Alyssa Quarforth Program Analyst US EPA ENERGY STAR March 4, 2008 US EPA ENERGY STAR: Benchmarking Energy Use in Commercial Buildings
30

US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Mar 14, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Alyssa QuarforthProgram Analyst

US EPA ENERGY STARMarch 4, 2008

US EPA ENERGY STAR:Benchmarking Energy Use inCommercial Buildings

Page 2: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Making Headlines….

St Paul Public Schools, second largest school district inMinnesota, avoided energy costs amounting to over $1million in the last 4 yrs.

Transwestern Commercial Services increased theirasset value by $750 million from 2002 to 2004 throughenergy conservation.

Food Lion, committed to a company-wide strategy forenergy efficiency, has seen savings amounting tonearly $105 million.

Marriott International has achieved $4.5 million inannual savings through a strategic EnergyConservation Program.

Page 3: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

The Value of Energy Efficiency inCommercial Buildings

In 2006, American consumers and businesses, with the help ofENERGY STAR:

Prevented the release of greenhouse gas emissionsequivalent to those from 25 million automobiles.Saved more than $14 billion on energy bills.

The buildings in which we work, shop, play, and educate ourchildren use $200 billion of electricity and natural gas each year.

According to the U.S. Green Building Council, GHG emissionsfrom commercial buildings are projected to grow faster than anyother sector over the next 25 years – about 1.8 percent per year.

Commercial buildings and industrial facilities generate 45% ofour national emissions of greenhouse gases.

30% of energy consumed in commercial buildings is usedunnecessarily or inefficiently.

Page 4: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Energy as a Percentage of Total OfficeBuilding Operating Expenses

Janitorial

18%

Repairs &

maintenance

23%

Roads, grounds, &

security

12%

Administrative

19%

Energy 28%

Data based on 2007 BOMA Experience Exchange Report(Average of Urban & Suburban Non-Government Buildings)

Page 5: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

ENERGY STAR for CommercialBuildings

U.S. Environmental Protection Agency energymanagement program.

Provides proven solutions to help public andprivate sector building owners and managersreduce their energy consumption.

Works in markets with a focus on:

Public sector (government, K-12, higher ed)

Commercial property (offices, retail, hotels)

Healthcare

Small business and congregations

Page 6: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

ENERGY STAR for CommercialBuildings

ENERGY STAR buildings' utility bills are over 50 cents persquare foot less than average buildings’.

On average, ENERGY STAR buildings use 35 percent lessenergy than average buildings.

Nearly 30 percent of Fortune 500 companies are ENERGYSTAR partners.

ENERGY STAR office properties gross higher rents andhigher occupancy rates than their non-ENERGY STARcounterparts.

Over 60,000 buildings, representing about 8 billion squarefeet of space, have measured their energy performance withENERGY STAR.

Page 7: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

ENERGY STAR for CommercialBuildings

Offer a variety of free technical resources:

Tools to benchmark and track energy performance in buildings

Energy Management Guidelines

Assistance for architects on designing energy efficient buildings

Case studies and best practices from leaders

Calculators to track returns on energy efficiency investments

Training

Materials to communicate with citizens, employees, stakeholders,and the media about energy efficiency efforts.

Opportunities for national recognition:

ENERGY STAR Label

ENERGY STAR Leader

ENERGY STAR Partner of the Year

Page 8: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Successful Benchmarking Can Help to:

Plan and prioritize upgrade efforts and retrofits

Make energy costs visible

Identify best (and worst) building management practices within abuilding or across a portfolio of buildings

Assess performance relative to peers in the same sector oracross other sectors

Identify areas of improvement and make informed managementand investment decisions

Communicate good results to the public

Benchmarking has helped Food Lion to reduce its

utility cost per store per week by 5.5%

Page 9: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Myth #1: Age Matters

My building is new, so I knowit’s energy efficient.

Page 10: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

1

Worst PerformersBest Performers

Num

ber

of B

uild

ings

25507590

Top performingbuildings use 3 to 4times less energyper ft2 than theworst performers.

Newer buildings areequally representedacross all quartiles.

Based on a sampleof 4,000 buildingsnationwide.

10

39% of

buildings

with a rating

of 75 or

better are

less than 25

years old

42% of

buildings

with a rating

between 25

and 74 are

less than 25

years old

35% of

buildings

with a rating

between 0

and 24 are

less than 25

years old

121.129.9 165.786.0 339.4

EPA Performance Rating&

Energy Intensity( /f 2 )

New Doesn’t Always Equal Efficient

Page 11: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Myth #2: Technology Matters

I installed energy efficienttechnologies, so I know mybuilding is energy efficient.

