Top Banner
Unreinforced Masonry Buildings Paul Lepore
25

Unreinforced Masonry Buildings Paul Lepore

Apr 19, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Unreinforced Masonry Buildings Paul Lepore

Unreinforced Masonry BuildingsPaul Lepore

Page 2: Unreinforced Masonry Buildings Paul Lepore

How to Identify Unreinforced Masonry buildings (URM)

• Arch over window• Deep, recessed windows• High parapet walls• Tie plates• Lintel over window• King row every 5 – 7 bricks

Page 3: Unreinforced Masonry Buildings Paul Lepore

Hazards of URM buildings

• No rebar• No lime in mortar• Fire cut beams

Page 4: Unreinforced Masonry Buildings Paul Lepore

Arch over window

Page 5: Unreinforced Masonry Buildings Paul Lepore

Arch over window

Deep reset windows

Page 6: Unreinforced Masonry Buildings Paul Lepore

King RowEvery 5 – 7 rows

Bricks laid on end ←

Page 7: Unreinforced Masonry Buildings Paul Lepore

Lintel

Horizontal support over a window or door made of steel.

• Fails at 800 – 1200 dgrees• Only horizontal support for bricks

Page 8: Unreinforced Masonry Buildings Paul Lepore

Lintel ↑↑

Page 9: Unreinforced Masonry Buildings Paul Lepore

Lintel ↑↑

Page 10: Unreinforced Masonry Buildings Paul Lepore

Lintel ↑↑

Page 11: Unreinforced Masonry Buildings Paul Lepore

Tie plates

• Tie horizontal floor or ceiling joists to the wall.

• Indicated by “plates” on side of building• Plates often covered during building

retrofit

Page 12: Unreinforced Masonry Buildings Paul Lepore

Tie Plate

This is what you see↓

Attached to rafter or floor joist

Captain R. Grego

Page 13: Unreinforced Masonry Buildings Paul Lepore

Captain R. Grego

Page 14: Unreinforced Masonry Buildings Paul Lepore

Captain R. Grego

Page 15: Unreinforced Masonry Buildings Paul Lepore

Tie Plates↓ ↓ ↓

Page 16: Unreinforced Masonry Buildings Paul Lepore
Page 17: Unreinforced Masonry Buildings Paul Lepore
Page 18: Unreinforced Masonry Buildings Paul Lepore

No lime in mortar

↓↓

Page 19: Unreinforced Masonry Buildings Paul Lepore

URM Concrete Bondbeam

Captain R. Grego

Page 20: Unreinforced Masonry Buildings Paul Lepore

URM Wall Thickness

Window Sill

Seismic Upgrade

3 Wythe’s Thick approx 13”

Re-inforced Concrete Bondbeam

Captain R. Grego

Page 21: Unreinforced Masonry Buildings Paul Lepore
Page 22: Unreinforced Masonry Buildings Paul Lepore
Page 23: Unreinforced Masonry Buildings Paul Lepore

URM Building?URM Building?

URM?

Page 24: Unreinforced Masonry Buildings Paul Lepore

Imitation URMNo tie platesNo King rowToo new in appearanceSpace above window before arch ****

******

Page 25: Unreinforced Masonry Buildings Paul Lepore

Imitation URM•No King row•Too new