > 5 x Dn.
Parameters for flow criteria Criteria
Minimum velocity compliant > 5 m/s en < 50 m/s
Direction flue gas compliant < 15º tov lengte-as
Fluctuations per point in flue gas compliant < 24 Pa
Dynamic and static pressure compliant P > 5 Pa
Distribution velocity in measuring surface compliant average velocity per ax < 5% of total average
Deviation temperature compliant < 5% of average
Parameters for dust criteria Criteria
Minimum velocity compliant > 2 m/s
Direction flue gas compliant < 15º tov lengte-as
Ratio highest and lowest velocity compliant Vmax / Vmin < 3
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
The measuring surface is placed in the vertical duct. Access to the measuring ports via stairs. The measuring
surface is at the same level as the AMS at 20 meters height.
Table 3.3 Result homogeneity test (report 7019303r01: 2013)
NOx O2 SO2
flue gas Homogene Homogene Homogene
test value (ELV /average concentration) 70 mg/Nm3 21 vol% 750 mg/Nm3
required uncertainty 10 % 6 % 20.0 %
7 mg/Nm3 1.3 vol% 150 mg/Nm3
required sample type point point point
representative measuring point any point any point any point
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
4 RESULTS OF MEASUREMENTS
4.1 Measuring results Dioxins & Furans
In table 4.1 the emission results for dioxins & furans are given at actual O2 vol. % and at 11 vol. % O2. In
appendix 2 an extended overview is given of the emission measurements.
Table 4.1 Emission measuring results
Concentrations at actual O2 vol% at 11 vol% O2
2,3,7,8 Tetra CDD (filter) ng/mn3 0.000 0.000
1,2,3,7,8 Penta CDD (Filter) ng/mn3 0.001 0.001
1,2,3,4,7,8 Hexa CDD (Filter) ng/mn3 < 0.001 < 0.001
1,2,3,6,7,8 HexaCDD (filter) ng/mn3 0.007 0.005
1,2,3,7,8,9 Hexa CDD (Filter) ng/mn3 0.002 0.002
1,2,3,4,6,7,8-Hepta CDD (filter) ng/mn3 0.066 0.045
Octa CDD (filter) ng/mn3 0.087 0.060
2,3,7,8-Tetrachloordibenzofuraan (filter) ng/mn3 0.009 0.006
1,2,3,7,8 Penta CDF (Filter) ng/mn3 0.003 0.002
2,3,4,7,8-Penta CDF (filter) ng/mn3 0.003 0.002
1,2,3,4,7,8 Hexa CDF (Filter) ng/mn3 0.001 0.001
1,2,3,6,7,8 Hexa CDF (Filter) ng/mn3 < 0.001 < 0.001
1,2,3,7,8,9 Hexa CDF (Filter) ng/mn3 < 0.001 < 0.001
2,3,4,6,7,8 - Hexa CDF (filter) ng/mn3 < 0.001 < 0.001
1,2,3,4,7,8,9 -Hepta CDF (filter) ng/mn3 0.003 0.002
1,2,3,4,6,7,8 Hepta CDF (Filter) ng/mn3 < 0.001 < 0.000
Octa CDF (Filter) ng/mn3 < 0.006 < 0.004
TEQ volgens NATO/CCMS (filter) incl. <nd componenten ng/mn3 < 0.006 < 0.004
Measured O2 in flue gas [vol %] 6.52
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
5 UNCERTAINTY OF MEASUREMENTS KW3
5.1 Measuring uncertainty KW3 B.V.
In the presentation of the emission components, which are sampled and analysed, several sources of errors can be
determined. Those are adding up to the inaccuracy of the measurement.
The measurement uncertainty indicates the uncertainty of a measured value. Each carried out measurement has a
certain degree of uncertainty. There’s a working method developed within the VKL (Dutch association of quality
air measurements) to determine the measurement uncertainties per component. The measurement uncertainty is
presented as a 95% confidence interval.
Table 5.1 Measuring uncertainty KW3
General
Company KW3
Project name Emission at UAB Fortum Klaipeda
Project number 20160049
location Stack waste incineration plant
Measurement performed by BO & AvM
Calculations performed by AvM
Debiet eenheid resultaat meetonzekerheid
[absoluut] [%]
Snelheid rookgas m/s 16.57 1.42 8.6
Debiet Nm3/h 152460 15617 10.2
Continue meting eenheid resultaat meetonzekerheid
[absoluut] [%]
O2 vol.% 6.5 0.24 3.7
Discontinue meting fase eenheid resultaat meetonzekerheid
[absoluut] [%]
PCDD/F totaal ng T.E.Q/Nm3 0.006 0.001 20.4
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
APPENDIX
Appendix 1 Schematic of the gas sampling and analysing systems SRM
Figure 1 Overview Dioxins & Furans sampling system.