Page 12: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Technology Doesn’t Always EqualPerformance

67%

56%

73%

45%

21%

36%

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

VA

V

EM

S

Eco

nom

izer

VS

Ds

Mot

ion

Sen

sors

Ene

rgy

Aud

it

Technology/Strategy

Perc

en

t

ENERGY STAR1999 - 200161.4 kBtu/ft2/yr

CBECS Average

106.7 kBtu/ft2/yr

CBECS

Top 25%

51.4 kBtu/ft2/yr

CBECS

Bottom 25%

226.3 kBtu/ft2/yr

Page 13: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

If you’re still not convincedthat benchmarking energy

use is a good idea…

Page 14: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Fort Wayne Fire Stations 20 Similar Buildings – Different Energy Use

Page 15: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Benchmarking with Portfolio Manager

Go to:

www.energystar.gov1.

2. Click on:

Buildings and Plants

Page 16: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Benchmarking with Portfolio Manager

Click on:

“Portfolio

Manager”

3.

Page 17: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Benchmarking with Portfolio Manager

Page 18: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Inside Portfolio Manager

Page 19: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Benchmarking with Portfolio Manager

Track multiple energy and water meters for each facility

Customize meter names and key information

Benchmark your facilities relative to past performance

View percent improvement in weather-normalized source energy

Monitor energy and water costs

Share your building data with others inside or outside of yourorganization

Enter operating characteristics, tailored to each space usecategory within your building.

Rate energy performance on a scale of 1-100 relative to similarbuildings nation wide

Page 20: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Portfolio Manager Statement of EnergyPerformance

Page 21: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Fuel Efficiency

MPG

Is 18 MPG high or low foran automobile?

Energy

Performance

EPA

Benchmarking

Is 80 kBtu/SF/YR high or low

for a building?

Is Your Building Performing Well?

Page 22: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

EPA’s Energy Performance RatingSystem for Commercial Buildings

Housed within Portfolio Manager

Based on actual billed energy data

Creates a whole building indicatorCapture the interactions of building systems not individual equipmentefficiencyTrack energy use accounting for weather and operational changes overtime

Gives a peer group comparisonCompare a building’s energy performance to its national peer groupTrack how changes at a building level alter the building’s standingrelative to its peer group

Uses a simple 1-100 “score” where 50 is an averagebuilding

Normalizes for factors such as weather, occupancy,operating hours, and other building-specificcharacteristics

Page 23: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

EPA Rating – Technical Foundation

Analyze national survey data

Energy Information Administration’s Commercial Building EnergyConsumption Survey (CBECS)

Develop regression models to predict energy use for specific buildingtypes based on operations

Create scoring lookup table

Ratings are based on the distribution of energy use for a given building type

Ratings are expressed on a 1-to-100 scale such that one point representsone percentile of buildingsA rating of 50 indicates that your building is better than 50% of buildings inthe population

Buildings that earn a 75 or higher can earn the ENERGY STAR label

Page 24: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Offices K-12 Schools

HotelsSupermarkets

Hospitals

Medical Office

Buildings

EPA’s Energy Performance RatingSystem – Available Space Types

Page 25: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

EPA’s Energy Performance RatingSystem – Available Space Types

Retail Stores

Wastewater

Treatment Plants

Warehouses Courthouses

Residence Halls Financial Centers

Page 26: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Improving Management Strategies:1900 K Street, Washington DC

New Construction (1996) with energyefficiency in mind but oversized equipmentEPA Rating

In 1999 32In 2006 78

Harnessed building automation systems toimprove efficiency

VFDs on chillers to match measure demandImproved operating standards – static pressure setpointsContinuous tracking of energy useImprovements to lighting systems

Savings reflect synergy between buildingtechnology and energy management practices

Page 27: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Whole Building Strategy:St. Francis Hospital, Missouri

150,000 sq. ft hospital- Maryville, Missouri

Initial rating 51

Methodological review

Commissioning, lighting and ENERGY STAR procurementpolicy

Used $ saved from right-sizing water pump to buy new boilers

Used $ saved from new boilers to fund new DDC controls

In one year:

Score: 91

Gas bill cut in half

Electricity reduced 17%

“Benefits to patient comfort….

savings put into patient services”

Page 28: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

First Step to Green:Citigroup

Portfolio = 90 million sq. ft.

Comprehensive tracking of + 13,000 properties

Set ghg reduction goal: 10% by 2011

Use EPA energy performance rating

Enhance internal tracking

Identify facilities to improve

First step in plans for LEED-EB

“We believe that by participating in ENERGY STAR and LEEDcertification programs, we can better prioritize our emission-reduction activities in the next 5 years and have a bettermethod of measuring our progress”

Page 29: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Summary

ENERGY STAR provides proven resources to help buildingowners and managers reduce energy consumption

Portfolio Manager is a premier tool to help you benchmark(You cannot manage what you do not measure!)

The ENERGY STAR Rating presents a useful benchmark ofwhole building energy performance

Easy to communicate 1-to-100 peer group comparison

The ENERGY STAR Rating has been extremely valuable forENERGY STAR Partners

Benchmark energy performancePrioritize investmentsImprove energy efficiencyTrack cost and emissions savings

Get started today at www.energystar.gov !

Page 30: US EPA ENERGY STAR: Benchmarking Energy Use in Commercial ...

Questions?Questions?

www.energystar.gov