    ORIFICE FLOWMETER

    STEAMGASLIQUID

    RDP-100 RDP-505

  • 8/12/2019 WPG-RDP-E02

    2/16

    RYUTAI KOGYO CO.,LTD. 216

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    ORIFICE FLOWMETER

    RDP-100 are ORIFICE FLOWMETER suitable for

    the steam, the gas, and the liquid which arranged

    an Orifice, DP Transmitter, and Indicator compactly.

    This Flowmeter does not have a movable part and

    it is preeminent for reliability and durability.

    Since D.P. Transmitter is using the shock-proof

    type by the object for high pressures, it is the safedesign which is equal also to severe use.

    The measurement range can perform wide range

    measurement or more in a maximum of 1:10.

    Fluids STEAM GAS LIQUIDS

    Meter SizeAWafer typeJIS10K JIS20K Flange type JIS10K JIS20K

    25 40 50 65 80 100 125 150 25 40 50 65 80 100 125 150 200 250 300 350

    MaterialBody standardSUS304 order)SUS316 standardSGP STPG orderSUS304

    Orifice standardSUS304 order)SUS316 standardSUS304 orderSUS316

    Flow direction

    Accuracy 1 FS

    Max. operating pressure It is based on flange rating.

    Transmitter Power supply 1236V DC 2 wire

    Output signal 420mA DC D.P. proportionality Load Resistance 55024VDC

    Operation temperature 10 200

    Ambient temperature 10 80

    Ambient humidity 0 100 RH without dew condensation

    Options Manifold ValveSUS316I recommend installation.

    Horizontal and Vertical

    Transmitter max. pressure 13.8 MPa

    Model

    RDP100UgasliquidRDP100US steam

    RDP100UM gas mani.valveRDP100USMsteam mani.valve

    RDP100FgasliquidRDP100FS steam

    RDP100FMgas mani.valveRDP100FSMsteam mani.valve

    Indicator Model RVF36A1XBXA Extraction of a square root function

    Power supply 85264 V AC 5060 Hz Power consumption10VA

    Flow rate display Red 5 figures of LED (upper row) Simultaneous display

    Totalizing flow display Red 8 figures of LED (lower berth) Simultaneous display

    Input signal 420mA DC 2 wire

    Power supply for Transmitter 24V DC 40mA 2 wire

    420mA DC Proportional to Flow rate 12 bit4096 Load Resistance 750

    Scaled pulse Open collector 30V DC 50mA Max.

    Ambient humidity 0 50 3080 RH without dew condensation

    Output signal

    Input signal Low cut 0.01 10.00

    RVF-36A-1-XBXA serves as standard attachment by the model designed to exclusive use according to PDP-100.

    RVF-36A-1-XBXA

  • 8/12/2019 WPG-RDP-E02

    3/16

    RYUTAI KOGYO CO.,LTD. 316

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    Fluids STEAM GAS LIQUIDS

    Meter SizeAWafer typeJIS10K JIS20K Flange type JIS10K JIS20K

    25 40 50 65 80 100 125 150 25 40 50 65 80 100 125 150 200 250 300 350

    MaterialBody standardSUS304 order)SUS316 standardSGP STPG orderSUS304

    Orifice standardSUS304 order)SUS316 standardSUS304 orderSUS316

    Flow direction

    Accuracy 1 FS

    Max. operating pressure It is based on flange rating.

    Transmitter Power supply 10.555V DC 2 wire

    Output signal 420mA DCFlow rate proportionality 2 wier Load Resistance 55024VDC

    Operation temperature 10 200

    Ambient temperature 10 80 Explosion proof1070

    Ambient humidity 0 100 RH without dew condensation

    Options Explosion proof TS EXsdCT5 Manifold ValveSUS316 RVF-36A-1-XBXA

    Horizontal and Vertical

    Transmitter max. pressure 25 MPa

    Model

    RDP505Ugasliquid

    RDP505US steam

    RDP505UM gas mani.valveRDP505USMsteam mani.valve

    RDP505Fgasliquid

    RDP505FS steam

    RDP505FMgas mani.valveRDP505FSMsteam mani.valve

    Indicator Model RVF36A1XBXA

    Power supply 85264 V AC 5060 Hz Power consumption10VA

    Flo rate display Red 5 figures of LED (upper row) Simultaneous display

    Totalizing flow display Red 8 figures of LED (lower berth) Simultaneous display

    Input signal 420mA DC 2 wire

    Power supply for Transmitter 24V DC 40mA 2 wire

    420mA DC Proportional to Flow rate 12 bit4096 Load Resistance 750

    Scaled pulse Open collector 30V DC 50mA Max.

