E U R O P EDADANCO
Active Chilled Beams
1
ACB20 (2-way)
ACTIVE CHILLED BEAMS
2
The new low height twin vertical coil ACB20 (2-way)
active chilled beam avoids all the concerns with using
inferior inclined coil beams, without exceeding a height
of 286mm. The new ACB20 utilizes DADANCO’s unique
nozzle and unit fluid dynamics technology.
This patented technology provides very high air
entrainment ratios at low pressure drops and provides
the major benefit of superior performance delivered at
the lowest noise levels.
Typical Performance Data
Primary airflow
8 to 80 L/s @ Static pressure range of 50 - 175 Pa
Secondary Chilled Water
0.03 - 0.15 L/s
Performance Range
500 - 2,000 W
Typical Product Data
Length - 600 to 3000mm.
Width - Typically to suit T-Bars at 600mm centers, with fat and
tegular edge border styles as standard.
Appearance - Traditional perforated face.
Discharge - 2 way.
Coil - Vertical 2 or 4 pipe option with drip trays and sweat
or NPT fittings.
Primary air connection - Side or top entry as standard.
DADANCO Active Chilled Beams have been tested both
in-house and independently at ETL Laboratories.
DADANCO Technology
Conventional Nozzles DADANCO Nozzles
E U R O P EDADANCO
3
‘Even with a reduced height there is no loss of performance, from the new ACB20, over its predecessor.’
ATC
COIL
COILRF
Secondary Heat Exchangers
Cross-Section of ACB20 Active Chilled Beam
Primary Air Plenum
Supply Air Grille (x2) Return Air
Grille
Condensate Safety Trays with Drains
ACB20 units icorporate 2 secondary water heat exchangers. Secondary heat exchangers must be field connected in a parallelarrangement with control and balancing valves as specified in themechanical specification for the project.
Connection must be parallel to ensure secondary air coolingperformance as specified will be delivered by each unit.
Do not connect secondary heat exchangers in series. Secondarycooling performance will be adversely affected if system designentering secondary water is not delivered equally to both heatexchangers.
Product Details ACB20
Secondary water connections
E U R O P EDADANCO
AIR
INL
ET
CO
NN
EC
TIO
N(S
EE
TA
BLE
3 F
OR
D
IME
NS
ION
OP
TIO
NS
)
12 '' C
OIL
CO
NN
EC
TIO
N(S
EE
TA
BLE
2 F
OR
A
VA
ILA
BLE
OP
TIO
NS
)
No
te: W
hile
eve
ry effo
rt is ma
de
to e
nsu
re th
e d
eta
ils c
on
tain
ed
in th
is p
ub
licatio
n a
re c
urre
nt a
nd
up
-to-d
ate
, in th
e in
tere
st o
f ong
oin
g p
rod
uct d
eve
lop
men
t DA
DA
NC
O E
UR
OP
E re
se
rve
s th
e rig
ht to
alte
r the
sam
e w
itho
ut n
otice
Draw
1
MA
TERIA
L:
A4
SHEET 1 O
F 1S
CA
LE:
TITLE:
UN
LESS
NO
TED
OTH
ER
WIS
EA
LL DIM
ENS
ION
IN m
m
AN
GU
LAR
TOL: 1.0°
LINE
AR
TOL:±1.50m
m
DA
TE
AC
B 20/21(2WA
Y)
AC
B 20/21 SUB
MITTAL D
RA
WIN
G
22. 3. 2016.
DAD
AN
CO
EU
RO
PE
PR
OJE
CT N
AM
E
DES
IGN
:
REV
IEW:
CE
RTIFE
D:
TA
BL
E 2
AV
AIL
AB
LE
OP
TIO
NS
Ø1/2
'' O.D
.SW
T C
ON
NE
CT
ION
Ø1/2
'' FE
MA
LE
NP
T C
ON
NE
CT
ION
Ø1/2
'' MA
LE
NP
T C
ON
NE
CT
ION
AC
B21
2
AC
B2
14
AC
B2
16
AC
B2
18
AC
B2
11
CO
DE
LE
NG
TH
WID
TH
RE
F L
RE
F W
59
5
11
95
17
95
23
95
29
95
59
54
38
103
8
163
8
22
38
28
38
56
4
TA
BL
E 1
59
5
59
5
59
5
59
5
56
4
56
4
56
4
56
4
TA
BL
E 3
RE
F.
DIA
ME
TE
R
80
100
125
150
160
200
RO
UN
D
RO
UN
D
RO
UN
D
RO
UN
D
RO
UN
D
ELIP
SE
Government, Institutional & Defense Buildings
Hospital & Healthcare………………
Schools & Universities……………
Commercial Offices……………
Green Renovations………
Laboratories………
Hotels……
Bulevar Mihajla Pupina 16V 11070 Novi Beograd Republic of Serbia Tel: +381 11 367 57 64
www.dadancoeu.com
Tel: +381 11 367 57 82
E U R O P E