YOU ARE DOWNLOADING DOCUMENT

Please tick the box to continue:

Transcript
Page 1: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.

ABX Air Ground FireABX Air Ground Fire

Joseph Panagiotou

Fire Initiation

Page 2: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.

Supernumerary Compartment

Page 3: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.

Oxygen Mask Enclosure

Page 4: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.

Area of Fire Origin

Page 5: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.

Melted Stainless Steel

Page 6: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.

Oxygen Hose Tests

Two types of tests conducted

• Ignition by electrical current

– Internal heating– Simulate short circuit

• Ignition by external heat source

– Simulate response to fire

Page 7: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.

Oxygen Hose Test Video

Page 8: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.

Test Conclusions

• Internal heating

– Pop/bang similar to firecracker– Hissing

• External heating

– No loud pop/bang– Hissing

• Fire resembled cutting torch

Page 9: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.

Test Conclusions

• Noises heard by crew consistent with conductive and combustible oxygen hose ignition by short circuit

• Oxygen hose design brings together

– Ignition source– Fuel– Oxidizer

Page 10: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.

Fire Initiation

• Melted stainless steel elbow

• Crew observations

• Oxygen hose tests

• Fire initiated due to electrical current passing within conductive and combustible oxygen hose

Page 11: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.

Smoke Detectors

• No smoke detectors required in supernumerary compartment

• No smoke detectors in occupied areas

• Supernumerary compartments not always occupied

Page 12: ABX Air Ground Fire Joseph Panagiotou Fire Initiation.