Data CenterSolutions Guide
2 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
The data center has become a critical asset of todays information-intensive enterprise, supporting all the applications needed to maintain daily communication, productivity, and functionality. Designing and sustaining a data center capable of supporting these applications is a considerable undertaking, and a properly designed infrastructure is key to maximizing that investment both now and in the future.
Design IssuesDesigning and implementing an infrastructure that maximizes data center management is vital to maintaining availability, operational efficiency, and aesthetics while also supporting growth, advances in technology, regulatory changes, and the increasing need for security. On the other hand, poor infrastructure design decisions can affect long-term reliability and total cost of ownership.
Making some simple choices when designing the infrastructure can result in dramatic improvements for key data center issues such as: Air Flow, Response Time, Administration, Space Utilization, Security and Aesthetics.
Increase in Power ConsumptionThe increase in power density for active data center equipment has driven the cost of cooling and power consump-tion to a new level. Even with the im-proved efficiency and discipline of switch-ing off idle equipment, and using more energy-efficient servers and switches, heat loads in a 42U cabinet have increased 12 times over the past six years. And the best-case scenario has that number rising another 44% over the next six years. In fact, some experts estimate a requirement of 30 to 50 kilowatts for each cabinet or rack space!1 With higher-density cable bundles, an infrastructure design that helps manage airflow into and out of a cabinet is increasingly critical to equipment performance and lifespan, and ultimately data service levels.
Cost of DowntimeDowntime is costly and unacceptable in todays data center. Recent studies show that estimated losses for downtime can run into the millions of dollars for many industries. With more than 50% of all data center infrastructure failures resulting from maintenance or other administration activities2, the data center infrastructure must enable IT managers to deploy equipment, complete reconfigurations, and respond to maintenance issues as quickly as possible.
Infrastructure Design in the
Floor Space CostThe rising cost of environmentally controlled data center real estate, combined with the expense to cool the active equipment, means that space utilization must be carefully considered and efficiently managed. Not only is it important to maximize data center floor space utilization, but also the infrastructure must optimize rack space, minimize connections, and increase cabling density.
SecurityThe protection of data and equipment in todays information-intensive enterprise has called for an increase in both logical and physical security. Not only do IT managers need to ensure that proper encryption and firewalls are in place, but the physical infrastructure must also protect and secure connections and equipment. Infrastructure products including sturdy, tamper-resistant enclosures and fault-resistant connections can go a long way in securing these critical assets.
AestheticsWhile data center availability is paramount, the data center must also showcase a companys commitment to technology. When designing the infrastructure, innovative cabling management solutions can greatly improve the overall look and aesthetics of the data center, both at deployment and following future moves, adds, and changes. Aesthetics is also a benefit from a design that minimizes cable congestion.
The Hubbell CommittmentAs a global manufacturer of structured cabling systems, enclosures, and accessories, Hubbell Premise Wiring can help IT managers respond to the key data center issues of airflow, response time, administration, space utilization, security, and aesthetics. Hubbell is dedicated to delivering product innovation, advanced technology, the highest quality, and customer service excellence for the data center. To top it off, the Hubbell MISSION CRITICAL program gives IT managers the assurance of system success with a 25-year guarantee on the components, performance, and installation integrity of your data centers structured cabling infrastructure.
Call 1-800-626-0005www.hubbell-premise.com 3
1. Brill, K. (2005) 2005-2010 Heat Density Trends in Data Processing, Computer Systems and Telecommunications Equipment (Uptime Institute).2. Site Uptime Procedures and Guidelines for Safely Performing Work in an Active Data Center, CompuSite Engineering, Inc. and the Uptime Institute (2007).
Data Center
4 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
Airflow
Impact Lower operating costs, longer equipment life expectancy.
Design Objectives
Define air pathways. Eliminate airflow obstructions. Reduce cable bulk. Condense connection form factor.
The increasing array of active equipment designed into smaller packages results in more heat and more cable congestion, which impedes airflow.
Administration
Impact Lower operating costs.
Design Objectives
Utilize a structured identification system. Minimize infrastructure components. Defined cable pathways and accessibility.
The ability to locate equipment, cables, and connections at all times is critical in the dynamic data center environment.
Response Time
Impact Maximize uptime.
DesignObjectives
Minimize number of system component parts. Factory-tested components. Plug and play connections. Maximum flexibility for moves, adds and changes (MACs).
As the enterprise strives to be more competitive, the organization must be able to dynamically and rapidly transform its communication and technology infrastructure for future growth.
Total Cost of Ownership
Call 1-800-626-0005www.hubbell-premise.com 5
Security
Impact Increased revenue - protection of proprietary information. Increased customer confidence.
DesignObjectives
Control access to data center. Factory-sealed components. Limit physical access to network connections. Intrinsically secure media. Use fault-tolerant connections.
Protection of mission critical data, adherence to regulatory requirements and defending against unauthorized access to equipment are key requirements for todays data center environment.
Space Utilization
Impact Lower operating expense.
DesignObjectives
Minimize number of connections. Maximize connection density. Maximize floor space utilization. Minimize cable pathway congestion. Maximize rack and cabinet utilization.
Maximizing utilization of expensive data center real estate is a key to controlling operating expenses.
Aesthetics
Impact Positive customer perception - internal pride.
DesignObjectives
Covered cable management. Stylized equipment racks and cabinets. Minimize clutter and cable congestion.
The Data Center is a reflection of the proficiency and the capability of the enterprise.
Hubbell can help you minimize the Total Cost of Ownership of your data center operation by providing you with solutions that exceed all of the design objectives. Minimize start-up costs, downtime and operating costs and maximize long-term reliability. All under the protection of the Hubbell 25-year MISSION CRITICAL Cabling System Warranty.