Figure 2 Overview H2O sampling system.
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
Appendix 2 Emission results
Company UAB Fortum Equipment KW3-134
Emission source stack
Date 27-Jun-16
Component Dioxins & Furanes
Software version Software versie 5.10 (juni 2016)
Measurement 1
Measuring date 27-Jun-16
Measurement period from [hour] 11:56
til [hour] 17:56
Measuring time [min] 06:00
Atmospheric pressure [mbar] 1012
Diameter duct [m] 2.4
Surface duct [m2] 4.52
S-pitot factor [-] 0.809
Measuring points per ax [-] 8
Static pressure flue gas [mbar] -1.4
Temperature flue gas [°C] 147
Velocity flue gas (S-pitot) wet [m/s] 16.6
Flue gas flow at process conditions wet [m3/h] 269900
Flue gas flow at standard conditions dry [Nm3/h] 143159
Aspirated volume gasmeter dry [m3] 7.103
Temperature gas meter [°C] 24
pressure gas meter [mbar] 0.0
Aspirated volume gasmeter dry [Nm3] 6.520
Humidity flue gas dry [g/Nm3] 178.6
Humidity flue gas [vol.%] 21.4
Mass flow water [kg/h] 25561
Nozzle diameter [cm] 0.65
Bepaling van isokinetiek
Sampling time [sec.] 21600
Flow through nozzle dry [Nm3/s] 0.00030
dry [m3/s] 0.00047
wet [m3/s] 0.00056
Surface nozzle [m2] 3.32E-05
Velocity nozzle wet [m/s] 17.02
Isokinetiek factor [-] 1.03
Absorptiematriaal [-] XAD-2
Cartouchenummer [-] 0.0
Measured O2 in flue gas [vol %] 6.52
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
Concentrations at actual O2 vol% 11 vol% O2
2,3,7,8 Tetra CDD (filter) ng/mn3 0.0005 0.0003
1,2,3,7,8 Penta CDD (Filter) ng/mn3 0.001 0.001
1,2,3,4,7,8 Hexa CDD (Filter) ng/mn3 < 0.001 < 0.001
1,2,3,6,7,8 HexaCDD (filter) ng/mn3 0.007 0.005
1,2,3,7,8,9 Hexa CDD (Filter) ng/mn3 0.002 0.002
1,2,3,4,6,7,8-Hepta CDD (filter) ng/mn3 0.066 0.045
Octa CDD (filter) ng/mn3 0.087 0.060
2,3,7,8-Tetrachloordibenzofuraan (filter) ng/mn3 0.009 0.006
1,2,3,7,8 Penta CDF (Filter) ng/mn3 0.003 0.002
2,3,4,7,8-Penta CDF (filter) ng/mn3 0.003 0.002
1,2,3,4,7,8 Hexa CDF (Filter) ng/mn3 0.001 0.001
1,2,3,6,7,8 Hexa CDF (Filter) ng/mn3 < 0.001 < 0.001
1,2,3,7,8,9 Hexa CDF (Filter) ng/mn3 < 0.001 < 0.001
2,3,4,6,7,8 - Hexa CDF (filter) ng/mn3 < 0.001 < 0.001
1,2,3,4,7,8,9 -Hepta CDF (filter) ng/mn3 0.003 0.002
1,2,3,4,6,7,8 Hepta CDF (Filter) ng/mn3 < 0.001 < 0.000
Octa CDF (Filter) ng/mn3 < 0.006 < 0.004
TEQ volgens NATO/CCMS (filter) incl. <nd componenten ng/mn3 < 0.006 < 0.004
TEQ volgens NATO/CCMS Upper bound (filter) excl. < ng/mn3 0.005 0.004
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
Appendix 3 Laboratory results
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
Appendix 4 Overview waste incineration plant
UAB “Bureau Veritas Lit”
Ukmergės g. 369A
LT-12142 Vilnius
Tel. (8 5) 239 50 70
Faks. (8 5) 239 51 55
El. paštas [email protected]
Įm. kodas: 111512921
PVM m.k. LT115129219
www.bureauveritas.lt
Appendix 5 Accreditation certificate KW3 B.V.