    Ambient humidity 0 50 3080 RH without dew condensation

    Output signal

    Input signal Low cut 0.01 50.00

    In model RDP-505, RVF-36A-1-XBXA serves as an option.

    RVF-36A-1-XBXA Option

    RDP-505 are ORIFICE FLOWMETER suitable for the steam, the

    gas, and the liquid which arranged an Orifice, DP Transmitter,

    and Indicater compactly.

    This Flowmeter does not have a movable part and it is

    preeminent for reliability and durability.

    Since DP Transmitter is using the shock-proof type by theobject for high pressures, it is the safe design which is equal

    also to severe use.

    The measurement range can perform wide range

    measurement or more in a maximum of 1:10.

    ORIFICE FLOWMETER

  • 8/12/2019 WPG-RDP-E02

    4/16

    RYUTAI KOGYO CO.,LTD. 416

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    Outside dimension

    Size L d D H Weight kg

    25A 100 27.6 74 340 7.0

    40A 100 41.6 89 345 7.5

    50A 100 52.9 104 355 8.5

    65A 100 67.9 124 365 10.5

    80A 100 80.7 134 370 11.0

    100A 100 105.3 159 380 14.5

    125A 100 130.8 190 395 18.5

    150A 100 155.2 22 410 22.0

    RDP-100 Wafer for STEAM

    RDP-100 Flange for STEAM

    RDP-505 Wafer for STEAM

    RDP-505 Flange for STEAM

    Size L d D H Weight kg

    25A 180 27.6 125 340 8

    40A 180 41.6 140 345 9

    50A 180 52.9 155 355 10

    65A 200 67.9 175 365 12

    80A 200 80.7 185 370 13

    100A 200 105.3 210 380 16

    125A 200 130.8 250 395 20

    150A 200 155.2 280 410 23

    200A 200 200 330 580 27

    250A 200 249 400 615 40

    300A 200 300 445 630 46

    350A 200 333 490 650 58

    C

    90

    105

    120

    140

    150

    175

    210

    240

    290

    355

    400

    445

    BOLT

    M164

    M164

    M164

    M164

    M168

    M168

    M208

    M208

    M2012

    M2212

    M2216

    M2216

    14

    16

    16

    18

    18

    18

    20

    22

    22

    24

    24

    26

    JIS10K Wafer type mm

    JIS10K Flange type mm

    An eyebolt is attached more than 50A.

    The form of DP Transmitter and magnitude have adifference of the appearance of RDP-100 and

    RDP-505, and RDP-505 become somewhat small.

    An eyebolt is attached more than 50A.

    d dimension may change with piping quality of the materials.JIS16K JIS20K L dimension 25A-150A are the same as JIS10K.JIS16KJIS20K L dimension 200A-350A are set to 250mm.

    An eyebolt is attached more than 50A.

    An eyebolt is attached more than 50A.

  • 8/12/2019 WPG-RDP-E02

    5/16

  • 8/12/2019 WPG-RDP-E02

    6/16

    RYUTAI KOGYO CO.,LTD. 616

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    Electric Wiering

    RVF-36A-1-XBXA

    RVF-36A-1-XBXA

    When RDP-505 supply 24VDC power sources, the 4 to20mADC signal

    proportional to Flow rate is outputted.

    Flow rate display, Totalizing flow display, a pulse output, 4 - 20mADC output,

    and the various functions method of application become possible by using

    RVF-36A-1-XBXA.

    In the zero point adjustment whose Flow rate uses the check and drain valve

    of an output signal in zero, COM and a TEST terminal connect and use a

    tester.

    Since there is no Display (RVF-36A) with waterproofing structure, attachment

    to the outdoors cannot be performed.

    When RDP-100 supply 24VDCPower(s), 4 - 20mADC signal

    proportional to diff.press. is outputted.

    Flow rate display, Totalizing flow display, a pulse output, 4 -

    20mADC output, and the various functions method of application

    become possible by using RVF-36A-1-XBXA.

    In the zero point adjustment whose Flow rate uses the check and

    drain valve of an output signal in zero, COM and a TEST terminal

    connect and use a tester.

    Since there is no Display (RVF-36A) with waterproofing structure,

    attachment to the outdoors cannot be performed.

    RDP-100 Terminal details

    RDP-505 Terminal details

    Electric wire connection

    G1/2 or NPT1/2 Two

    Electric wire connection

    G1/2 or NPT1/2 Two

  • 8/12/2019 WPG-RDP-E02

    7/16

    RYUTAI KOGYO CO.,LTD. 716

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    In the case of othersWhen there are two elbows in an entrance side: More than 18DWhen the globe valve of full admission is in an entrance side: More than 20DWhen the partition valve of full admission is in an entrance side: More than 20DAll outlet sides are required more than 6D.It is D= piping bore here.