6 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
MTP Plug and Play12 strand fiber has much smaller profile than equivalent
UTP - removing a significant obstacle from air handling spaces.
Factory-sealed cassettes ensure secure connection. Optical fiber is immune to signal tapping.
Fewer cables eliminate unsightly clutter. Splicing connections concealed within cassette
enclosure.
Factory-terminated multimode and singlemode 12-fiber fanouts reduce onsite installation time.
100% optically tested for reliable performance. 12-Fiber MTP building cables with pulling grip attached. MTP keyed connector eliminates polarity questions.
High bandwidth fiber transmits more data per cable for optimum use of cable pathways.
Reduced cable congestion makes it easier to identify and trace ports and cables.
OCLC62 MTP Cassette
Laser optimized 50 micron fiber for 10GbE applications.
Reduces time to prepare for new servers by 50%.
Reduces cable bulk and improves airflow in plenum spaces, extendingequipment life.
Factory-terminated and tested cable assemblies increase reliability and minimize installationexpense.
Call 1-800-626-0005www.hubbell-premise.com 7
y MTP Plug and Play SystemMTP Plug and Play CassettesConnector Type Fiber Type Catalog No.SC Duplex 50m OCSC50SC Duplex 50m, 10GbE OCSC50GSC Duplex 62.5m OCSC62SC Duplex SM OCSCSMST-style 50m OCST50ST-style 62.5m OCST62ST-style SM OCSTSMLC Duplex 50m OCLC50LC Duplex 50m, 10GbE OCLC50GLC Duplex 62.5m OCLC62LC Duplex SM OCLCSMLC Quad 50m, 10GbE OCLCQ50GMT-RJ 50m OCRJ50MT-RJ 62.5m OCRJ62
MTP to MTP 12-Fiber Cords with Pulling GripFiber Type Length Catalog No.50m 10m FPCMTP501050m, 10GbE 10m FPCMTP50G1062.5m 10m FPCMTP6210SM 10m FPCMTPS1050m 25m FPCMTP502550m, 10GbE 25m FPCMTP50G2562.5m 25m FPCMTP6225SM 25m FPCMTPS2550m 50m FPCMTP505050m, 10GbE 50m FPCMTP50G5062.5m 50m FPCMTP6250SM 50m FPCMTPS5050m 100m FPCMTP5010050m, 10GbE 100m FPCMTP50G10062.5m 100m FPCMTP62100SM 100m FPCMTPS100Custom MTP cords available upon request.
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete fiber offering.
System
Photo at left shows the MTP Plug and Play components OCLC62 MTP Cassette and FPCMTP50G10 12-Fiber Cord with Pulling Grip.
FPCMTP50G10 12-fiber cord with pulling grip
8 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
Fiber ConnectionsSmaller cross section of fiber cords and cables saves
valuable plenum and cabinet spaceOptical fiber cables and cords do not carry electrical
energy and therefore, have no heat to dissipate.
Optical fiber is immune to signal tapping.
Fewer cables eliminate unsightly clutter.
2CLICK no epoxy, no polish connectors allow prompt response if you require a connector change in the field.
Fiber adapter panels snap in and out of all enclosures for easy customization and rapid change-outs.
High bandwidth fiber transmits more data per cable for optimum use of cable pathways.
Individual channels labeled on all patch cords from the factory.
72-fiber LC Trunk Cable
Laser optimized 50 micron fiber for 10GbE applicationsextends life ofinvestment.
Reduces cable bulk and improves airflow in plenum spaces, extending equipment life.
Factory-terminated and tested cable assemblies increase reliability.
Call 1-800-626-0005www.hubbell-premise.com 9
Other adapter colors are available. Pigtails, Patch Cords and Multifiber trunk cables are available in various cable styles. Please consult our Full Line Catalog for the complete fiber offering.
2CLICK Pre-Polished LC ConnectorsDescription Catalog No.Multimode, 50m, 10G, 10-pk, Aqua Housing FCLC50GM10Multimode, 62.5m, 10-pk, Beige Housing FCLC62M10Singlemode, 10-pk, Blue Housing FCLCSM10
2CLICK Pre-Polished SC ConnectorsDescription Catalog No.Multimode, 50m, 10G, 10-pk, Aqua Housing FCSC50GM10Multimode, 62.5m, 10-pk, Beige Housing FCSC62M10Singlemode, 10-pk, Blue Housing FCSCSM10
FSP Loaded Adapter Panels - LC Duplex - Phosphor Bronze Sleeves - MM Applications# Fibers # Adapters Type Version Catalog No. 12 6 LC Duplex Beige Standard FSPLCDM6 12 6 LC Duplex Aqua High-Density FSPLCDM6AQ
FSP Loaded Adapter Panels - LC Quad - Phosphor Bronze Sleeves - MM Applications# Fibers # Adapters Type Version Catalog No. 12 3 LC Quad Beige Standard FSPLCQM3 12 3 LC Quad Aqua Standard FSPLCQM3AQ 24 6 LC Quad Beige High-Density FSPLCQM6 24 6 LC Quad Aqua High-Density FSPLCQM6AQ
FSP Loaded Adapter Panels - LC Duplex - Zirconia Sleeves - SM Applications# Fibers # Adapters Type Version Catalog No. 12 6 LC Duplex Blue Standard FSPLCDS6
FSP Loaded Adapter Panels - LC Quad - Zirconia Sleeves - SM Applications# Fibers # Adapters Type Version Catalog No. 12 3 LC Quad Blue Standard FSPLCQS3 24 6 LC Quad Blue High-Density FSPLCQS6
FSP Loaded Adapter Panels - SC Duplex - Phosphor Bronze Sleeves - MM Applications# Fibers # Adapters Type Version Catalog No. 12 6 SC Duplex Beige Standard FSPSCBE6 12 6 SC Duplex Aqua Standard FSPSCDM6AQ
FSP Loaded Adapter Panels - SC Duplex - Zirconia Sleeves - SM Applications# Fibers # Adapters Type Version Catalog No. 12 6 SC Duplex Blue High-Density FSPSCDS6
FTR Tray - FSP Adapter Panel VersionCapacity Rack Units Catalog No.3 FSP adapter panels 1 FTR175SP6 FSP adapter panels 2 FTR350SP3612 FSP adapter panels 3 FTR525SP15 FSP adapter panels 4 FTR700SP
FCR Rack Mount EnclosuresAccepts Height Rack Units Catalog No.6 FSP series adapter panels 3.50 (89) 2 FCR350SP36R9 FSP series adapter panels 3.50 (89) 2 FCR350SP54R12 FSP series adapter panels 5.25 (133) 3 FCR525SPR 15 FSP series adapter panels 7.00 (178) 4 FCR700SP
Photo at left shows a Make-to-Order 72-fiber LC Trunk Cable and Single-Fiber Pigtails.
