PRINTED:
PORTLAND, OREGON
DESIGN NUMBER PROJECT NUMBER
PORT OF PORTLANDPORTLAND, OREGON
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17".
DRAWING NO. SHEET NO. DISC. SHT. NO.TYPE
PROJECT ENGINEER
GRANT EVENHUS
SUBMITTED BY
NO. DATE BY REVISIONS APP'VD CK'D NO. DATE BY REVISIONS APP'VD CK'D
PORTLAND INTERNATIONAL AIRPORT
SCALE
DATE
CHECKED BY
DRAWN BY
DESIGNED BY
707 SW Washington Street | Suite 1200Portland, OR 97205
t 503 221 0150 f 503 295 0840
YOST GRUBE HALLARCHITECTURE
NONE
2/5/2020 4:57:00 PM BIM 360://16-1480 - PACR/PDX-xxxx-102170-P3-04-MEP-Main.rvt
M0.004
PARKING AND CONSOLIDATED RENTAL FACILITY
EQUIPMENT SCHEDULE 2 - MECHANICAL
C. MORGAN
S. WRIGHT
D. NACHTRIEB
JAN 2020
2015D038 PDX 2019-500102171 CD xxxx
1 11/27/2019 AS NEGOATIATED
Z 01/31/2020 ADDENDUM 13
1. OUTDOOR CONDITIONS BASED ON ASHRAE FUNDAMENTALS 2013 99.6% AND 0.4% DATA.
NOTE(S):
INDOOR 72˚ F ± 2˚ F DB 50% RH MAX, NO MINIMUM 72˚ F ± 2˚ F DB 50% RH MAX, NO MINIMUM
OUTDOOR 25.2˚ F DB 9.6˚ F DP / 9.0 HR / 29.8 ˚ F MCDB 91.4˚ F DB / 67.3˚ F MCWB 63.2˚ F DP / 87.0 HR / 75.1˚ F MCDB
TEMPERATURE HUMIDITY TEMPERATURE HUMIDITY
SPACE WINTER SUMMER
DESIGN CONDITIONS - PORTLAND, OR:
3. SEE M6.012/1 FOR CONTROL REQUIREMENTS.
2. OCCUPANCY SENSOR LOCATED WITHIN SPACE.
1. COMBINED HUMIDITY, CO2 AND TEMPERATURE STAT PROVIDED.
KEY NOTE(S):
1. VARIABLE AIR VOLUME UNITS
NOTE(S):
VVR-RCC-110-01 RCC 110 BOH VENTILATION 14 2000 600 55.0 75.0 9.9 1.0 110 90 53 TITUS 1, 2
VVR-RCC-108-02 RCC 108 RCC100 14 1900 950 55.0 75.0 24.8 2.5 110 90 53 TITUS 1
VVR-RCC-108-01 RCC 108 RCC100 12 1400 700 55.0 75.0 19.4 1.9 110 90 45 TITUS 1
NUMBER LOCATION SERVICE (IN) CFM CFM (°F) (°F) MBH GPM (°F) (°F) MODEL KEY NOTES
TAG INLET MAX MIN EAT LAT EWT LWTLBS
MANUFACTURER &
AIRFLOW REHEAT COIL UNIT WEIGHT
TERMINAL UNIT SCHEDULE:
1. SEE M6.009/1 FOR CONTROL REQUIREMENTS.
KEY NOTE(S):
UH-RCC-505-03 RCC PENTHOUSE RCC505 CABINET NA NA 0.5 140 30 20 120/1 30 TRANE UHS
UH-RCC-505-02 RCC PENTHOUSE RCC505 CABINET NA NA 0.5 140 30 20 120/1 30 TRANE UHS
UH-RCC-505-01 RCC PENTHOUSE RCC505 CABINET NA NA 0.5 140 30 20 120/1 30 TRANE UHS
UH-RCC-504-01 RCC PENTHOUSE RCC504 CABINET NA NA 0.5 140 30 20 120/1 30 TRANE UHS
UH-RCC-500-02 RCC PENTHOUSE RCC500 CABINET NA NA 0.5 140 30 20 120/1 30 TRANE UHS
UH-RCC-500-01 RCC PENTHOUSE RCC500 CABINET NA NA 0.5 140 30 20 120/1 30 TRANE UHS
EWH-RCC-ST02-01 RCC FLOOR 1 ST02 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-ST01-01 RCC FLOOR 1 ST01 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-404-01 RCC FLOOR 4 RCC404 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-403-01 RCC FLOOR 4 RCC403 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-401-01 RCC FLOOR 4 RCC401 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-307-01 RCC FLOOR 3 RCC307 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-304-01 RCC FLOOR 3 RCC304 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-301-01 RCC FLOOR 3 RCC301 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-204-01 RCC FLOOR 2 RCC204 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-201-01 RCC FLOOR 2 RCC201 RECESSED 1 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-108-01 RCC FLOOR 1 RCC108 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-106-01 RCC FLOOR 1 RCC104 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-104-01 RCC FLOOR 1 RCC104 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-RCC-102-01 RCC FLOOR 1 RCC102 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-P3-5101-01 P3 LEVEL 5 P35101 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-P3-2202-01 P3 LEVEL 2 P32202 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-P3-1301-01 P3 LEVEL 1 P31301 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
EWH-P3-1205-01 P3 LEVEL 1 P31205 RECESSED 2 208/1 NA NA NA 16 208/1 41 TRANE UHWA 1
NUMBER LOCATION SERVICE TYPE (kW) PHASE GPM (°F) (°F) WATTS PHASE (LBS) & MODEL KEY NOTES
TAG OUTPUT VOLT/ EWT WTD VOLT/ WEIGHT MANUFACTURER
MIN APPROX.
ELECTRIC HEATING COIL HYDRONIC HEATING COIL MOTOR
WALL HEATER SCHEDULE:
CEM
2. PROVIDE BALLARDS TO PROTECT EQUIPMENT FROM TRAFFIC.
1. UNIT MOUNTED ON HOUSEKEEPING PAD
KEY NOTE(S):
1. MINIMUM EFFICIENCY IS AT ARI STANDARD CONDITIONS.
NOTE(S):
ACU-P3-3105-01 P3 LEVEL 3 RESTROOMS 121 114.0 91.4/67.4 167 25.2 22 460/3 11.0 3.0 1100 AAON CFA 1, 2
ACU-P3-0202-01 P3 LEVEL 1 EAST TUNNEL 75 64 91.4/67.3 80 25.2 17 460/3 11.0 3.0 1100 AAON CFA 1, 2
NUMBER LOCATION SERVICE (MBH) (MBH) (°F DB/WB) (MBH) (°F) FLA PHASE (S)EER COP (LBS) MODEL KEY NOTES
TAG CAPACITY CAPACITY AMBIENT CAPACITY AMBIENT VOLT/ WEIGHT MANUFACTURER &
TOTAL SENSIBLE TOTAL APPROX.