    Notes

    The straight of the regular length is needed for the entrance side of Flowmeter, and an outlet side, respectively.

    Straight length changes with a piping situation, existence of a valve, etc.

    Keep in mind that accuracy worsens when there is no regular straight length.

    Please unite the flow direction of Flowmeter, and the flow direction of fluid.

    Please provide a work space for the perimeter of the place in which Flowmeter is

    attached in consideration of the maintenance after attachment.

    Please attach after carrying out Flushing of the piping, in case Flowmeter is at

    tached after constructing new piping.

    When the possibility of a freeze is in winter, please perform heat insulation disposal to Flowmeter.

    Please open a valve gradually for an impact not to join Flowmeter at the time of a startup.

    Removal of Flowmeter, and the notes at the time of decompositionWhen removing Flowmeter attached in piping by the bolt nut or screw connection, the pressure in piping is

    perfect. Please remove after checking certainly that there is nothing and loosening a connection gradually.

    While passing fluid for piping, or when pressure has joined piping, they are a bolt nut or screw connection.

    Please do not remove. If it removes recklessly, there is a possibility that harm may join a human body.

    Please do not perform reconstruction of Flowmeter. Please contact our company, when you check Flowmeter.

    Attention of the installation direction liquid)In the case of level piping of a liquid Please attach so that

    D.P.transmitter becomes a level (transverse direction).

    In above or down, the case where exact measurement cannot

    be performed in response to the influence of air bubbles andgarbage arises.

    Attention of the installation direction steam)In the case of steamy level piping, please attach so that

    D.P.transmitter becomes right under or the bottom of

    slanting. When there is no space attached directly under

    piping, it can install also under slanting.

  • 8/12/2019 WPG-RDP-E02

    8/16

    RYUTAI KOGYO CO.,LTD. 816

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    Pressure Maximum flowrange Meter Size

