Upflow/ HorizontalDownflow/HorizontalCondensing, Direct VentGas-Fired Furnace
NATURAL GAS MODELSCentral Heating furnace designs arecertified to ANSI Z21.47 / CSA 2.3 forboth natural and L.P. gas. Limit settingand rating data were established andapproved under standard rating condi-tions using American National StandardsInstitute standards.
SAFE OPERATIONThe Integrated System Control has solidstate devices, which continuously monitorfor presence of flame, when the system isin the heating mode of operation. Dualsolenoid combination gas valve andregulator provide extra safety.
QUICK HEATINGDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure. Lowenergy power vent blower, to increaseefficiency and provide a positive dis-charge of gas fumes to the outside.
BURNERSMultiport Inshot burners will give years ofquiet and efficient service. All modelscan be converted to L.P. gas withoutchanging burners.
INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnacelimit sensors, blowers, gas valve, flamecontrol and includes self diagnostics forease of service. Also contains connec-tion points for E.A.C./humidifier.
AIR DELIVERYThe four speed, direct drive blowermotor, has sufficient airflow for mostheating and cooling requirements, willswitch from heating to cooling speeds ondemand from room thermostat. Theblower door safety switch will prevent orterminate furnace operation when theblower door is removed.
STYLINGHeavy gauge steel and “wrap-around”cabinet construction is used in thecabinet with baked-on enamel finish forstrength and beauty. The heat ex-changer section of the cabinet is com-pletely lined with foil faced fiberglassinsulation. This results in quiet andefficient operation due to the excellentacoustical and insulating qualities offiberglass. Built-in bottom pan andalternate bottom, left or right side returnair connection provision.
FEATURES ANDGENERAL OPERATIONThe XR 95 High Efficiency Gas Furnacesemploy a Silicon Nitride Hot SurfaceIgnition system, which eliminates thewaste of a constant burning pilot. Theintegrated system control lights the mainburners upon a demand for heat from theroom thermostat. Complete front serviceaccess.
a. Low energy power venter
b. Vent proving pressure switch.
Featuresand Benefits
XR 95 Standard Equipment• Power supply 115/1/60
• Convertible to horizontal
• Type 29-4C™ stainless steel second-ary heat exchanger
• Inner blower doors
• Direct drive, 4-speed motors
• Silicon Nitride igniter with adaptiveheat up
• Accessory hook-up capability –Hum and EAC
• Quiet induced draft blower
• Blower door safety switch
• Dual solenoid combination gas valve ®ulator
• PVC venting – 1 or 2 pipe vent option
• Left/right gas connection
• Selectable cooling fan off delayeliminates need for BAY24X045 timedelay relay
• Single wire twinning
• Integrated solid state control with self-diagnostics
• 24 volt fuse
• Manual reset burner box limit
• Optional extended warranties
22-1836-07 3
Contents
General Features 2
Features and Benefits 2XR 95 Standard Equipment 2XR 95 Optional Equipment 4
General Data 5TUH1B040A9241A 5TUH1B060A9361A 5TUH1B080A9421A 5TUH1C080A9601A 6TUH1C100A9481A 6TUH1D100A9601A 6TUH1D120A9601A 6TDH1B040A9241A 7TDH1B065A9421A 7TDH1C085A9481A 7TDH1D110A9601A 7
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
GeneralData
TUH1B040A9241A
Upflow / Horizontal
40,00038,00095.0
30 - 60
DIRECT9 x 7
14
See Fan Performance Table1/5
1075115/1/60
CentrifugalDirect - 1
1/55 - 3000115/1/60
1.0
NoHigh Velocity
1 - 17x25 - 1in.
2 Round
Aluminized Steel - Type I
20
2 — 452 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot2
115/1/605.215
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
139 / 129
TUH1B060A9361A
Upflow / Horizontal
60,00057,000
95.030 - 60
DIRECT10 x 7
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/55 - 3450115/1/60
1.75
NoHigh Velocity
1 - 17x25 - 1in.
2 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot3
115/1/609.215
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
150 / 140
Notes1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feetabove sea level.
3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
Notes1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500feet above sea level.
3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".
GeneralData
TUH1C080A9601A
Upflow / Horizontal
80,00076,000
95.030 - 60
DIRECT11 x 10
14
See Fan Performance Table3/4
1100115/1/60
CentrifugalDirect - 1
1/20 - 3450115/1/60
0.71
NoHigh Velocity
1 - 20x25 - 1in.
3 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot4
115/1/6013.520
1/2
H x W x D41-3/4 x 23 x 30-1/2
171 / 160
22-1836-07 7
Notes1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500feet above sea level.
3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".