Upflow/ Horizontal Downflow/HorizontalCondensing, Direct Vent Gas-Fired Furnace
NATURAL GAS MODELSCentral Heating furnace designs are certified to ANSI Z21.47 / CSA 2.3 for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating condi-tions using American National Stan-dards Institute standards.
SAFE OPERATIONThe Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety.
QUICK HEATINGDurable, cycle tested, heavy gauge alu-minized steel heat exchanger quickly transfers heat to provide warm condi-tioned air to the structure. Low energy power vent blower, to increase effi-ciency and provide a positive discharge of gas fumes to the outside.
BURNERSMultiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners.
INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connec-tion points for E.A.C./humidifier.
AIR DELIVERYThe four speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.
STYLINGHeavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchang-er section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient opera-tion due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision.
FEATURES AND GENERAL OPERATIONThe XR 95 High Efficiency Gas Furnac-es employ a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access.
a. Low energy power venter
b. Vent proving pressure switch.
Features and Benefits
XR 95 Standard Equipment• Powersupply115/1/60
• Convertibletohorizontal
• Type 29-4C™ stainless steel second-ary heat exchanger
• Innerblowerdoors
• Directdrive,4-speedmotors
• SiliconNitrideigniterwithadaptiveheat up
• Accessoryhook-upcapability– Hum and EAC
• Quietinduceddraftblower
• Blowerdoorsafetyswitch
• Dualsolenoidcombinationgasvalve®ulator
• PVCventing–1or2pipeventoption
• Left/rightgasconnection
• Selectablecoolingfanoffdelayelimi-nates need for BAY24X045 time delay relay
• Singlewiretwinning
• Integratedsolidstatecontrolwithself-diagnostics
• 24voltfuse
• Manualresetburnerboxlimit
• Optional extended warranties
22-1836-09 3
Contents
General Features 2Features and Benefits 2
XR 95 Standard Equipment 2XR 95 Optional Equipment 4
General Data 5TUH1B040A9241A 5TUH1B060A9361A 5TUH1B080A9421B 5TUH1C080A9601A 6TUH1C100A9481A 6TUH1D100A9601A 6TUH1D120A9601A 6TDH1B040A9241A 7TDH1B065A9421A 7TDH1C085A9481A 7TDH1D110A9601A 7
Performance Data 8Electrical Data 10Field Wiring 14Twinning Field Wiring 15Dimensions 16
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
General Data
TUH1B040A9241A
Upflow / Horizontal
40,00038,00095.0
30 - 60
DIRECT9 x 7
14
See Fan Performance Table1/5
1075115/1/60
CentrifugalDirect - 1
1/55 - 3000115/1/60
1.0
NoHigh Velocity
1 - 17x25 - 1in.
2 Round
Aluminized Steel - Type I
20
2 — 452 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot2
115/1/605.215
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
139 / 129
TUH1B060A9361A
Upflow / Horizontal
60,00057,00095.0
30 - 60
DIRECT10 x 7
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/55 - 3450115/1/60
1.75
NoHigh Velocity
1 - 17x25 - 1in.
2 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot3
115/1/609.215
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
150 / 140
Notes1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
Notes1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".
General Data
TUH1C080A9601A
Upflow / Horizontal
80,00076,00095.0
30 - 60
DIRECT11 x 10
14
See Fan Performance Table3/4
1100115/1/60
CentrifugalDirect - 1
1/20 - 3450115/1/60
0.71
NoHigh Velocity
1 - 20x25 - 1in.
3 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot4
115/1/6013.520
1/2
H x W x D41-3/4 x 23 x 30-1/2
171 / 160
22-1836-09 7
Notes1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".