    kPaG kg/h 25A 40A 50A 65A 80A 100A

    100 Minimum 25 40 80 120 200 300

    - Maximum 180 400 600 1000 1500 2500

    150 Minimum 40 60 100 150 250 500

    - Maximum 280 600 1000 1500 2200 3800

    200 Minimum 40 60 120 200 300 600

    - Maximum 300 650 1200 1500 2500 4100

    250 Minimum 50 80 120 200 300 600

    - Maximum 320 700 1200 1500 2500 4400

    300 Minimum 50 80 120 200 300 600

    - Maximum 350 750 1300 1800 2800 4800

    350 Minimum 50 80 120 200 300 600

    - Maximum 370 800 1300 1800 3000 5000

    400 Minimum 50 80 120 200 300 600

    - Maximum 380 900 1400 2000 3100 5300

    450 Minimum 50 80 120 200 300 600

    - Maximum 390 900 1400 2000 3200 5600

    500 Minimum 50 100 120 300 400 800

    - Maximum 400 1000 1500 2200 3500 5800

    550 Minimum 50 100 120 300 400 800

    - Maximum 420 1000 1500 2200 3600 6000

    600 Minimum 50 100 150 300 400 800

    - Maximum 420 1000 1600 2300 370 6300

    650 Minimum 50 100 150 300 400 800

    - Maximum 450 1100 1600 2300 3800 6500

    700 Minimum 50 100 150 300 500 1000

    - Maximum 460 1100 1700 2400 3900 6700

    750 Minimum 50 100 150 300 500 1000

    - Maximum 500 1100 1750 2400 4000 7000

    800 Minimum 60 100 150 300 500 1000

    - Maximum 500 1200 1800 2500 4200 7100

    850 Minimum 60 100 150 300 500 1000

    - Maximum 520 1200 1850 2500 4300 7200

    900 Minimum 60 100 150 300 500 1000

    - Maximum 520 1200 1900 2600 4400 7400

    950 Minimum 70 100 150 300 500 1000

    - Maximum 530 1200 1950 2600 4500 7600

    1000 Minimum 70 120 200 400 600 1000

    - Maximum 550 1300 2000 3000 4600 7800

    1050 Minimum 70 120 200 400 600 1000

    - Maximum 550 1300 2050 3000 4700 8000

    1100 Minimum 80 120 200 400 600 1000

    - Maximum 560 1300 2100 3100 4800 8100

    1150 Minimum 80 120 200 400 600 1000

    - Maximum 560 1300 2100 3100 4900 8300

    1200 Minimum 80 120 200 400 600 1000

    - Maximum 580 1400 2200 3200 5000 8400

    1250 Minimum 80 120 200 400 600 1000

    - Maximum 600 1400 2200 3200 5000 8600

    1300 Minimum 80 120 200 400 800 1200

    - Maximum 600 1500 2300 3300 5200 8800

    1350 Minimum 80 120 200 400 800 1200

    - Maximum 620 1500 2300 3300 5200 8900

    1400 Minimum 80 150 300 600 800 1200

    - Maximum 630 1500 2300 3500 5300 9100

    1450 Minimum 90 150 300 600 800 1200

    - Maximum 640 1500 2300 3500 5400 9200

    1500 Minimum 90 150 300 600 800 1200

    - Maximum 650 1600 2500 3600 5500 9300

    1550 Minimum 90 150 300 600 800 1200

    - Maximum 660 1600 2500 3600 5600 9500

    1600 Minimum 90 150 300 600 800 1200

    - Maximum 670 1600 2500 3800 5700 9600

    1650 Minimum 90 150 300 600 800 1200

    - Maximum 680 1600 2500 3800 5700 9800

    1700 Minimum 90 150 300 600 800 1200

    - Maximum 690 1800 2600 3800 5800 9900

    1750 Minimum 90 150 300 600 800 1200

    - Maximum 700 1800 2600 3800 5900 10000

    1800 Minimum 100 150 300 600 800 1200

    - Maximum 710 1800 2700 3900 6000 11000

    Flowrate range Saturated steam -1 RDP-100 RDP-505

    Please refer to a 9-page report.

  • 8/12/2019 WPG-RDP-E02

    9/16

    RYUTAI KOGYO CO.,LTD. 916

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    Pressure Maximum flowrange Meter Size