DX COOLING DX HEATING ELECTRICAL MINIMUM EFFICIENCY
OUTDOOR UNIT SCHEDULE:
3. SEE M6.007/2 FOR CONTROL REQUIREMENTS.
2. SEE M6.007/1 FOR CONTROL REQUIREMENTS.
1. UNIT TO BE PROVIDED DX COIL, SEE OUTDOOR UNIT SCHEDULE FOR SELECTION REQUIREMENTS.
KEY NOTE(S):
5. PROVIDE SCCR SUFFICIENT TO MEET THE AVAILABLE FAULT CURRENT AT THE PANELBOARD OR SWITCHBOARD FROM WHICH THE UNIT IS FED. COORDINATE WITH ELECTRICAL DRAWINGS AND ELECTRICAL CONTRACTOR.
4. COOLING COILS BASED ON MAXIMUM FACE VELOCITY OF 450 FPM, 0.70 IN WG MAXIMUM AIR PRESSURE DROP AND 18 FT WG MAXIMUM WATER PRESSURE DROP.
3. HEATING COILS BASED ON MAXIMUM FACE VELOCITY OF 450 FPM, 0.10 IN WG MAXIMUM AIR PRESSURE DROP, 5FT WG MAXIMUM WATER PRESSURE DROP.
2. MINIMUM OSA CALCULATED BASED ON CODE AND ASHRAE STANDARD 62.
1. UNITS MOUNTED ON HOUSEKEEPING PAD AND SPRING BASE.
NOTE(S):
AHU-P1-201-01 LEVEL 2 P1 OGC 3,200 450 450 8 13 1 3,200 PLUG 2.5 2,618 2.5 3.0 480/3 YES 1 3,200 PLUG 1.2 3,384 1.4 2 480/3 YES 40.0 90.0 20.0 91/67 53 / 51 164 128.5 21.0 42 60 6,000 ENERGY LABS 3
AHU-P3-0202-01 EAST TUNNEL EAST TUNNEL 2,900 300 300 8 13 1 2,900 PLUG 2.5 2,618 2.5 3.0 480/3 YES 1 2,900 PLUG 1.3 3,384 1.4 2 480/3 YES 40.0 90.0 20.0 91/67 53 / 51 148.6 116.5 DX DX DX 6,000 ENERGY LABS 1, 2
NUMBER LOCATION SERVICE CFM CFM CFM RATING RATING QUANTITY CFM TYPE (IN. WG.) RPM BHP HP PHASE VFD QUANTITY CFM TYPE (IN. WG.) RPM BHP HP PHASE VFD (°F) (°F) KW DB/WB DB/WB TOTAL SENSIBLE GPM (°F) (°F) (LBS) & MODEL NOTE(S)
TAG OSA OSA OSA MERV MERV FAN ESP FAN MOTOR MOTOR VOLT/ FAN ESP FAN MOTOR MOTOR VOLT/ EAT LAT EAT °F LAT °F EWT LWT WEIGHT MANUFACTURER KEY
MAX MIN MIN FILTER FILTER APPROX.
CODE PRE- FINAL
MBH
MIXING BOX SUPPLY FAN RETURN/EXHAUST FAN ELECTRIC HEATING COIL COOLING COIL
AIR HANDLING UNIT:
4. REFER TO SPECIFICATION SECTION ## 05 00 - COMMON WORK RESULTS FOR DIVISION 21, 22, 23, 26, AND 27 FOR COMPLETE SUBMITTAL REQUIREMENTS.
3. ALL FIRESTOPPING LOCATIONS WILL BE ABLE TO BE INSPECTED BY INSPECTION AGENCY, PRIOR TO CONCEALING.
2. ALL RATED PENETRATIONS SHALL BE PROVIDED TO MEET SPECIFICATION 078400 FIRESTOPPING AND THE REQUIREMENTS OF FM GLOBAL.
1. DEFERRED SUBMITTALS SHALL BE SUBMITTED TO THE CITY 30 DAYS PRIOR TO WORK START.
NOTE(S):
P1/P2 - FIRE STOPPING MECHANICAL PIPING, CONTROLS CONDUIT, DUCTWORK
P1/P2 - SEISMIC BRACING MECHANICALAIR HANDLING EQUIPMENT, CONDENSING UNITS, LARGE PIPE RUNS, LARGE DUCT RUNS, HEATEXCHANGERS
P3 - FIRE STOPPING MECHANICAL PIPING, CONTROLS CONDUIT, DUCTWORK
P3 - SEISMIC BRACING MECHANICALAIR HANDLING EQUIPMENT, CONDENSING UNITS, LARGE PIPE RUNS, LARGE DUCT RUNS, ROOFTOPEQUIPMENT
RCC - FIRE STOPPING MECHANICAL PIPING, CONTROLS CONDUIT, DUCTWORK
RCC - SEISMIC BRACING MECHANICALAIR HANDLING EQUIPMENT, CONDENSING UNITS, PUMPS, LARGE PIPE RUNS, LARGE DUCT RUNS,EXPANSIONTANKS, ROOFTOP EQUIPMENT
SUBMITTAL DISCIPLINE EQUIPMENT
DEFERRED SUBMITTALS
DEFERRED SUBMITTAL TO THE CITY OF PORTLAND REQUIREMENTS:
Z
Z
Z
Z
CEM
PRELI
MIN
ARY, N
OT F
OR
CONSTR
UCTIO
N
01/4
"1/2
"1"
2"
GR
AP
HIC
SC
ALE
-FO
R R
EF
ER
EN
CE
ON
LY
dark
gra
ybla
ck
light
gra
y
CA
N Y
OU
SE
E T
HE
AIR
PLA
NE
S? T
HE
AD
JA
CE
NT
SA
MP
LE
S S
HO
W T
HR
EE
DIF
FE
RE
NT
LE
VE
LS
OF
SH
AD
ING
.
