Top Banner
The sole responsibility for the content of this presentation lies with the authors. It does not necessarily reflect the opinion of the European Union. Neither the EACI nor the European Commission are responsible for any use that may be made of the information contained therein. Contract N°: IEE/13/763/ SI2.674877 March 2014 - February 2017 NeZeR Design Competition ROMANIA [Andrei Toma + TEKPOD SRL, Technical University Gh. Asachi, Iasi] Sustainable Built Environment conference –SBE 16 Tallinn/Helsinki, 5-7 October 2016
10

VERDI - OpenSource 11kWh/m2 Modular envelope NeZeR

Feb 15, 2017

Download

Andrei Toma
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: VERDI - OpenSource 11kWh/m2 Modular envelope NeZeR

The sole responsibility for the content of this presentation lies with the authors. It does not necessarily reflect the opinion of the European Union. Neither the EACI nor the European Commission are responsible for any use that may be made of the information contained therein.

Contract N°: IEE/13/763/ SI2.674877March 2014 - February 2017

NeZeR Design CompetitionROMANIA

[Andrei Toma + TEKPOD SRL, Technical University Gh. Asachi, Iasi]

Sustainable Built Environment conference –SBE 16Tallinn/Helsinki, 5-7 October 2016

Page 2: VERDI - OpenSource 11kWh/m2 Modular envelope NeZeR

What challenge?

• Tower flats, Basement, 4 floors, terrace• 1968, Never refurbished• Self owned, between 20 landlords• Central heating: self owned• Energy consumption, space heating

212.9 kWh/sqm• Energy consumption, domestic hot

water 66.33 kWh/sqm• Energy consumption, other 10.99

kWh/sqm

Page 3: VERDI - OpenSource 11kWh/m2 Modular envelope NeZeR

What challenge?

• To gain energy efficiency performance through embeded renewable energy soruces

• To refurbish the central heating distribution system on a horizontal level

• To reduce the primary heating energy consuption to less than 90 kWh/sqm

• The building is a standard cube with inset balconies

• The building is in climate zone II• Constant shaddows in lower floors

Page 4: VERDI - OpenSource 11kWh/m2 Modular envelope NeZeR

Renovation concept

• Walls 300mm insulation U-Value: 0.094W/m2K, roof 460mm U-Value 0.095W/m2K, ground floor 520mm U-Value 0.131W/m2k

• HVAC : 2x Venco VRH• Solar PV + Solar Thermic panels installed on 284m2 output of 57.6 kWh/m2

Page 5: VERDI - OpenSource 11kWh/m2 Modular envelope NeZeR

Proposed technical solutionsOriginal building After NZEBR

WallsU=1.66 W/m2K U=0.094 W/m2K

Basement U=2.5 W/m2K U=0.131 W/m2K

RoofU=0.877 U=0.095 W/m2K

Windows Unknown U=0.80 W/m2K

HVAC290.22 kWh/m2 82.5 kWh/m2

RESNone 57.6 kWh/m2

Page 6: VERDI - OpenSource 11kWh/m2 Modular envelope NeZeR

Environmental aspects – Materials selected

•Glulam

•Mineral wool

•BASF NEOPOR

Page 7: VERDI - OpenSource 11kWh/m2 Modular envelope NeZeR

User aspects• Space extension: balcony, bigger

living room, lift• Self controlled HVAC, based on user

behaviour through smart appliances• Failsafe systems to ensure security of

thermal appliances for overheating and underheating

• 3 Months renovation process with little disruption over residents

• Residents to be informed through a portal with the current stages of design, being updated daily which include expenditure, current status on a timeline and next in line for processes.

Page 8: VERDI - OpenSource 11kWh/m2 Modular envelope NeZeR
Page 9: VERDI - OpenSource 11kWh/m2 Modular envelope NeZeR

Market appeal

• The building stock of Romania, with a similar shape is around 157,000

• Technologies used are produced in a mass market environment• A prefab solution, to ease installation and disruption• Risk Free• B2B prefab model receivesdiscounts on bulk sales• Investment of €542,953 • 30 years Life cycle cost €810,740• Investment €50 / person / month• Sustainable derivatives options for investors

Page 10: VERDI - OpenSource 11kWh/m2 Modular envelope NeZeR

Strengths and weaknesses

Strong points of the renovation concept:•Lightweight envelope, ease of transportation•Performant materials, high energy savings•Compact, expandable easy to multiply

Weaknesses / aspects to be improved:•High cost for low income families•Lack of renovation funding and political instability in Romania•Lack of skilled labourfocer due to recent tallent immigration to neibouring countries