Fiber Connections
10 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
Ascent 10GbE System
10GbE bandwidth per cable minimizes cable count, improving appearance.
Stylized panel aesthetics.
Designed specifically for 10GbE applications providing a solid foundation for critical data intensive applications.
Termination time reduced by 75% through the use of quick lace design and the TX4PP 1-Punch tool.
Angled UDX panels eliminate horizontal cable management allowing for maximized rack space utilization.
High density 36- and 48-port UDX panels maximize the total amount of jacks for each rack unit.
All NEXTSPEED Ascent 10GbE components have provisions for labeling for easy administration.
Hubbell complements each product with standardized labels and software to simplify the task of identification.
PC6AGY03Patch Cord
HXJ6AGY Jacks
Supports a maximum bandwidth beyond 500MHz, extending life of investment.
Cat 6A UTPdelivers PoE moreeffectively than5e, reducingutility expenseby more than 50%.
Call 1-800-626-0005www.hubbell-premise.com 11
m
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete UTP offering.
NEXTSPEED Ascent 10GbE System
NEXTSPEED Ascent Patch Panels, 10GbEDescription Wiring Catalog No.24-port, 1 Rack U, Black Universal Wiring P6A24U48-port, 2 Rack U, Black Universal Wiring P6A48U96-port, 4 Rack U, Black Universal Wiring P6A96U24-port, 1 Rack U, Silver Universal Wiring P6A24US48-port, 2 Rack U, Silver Universal Wiring P6A48US96-port, 4 Rack U, Silver Universal Wiring P6A96US
NEXTSPEED Ascent Patch Cords, Cat 6ADescription Wiring Catalog No.Patch Cord, Stranded Cat 6A T568B PC6AXXXXXX=Color: BK=Black, B=Blue, DG=Dark Gray, GN=Green, GY=Gray, OR=Orange, Y=Yellow.XX = Length: 03 = 3, 05 = 5, 07 = 7, 10 = 10, 15 = 15, 20 = 20.
NEXTSPEED Ascent UTP Cable, 10GbE/Cat 6ADescription Type Catalog No.UTP Cable, Category 6A, Solid Plenum C6ASPXXUTP Cable, Category 6A, Solid Riser C6ASRXXXX=Color: B=Blue, GN=Green, GY=Gray, OR=Orange, W=White, Y=Yellow.
NEXTSPEED Ascent 6-110 Block Kit, 10GbE/Cat 6ADescription Type Catalog No.64-Pair Kit with legs* Universal 6110FTK64WL64-Pair Kit w/o legs* Universal 6110FTK64NL192-Pair Kit with legs* Universal 6110FTK192WL* 6-110, 4-pair connecting clips.
Keystone Jack Panels (Unloaded)Style Height Ports Color Catalog No.High-Density 1U (1.75) 48 Black UDX48E1UMultimedia 2U (3.50) 48 Black UDX48EAngled 2U (3.50) 48 Black UDXA48
XCELERATOR Modular Jacks, 10GbEDescription Wiring Catalog No.XCELERATOR Jack, 10GbE 1 HXJ6AXXXX=Color: AL=Almond, BK=Black, B=Blue, EI=Electric Ivory, GY=Gray, GN=Green, LA=Light Almond, OW=Office White, OR=Orange, P=Purple, R=Red, TI=Telco Ivory W=White, Y=Yellow.Add 25 to the end of the Catalog No. for 25-Pack option.
Photo shown at left includes the components of Hubbells Ascent 10GbE System (P6A24US and P6A48US Patch Panels, HXJ6AGY Jacks, 6110FTK64WL Punch Down Blocks, PCGAGY03 Patch Cords and C6ASPB Cable).
P6A24US
P6A48US
C6ASPB Cable
6110FTK64WL
12 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
Shielded 10GbE Syst
One-piece shielded jack construction. Smaller cable diameter reduces cable congestion.
10GbE FTP cables reduced OD optimizes airflow throughout the infrastructure.
Shielding protects against signal tapping and EMI.
The NEXTSPEED shielded 10GbE enhanced performance FTP cabling system is designed specifically for 10GbE applications and provides a solid foundation for critical data intensive applications.
Tool-less jack termination reduces FTP termination under 2 minutes.
PSJ24 UDX panels maximize the total amount of shielded jacks for 1 rack unit.