Napájadlá 17, 040 12 KošiceIČO:31684165 tel. : 055/6411211, e-mail : [email protected]
RESULT OF THE ANALYSIS No. 5117/2016
Page : 1 / 3EKO-TERM SERVIS s.r.o.Napájadlá 11/2743040 12 Košice
Name saple : PUF 1 + filter + rinse + condensate Place of sampling : UAB "Fortum Klaipeda", Lithuania, Waste incineration plant Colecion of samples:EKO TERM -SERVIS s.r.o,Košice Date of service: 18.11.2016Sampling method: STN EN 1948-1 Date of colection : 7.11.2016Sampel charecteristic : emisie Termination date : 1.12.16
The analysis results are to the subject matter of the analysis and not replace any other documents.Without written approval of the testing laboratory this certificate may by reproduced as a whole only.
Results of testsParameter Unit Sample No. 16010000 Method
Value suma PCDD/F ng TEQ/sample 0,9668 A STN EN 1948-3:2006
Sample analysed : Ing. E. Jusková
A/N : acredited / not acredited
uncertainty U K=2 (95% probability)
Note on sampling: Sampling is not covered by this Protocol
Košice, dated: 1.12.2016
Head chemist: Ing. Eva Jusková
Autorized: ............................. Ing. Eva Jusková
Head manager of the laboratory
IČO : 31 684 165 P 12
Page No.2 / 3Protocol No. 5117/2016 Sample No.: 16010000
Order No : 1980/16
Partial results: Page No: 2/3
I-TEF Contcent.PCDD/F ng/sample. Contcent. PCDD/F ngTEQ/sample .
2378TCDD 1 0,019 0,0190
12378PeCDD 0,5 0,161 0,08065
123478HxCDD 0,1 0,595 0,0595
123678HxCDD 0,1 1,863 0,1863
123789HxCDD 0,1 0,912 0,09122
1234678HpCDD 0,01 15,810 0,15810
OCDD 0,001 12,260 0,012260
Suma PCDD 31,6206 0,607
2378TCDF 0,1 <0,004 <0,0004
12378PeCDF 0,05 0,125 0,006255
23478PeCDF 0,5 0,074 0,03675
123478HxCDF 0,1 0,406 0,04062
123678HxCDF 0,1 0,627 0,06273
234678HxCDF 0,1 1,416 0,1416
123789HxCDF 0,1 0,361 0,03613
1234678HpCDF 0,01 3,456 0,0346
1234789HpCDF 0,01 <0,010 <0,0001
OCDF 0,001 1,207 0,001207
Suma PCDF 7,6718 0,3598
Suma PCDD/F 39,2924 0,9668
Limit of quantification - shown in the table as the value of <
EQ value is given by the sum of the values of the concentrations of individual PCDD / F by multiplying the I-TEF
If the concentration of the wage determination is to TEQ values calculated LOD
Values of I-TEFpro PCDD / F used by Ministry of Environment Decree 410/2012 Coll
Disclaimer:
Chemical analysis was performed according to the IPP 464 (EN 1948 2.3)
The main difference IPP 464 - type mass detector triple qadrupol
The method was validated under the accreditation criteria.
Page No:2/3 2:
IČO : 31 684 165 P 12
Page No.3 / 3Protocol No. 5117/2016 Sample No.: 16010000
Order No : 1980/16
For validation of the method under the following parameters:
- Expanded uncertainty: 30%
The volume of the sample after concentrating 100 µl
Injection: 2 ml
13C12 standad Typ Extraction
%
2378TCDD Extraction 101
12378PeCDD Extraction 112
123478HxCDD Extraction 114
123678HxCDD Extraction 87
1234678HpCDD Extraction 98
OCDD Extraction 98
2378TCDF Extraction 105
23478PeCDF Extraction 110
123478HxCDF Extraction 98
123678HxCDF Extraction 91
234678HxCDF Extraction 84
1234678HpCDF Extraction 95
OCDF Extraction 88
12378PeCDF Sampling 101
123789HxCDF Sampling 113
1234789HpCDF Sampling 87
The Annex is an integral part of the relevant protocol
It may be reproduced only with this Protocol
Prepared by: Ing. Eva Jusková Ing. Eva Jusková
Chemist Supervisor: Ing. Eva Jusková Head manager of the laboratory
IČO : 31 684 165 P 12
Napájadlá 17, 040 12 KošiceIČO:31684165 tel. : 055/6411211, e-mail : [email protected]
RESULT OF THE ANALYSIS No. 5118/2016
Page : 1 / 3EKO-TERM SERVIS s.r.o.Napájadlá 11/2743040 12 Košice
Name saple : PUF 2 Place of sampling : UAB "Fortum Klaipeda", Lithuania, Waste incineration plant Colecion of samples:EKO TERM -SERVIS s.r.o,Košice Date of service: 18.11.2016Sampling method: STN EN 1948-1 Date of colection : 7.11.2016Sampel charecteristic : emisie Termination date : 1.12.16
The analysis results are to the subject matter of the analysis and not replace any other documents.Without written approval of the testing laboratory this certificate may by reproduced as a whole only.