SE
TT
ING
S F
OR
VIE
WIN
G A
ND
PR
INT
ING
DR
AW
ING
CO
NT
EN
T A
RE
OP
TIM
IZE
D W
HE
N A
LL T
HR
EE
PLA
NE
S
AR
E V
ISIB
LE
. T
HIS
GU
IDA
NC
E IS
PR
OV
IDE
D F
OR
RE
FE
RE
NC
E O
NLY
.
PRINTED:
PORTLAND, OREGON
DESIGN NUMBER PROJECT NUMBER
PORT OF PORTLANDPORTLAND, OREGON
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17".
DRAWING NO. SHEET NO. DISC. SHT. NO.TYPE
PROJECT ENGINEER
GRANT EVENHUS
SUBMITTED BY
NO. DATE BY REVISIONS APP'VD CK'D NO. DATE BY REVISIONS APP'VD CK'D
PORTLAND INTERNATIONAL AIRPORT
SCALE
DATE
CHECKED BY
DRAWN BY
DESIGNED BY
707 SW Washington Street | Suite 1200Portland, OR 97205
t 503 221 0150 f 503 295 0840
YOST GRUBE HALLARCHITECTURE
NONE
2/5/2020 4:57:05 PM BIM 360://16-1480 - PACR/PDX-xxxx-102170-P3-04-MEP-Main.rvt
M0.005
PARKING AND CONSOLIDATED RENTAL FACILITY
EQUIPMENT SCHEDULE 3 - MECHANICAL
C. MORGAN
S. WRIGHT
D. NACHTRIEB
JAN 2020
2015D038 PDX 2019-500102171 CD xxxx
1 11/27/2019 AS NEGOATIATED
Z 01/31/2020 ADDENDUM 13
CEM
5. INSTALL MOTOR REMOVAL RAILS.
4. SINGLE POINT ELECTRCAL CONNECTION.
3. SEE M6.008/2 FOR CONTROL REQUIREMENTS.
2. SEE M6.008/1 FOR CONTROL REQUIREMENTS.
1. UNIT TO BE DX, REFER TO OUTDOOR UNIT SCHEDULE FOR COIL CAPACITIES.
KEY NOTE(S):
6. HEAT RECOVERY SECTION EFFECTIVENESS IS BASED ON AHRI 1060.
5. PROVIDE SCCR SUFFICIENT TO MEET THE AVAILABLE FAULT CURRENT AT THE PANELBOARD OR SWITCHBOARD FROM WHICH THE UNIT IS FED. COORDINATE WITH ELECTRICAL DRAWINGS AND ELECTRICAL CONTRACTOR.
4. COOLING COILS BASED ON MAXIMUM FACE VELOCITY OF 450 FPM, 0.60 IN WG MAXIMUM AIR PRESSURE DROP AND 15 FT WG MAXIMUM WATER PRESSURE DROP.
3. HEATING COILS BASED ON MAXIMUM FACE VELOCITY OF 450 FPM, 0.25 IN WG MAXIMUM AIR PRESSURE DROP, 5FT WG MAXIMUM WATER PRESSURE DROP.
2. MINIMUM OSA CALCULATED BASED ON CODE AND ASHRAE STANDARD 62.
1. INDOOR UNITS MOUNTED ON HOUSEKEEPING PAD.
NOTE(S):
HRU-RCC-505-01 24,000 24,000 PLATE NA 22.0 61.0 72.0 63.0% 92/68 78.2/63.7 70/53 63.0% 25.2 75.0 63.0 140 110 - - - - 78.2/63.7 54 / 53 96.0 44 62 37,500 ENERGY LABS 2, 5
HRU-P3-3105-01 4,000 4,000 WHEEL 480 25.2 56.0 72.0 66.0% 91/63 78.5/65 72/60 66.0% 56 87.5 - - - 167 22/21 70/58 48.8/43.9 78.5/65 53.6/53.2 - - - 2,500 AAON V3 1, 3, 4, 5
NUMBER CFM CFM TYPE PHASE (°F DB) (°F DB) (°F DB) EFFECTIVENESS (°F DB/WB) (°F DB/WB) (°F DB/WB) EFFECTIVENESS (°F) (°F) GPM (°F) (°F) (MBH) (°F DB/WB) (°F DB/WB) (°F DB/WB) (°F DB/WB) (°F DB/WB) GPM (°F) (°F) (LBS) MODEL KEY NOTES
TAG OSA EXHAUST VOLT/ EAT LAT EAT OSA EAT OSA LAT EXH EAT EAT LAT EWT LWT TOTAL CAPACITY OSA RA EAT EAT LAT EWT LWT WEIGHT MANUFACTURER &
OSA OSA EXH APPROX.
WINTER SUMMER
HEAT RECOVERY SECTION HEATING COIL AUXILIARY HEAT COOLING COIL
HEAT RECOVERY UNIT (CONTINUED):
HRU-RCC-505-01 PENTHOUSE VENTILATION 24,000 10,000 10,000 8 13 2 12,000 PLUG 20 6.5 480/3 YES 2 12,000 PLUG 15 4 480/3 YES
HRU-P3-3105-01 P3 LEVEL 3 P3 RESTROOMS 4,000 - 4,000 8 13 1 4,000 PLUG 8 3.5 480/3 NO/EC 1 4,000 PLUG 4 2.1 480/3 NO/EC
NUMBER LOCATION SERVICE CFM CFM CFM RATING RATING QUANTITY CFM TYPE HP (IN. WG.) PHASE VFD QUANTITY CFM TYPE HP (IN. WG.) PHASE VFD
TAG OSA OSA OSA MERV MERV AIRFLOW FAN MOTOR ESP VOLT/ AIRFLOW FAN MOTOR ESP VOLT/
MAX MIN MIN FILTER FILTER
CODE PRE- FINAL
MIXING BOX SUPPLY FAN RETURN/EXHAUST FAN
HEAT RECOVERY UNIT:
6. SEE M6.010/1 FOR CONTROL REQUIREMENTS.
5. PROVIDE SCCR SUFFICIENT TO MEET THE AVAILABLE FAULT CURRENT AT THE PANELBOARD OR SWITCHBOARD FROM WHICH THE UNIT IS FED. COORDINATE WITH ELECTRICAL DRAWINGS AND ELECTRICAL CONTRACTOR.