All NEXTSPEED shielded 10GbE components have provisions for labeling for easy administration.
SJ62B Jacks
PS603GYPatch Cord
Elimination of AXT and EMI,minimizing trouble-shootingand downtime.
Supports a maximum bandwidth beyond 500MHz, extending life of investment.
Call 1-800-626-0005www.hubbell-premise.com 13
tem
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete shielded offering.
NEXTSPEED Shielded 10GbE System
NEXTSPEED Shielded Jacks, Category 6/10GbEDescription B-Wired Catalog No. A-Wired Catalog No.Shielded Jack, Category 6/10GbE, 2-pack SJ62B SJ62AShielded Jack, Category 6/10GbE, 24-pack SJ624B SJ624A
NEXTSPEED Shielded Patch Panels, UnloadedDescription Wiring Catalog No.Shielded Patch Panel, 24-port, 1U, Gray Universal PSJ24
NEXTSPEED Shielded Patch Cords, Category 6/10GbEDescription Wiring Catalog No.Shielded Patch Cord, Stranded Patch Cable T568B PS6XXXXXX = Length: 03 = 3, 05 = 5, 07 = 7, 10 = 10, 15 = 15, 20 = 20, 25 = 25.XX = Color: B=Blue, GY=Gray.
NEXTSPEED FTP Cable, Category 6/10GbEDescription Type Catalog No.FTP Cable, Category 6A, Solid Plenum C6FTPSPXXFTP Cable, Category 6A, Solid Riser C6FTPSRXXXX=Color, B=Blue, GY=Gray, PK=Pink, W=White.
Photo at left shows components of the Hubbell Shielded 10GbE System including PSJ24 Panel, SJ62B Jacks, PS603GY Patch Cords and C6FTPSB Cable.
C6FTPSBCable
PSJ24
14 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
25-Pair Gigabit Ass
Fewer cables eliminate unsightly clutter. Condense cable channel congestion.
25 pair cable much smaller profile than equivalent 6-cable bundle of 4 pair UTP.
Frees up valuable space in the cabinet and in the floor for maximum airflow.
25-pair cable assemblies fasten to the rear of panel securing the connection onto the panel eliminating errant terminations.
Third party verification to IEEE 802.3ab. Create a plug and play connection within the data center
easily interfacing between switches (RJ21X) or standard patch panels (RJ45).
Bandwidth beyond 100MHz.
High-density configuration optimizes valuable rack space. Condensed cable size results in smaller cable channels,
minimizing floor space footprint.
Much easier to track and manage a single 25-pair cable versus 6 4-pair UTP cables.
Substantiallyreduces time toprepare for new servers.
Reduces cable bulk and improves airflow in plenum spaces.
Factory-terminated and tested cable assemblies increase reliability.
Call 1-800-626-0005www.hubbell-premise.com 15
emblies1000BASE-T Patch PanelDelivery: 1 1000BASE-T patch panel, 4 mounting screws, 4 cable assembly screws.Finish: Durable, black powder coat. Ports Height Width Depth Connectors Catalog No.
24 1.75 (45) 19 (483) 1.2 (31) Female PG24 48 3.50 (89) 19 (483) 1.2 (31) Female PG48
25-Pair Cable AssembliesDelivery: 1 cable assembly supplied with mounting screws, male-to-male connectors and a choice of various connector configurations.Connector Angles Gender Catalog No.180 to 90 Male-to-Male 525G21XXE* 180 to 180 Male-to-Male 525G22XXE*110 to 110 Male-to-Male 525G33XXME** XX denotes Length in feet: 05=5 feet, 10=10 feet, 15=15 feet.
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete high pair count offering.
Photo at left shows components of the Hubbell 25-Pair Gigabit Cable Assemblies including the PG48 Patch Panel with the 525G2210E 25-Pair Cable Assembly.
PG48Patch Panel
525G2210E 25-pair GigabitCable Assembly
25-Pair Gigabit Assemblies
16 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
Vertical Patch Panel
Double door provides open access to cable, conceals large cable channel.
Concealed horizontal cable and short jumper connections result in nice neat installations.
Stylized look enhances appearance of any computer room.
Places data and KVM ports at each rack unit allowing use of short connecting cables and eliminating cable that would otherwise restrict airflow.
Accommodates primary, secondary and tertiary data ports at each rack position.
Options supporting 1GbE, 10GbE and optical fiber ensuring plenty of bandwidth.
By moving data connections along side of cabinet, 2 rack spaces are freed for the use of additional equipment.
Much easier to identify and trace ports and cables.
Eliminates 1000of cable in each cabinet whenfully loaded.
Substantiallyreduces time toprepare for new servers.
Modular construction provides migration path and scalability.
Call 1-800-626-0005www.hubbell-premise.com 17
Vertical Patch PanelDelivery: 1 75 section, 2 Rolls of 10 VELCRO brand ONE-WRAP cable ties, 1 Kit installation hardware, 8 #12 attachment screws.Description No. of Data Module Locations Catalog No.iFRAME Vertical Patch Panel for 15 VPHHubbell iFRAME Server Cabinet
Data ModulesData Module # Ports/module Panel Use Catalog No.1GbE Data Module 6 port Fits into Vertical Patch Panel Data Module VPP1G(25-pair) module opening to terminate 25 pair 1GbE cable assembly.
Blank Covers 0 Covers unused Data Module Openings VPMB(10-pack)
iSTATION 8 Each bezel (VPMI) accepts 4 two-port VPMIModule Bezel modules (IM2K1GY), which snap into VPMI for data applications where individual jacks are desired (color coding, 10GbE).
iSTATION Module, 2 Each module accepts 2 HXJ jacks or IM2K1GY2-port, gray AV inserts and snaps into VPMI.