    kPaG kg/h 125A 150A 200A 250A 300A 350A

    100 Minimum 400 600 1000 2000 2500 3000

    - Maximum 4000 5200 9000 14000 22000 30000

    150 Minimum 700 1000 1500 3000 4000 5000

    - Maximum 5000 8200 15000 22000 27000 38000

    200 Minimum 700 1500 2000 3500 5000 7000

    - Maximum 7000 9000 16000 25000 35000 50000

    250 Minimum 700 1500 2000 3500 5000 7000

    - Maximum 7000 9500 17000 26000 38000 54000

    300 Minimum 700 1500 2000 3500 5000 7000

    - Maximum 8000 11000 18000 28000 40000 58000

    350 Minimum 700 1500 2000 3500 5000 7000

    - Maximum 8000 11000 19000 30000 43000 62000

    400 Minimum 700 1500 2500 3500 5000 7000

    - Maximum 8500 12000 21000 31000 45000 64000

    450 Minimum 900 1500 2500 3500 5000 7000

    - Maximum 9000 12000 21000 33000 48000 65500

    500 Minimum 900 2000 3000 4000 5000 7000

    - Maximum 10000 13000 23000 34000 50000 70000

    550 Minimum 900 2000 3000 4000 5000 7000

    - Maximum 10000 13000 24000 35000 51000 72500

    600 Minimum 1000 2000 3000 4000 5000 7000

    - Maximum 10500 14000 25000 37000 53000 75000

    650 Minimum 1000 2000 3000 4000 5000 7000

    - Maximum 10500 14000 25000 38000 55000 77500

    700 Minimum 1500 2000 3000 4000 7000 8000

    - Maximum 11000 15000 26000 39000 57000 80000

    750 Minimum 1500 2000 3000 4000 7000 8000

    - Maximum 11000 15000 27000 41000 57500 82500

    800 Minimum 1500 2000 3000 4000 7000 10000

    - Maximum 12000 16000 28000 42000 60000 85000

    850 Minimum 1500 2000 3000 4000 7000 10000

    - Maximum 12000 16000 28000 43000 61500 87000

    900 Minimum 1500 2000 3000 4000 7000 10000

    - Maximum 12000 16000 29000 44000 63000 89000

    950 Minimum 1500 2000 3000 4000 7000 10000

    - Maximum 12000 17000 29000 45000 64500 91000

    1000 Minimum 1500 2000 3000 5000 7000 10000

    - Maximum 13000 17000 30000 46000 66000 93000

    1050 Minimum 1500 2000 3000 5000 7000 10000- Maximum 13000 18000 31000 47000 67500 95000

    1100 Minimum 1500 2000 3000 5000 8000 10000

    - Maximum 13000 18000 32000 48000 69000 97000

    1150 Minimum 1500 2000 3000 6000 8000 10000

    - Maximum 13000 18000 32000 49000 70000 98500

    1200 Minimum 1500 2000 3000 5000 8000 10000

    - Maximum 14000 19000 33000 50000 72000 100000

    1250 Minimum 1500 2000 3000 6000 8000 10000

    - Maximum 14000 19000 33000 51000 73500 100000

    1300 Minimum 2000 2500 4000 7000 10000 12000

    - Maximum 14500 19000 34000 52000 75000 105000

    1350 Minimum 2000 2500 4000 7000 10000 12000

    - Maximum 14500 20000 34000 52000 76000 105000

    1400 Minimum 2000 2500 4000 7000 10000 12000

    - Maximu 15000 20000 35000 53000 77000 108000

    1450 Minimum 2000 2500 4000 7000 10000 12000- Maximum 15000 20000 35000 54000 78500 108000

    1500 Minimum 2000 2500 4000 7000 10000 12000

    - Maximum 15500 21000 36000 55000 80000 110000

    1550 Minimum 2000 2500 4000 7000 10000 12000

    - Maximum 15500 21000 36000 56000 81000 110000

    1600 Minimum 2000 2500 4000 7000 10000 12000

    - Maximum 16000 21000 37000 57000 82000 115000

    1650 Minimum 2000 2500 4000 7000 10000 12000

    - Maximum 16000 21000 37000 57000 83000 115000

    1700 Minimum 2000 2500 4000 7000 10000 12000

    - Maximum 16500 22000 38000 58000 84000 118000

    1750 Minimum 2000 2500 4000 7000 10000 12000

    - Maximum 16500 22000 38000 59000 85500 118000

    1800 Minimum 2000 2500 4000 7000 10000 12000

    - Maximum 17000 22000 39000 60000 87000 120000

    Flowrate range Saturated steam RDP-100 RDP-505

    The report 1. upper row serves as maximum of the minimum measuring range, and the lower berth serves as maximum of the maximum measuring range.

    Pressure is a gauge pressure. kPa (G) It expresses.

    Example 150A, saturated steam, pressure It becomes the 0-2000kg [/h ] minimum range, the maximum range 0 - 13000 kg/h at the time of 500kPa(G).

    Report 2. Pressure In the case of 100kPa(G) ..... Design Diff.press.25kPa, measurement range 1:7

    Pressure In the case of 150kPa(G) ..... Design Diff.press.35kPa, measurement range 1:8

    Pressure In the case of 200kPa(G) ..... Design Diff.press.50kPa, measurement range 1:10 or more

  • 8/12/2019 WPG-RDP-E02

    10/16

    RYUTAI KOGYO CO.,LTD. 1016

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    Pressure Maximum flowrange Meter Size