4. COOLING COILS BASED ON MAXIMUM FACE VELOCITY OF 450 FPM, 0.5 IN WG MAXIMUM AIR PRESSURE DROP AND 18 FT WG MAXIMUM WATER PRESSURE DROP.
3. HEATING COILS BASED ON MAXIMUM FACE VELOCITY OF 450 FPM, 0.15 IN WG MAXIMUM AIR PRESSURE DROP, 5FT WG MAXIMUM WATER PRESSURE DROP.
2. MINIMUM OSA CALCULATED BASED ON CODE AND ASHRAE STANDARD 62.
1. UNITS HUNG FROM SPRING ISOLATORS
NOTE(S):
FC-RCC-1502-01 MAIN ELEC RCC1502 TENANT 400 120 120 13 0.4 0.3 0.5 208/1 7500 68.0 85.0 1.5 110 100 5800 75 60 62 21 0.6 42 60 75 JOHNSON CONTROLS
FC-RCC-405-01 IDF RCC405 TENANT 400 120 120 13 0.4 0.3 0.5 208/1 7500 68.0 85.0 1.5 110 100 5800 75 60 62 21 0.6 42 60 75 JOHNSON CONTROLS
FC-RCC-305-01 IDF RCC305 TENANT 400 120 120 13 0.4 0.3 0.5 208/1 7500 68.0 85.0 1.5 110 100 5800 75 60 62 21 0.6 42 60 75 JOHNSON CONTROLS
FC-RCC-205-01 IDF RCC205 TENANT 400 120 120 13 0.4 0.3 0.5 208/1 7500 68.0 85.0 1.5 110 100 5800 75 60 62 21 0.6 42 60 75 JOHNSON CONTROLS
FC-RCC-139-02 OFFICE RCC133 TENANT 800 240 240 13 0.4 0.4 0.5 208/1 11400 68.0 85.0 2.7 110 100 8700 75 60 62 21 1.0 42 60 92 JOHNSON CONTROLS
FC-RCC-139-01 WORK RCC139 TENANT 450 120 120 13 0.4 0.3 0.5 208/1 7500 68.0 85.0 1.8 110 100 5800 75 60 62 21 0.6 42 60 75 JOHNSON CONTROLS
FC-RCC-134-01 IT RCC134 TENANT 400 120 120 13 0.4 0.3 0.5 208/1 7500 68.0 85.0 1.5 110 100 5800 75 60 62 21 0.6 42 60 75 JOHNSON CONTROLS
FC-RCC-132-01 CONFERENCE RCC122 TENANT 825 240 240 13 0.4 0.4 0.5 208/1 15000 68.0 85.0 3.6 110 100 11500 75 60 62 21 1.3 42 60 141 JOHNSON CONTROLS
FC-RCC-131-01 BREAK RCC131 TENANT 825 250 250 13 0.4 0.3 0.5 208/1 15500 68.0 85.0 3.7 110 100 11800 75 60 62 21 1.3 42 60 141 JOHNSON CONTROLS
FC-RCC-127-01 IT RCC127 TENANT 400 120 120 13 0.4 0.3 0.5 208/1 7500 68.0 85.0 1.5 110 100 5800 75 60 62 21 0.6 42 60 75 JOHNSON CONTROLS
FC-RCC-124-02 OFFICE RCC126 TENANT 1,040 330 330 13 0.4 0.4 0.5 208/1 19500 68.0 85.0 4.7 110 100 14900 75 60 62 21 1.7 42 60 158 JOHNSON CONTROLS
FC-RCC-124-01 WORK RCC124 TENANT 600 185 185 13 0.4 0.6 0.8 208/1 11400 68.0 85.0 2.7 110 100 8700 75 60 62 21 1.0 42 60 92 JOHNSON CONTROLS
FC-RCC-123-01 BREAK RCC123 TENANT 800 240 240 13 0.4 0.4 0.5 208/1 15000 68.0 85.0 3.6 110 100 11500 75 60 62 21 1.3 42 60 141 JOHNSON CONTROLS
FC-RCC-120-01 OPEN OFFICE RCC120 TENANT 850 255 255 13 0.4 0.3 0.5 208/1 15900 68.0 85.0 1.5 110 100 12200 75 60 62 21 1.4 42 60 141 JOHNSON CONTROLS
FC-RCC-116-01 IT RCC116 TENANT 400 120 120 13 0.4 0.3 0.5 208/1 7500 68.0 85.0 1.5 110 100 5800 75 60 62 21 0.6 42 60 75 JOHNSON CONTROLS
FC-RCC-113-01 WORK RCC113 TENANT 400 120 120 13 0.4 0.3 0.5 208/1 7500 68.0 85.0 1.5 110 100 5800 75 60 62 21 0.6 42 60 75 JOHNSON CONTROLS
FC-RCC-110-01 WORK RCC110 TENANT 400 120 120 13 0.4 0.3 0.5 208/1 7500 68.0 85.0 1.5 110 100 5800 75 60 62 21 0.6 42 60 75 JOHNSON CONTROLS
FC-RCC-105-01 IDF RCC105 TENANT 400 120 120 13 0.4 0.3 0.5 120/1 7500 68.0 85.0 1.5 110 100 5800 75 60 62 21 0.6 42 60 75 JOHNSON CONTROLS
NUMBER LOCATION SERVICE CFM CFM CFM RATING (IN. WG.) BHP HP PHASE BTUH (°F) (°F) GPM (°F) (°F) BTUH DB WB DB WB GPM (°F) (°F) (LBS) MODEL
TAG AIRFLOW OSA OSA MERV ESP MOTOR MOTOR VOLT/ DESIGN EAT LAT EWT LWT DESIGN EWT LWT WEIGHT MANUFACTURER &
MIN MIN FILTER MIN MIN APPROX.