10GbE (55m) 6 Fits into Vertical Patch Panel data VPPC6Module, 6-port module opening for use with Cat 6 UTP (10GbE - TSB-155)
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete Vertical Patch Panel offering.
VELCRO and ONE-WRAP are registered trademarks of Velcro Industries B.V.
Photo at left shows the VPH vertical patch panel connecting one-to-one to servers, minimizing patch cord cost and air blockage.
Hubbell Vertical Patch Panel Catalog No. VPH
Hubbell 10GbE Jacks mounted in Vertical Patch Panel.
Vertical Patch Panels and Data Modules
18 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
Server Cabinet
Stylized look enhances appearance of any computer room.
IN-FRAME design facilitates consistent cabinet ganging.
IN-FRAME design optimizes airflow by creating designated cable pathways away from center of cabinet.
Designed for HOT AISLE/COLD AISLE cooling. Mounting rails fasten directly to frame preventing
airflow slippage around equipment.
3-Point door locking system. Optional locks for side covers.
Cable pathways are open facilitating movement and additions of servers.
Rack positions are identified on all four uprights aiding the installation of new gear.
Cable management spools snap into place.
Optional split rails kit maximizes cabinet utilization by accommodating servers and switchgear in one cabinet.
Cable management spools with label fields to identify bundles of cable.
Unobscured cable pathways simplify tracing cables.
H1KTTop Kit
2-H1E80E
IN-FRAME design protects investment by allowing framedepth to be increased in the field.
Optimizes cooling,extending life ofactive equipment.
Simplifies adding and moving servers.
Call 1-800-626-0005www.hubbell-premise.com 19
Server CabinetDelivery: 1 Frame 2 Perforated doors, center opening 4 19" Mounting rails (square holes 2 Side panels, flush with M6 cage nuts) 1 Kit of 20 M6 cage nuts, screws and washersFinish: Durable powder coat, black.Description Height Width Depth Catalog No.
Server Cabinet, 80"H 80" 24" 42" H1E80E
Server Cabinet, 80"H, without sides 80" 24" 42" H1E80EX
Server Cabinet, 80"H 80" 24" 36" H1E80ED
Server Cabinet, 80"H, without sides 80" 24" 36" H1E80EDX
Fan TrayDelivery: 1 fan tray assembly, wired, 1 kit mounting hardware.
Description Catalog No.
Fan kit, 114 CFM, 120 VAC, 60 Hz, 36 dBA HWKF120Fan kit, 114 CFM, 230 VAC, 50 Hz, 36 dBA HWKF230Blank plate with 4 fan/PVC conduit cut-out H1KB
Telescopic Equipment ShelfDimensions: 16.65W x 29.2D. Load capacity: 200 lbs.Delivery: 1 shelf pre-assembled with telescopic slides, 2 rear mounting brackets and 1 kit mounting hardware.Color Catalog. No.
Black CKTSD
Stationary Equipment ShelfDimensions: 17.69W x 29.29D.Delivery: 1 shelf, washers, cage nuts, (4) #12-24 mounting screws, washers, cage nuts.Color Catalog. No.
Black CKSSD
Top PlateIncludes 1 Mounting Plate, 4 snap in spools, 1 kit mounting hardware. Catalog No. H1KT
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete Server Cabinet offering.
Photo shown at left shows two H1E80E Server Cabinets with H1KT Cable Management Top Kits.
Server Cabinets and Accessories
20 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
Network Cabinet
Stylized look enhances appearance of any computer room.
IN-FRAME design manages and conceals cable bundle.
IN-FRAME design optimizes airflow by creating designated cable pathways away from center of cabinet.
Can be used in front to rear, side to side, and bottom to top airflow configurations.
Optional top keeps cable clear of fan tray exhaust.
3-Point door locking system. Optional locks for side covers.
Cable pathways are open facilitating movement and additions of servers.
Rack positions are identified on all four uprights aiding the installation of new gear.
Cable management spools snap into place. Optional split rails kit maximizes cabinet utilization by
accommodating servers and switchgear in one cabinet.
Enhanced cable management features allow cable storage within the cabinet.
Much easier to identify and trace ports and cables. Cable management spools with label fields to
identify bundles of cable.Unobscured cable pathways simplify tracing
cables.
H1N84E
IN-FRAME design protects investmentby allowing framedepth to be increased in the field.
Optimizes cooling, extending life ofactive equipment.
Superb cable management reduces administration time and operating expense.
Call 1-800-626-0005www.hubbell-premise.com 21
Networking CabinetDelivery: 1 Frame, 2 Perforated doors, left hinging, 4-19 Mounting rails (#12-24), 2 Side panels, 3 wide for cable management, 1 Kit of 20 dog-nosed screws, #12-24 x 5/8, 16 Cable management spools, snap inFinish: Durable powder coat, black.
Networking Cabinet with Side Covers Overall Overall Catalog No. Catalog No.Rack Units Height Width 32 Depth 36 Depth43 80.7 30 H1N80E H1N80ED45 84.2 30 H1N84E H1N84ED
Networking Cabinet without Side Covers Overall Overall Catalog No. Catalog No.Rack Units Height Width 32 Depth 36 Depth43 80.7 30 H1N80X H1N80XD45 84.2 30 H1N84X H1N84XD
Please consult Hubbell Premise Wiring Full Line Catalog for the complete Premise Cabinet offering.
Vertical Cable Management Options:
Snap in Spools (ICKSS). Vertical Cable Management Rings (HC26VR2). NEXTFRAME Vertical Channels (i.e., VS76H, VS76, VS73) - for use without side covers. Internal Vertical Organizer - for use with 3 side covers. (H1KV80, H1KV84). Concealed by 3 Side Cover.