    kPaG m3/h(ntp) 25A 40A 50A 65A 80A 100A

    50 Minimum 20 30 40 60 80 120

    - Maximum 150 300 400 600 1000 2000

    100 Minimum 30 40 50 100 120 200

    - Maximum 200 420 700 1000 1600 2700

    150 Minimum 40 50 65 120 150 300

    - Maximum 300 700 1100 1600 2600 4300

    200 Minimum 50 60 80 150 200 400

    - Maximum 330 750 1200 2000 2800 4700

    250 Minimum 50 60 80 150 200 400

    - Maximum 350 800 1300 2000 3000 5100

    300 Minimum 50 80 100 150 300 500

    - Maximum 380 850 1400 2200 3200 5500

    350 Minimum 50 80 100 200 300 500

    - Maximum 400 910 1500 2300 3400 5800

    400 Minimum 50 80 120 200 300 500

    - Maximum 420 970 1600 2400 3600 6100

    450 Minimum 50 80 120 200 300 500

    - Maximum 450 1000 1650 2450 3800 6400

    500 Minimum 60 100 120 200 300 500

    - Maximum 470 1050 1700 2500 4000 6700

    550 Minimum 60 100 120 230 300 500

    - Maximum 480 1100 1800 2600 4200 7000

    600 Minimum 60 100 150 230 400 700

    - Maximum 520 1150 1850 2700 4300 7300

    650 Minimum 60 100 150 230 400 700

    - Maximum 530 1200 1900 2800 4500 7600

    700 Minimum 60 120 150 230 400 700

    - Maximum 540 1250 2000 2900 4600 7800

    750 Minimum 60 120 150 230 400 700

    - Maximum 550 1280 2050 3000 4800 8100

    800 Minimum 60 120 150 230 400 700

    - Maximum 580 1300 2100 3100 4900 8300

    850 Minimum 60 120 180 230 400 700

    - Maximum 590 1350 2200 3200 5000 8500

    900 Minimum 60 120 180 230 400 700

    - Maximum 600 1400 2200 3300 5200 8700

    950 Minimum 60 120 180 230 400 700

    - Maximum 620 1450 2300 3400 5300 9000

    1000 Minimum 80 150 180 250 400 700

    - Maximum 630 1500 2350 3500 5400 9200

    1050 Minimum 80 150 180 250 500 1000

    - Maximum 650 1550 2400 3600 5500 9400

    1100 Minimum 80 150 200 250 500 1000

    - Maximum 660 1600 2450 3700 5650 9600

    1150 Minimum 80 150 200 250 500 1000

    - Maximum 670 1650 2500 3800 5800 9800

    1200 Minimum 80 150 200 250 500 1000

    - Maximum 690 1650 2550 3900 5900 10000

    1250 Minimum 80 150 200 250 500 1000

    - Maximum 700 1650 2600 4000 6000 10100

    1300 Minimum 80 150 200 250 500 1000

    - Maximum 720 1700 2650 4100 6100 10300

    1350 Minimum 80 150 200 250 500 1000

    - Maximum 730 1700 2700 4200 6200 10500

    1400 Minimum 80 150 200 250 500 1000

    - Maximum 740 1700 2750 4300 6300 10700

    1450 Minimum 80 150 200 250 500 1000

    - Maximum 750 1700 2800 4400 6500 10900

    1500 Minimum 80 150 200 250 500 1000

    - Maximum 770 1750 2850 4500 6600 11000

    Flowrate range AIR RDP-100 RDP-505

    The report 1. upper row serves as maximum of the minimum measuring range, and the lower berth serves as maximum of the maximum measuring range.

    Pressure is a gauge pressure. kPa (G) It expresses.

    Example 100A, AIR , pressure It becomes the 0-500 m3/h(ntp) minimum range, the maximum range 0 - 6700 m3/h(ntp) at the time of 500kPa(G).

    Report 2. Pressure In the case of 100kPa(G) ..... Design Diff.press.25kPa, measurement range 1:7

    Pressure In the case of 150kPa(G) ..... Design Diff.press.35kPa, measurement range 1:8Pressure In the case of 200kPa(G) ..... Design Diff.press.50kPa, measurement range 1:10 or more

    Report 3. It is in 20 degrees C in AIR, and the operation state of 1atm (0kPaG). It expresses with flowrate (ntp) in the volume of 0 degree C and 1atm.

  • 8/12/2019 WPG-RDP-E02

    11/16

    RYUTAI KOGYO CO.,LTD. 1116

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    Pressure MaximumflowrangeMeter Size

    kPaG m3/h(ntp) 125A 150A 200A 250A 300A 350A

    50 Minimum 200 300 500 800 1200 1800

    - Maximum 2500 3000 5000 8000 12000 20000

    100 Minimum 300 500 800 1200 1800 2500

    - Maximum 3500 5800 10000 16000 28000 32000

    150 Minimum 500 600 1000 1500 2500 3000

    - Maximum 5000 9300 14000 21000 35000 40000200 Minimum 600 800 1300 2000 3000 3500

    - Maximum 6500 10200 18000 28000 39500 49000

    250 Minimum 600 800 1300 2000 3000 3500

    - Maximum 7000 11000 20000 30000 43000 53000

    300 Minimum 800 1000 1500 2300 3500 5000

    - Maximum 7500 12000 21000 32000 46000 57000

    350 Minimum 800 1000 1500 2300 3500 5000

    - Maximum 8000 12500 22000 34000 49000 60000

    400 Minimum 800 1000 1500 2300 3500 5000

    - Maximum 8500 13500 24000 36000 52000 64000

    450 Minimum 800 1000 1500 2300 3500 5000

    - Maximum 9000 14000 25000 38000 54000 67000

    500 Minimum 800 1000 1500 2300 3500 5000

    - Maximum 10000 15000 26000 40000 57000 70000

    550 Minimum 800 1000 1500 2300 3500 5000- Maximum 11000 15500 27000 41000 59000 73000

    600 Minimum 1000 1500 2000 2500 4000 7000

    - Maximum 12000 16000 28000 43000 61000 76000

    650 Minimum 1000 1500 2000 2500 4000 7000

    - Maximum 12500 16500 29000 45000 63500 79000

    700 Minimum 1000 1500 2000 2500 4000 7000

    - Maximum 13000 17000 30000 46000 65000 82000

    750 Minimum 1000 1500 2000 2500 4000 7000

    - Maximum 13500 17500 31000 47000 67500 84000

    800 Minimum 1000 1500 2000 2500 4000 7000

    - Maximum 14000 18000 31500 48500 70000 86000

    850 Minimum 1000 1500 2000 2500 4000 7000

    - Maximum 14500 18500 32500 49500 71000 89000

    900 Minimum 1000 1500 2000 2500 4000 7000

    - Maximum 15000 19000 33500 51000 73000 91000950 Minimum 1000 1500 2000 2500 4000 7000