CODE FINAL
EAT °F LAT °F
HYDRONIC HEATING COIL - RADIANT LOOP HYDRONIC COOLING COIL
FAN COIL UNIT:
Z
Z
CEM
PRELI
MIN
ARY, N
OT F
OR
CONSTR
UCTIO
N
19202122
3" RX 1
3" RX 1
2 3 4
2 3 4
5
K.5
J.5
H.5
18 17 16
6" RX UP
TYP.2
M5.005
6" CHWS UP
6 (TYP 9)
SEE 1 / M1.002FOR CONTINUATION
6" CHWR UP
6 (TYP 10)
7
7
7
6 (TYP 8)
6 (TYP 9)
6" CHWR
6" CHWS
1 1/4" RHW UPTO MANIFOLD
1 1/4" RHW UPTO MANIFOLD
1 1/4" RHW UPTO MANIFOLD
1 1/4" RHW UPTO MANIFOLD
1 1/4" RHW UPTO MANIFOLD
1 1/4" RHW UPTO MANIFOLD
Z
1 1/4" RHW UP
1 1/4" RHW UP
15
01/4
"1/2
"1"
2"
GR
AP
HIC
SC
ALE
-FO
R R
EF
ER
EN
CE
ON
LY
dark
gra
ybla
ck
light
gra
y
CA
N Y
OU
SE
E T
HE
AIR
PLA
NE
S? T
HE
AD
JA
CE
NT
SA
MP
LE
S S
HO
W T
HR
EE
DIF
FE
RE
NT
LE
VE
LS
OF
SH
AD
ING
.
SE
TT
ING
S F
OR
VIE
WIN
G A
ND
PR
INT
ING
DR
AW
ING
CO
NT
EN
T A
RE
OP
TIM
IZE
D W
HE
N A
LL T
HR
EE
PLA
NE
S
AR
E V
ISIB
LE
. T
HIS
GU
IDA
NC
E IS
PR
OV
IDE
D F
OR
RE
FE
RE
NC
E O
NLY
.
PRINTED:
PORTLAND, OREGON
DESIGN NUMBER PROJECT NUMBER
PORT OF PORTLANDPORTLAND, OREGON
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17".
DRAWING NO. SHEET NO. DISC. SHT. NO.TYPE
PROJECT ENGINEER
GRANT EVENHUS
SUBMITTED BY
NO. DATE BY REVISIONS APP'VD CK'D NO. DATE BY REVISIONS APP'VD CK'D
PORTLAND INTERNATIONAL AIRPORT
SCALE
DATE
CHECKED BY
DRAWN BY
DESIGNED BY
707 SW Washington Street | Suite 1200Portland, OR 97205
t 503 221 0150 f 503 295 0840
YOST GRUBE HALLARCHITECTURE
2/5/2020 4:57:26 PM BIM 360://16-1480 - PACR/PDX-xxxx-102170-P3-04-MEP-Main.rvt
3/32" = 1'-0" M2.000
PARKING AND CONSOLIDATED RENTAL FACILITY
RCC – UNDERGROUND – FLOOR PLAN - MECHANICAL
C. MORGAN
S. WRIGHT
D. NACHTRIEB
JAN 2020
2015D038 PDX 2019-500102171 CD xxxx
.5
A
14
L
N
1A 1B
2B2C 2D 2E
1C 1D 1E
KEY PLANSCALE: N.T.S.
1 11/27/2019 AS NEGOATIATED
Z 01/31/2020 ADDENDUM 13
32'21'-4"10'-8"5'-4"0'
SCALE: IN FEET
N
KEY NOTE(S) :#
1. 3-INCH PERFORATED PVC PIPING FOR RADON GAS CONVEYANCE SYSTEM. BED PIPE IN 12"x8" GRAVEL TRENCH AND RUN TIGHT TO UNDERSIDE OF SLAB.
2. GAS CONVEYANCE PIPING ZONES LIMITED TO A MAXIUM OF 15,000 SF.
3. HORIZONTAL RUNS OF RADON SYSTEM PIPING WITHIN THE BUILDING SHALL NOT BE TRAPPED AND SHALL HAVE A MINIMUM 1% SLOPE BACK TO THE VERTICAL RISER.
4. GAS CONVEYANCE PIPING MUST BE ROUTED INTO ALL SUBSLAB AREAS ISOLATED BY SUBSLAB WALL FOOTINGS AND NO FARTHER THAN 50 FT FROM AN EXTERIOR WALL FOOTING OR INTERIOR WALL CUT-OFF FOOTING.
5. PROVIDE PIPING SLEEVES FOR PIPING THROUGH STRUCTURAL FITTING. COORDINATE EXACT LOCATION OF SLEVES IN FIELD.
6. PROVIDE INDIVIDUAL 1/2" RADIANT WATER SUPPLY AND RETURN LINES FOR IN-FLOOR CONVECTOR UNIT BACK TO ZONE MANIFOLD.
7. 1-1/4" SUPPLY AND RETURN PRE-INSULATED DIRECT BURY DUAL PIPING.
CEM
Z
CEM
PRELI
MIN
ARY, N
OT F
OR
CONSTR
UCTIO
N
D
DDD
OFFICESERVICE LOBBYRCC108
OFFICEVESTIBULERCC109
ELEV 01RCC-EL01
ELEV 02RCC-EL02
RENTAL CARCIRCULATIONZONERCC100
STAIR 01RCC-ST01
RAC COUNTERZONERCC141
OPEN OFFICERCC120
WORK AREARCC129
WORK AREARCC124
STORAGEROOMRCC128
BREAKROOMRCC130
DM OFFICERCC119
WORK AREARCC110
WORK AREARCC113
OFFICERCC111
OFFICERCC114
MANAGEROFFICERCC118
IT CLOSETRCC116
BREAKROOMRCC123
OFFICERCC126
WORK AREARCC124 IT CLOSET
RCC127
WORK AREARCC124
STORAGEROOMRCC128
19202122
EWH-RCC-ST01-01
EWH-RCC-108-01
250C-2
1
200C-1
200C-1
275C-1
(TYP 2)
FC-RCC-120-01
FC-RCC-123-01
100C-1
100C-1
300C-1
100C-1
FC-RCC-113-01
24x10
400C-1
(TYP 2)150C-1
375C-1
(TYP 2)
FC-RCC-124-01
FC-RCC-116-01
6" DIA.
6" DIA.
28x14
10" DIA.
---
C-2
100C-2
24x10
10" DIA.
8" DIA.
TU-RCC-108-01
TU-RCC-108-02
40010x10 H-1
(OSA TO RCC100)
20x12 TRANSFER DUCT
10" DIA.
8" DIA.
6" DIA.
14" ROUND DUCT UP THROUGH FALSE COLUMN
2
8x8 RETURNBOOT
8x8 RETURNBOOT
8x8 RETURNBOOT
---
C-2
---
C-2
---
C-2
8x8 RETURNBOOT
---
C-2
12x12 RETURNBOOT
K.5
J.5
H.5
18
20x20
20x20 UP
28x10
58x10
12" DIA.