Photo at left shows an H1N84E Networking Cabinet and some of the cable management features of its IN-FRAME design.
H1KX4 Networking Cabinet and Accessories
Movable snap in spools (Cat. # ICKSS) in top to route cable.
Cable entry with integrated bend relief.
Unobstructed vertical cable pathways far forward and concealed.
22 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
Column System
80% reduction in parts results in dramatic reduction in number of brackets resulting in clean uncluttered appearance*.
Double hinging covers project image of quality. Stylized look enhances appearance of any
computer room. * Compared to traditional relay rack with accessories.
Open design removes all barriers to forced and convective airflow.
Cable pathways are open facilitating movement and additions of servers.
Top ladder pieces cut to length and pre-drilled for 4 square work boxes at factory.
Cable management spools snap into place.
Columns mount on 2 pitch to align with floor and ceiling grids.
1,400 lb. load capacity and 100% utilization of rack space maximizes equipment density per square foot.
Cable management spools with label fields to identify bundles of cable.
Un-obscured cable pathways simplify tracing cables much easier to identify and trace ports and cables.
Maximum coverage of exposed cables enhances security.
Increase usable rackspace per squarefoot of floor spaceby more than 15%.
Installs in half the time of a traditional rack.
Durable componentsdesigned to lastthe life of thecable plant.
Call 1-800-626-0005www.hubbell-premise.com 23
iFRAME ColumnsDelivery:1 iFRAME column weldment, 1 Bottom alignment installation aid and floor template, 1 iFRAME top plate, 1 Full height front cover with dual-acting hinges*, 4 Heavy-duty floor anchor washers, 4 anchors, 4 shims, 20-#12-24 x 5/8 dog point machine screws or M6 hardware for IS7M6, 4 Gates, 4 (ref. Catalog No. VCG4) and washers, 12 Snap in place cable routing spools, 1 Kit assembly hardware.* Not included in IS7E.For use in Applications: Rack Units Height Catalog No.Without raised floor 45 7 IS7Without raised floor 19 3 IS3Raised floor up to 12 high 45 8 IS7RF When using M6 cage nuts 45 7 IS7M6Raised floor up to 12 high using M6 cage nuts 45 8.5 IS7RFM6Raised floor up to 18 high 45 8 IS7RF18As the rear columns in 4-post applications 45 7 IS7ENOTE: Two columns must be ordered for the first rack in a line. Only one column needs to be ordered for each additional rack.
iFRAME Top LadderDelivery: 1 iFRAME 12 wide x 2 top ladder with integrated waterfalls; pre drilled for 4 workbox, 1 kit assembly hardware.Finish: Durable black powder coat.Catalog No. ICKL
Cable Management SpoolsDelivery: Package of 50 spools and screws, 3, black.
Catalog No. ICKSS
Power Strip Mounting BracketsDelivery: 1 pair of brackets and hardware for mounting one Hubbell 66 power strip.
Catalog No. ICKPM
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete Cable Management offering.
Photo at left shows four IS7 7-foot iFRAME Columns in use.
4-IS7 and 3-ICKL mounted on top
Top plate (included with each column) aligns tops of columns and mounting for ladder rack.
IS7 with cable management door closed
IS7 with cable management
door open
24 Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
Cable Management
Un-obscured cable pathways simplify tracing cables.
Open design removes all barriers to forced and convective airflow.
Organizers designed with rounded components to reduce the risk of cold flow and cable kinks to optimize transmission performance.
Cable pathways are easily and completely open facilitating movement and additions of servers.
Modular components can be field configured to meet the unique needs of each application.
Cable management spools with label fields to identify bundles of cable.
Much easier to identify and trace ports and cables.
Maximum coverage of exposed cables enhances security.
Durable componentsdesigned to last the life of the cable plant.
Maximize cable transmission performance.
Call 1-800-626-0005www.hubbell-premise.com 25
tNEXTFRAME 19 Equipment Rack with Z Channels, 6WDelivery: 1 Rack, 7H (HPW84RR19) and 2 vertical organizers (VS76H/VS76)Finish: Durable black powder coat. Rack Height Rack Units Finish Cover Style Catalog No. 7 (2134) 45 Black Hinged CS1976H 7 (2134) 45 Black Clip on CS1976
NEXTFRAME 19 Duct Style Horizontal OrganizersDelivery: 1 organizer, 4 #12-24x5/8 dog-nosed screws and Nylon washers.Panel Height Rack Units Front Ring Depth Rear Ring Depth Catalog No.1.75 1U 3.5 - HC119CE3H3.50 2U 3.5 - HC219CE3N3.50 2U 3.5 4.6 HC219CC3N5.25 3U 3.5 - HC319CE3N
Other NEXTFRAME Components Ladder Rack Center Rack Velcro Cable Ties Wall Mount Racks and Brackets
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete Horizontal Cable Management offering.
VELCRO is a registered trademark of Velcro Industries B.V.
Photo at left shows the CS1976 19 Equipment Rack with 6 Wide Z-Channels and HC219CE3N Duct-Style Horizontal Organizers.
CS1976
NEXTFRAME Cable Management
26 Hubbell Wiring Device-Kellems 185 Plains Road Milford, CT 06461-2420 Fax: (800) 255-1031
TWIST-LOCK Power Devices an
Individually molded face for each blade configuration keeps debris out of plug interior. Integral dust shield. Tough, ribbed Nylon housing for secure gripping.
Prevents unintentional disconnect. Powerful, offsetting cord grips clamp on individual
conductors and outer cord jacket to prevent strain on terminals.
