YOU ARE DOWNLOADING DOCUMENT

Please tick the box to continue:

Transcript
Page 1: 1377 Produktblatt Trias tsa engl v1 - Trias İmplant Türkiye fileThe Trias®tsa female with circle snap system is placed onto the post in such way that the internal hexagon of the

The Trias®tsa post is screwed into the implants using the socket wrench

(short or long) and the torque ratchet with torque of 30 Ncm for fixed denture

prosthesis (bridges) and of 25 Ncm for complete denture prosthesis.

Indi

catio

n

Trias®titanium-shock-absorber

Proc

edur

e

The Trias®tsa abutment contains an integrated damping element inside the post. Thus it guarantees optimal biomecha-

nical properties and enables an even force distribution to prosthesis, bones and inserted implants.

In this way prosthesis fractures can be considerably reduced. The transverse resilience and the 17° cone of the

Trias®tsa post allow a correction of divergence of up to 38°. The Trias®tsa abutment is designed as support for complete denture

prosthesis in the lower or upper jaw. It is available for implant diameter of 3.8 mm. As for a prosthetic bridge provision (either

implant / implant or implant / natural abutment tooth), the Trias®tsa post is alternatively available for fixed dentures.

The prosthesis can be placed both directly into the mouth of the patient and indirectly by means of impression taking and model making in

the dental lab. For that, impression posts and model analog of the Trias® implant system can be used.

Artikel-Nr.

857381tra H1 for fi xed prosthesisTrias®tsa post for implant diameter of 3.8 mm (or larger)Distance height of 1 mm for fi xed dentures (bridges)Distance height of 2 / 3 / 4 mm for complete denture prosthesis857382tra H2 for complete denture prosthesis

857383tra H3 for complete denture prosthesis

857384tra H4 for complete denture prosthesis

857000tra Trias®tsa female

857001tra Trias®tsa model analog (model pin with crown)

857002tra Trias®tsa impression coping or auxiliary modelling element

857003tra Trias®tsa socket wrench – short

857004tra Trias®tsa socket wrench – long

Syst

em E

lem

ents

Page 2: 1377 Produktblatt Trias tsa engl v1 - Trias İmplant Türkiye fileThe Trias®tsa female with circle snap system is placed onto the post in such way that the internal hexagon of the

The Trias®tsa female with circle snap system is placed onto the post in such way

that the internal hexagon of the Trias®tsa female matchs the post’s outer hexagon

and – using light pressure – clicks into place.

To avoid that the used cold-curing polymer flows into inverse conical spaces, rubber

dam rings are fitted over the posts and pulled to below the resilience grooves. In this

way the complete dentures remain removable.

Trias®titanium-shock-absorber

When using an already existing complete denture prosthesis, this will be ground free

at the implant positions. Then add one bead of cold-curing polymer into each present

cavity and place the prosthesis.

After completion of polymerisation, the prosthesis including the Trias®tsa females

can be removed from the posts. Now the rubber dam rings can be removed using

forceps. If needed, excess cold-curing polymer is removed.

Proc

edur

e

Implant dimensions on immediate loading and immediate restoration of 2-4 interforaminally inserted implants

The Trias®tsa abutment allows an immediate restoration including an immediate loading of implants in compliance with the relevant guide-

lines. This relates, for example, to the immediate loading and immediate restoration of two implants placed in region 33/43. A diameter of at least

3.8 mm and a length of 16 mm should be given. Additionally the primary implant stability shall be at least 35 Ncm.

Distribution:

Servo-Dental GmbH & Co. KG

Rohrstraße 30

D-58093 Hagen-Halden

Phone: +49 (0) 2331 - 9591-0

Fax: +49 (0) 2331 - 9591-25

[email protected] | www.servo-dental.de

Stat

us 2

010/

07/1

4

Manufacturer: BoneCare GmbH, Steingasse 1, D-86150 Augsburg


Related Documents