12" DIA.
40x14 TRANSFER DUCT
16x1616x16
10” DIA. SA UP
10” DIA. EXH UP
18x18 TRANSFER DUCT
8" DIA.
40x12 TRANSFER DUCT
200C-2
---
C-2
100C-1
20x12 TRANSFER DUCT
---
C-2
VVR-RCC-110-01
30x10---
C-2
12x10
10" DIA.
10" DIA.
8" DIA.
30x108" DIA.
8" DIA.8" DIA.
8" DIA.
6" DIA.
8" DIA.
8" DIA.
6" DIA.
18x8
4
M4.019_________
14x14
3
3/4" D
3/4" D
3
3/4" D
3/4" D
3
3/4" D
2
2
2
2
150C-1
200C-1
(TYP 2)
50C-1
FC-RCC-110-01
3/4" D
01/4
"1/2
"1"
2"
GR
AP
HIC
SC
ALE
-FO
R R
EF
ER
EN
CE
ON
LY
dark
gra
ybla
ck
light
gra
y
CA
N Y
OU
SE
E T
HE
AIR
PLA
NE
S? T
HE
AD
JA
CE
NT
SA
MP
LE
S S
HO
W T
HR
EE
DIF
FE
RE
NT
LE
VE
LS
OF
SH
AD
ING
.
SE
TT
ING
S F
OR
VIE
WIN
G A
ND
PR
INT
ING
DR
AW
ING
CO
NT
EN
T A
RE
OP
TIM
IZE
D W
HE
N A
LL T
HR
EE
PLA
NE
S
AR
E V
ISIB
LE
. T
HIS
GU
IDA
NC
E IS
PR
OV
IDE
D F
OR
RE
FE
RE
NC
E O
NLY
.
PRINTED:
PORTLAND, OREGON
DESIGN NUMBER PROJECT NUMBER
PORT OF PORTLANDPORTLAND, OREGON
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17".
DRAWING NO. SHEET NO. DISC. SHT. NO.TYPE
PROJECT ENGINEER
GRANT EVENHUS
SUBMITTED BY
NO. DATE BY REVISIONS APP'VD CK'D NO. DATE BY REVISIONS APP'VD CK'D
PORTLAND INTERNATIONAL AIRPORT
SCALE
DATE
CHECKED BY
DRAWN BY
DESIGNED BY
707 SW Washington Street | Suite 1200Portland, OR 97205
t 503 221 0150 f 503 295 0840
YOST GRUBE HALLARCHITECTURE
2/5/2020 4:58:11 PM BIM 360://16-1480 - PACR/PDX-xxxx-102170-P3-04-MEP-Main.rvt
1/8" = 1'-0" M2.105
PARKING AND CONSOLIDATED RENTAL FACILITY
RCC - LEVEL 1 - SECTOR 1A - FLOOR PLAN -MECHANICAL
C. MORGAN
S. WRIGHT
D. NACHTRIEB
JAN 2020
2015D038 PDX 2019-500102171 CD xxxx
1 11/27/2019 AS NEGOATIATED
Z 01/31/2020 ADDENDUM 13
N
24'16'8'4'0'
SCALE: IN FEET
.5
A
14
L
N
1A 1B
2B2C 2D 2E
1C 1D 1E
KEY PLANSCALE: N.T.S.
CEM
KEY NOTE(S) :#
1. POWER TRANSFORMER TO SERVE FIN TUBE PROVIDED BY MANUFACTURER. POWERED BY DIV. 26 WITH DISTRIBUTION TO FIN TUBE BY DIV. 23
2. AIR TRANSFER DUCTS FROM PLENUM SPACE INTO RENTAL CAR CIRCULATION ZONE. (TYPICAL)
3. PROVIDE CONDENSATE DRAIN CONNECTION AT SINK TAILPIECE.
MA
TC
HL
INE
SE
E S
HE
ET
M2.1
06
Z
CEM
PRELI
MIN
ARY, N
OT F
OR
CONSTR
UCTIO
N
B
TOILET ROOMRCC102
FIRE PUMPROOMRCC106
RENTAL CARVESTIBULERCC101
JANP31103
STAIR 01
PORT IDFRCC105
RESTROOMENTRYRCC103
RENTAL CARCIRCULATIONZONERCC100
DEMARKP31104A
RAC TOILETSP31101
ELECVESTIBULERCC104
RAC TOILETSP31102
STAIR 02RCC-ST02
RAC COUNTERZONERCC141
RAC MPOEP31104B
CONFERENCE /TRAININGROOMRCC122
OPEN OFFICERCC125
STORAGERCC132
WORK AREARCC139
OFFICERCC135
OFFICERCC133
OFFICERCC137
OFFICERCC138
STORAGEROOMRCC140
STORAGEROOMRCC128
BREAKROOMRCC131
STORAGERCC136
IT ROOMRCC134
IT CLOSETRCC127
STORAGEROOMRCC128
STAIR 03RCC-ST03
EWH-RCC-ST02-01
EWH-RCC-102-01
10x10
758x8 H-2
12x10
300C-2
(TYP 2)
300C-2
(TYP 2)
12x12
600C-1
(TYP 2)
70C-2
EWH-RCC-106-01
EWH-RCC-104-01
506x6 H-1
16x16
10x10
10x10
14x10
12x12
10x10
1
2
6" DIA.
200C-1
(TYP 4)
415C-1
140C-1
FC-RCC-131-01
400C-1FC-RCC-139-01
FC-RCC-139-02FC-RCC-132-01
410C-1
FC-RCC-134-01
FC-RCC-105-01
FC-RCC-124-02
---
C-2
---
C-2(TYP 4)
---
C-2
50x10
30x8
3
50C-1
50C-1
50C-1
50C-1
20x20
4
20x12
K.5
J.5
H.5
18 17 16
6" RX DN
6" DIA. UP
18x18 TRANSFER DUCT
FC-RCC-127-01
TF-RCC-106-01
36" x 24" LOUVER, 50% FREE AREA MINIMUM
36x18TRANSFERDUCT
10" DIA.
8" DIA.
375C-1
8" DIA.
8" DIA.
12" DIA.
12" DIA.
6" DIA.
6" DIA.
8" DIA.
52x10
50x10
6" DIA.