Ribbed nylon housing is impact and chemical resistant.
NEMA locking configurations for easy disconnect when repositioning data center equipment.
KELLEMS strain relief grips prevent conductor pulling, delivering a secure electrical connection.
Flexible cord connections allow equipment to be powered without a rigid infrastructure to work around.
KELLEMS grips support flexible cable, eliminating the need for rigid wire management systems.
Power drops from above remove obstacles from airflow in plenum space.
Amperage and voltage indications are clearly marked on the device for easy identification.
Maximize up-time by preventing unintentionaldisconnects.
Flexible connectionsallow for easyreconfiguration.
Highly engineeredmaterials maximizeconnection reliability at all temperatures.
No need to install arigid power supplyinfrastructure.
Call (800) 288-6000www.hubbell-wiring.com 27
d Kellems GripsConnector BodiesAmps Voltage NEMA Catalog No.
15 125V L5-15R HBL4729C20 125V L5-20R HBL231320 250V L6-20R HBL232330 250V L6-30R HBL2623
PlugsAmps Voltage NEMA Catalog No.
15 125V L5-15P HBL4720C20 125V L5-20P HBL231120 250V L6-20P HBL232130 250V L6-30P HBL2621
ReceptaclesAmps Voltage NEMA Catalog No.
15 125V L5-15R HBL470020 125V L5-20R HBL231020 250V L6-20R HBL232030 250V L6-30R HBL2620
Please consult the Wiring Device-Kellems Full Line Catalog for our complete offering of TWIST-LOCK Power Devices and Pulling and Support Grips.
TWIST-LOCK Devices2-Pole/3-Wire
TWIST-LOCK Devices 3-Pole/4-WireConnector BodiesAmps Voltage NEMA Catalog No.
20 3480V L6-20R HBL243330 3480V L6-30R HBL2733
PlugsAmps Voltage NEMA Catalog No.
20 3480V L6-20P HBL243130 3480V L6-30P HBL2731
ReceptaclesAmps Voltage NEMA Catalog No.
20 3480V L6-20R HBL243030 3480V L6-30R HBL2730
KELLEMS Dustight Strain Relief GripsNon-Insulated - Wide Range Strain ReliefCable Diameter Thread Size Mesh Length @ Range Inches (cm) N.P.T. Inches Nom. Dia. Inches (cm) Catalog No.
.54-.73 (1.37-1.85) 6 (16.51) 073031203
.73-.97 (1.85-2.46) 1 7 (17.78) 073031204
.97-1.25 (2.46-3.17) 1 9 (22.86) 073031205
.73-.97 (1.85-2.46) PG29 7 (17.78) 073PG291204
Insulated - Wide Range Strain ReliefCable Diameter Thread Size Mesh Length @ Range Inches (cm) Inches Nom. Dia. Inches (cm) Catalog No.
.54-.73 (1.37-1.85) N.P.S. 6 (16.51) 073031209
.73-.97 (1.85-2.46) 1 N.P.S. 7 (17.78) 073031210
.97-1.25 (2.46-3.17) 1 N.P.S. 9 (22.86) 0730312111.25-1.5 (3.17-3.81) 1 N.P.T. 11 (29.84) 0730312121.50-1.70 (3.81-4.32) 2 N.P.T. 13 (33.65) 073031213
Photo at left shows a server cabinet connected to power with Hubbell TWIST-LOCK Connector Cord Drops suspended using KELLEMS Grips.
TWIST-LOCK Plug andConnector Body.
KELLEMS Dustight Strain Relief Grip.
IEC Pin and Sleeve High Power
Pin and Sleeve high power devices eliminate clutter and present a clean, orderly appearance.
Insulated, non-metallic housing prevents marring of surfaces.
28
3-phase power cuts down cable bulk in plenum spaces.
IEC Pin and Sleeve devices provide convenient portable power and fast plug and play connections.
Fast, secure connections.
3-phase power optimizes circuit breaker space on Power Distribution Unit breaker panel.
Tapered housings and ergonomic design eliminate bulky connections.
Ratings and certifications are molded into housing and devices are color-coded by voltage rating for easy identification.
Hubbell Wiring Device-Kellems 185 Plains Road Milford, CT 06461-2420 Fax: (800) 255-1031
Shrouding - pins are recessed for user safety and protection against abuse. Solid Pins - dependable solid brass for longer life and reliable electrical contact. Locking ring on plug prevents unintentional disconnect when mounted with receptacle
or connector.Patented opening on plug shroud accommodates lock shackle to comply with OSHA
lockout/tagout requirements.
HBL430C7W Connector Body
3-Phase power optimizes use of site power distribution unit.
Dependable construction for longer life, reliable contact and lessdowntime.
r ConnectionsConnector Bodies Amps Poles/Wires Voltage Catalog No.
30 3P/4W 3480V HBL430C7W 30 3P/4W 3250V HBL430C9W 30 3P/4W 125/250 HBL430C12W 60 3P/4W 3480V HBL460C7W 60 3P/4W 3250V HBL460C9W 60 3P/4W 125V/250V HBL460C12W
Plugs Amps Poles/Wires Voltage Catalog No.
30 3P/4W 3480V HBL430P7W 30 3P/4W 3250V HBL430P9W 30 3P/4W 125/250 HBL430P12W 60 3P/4W 3480V HBL460C7W 60 3P/4W 3250V HBL460C9W 60 3P/4W 125V/250V HBL460C12W
Receptacles Amps Poles/Wires Voltage Catalog No.