Results of testsParameter Unit Sample No. 16010001 Method
Value suma PCDD/F ng TEQ/sample <0,008 A STN EN 1948-3:2006
Sample analysed : Ing. E. Jusková
A/N : acredited / not acredited
uncertainty U K=2 (95% probability)
Note on sampling: Sampling is not covered by this Protocol
Košice, dated: 1.12.2016
Head chemist: Ing. Eva Jusková
Autorized: ............................. Ing. Eva Jusková
Head manager of the laboratory
IČO : 31 684 165 P 12
Page No.2 / 3Protocol No. 5118/2016 Sample No.: 16010001
Order No : 1980/16
Partial results: Page No: 2/3
I-TEF Contcent.PCDD/F ng/sample. Contcent. PCDD/F ngTEQ/sample .
2378TCDD 1 <0,004 <0,0040
12378PeCDD 0,5 <0,010 <0,005
123478HxCDD 0,1 <0,010 <0,0010
123678HxCDD 0,1 <0,010 <0,001
123789HxCDD 0,1 <0,010 <0,001
1234678HpCDD 0,01 <0,010 <0,00010
OCDD 0,001 <0,020 <0,000020
Suma PCDD <0,0280 <0,0028
2378TCDF 0,1 <0,004 <0,0004
12378PeCDF 0,05 <0,010 <0,0005
23478PeCDF 0,5 <0,010 <0,005
123478HxCDF 0,1 <0,010 <0,001
123678HxCDF 0,1 <0,010 <0,001
234678HxCDF 0,1 <0,010 <0,001
123789HxCDF 0,1 <0,010 <0,001
1234678HpCDF 0,01 <0,010 <0,0001
1234789HpCDF 0,01 <0,010 <0,0001
OCDF 0,001 <0,020 <0,000020
Suma PCDF <0,0520 <0,0052
Suma PCDD/F <0,0800 <0,008
Limit of quantification - shown in the table as the value of <
EQ value is given by the sum of the values of the concentrations of individual PCDD / F by multiplying the I-TEF
If the concentration of the wage determination is to TEQ values calculated LOD
Values of I-TEFpro PCDD / F used by Ministry of Environment Decree 410/2012 Coll
Disclaimer:
Chemical analysis was performed according to the IPP 464 (EN 1948 2.3)
The main difference IPP 464 - type mass detector triple qadrupol
The method was validated under the accreditation criteria.
Page No:2/3 2:
IČO : 31 684 165 P 12
Page No.3 / 3Protocol No. 5118/2016 Sample No.: 16010001
Order No : 1980/16
For validation of the method under the following parameters:
- Expanded uncertainty: 30%
The volume of the sample after concentrating 100 µl
Injection: 2 ml
13C12 standad Typ Extraction
%
2378TCDD Extraction 99
12378PeCDD Extraction 110
123478HxCDD Extraction 114
123678HxCDD Extraction 96
1234678HpCDD Extraction 107
OCDD Extraction 100
2378TCDF Extraction 104
23478PeCDF Extraction 104
123478HxCDF Extraction 104
123678HxCDF Extraction 92
234678HxCDF Extraction 101
1234678HpCDF Extraction 97
OCDF Extraction 89
12378PeCDF Sampling <1
123789HxCDF Sampling <1
1234789HpCDF Sampling <1
The Annex is an integral part of the relevant protocol
It may be reproduced only with this Protocol
Prepared by: Ing. Eva Jusková Ing. Eva Jusková
Chemist Supervisor: Ing. Eva Jusková Head manager of the laboratory
IČO : 31 684 165 P 12
Napájadlá 17, 040 12 KošiceIČO:31684165 tel. : 055/6411211, e-mail : [email protected]
RESULT OF THE ANALYSIS No. 5119/2016
Page : 1 / 3EKO-TERM SERVIS s.r.o.Napájadlá 11/2743040 12 Košice
Name saple : filter + rinse blank Place of sampling : UAB "Fortum Klaipeda", Lithuania, Waste incineration plant Colecion of samples:EKO TERM -SERVIS s.r.o,Košice Date of service: 18.11.2016Sampling method: STN EN 1948-1 Date of colection : 7.11.2016Sampel charecteristic : emisie Termination date : 1.12.16
The analysis results are to the subject matter of the analysis and not replace any other documents.Without written approval of the testing laboratory this certificate may by reproduced as a whole only.