12" DIA. , TYP 2
400C-1
(TYP 2)
63/4" D
6
3/4" D
1" D
3/4" D
3/4" D
3/4" D
8" DIA. , TYP 4
8" DIA.
12" DIA.
3/4" D
15
3
M4.019_________
01/4
"1/2
"1"
2"
GR
AP
HIC
SC
ALE
-FO
R R
EF
ER
EN
CE
ON
LY
dark
gra
ybla
ck
light
gra
y
CA
N Y
OU
SE
E T
HE
AIR
PLA
NE
S? T
HE
AD
JA
CE
NT
SA
MP
LE
S S
HO
W T
HR
EE
DIF
FE
RE
NT
LE
VE
LS
OF
SH
AD
ING
.
SE
TT
ING
S F
OR
VIE
WIN
G A
ND
PR
INT
ING
DR
AW
ING
CO
NT
EN
T A
RE
OP
TIM
IZE
D W
HE
N A
LL T
HR
EE
PLA
NE
S
AR
E V
ISIB
LE
. T
HIS
GU
IDA
NC
E IS
PR
OV
IDE
D F
OR
RE
FE
RE
NC
E O
NLY
.
PRINTED:
PORTLAND, OREGON
DESIGN NUMBER PROJECT NUMBER
PORT OF PORTLANDPORTLAND, OREGON
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17".
DRAWING NO. SHEET NO. DISC. SHT. NO.TYPE
PROJECT ENGINEER
GRANT EVENHUS
SUBMITTED BY
NO. DATE BY REVISIONS APP'VD CK'D NO. DATE BY REVISIONS APP'VD CK'D
PORTLAND INTERNATIONAL AIRPORT
SCALE
DATE
CHECKED BY
DRAWN BY
DESIGNED BY
707 SW Washington Street | Suite 1200Portland, OR 97205
t 503 221 0150 f 503 295 0840
YOST GRUBE HALLARCHITECTURE
2/5/2020 4:58:20 PM BIM 360://16-1480 - PACR/PDX-xxxx-102170-P3-04-MEP-Main.rvt
1/8" = 1'-0" M2.106
PARKING AND CONSOLIDATED RENTAL FACILITY
RCC - LEVEL 1 - SECTOR 1B - FLOOR PLAN -MECHANICAL
C. MORGAN
S. WRIGHT
D. NACHTRIEB
JAN 2020
2015D038 PDX 2019-500102171 CD xxxx
1 11/27/2019 AS NEGOATIATED
Z 01/31/2020 ADDENDUM 13
N
.5
A
14
L
N
1A 1B
2B2C 2D 2E
1C 1D 1E
KEY PLANSCALE: N.T.S.
24'16'8'4'0'
SCALE: IN FEET
CEM
KEY NOTE(S) :#
1. PROVIDE RATED SHAFT DROP BELOW STRUCTURE AT BOTTOM OF SUPPLY AND DUCT RISERS. REFER TO ARCHITECTURAL PLANS FOR SHAFT REQUIREMENTS.
2. POWER TRANSFORMER TO SERVE FIN TUBE PROVIDED BY MANUFACTURER. POWERED BY DIV. 26 WITH DISTRIBUTION TO FIN TUBE BY DIV. 23
3. 44x22 TRANSFER DUCT
4. 8x8 RETURN BOOT (TYP 4)
5. INTERLOCK EXHAUST FAN WITH ROOM THERMOSTAT. EXHAUST FAN TO RUN WHEN ROOM TEMPERATURE GREATER THAN 90F.
6. PROVIDE CONDENSATE DRAIN CONNECTION AT SINK TAILPIECE.
MA
TC
HL
INE
SE
E S
HE
ET
M2.1
05
Z
Z
Z
CEM
PRELI
MIN
ARY, N
OT F
OR
CONSTR
UCTIO
N
STAIR 01RCC-ST01
EQ
EQ
19202122
2
M4.019_________
K.5
J.5
H.5
18
14" DIA.
14" DIA.
14" DIA.205
10x10 H-1(TYP 2)
8" DIA. TYPICAL
FC-RCC-109-01
250S-2
10" DIA.
16" DIA.
36x36
10" DIA.
16" DIA.
30x20 SA UP
36X36RA UPIN SLAB FSDIN RISER
IN SLAB FSDIN RISER
2
20x20 DUCT DN TO SERVE TERMINAL UNITS ABOVE RCC108
14" ROUND DUCT DN THROUGH FALSE COLUMN TO BACK OF HOUSE
2 1/2" RHWS/R, 3" CHWS/R, 2 1/2" RWS/R TO MANIFOLDS, AND 1 1/4" RWS/R DN IN FALSE COLUMN
3" CHWS3" CHWR
2 1/2" RHWR2 1/2" RHWS 40x12
TRANSFERDUCT
2 1/2" RHWS2 1/2" RHWR
3" CHWR3" CHWS
6" DIA.
3” RCHWS/R UP
6” CHWS/R UP10” DIA. EXH DN
10” DIA. SA DN
18x18 TRANSFER DUCT
40x14 TRANSFER DUCT
20510x10 H-1
(TYP 2)
20x12TRANSFERDUCT
20x12TRANSFERDUCT
3/4” RHWS/R AND 3/4”CHWS/R DN TO FC
3/4” RHWS/R AND 3/4”CHWS/R DN TO FC
3/4” RHWS/R AND 1" CHWS/R DN TO FC
3/4” RHWS/R AND 1" CHWS/R DN TO FC
1” RHWS/R AND 1" CHWS/R DN TO FC
1” RHWS/R AND 1" CHWS/R DN TO FC
2000C-2
(TYP 2)
12" DIA.
12" DIA.
---
C-2
12x12
ELEV 01RCC-EL01
34x12
4
M4.019_________
Z
6" CHWS/R DN
6" CHWS/R UP
01/4
"1/2
"1"
2"
GR
AP
HIC
SC
ALE
-FO
R R
EF
ER
EN
CE
ON
LY
dark
gra
ybla
ck
light
gra
y
CA
N Y
OU
SE
E T
HE
AIR
PLA
NE
S? T
HE
AD
JA
CE
NT
SA
MP
LE
S S
HO
W T
HR
EE
DIF
FE
RE
NT
LE
VE
LS
OF
SH
AD
ING
.