30 3P/4W 3480V HBL430R7W 30 3P/4W 3250V HBL430R9W 30 3P/4W 125/250 HBL430R12W 60 3P/4W 3480V HBL460R7W 60 3P/4W 3250V HBL460R9W 60 3P/4W 125V/250V HBL460R12W
Please consult the Wiring Device-KELLEMS Full Line Catalog for the complete Wiring Device Pin and Sleeve offering.
29Call (800) 288-6000www.hubbell-wiring.com
Photo at left shows Hubbell HBL430P7W Plug and HBL430C7W Connector Body.
HBL430P7W Plug
IEC Watertight Pin and Sleeve Devices
30
Unobscured cable pathways simplify tracing cables.
Power Distribution3-phase power delivery reduces cable bulk below
the raised floor eliminating obstacles to airflow.Locating receptacles at each rack position
minimizes length of power cord bulk and eliminates obstacles to airflow.
TWIST-LOCK plugs prevent accidental disconnection of power cords.
Densely located receptacles ensure that there is always power available for new equipment.
Locating receptacles at each rack position minimizes length of power cord and eliminates clutter.
Color coded receptacles are a quick and easy way to identify phases at a glance.
Cable management spools with label fields to identify bundles of cable.
Hubbell Premise Wiring 14 Lords Hill Road Stonington, CT 06378 Tel: (860) 535-8326 Fax: (860) 535-8328
3-phase power optimizes use of site power distribution unit breaker panel.
Improved airflow extends life of active equipment.
Simplifying load balancing reduces energy costs.
Call 1-800-626-0005www.hubbell-premise.com 31
Horizontal Power StripsDelivery: 1 power strip and 1 kit mounting hardware.Finish: Durable black powder coat. Electrical Specification Outlets Front Outlets Rear Catalog Number
15A/120V 0 10 HPWPWR 15A/120V 0 10 MCCPSS19 15A/120V 4 4 MCCPSS19TS 20A/120V 0 10 PR10120 20/16A, 120/250V 10 0 PR10720* 15A/120V 0 6 PR0615 20A/120V 0 10 PR1020 60A/250V 0 3 PR0360*** PR10720 includes an IEC 320 (C-20) inlet for power input. Vertical mount brackets are also included.** PR0360 features 10 cable with IEC 60A 2P/3W plug.
Vertical Power StripsDelivery: 1 power strip and 1 kit mounting hardware.Finish: Durable black powder coat. Electrical Specification Outlets Number of Circuits Catalog Number
15A/120V 10 1 PR104 20A/120V 10 1 PR10420 15A/120V 20 1 PR206 20A/120V 20 1 PR20620 20A/120V 20 1 PR20820DRTL 30A/120V 20 1 PR20830 20/16A /circuit 120V 20 2 PR20820A* 20/16A-120/250V 20 1 PR20820I** 30/24A-250V 24 1 PR24 120V 40 6 PR40Z120**** PR20820A features (2) 20A circuits each fed by 10ft. cable with NEMA 5-20 plug.** PR20820I includes an IEC 320 (C-20) inlet for power input.*** Full length mounting bracket included.
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete Power offering.
Photo at left shows a PR40Z120 40-Outlet Power Strip with 3 input connecting one-to-one with servers using 1-foot power cords with HBL5266C plugs.
Power Distribution
Hubbell Premise WiringHUBBELL INCORPORATED (Delaware)14 Lords Hill Road Stonington, CT 06378-0901(860) 535-8326 800-626-0005 Fax: (860) 535-8328Internet site: http://www.hubbell-premise.com
B-DC1 02/08
Hubbell Premise Wiring, Latin America 305-408-4501 Fax: 305-408-8201Hubbell de Mexico, S.A. de C.V. (5255) 9151-9999 Fax: (5255) 9151-9989Hubbell Premise Wiring, Middle East 971-4-393-4192 Fax: 971-4-393-4194Hubbell Premise Wiring, Puerto Rico 787-855-1075 Fax: 787-855-3265Hubbell-Taian Co., Ltd., Taiwan 886-2-2522-1862 Fax: 886-2-2522-1872Hubbell Premise Wiring, Venezuela 58-212-5156482 Fax: 58-212-6627258
Worldwide LocationsHubbell Premise Wiring, Asia Pacific 852-2836-7131 Fax: 852-2836-7132Hubbell Canada Inc. 905-839-1138 Fax: 905-839-9108Hubbell Premise Wiring, Central America 506-309-4158 Fax: 506-260-1616Hubbell Premise Wiring, China 86-21-6374 2660 Fax: 86-21-6374 2799Hubbell Premise Wiring, Europe 44-01283 500500 Fax: 44-01283 500400Hubbell Wiring Systems, India 91-80-4022-4089 Fax: 91-80-4022-4033Hubbell Intl. Inc., Korea Branch (82 2) 2607 1363 Fax: (82 2) 2603 7386
Empower Your Enterprise With anIntelligent Infrastructure Solution.
High Performance Copper Systems
High Performance Fiber Connectivity
Power Infrastructure Solutions
Data Center Infrastructure
Zone Cabling Systems
Telecommunications Room Infrastructure
Converged Workstation Outlets
Delivery Systems
Harsh Environments
Wiring Devices
KELLEMS Grips
Hubbell Wiring Device-KellemsHUBBELL INCORPORATED (Delaware)185 Plains Road Milford, CT 06461-2420 (203) 882-4800 (800) 288-6000 Fax: (800) 255-1031Internet site: http://www.hubbell-wiring.com
02/08
Twist-Lock, Kellems, iFRAME, NEXTSPEED, OPTICHANNEL, NEXTFRAME are all registered trademarks of Hubbell Incorporated (Delaware).
RoHSRoHS