    - Maximum 15000 19500 34000 53000 75000 93000

    1000 Minimum 1000 1500 2000 3000 5000 10000

    - Maximum 15500 20000 35000 54000 77000 96000

    1050 Minimum 1200 1700 2300 3500 7000 10000

    - Maximum 16000 20500 36000 55000 79000 98000

    1100 Minimum 1200 1700 2300 3500 7000 10000

    - Maximum 16500 21000 36500 56000 81000 100000

    1150 Minimu 1200 1700 2300 3500 7000 10000

    - Maximum 16500 21500 37000 58000 82000 102000

    1200 Minimum 1200 1700 2300 3500 7000 10000

    - Maximum 17000 22000 38000 58500 84000 104000

    1250 Minimum 1200 1700 2300 3500 7000 10000

    - Maximum 17000 22000 39000 59500 85000 106000

    1300 Minimum 1500 1700 2300 3500 7000 10000- Maximum 17500 22500 39500 60500 87000 108000

    1350 Minimum 1500 2000 2500 4000 8000 13000

    - Maximum 17500 23000 40000 61500 89000 110000

    1400 Minimum 1500 2000 2500 4000 8000 13000

    - Maximum 18000 23500 41000 63000 90000 112000

    1450 Minimum 1500 2000 2500 4000 8000 13000

    - Maximum 18000 24000 41500 64000 92000 114000

    1500 Minimum 1500 2000 2500 4000 8000 13000

    - Maximum 18500 24000 42000 65000 93000 116000

    Flowrate range AIR RDP-100 RDP-505

    Pressure MaximumflowrangeMeter Size

    kPaG m3/h 25A 40A 50A 65A 80A 100A 125A 150A 200A 250A 300A 350A100

    Minimum 1 1.5 2 2.5 3.5 8 9 15 20 35 50 60

    Maximum 6 13 22 35 50 90 135 195 330 520 750 900

    150Minimum 1 1.5 2 3 5 8 12 20 30 50 70 100

    Maximum 7 16 26 44 63 105 164 230 400 610 885 1090

    Minimum 1 1.5 2 3.5 5 8 12 20 30 50 70 100

    Maximum 8 19 31 53 75 130 196 275 478 736 1057 1314200 or more

    Flowrate range H2O WATER RDP-100 RDP-505

  • 8/12/2019 WPG-RDP-E02

    12/16

    RYUTAI KOGYO CO.,LTD. 1216

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    PRESSURE LOSS PDP-100 RDP-505

    "Standard design diff. press." although I design RDP-100/RDP-505 by arbitrary diff. press., in case there is

    no specification is. It is supposed ", with steam and a liquid, they are 50kPa", and ", at gas, they are 25kPa."

    8 pages - 11 pages Flowrange is calculated by "standard maximum diff.press."

    In appointed Maximum diff.press., it differs from flowrate range of a table.

    When you specify Maximum diff.press., be careful.Since the value of beta(iris diaphragm diameter ratio) d/D can be found with Maximu flowrange, pressure,

    and temperature, for details, please ask it to our company.

  • 8/12/2019 WPG-RDP-E02

    13/16

    RYUTAI KOGYO CO.,LTD. 1316

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    PRESSURE LOSS PDP-100 RDP-505

    "Standard design diff. press." although I design RDP-100/RDP-505 by arbitrary diff. press., in case there is

    no specification is. It is supposed ", with steam and a liquid, they are 50kPa", and ", at gas, they are 25kPa."

    8 pages - 11 pages Flowrange is calculated by "standard maximum diff.press."

    In appointed Maximum diff.press., it differs from flowrate range of a table.

    When you specify Maximum diff.press., be careful.Since the value of beta(iris diaphragm diameter ratio) d/D can be found with Maximu flowrange, pressure,

    and temperature, for details, please ask it to our company.

  • 8/12/2019 WPG-RDP-E02

    14/16

    RYUTAI KOGYO CO.,LTD. 1416

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    Compensation Calculation For PDP-100 RDP-505 Engineering data) In case of Gas measurement Volume flow rateThe pressure change from a design condition and temperature change produces indication error.

    Density change of the gas from a design condition produces a indication error.