SE
TT
ING
S F
OR
VIE
WIN
G A
ND
PR
INT
ING
DR
AW
ING
CO
NT
EN
T A
RE
OP
TIM
IZE
D W
HE
N A
LL T
HR
EE
PLA
NE
S
AR
E V
ISIB
LE
. T
HIS
GU
IDA
NC
E IS
PR
OV
IDE
D F
OR
RE
FE
RE
NC
E O
NLY
.
PRINTED:
PORTLAND, OREGON
DESIGN NUMBER PROJECT NUMBER
PORT OF PORTLANDPORTLAND, OREGON
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17".
DRAWING NO. SHEET NO. DISC. SHT. NO.TYPE
PROJECT ENGINEER
GRANT EVENHUS
SUBMITTED BY
NO. DATE BY REVISIONS APP'VD CK'D NO. DATE BY REVISIONS APP'VD CK'D
PORTLAND INTERNATIONAL AIRPORT
SCALE
DATE
CHECKED BY
DRAWN BY
DESIGNED BY
707 SW Washington Street | Suite 1200Portland, OR 97205
t 503 221 0150 f 503 295 0840
YOST GRUBE HALLARCHITECTURE
2/5/2020 4:58:24 PM BIM 360://16-1480 - PACR/PDX-xxxx-102170-P3-04-MEP-Main.rvt
1/8" = 1'-0" M2.201
PARKING AND CONSOLIDATED RENTAL FACILITY
RCC - FLOOR 1.5 - SECTOR 1A - MECHANICAL
C. MORGAN
S. WRIGHT
D. NACHTRIEB
JAN 2020
2015D038 PDX 2019-500102171 CD xxxx
.5
A
14
L
N
1A 1B
2B2C 2D 2E
1C 1D 1E
KEY PLANSCALE: N.T.S.
1 11/27/2019 AS NEGOATIATED
Z 01/31/2020 ADDENDUM 13
24'16'8'4'0'
SCALE: IN FEET
MA
TC
HL
INE
SE
E S
HE
ET
M2.2
02
CEM
N
CEM
PRELI
MIN
ARY, N
OT F
OR
CONSTR
UCTIO
N
EMER ELECRCC1503
JANP32103
STAIR 02RCC-ST02
MAIN ELECROOMRCC1502
RAC TOILETSP32102
RAC TOILETSP32101
EQ
EQ
26x16 EXHAUSTDN
26x16 SUPPLYDN
TF-RCC-1503-01
2508x8 H-2
12x12
758x8 H-2
506x6 H-1
6x6
12x12
300C-2
(TYP 2)
10x10
10x10
12x12
10x10
10x10
300C-2
(TYP 2)
600C-1
(TYP 2)
12x10
14x10
6x6
1 1/4" CHWR1 1/4" CHWS
8x8
6" DIA.
FC-RCC-1502-01
1-1/2" D DN
1-1/2" D UP
3/4" D
K.5
J.5
H.5
18 17 16
6x6 EXH DN
6" RX UP
6" RX
6" DIA.
6" RX DN
3/4” RHWS/R AND 1”CHWS/R DN TO FC
1-1/4" CHWS/R UP
8" DIA.
8" DIA.
12" DIA.
12" DIA.
6" DIA. UP
20510x10 H-1
(TYP 4)
3" CHWS3" CHWR
2 1/2" RHWR2 1/2" RHWS
18x18 TRANSFER DUCT44x22 TRANSFER DUCT
18x18 TRANSFER DUCT
8" DIA.
8" DIA.
8" DIA.
8" DIA.
3/4" RHWS/R AND 1" CHWS/R DN TO FC
3/4" RHWS/R AND 3/4" CHWS/R DN TO FC
1” RHWS/R AND 1”CHWS/R DN TO FC
FSD FSD
FD
FD
Z
Z
1" CHWS
1" CHWR
1" CHWS/R DN TO FC
1" CHWR1" CHWS
15
3
M4.019_________
01/4
"1/2
"1"
2"
GR
AP
HIC
SC
ALE
-FO
R R
EF
ER
EN
CE
ON
LY
dark
gra
ybla
ck
light
gra
y
CA
N Y
OU
SE
E T
HE
AIR
PLA
NE
S? T
HE
AD
JA
CE
NT
SA
MP
LE
S S
HO
W T
HR
EE
DIF
FE
RE
NT
LE
VE
LS
OF
SH
AD
ING
.
SE
TT
ING
S F
OR
VIE
WIN
G A
ND
PR
INT
ING
DR
AW
ING
CO
NT
EN
T A
RE
OP
TIM
IZE
D W
HE
N A
LL T
HR
EE
PLA
NE
S
AR
E V
ISIB
LE
. T
HIS
GU
IDA
NC
E IS
PR
OV
IDE
D F
OR
RE
FE
RE
NC
E O
NLY
.
PRINTED:
PORTLAND, OREGON
DESIGN NUMBER PROJECT NUMBER
PORT OF PORTLANDPORTLAND, OREGON
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17".
DRAWING NO. SHEET NO. DISC. SHT. NO.TYPE
PROJECT ENGINEER
GRANT EVENHUS
SUBMITTED BY
NO. DATE BY REVISIONS APP'VD CK'D NO. DATE BY REVISIONS APP'VD CK'D
PORTLAND INTERNATIONAL AIRPORT
SCALE
DATE
CHECKED BY
DRAWN BY
DESIGNED BY
707 SW Washington Street | Suite 1200Portland, OR 97205
t 503 221 0150 f 503 295 0840
YOST GRUBE HALLARCHITECTURE
2/5/2020 4:58:29 PM BIM 360://16-1480 - PACR/PDX-xxxx-102170-P3-04-MEP-Main.rvt
1/8" = 1'-0" M2.202
PARKING AND CONSOLIDATED RENTAL FACILITY
RCC - FLOOR 1.5 - SECTOR 1B - MECHANICAL
C. MORGAN
S. WRIGHT
D. NACHTRIEB
JAN 2020
2015D038 PDX 2019-500102171 CD xxxx
1 11/27/2019 AS NEGOATIATED
Z 01/31/2020 ADDENDUM 13
24'16'8'4'0'
SCALE: IN FEET
N
.5
A
14
L
N
1A 1B
2B2C 2D 2E
1C 1D 1E
KEY PLANSCALE: N.T.S.
CEM
MA
TC
HL
INE
SE
E S
HE
ET
M2.2
01
CEM
PRELI
MIN
ARY, N
OT F
OR
CONSTR
UCTIO
N