Results of testsParameter Unit Sample No. 16010002 Method
Value suma PCDD/F ng TEQ/sample <0,008 A STN EN 1948-3:2006
Sample analysed : Ing. E. Jusková
A/N : acredited / not acredited
uncertainty U K=2 (95% probability)
Note on sampling: Sampling is not covered by this Protocol
Košice, dated: 1.12.2016
Head chemist: Ing. Eva Jusková
Autorized: ............................. Ing. Eva Jusková
Head manager of the laboratory
IČO : 31 684 165 P 12
Page No.2 / 3Protocol No. 5119/2016 Sample No.: 16010002
Order No : 1980/16
Partial results: Page No: 2/3
I-TEF Contcent.PCDD/F ng/sample. Contcent. PCDD/F ngTEQ/sample .
2378TCDD 1 <0,004 <0,0040
12378PeCDD 0,5 <0,010 <0,005
123478HxCDD 0,1 <0,010 <0,0010
123678HxCDD 0,1 <0,010 <0,001
123789HxCDD 0,1 <0,010 <0,001
1234678HpCDD 0,01 <0,010 <0,00010
OCDD 0,001 <0,020 <0,000020
Suma PCDD <0,0280 <0,0028
2378TCDF 0,1 <0,004 <0,0004
12378PeCDF 0,05 <0,010 <0,0005
23478PeCDF 0,5 <0,010 <0,005
123478HxCDF 0,1 <0,010 <0,001
123678HxCDF 0,1 <0,010 <0,001
234678HxCDF 0,1 <0,010 <0,001
123789HxCDF 0,1 <0,010 <0,001
1234678HpCDF 0,01 <0,010 <0,0001
1234789HpCDF 0,01 <0,010 <0,0001
OCDF 0,001 <0,020 <0,000020
Suma PCDF <0,0520 <0,0052
Suma PCDD/F <0,0800 <0,008
Limit of quantification - shown in the table as the value of <
EQ value is given by the sum of the values of the concentrations of individual PCDD / F by multiplying the I-TEF
If the concentration of the wage determination is to TEQ values calculated LOD
Values of I-TEFpro PCDD / F used by Ministry of Environment Decree 410/2012 Coll
Disclaimer:
Chemical analysis was performed according to the IPP 464 (EN 1948 2.3)
The main difference IPP 464 - type mass detector triple qadrupol
The method was validated under the accreditation criteria.
Page No:2/3 2:
IČO : 31 684 165 P 12
Page No.3 / 3Protocol No. 5119/2016 Sample No.: 16010002
Order No : 1980/16
For validation of the method under the following parameters:
- Expanded uncertainty: 30%
The volume of the sample after concentrating 100 µl
Injection: 2 ml
13C12 standad Typ Extraction
%
2378TCDD Extraction 97
12378PeCDD Extraction 103
123478HxCDD Extraction 101
123678HxCDD Extraction 94
1234678HpCDD Extraction 91
OCDD Extraction 89
2378TCDF Extraction 98
23478PeCDF Extraction 105
123478HxCDF Extraction 87
123678HxCDF Extraction 83
234678HxCDF Extraction 81
1234678HpCDF Extraction 89
OCDF Extraction 79
12378PeCDF Sampling 91
123789HxCDF Sampling 100
1234789HpCDF Sampling 70
The Annex is an integral part of the relevant protocol
It may be reproduced only with this Protocol
Prepared by: Ing. Eva Jusková Ing. Eva Jusková
Chemist Supervisor: Ing. Eva Jusková Head manager of the laboratory
IČO : 31 684 165 P 12