    True flow rate = Indicate flow rate Compensation coefficient

    Q1 : True flow rate ( Volume flow rate m3/h(ntp) , l/h(ntp) , m3/min(ntp) , l/min(ntp) )

    Q0 : Indicate flow rate ( Volume flow rate m3/h(ntp) , l/h(ntp) , m3/min(ntp) , l/min(ntp) )

    : Actual Gas ( Density of an actual gas kg/m3(ntp) at 1atm , 0 )

    0 : Design Gas ( Density of an design gas kg/m3 (ntp) at 1atm , 0 )

    P1 : True pressure ( True operating pressure kPa(G) at gauge )

    P0 : Design pressure ( Design pressure kPa(G) at gauge )

    T1 : True temperature ( True operating temperature )

    T0 : Design temperature ( Design temperature )

    Compensation Calculation Example 1Original design condition of flowmeter

    Fluid name : AIR Design density : 1.293 kg/m3(ntp) Design pressure : 500 kPa(G) Design temperature : 20

    True process condition

    Fluid name : N2 Density : 1.250 kg/m3(ntp) True pressure : 400 kPa(G) True temperature : 25

    Indication of flowmeter : 2000 m3/h(ntp)

    True flow rate of N2 = 1841.6 m3/h(ntp)

  • 8/12/2019 WPG-RDP-E02

    15/16

    RYUTAI KOGYO CO.,LTD. 1516

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    Compensation Calculation For PDP-100 RDP-505 Engineering data) In case of STEAM measurement Mass flow rateThe pressure change from a design condition and temperature change produces indication error.

    Density change of the gas from a design condition produces a indication error.

    True flow rate = Indicate flow rate Compensation coefficient

    W1 : True flow rate ( Mass flow rate kg/h , kg/min , t/h )

    W0 : Indicate flow rate ( Mass flow rate kg/h , kg/min , t/h )

    : Actual steam ( Density of steam kg/m3 )

    0 : Design steam ( Density of steam kg/m3

    )

    Compensation Calculation Example 2Original design condition of flowmeter

    Fluid name : steam Design density : 3.173 kg/m3 Design pressure : 500 kPa(G)

    True process condition

    Fluid name : steam Density : 2.172 kg/m3 True pressure : 300 kPa(G)

    Indication of flowmeter : 6346 kg/h

    True flow rate of STEAM = 5250 kg/h

  • 8/12/2019 WPG-RDP-E02

    16/16

    WEB PRODUCTS GUIDE WPG-RDP-E02ORIFICE FLOWMETER RDP-100 RDP-505

    Head office Kyodo Bldg. (Shin-chuo)4-9 Nihonbashi-Honcho 1-Chome

    Chuo-ku Tokyo 103-0023 Japan

    el. 81--3242-0961

    ax. 81-3-3245-1980

    Osaka office Dohkita Bldg. 2-3-2 Dojima Kita-ku Osaka 530-0003

    Japan

    el. 81-6-6344-9458

    ax. 81-6-6344-5765

    Nagoya office Dai-Ni Kurokawa Terminal Heights 401 2-12-7 Tabata Kita-ku

    Nagoya-Shi 462-0843 Japan

    el. 81-52-910-6401

    ax. 81-52-910-6400 http://www.ryutai.co.jp/

    The product to guide is manufactured for the purpose of using it for the equipment of general industrial

    apparatus. It was not directly manufactured by the human life for the purpose of using it for the

    equipment used in a situation which is concerned.

    When there is a plan to use this product as those uses, please contact a marketing department office

    in advance.

    The product to guide is manufactured by severe quality control.

    When failure of parts etc. takes place, please construct the special consideration for building a safe systemabout employment of a system, maintenance, and management on the occasion of the use to a facility

    which is concerned with a human life, or the facility with which serious influence is expected.

    Since it is needed in a power source in use of this product, an electrical work, installation construction, etc.

    are required.

    Please use correctly for often reading the handling description of relation, before use of a

    product.

    Cautions when using a product

    Use limitation

    It was not manufactured in order to apply to the system of which the safety to affect the

    following human lives is required directly.

    The protection system aiming at safe maintenance of a human life.

    The medical C-system in connection with human life maintenance.

    Qualification

    About the following damage, our company shall be exempted from obligation.

    Damage produced by intentionally [ of a fire, an earthquake, the act by the third person, other accidents,

    and a user ] or negligence, misuse, and other use under unusual conditions.

    Damage produced since use of the product to guide is impossible (damage by loss of enterprise profits,

    and enterprise discontinuation).

    The inquiry about a product should inform of the following specification.

    A Model sign, an size, the flowrate range, a fluid name, density, viscosity, temperature, pressure,

    the quality of the material, the quantity.

    Written contents may be changed that there is no preliminary announcement because of product