K1 B1008 www.turck.us · 1-800-544-7769 · Fax: (763) 553-0708 · TURCK Inc. Minneapolis, MN 55441 TURCK Industrial Connectivity Products Rugged, durable and reliable, TURCK connectivity products connect the sensing devices to higher-level control components – and much more! With splitters, branches and tees, you can get a cordset exactly where you want it. TURCK’s connectivity products meet all applicable standards for any application. Cordsets • Sizes from the sub-miniature M5 to the 35 Amp M40 power connector • 2 through 28-pin connectors • Cable suitable for any environment • Custom cable designs Splitters • Increase connection possibilities • 2, 3 and 4 branch options Rugged, Sealed Junction Boxes • Consolidate wiring • 4, 6 or 8 ports, with or without LEDs for NPN or PNP sensors CONNECT IT! Can’t find what you’re looking for? Unsure which products will work best for your application? TURCK’s experienced engineers will work with you to provide an application specific solution – even if it means designing a new product! TURCK can customize many of our products to your needs, including: • Custom connectorized cables or sensors • Tailored solutions for unconventional product specifications • Private wrap and custom printed labels Challenge us with something new! Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Rugged, durable and reliable, TURCK connectivity products connect the sensing devices tohigher-level control components – and much more! With splitters, branches and tees, youcan get a cordset exactly where you want it. TURCK’s connectivity products meet allapplicable standards for any application.
Cordsets
• Sizes from the sub-miniature M5 to the 35 Amp M40power connector
• 2 through 28-pin connectors
• Cable suitable for any environment
• Custom cable designs
Splitters
• Increase connection possibilities
• 2, 3 and 4 branch options
Rugged, Sealed
Junction Boxes
• Consolidate wiring
• 4, 6 or 8 ports, with or withoutLEDs for NPN or PNP sensors
CONNECT IT!
Can’t find what you’re looking for? Unsure which products willwork best for your application? TURCK’s experienced engineerswill work with you to provide an application specific solution –even if it means designing a new product! TURCK can customizemany of our products to your needs, including:
• Custom connectorized cables or sensors
• Tailored solutions for unconventional product specifications
• Private wrap and custom printed labels
Challenge us with something new!
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Housing Style Part Number Cable Application Pinout
P-RKGV 4.43T-1699-* ITC-ER/PLTC PVC Grey
3x22 AWG
105°C5.7 mm OD
Cable #RF51699-*M
3-wire DC Sensor †
1. BN
2. N/C
3. BU
4. BK
P-RKG 4.41T-1700-* ITC-ER/PLTC PVC Grey
4x22 AWG, 1 Triad with GND
105°C
6.2 mm OD
Cable #RF51700-*M
4-wire DC Sensor †
1. BN
2. WH
3. BU
4. BK
P-RKG 4.41T-1698-* ITC-ER/PLTC PVC Grey
4x22 AWG
Foil/Drain (22)
105°C6.2 mm OD
Cable #RF51698-*M
4-wire discrete or analog
control circuits in Class I,
Division 2 hazardous
locations** or unclassified
locations.
1. BN
2. WH
3. BU
4. BK
* Length in meters. Standard cable lengths are 2, 4, 5, 6, 8 and 10 meters. Consult factory for other lengths.Standard coupling nut material is nickel plated brass “P-RKG ..”; “P-RKGV ..” indicates stainless steel.
** Use with lokfast eurofast guards (part number: LOCK-EURO-G) in Class I, Division 2 applications.Note: See TURCK Control Drawing QCF-00147 (FM) or Ni-2.404 (CSA) at www.turck.com/fmcd for guidance on installation in hazardous locations.
† FM approval applies when used with sensor part number ending in "/S1751".
4-Wire M12 eurofast ® Drop Cordsets, Additional Analog or Discrete Control Circuits
• Straight Female Connectors
• IEC IP 68 Protection
• 250 V, 4 A (Use as ITC Limited to 150
V, 3 A for 22 AWG Conductors)
P-RKG ..
Part Number Application
LOCK-EURO-GNylon locking guard for straight eurofast G-body connectors
(RKG, RKGV, RSG and RSGV) in Class I, Division 2 installations*.
Switch part number must end in "/S1751"
LOCK-EURO-G (10/BAG)
LOCK-EURO-FWNylon locking guard for straight eurofast field wireable connectors
(B81.., BS81.. and BM81..) in Class I, Division 2 installations*
LOCK-EURO-FW (10/BAG)
eurofast ® lokfast Guards
lokfast Open
lokfast Closed
* See TURCK Control Drawing QCF-00147 (FM) or Ni-2.404 (CSA) at www.turck.com/fmcd/ for guidance on installation in hazardous locations.
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
2-Wire M12 eurofast ® Cordsets, Standard Plug Body
Housing Style Part Number Cable Features Pinout
RK 4.2T-* AWM PVC Grey
2x20 AWG
105°C
5.1 mm OD
Cable #RF50529-*M†
flexlife ®
1. N/C
2. N/C
3. BN
4. BURK 4.2T-*/S90 ITC/PLTC TPU Grey
2x20 AWG
105°C
5.1 mm OD
Cable #RF50772-*M†
Cut/Abrasion
Immune
RK 4.2T-*/S674 AWM PVC Grey
2x20 AWG
5.1 mm OD
Cable #RF50529-*M†
flexlife
1. BN
2. N/C
3. N/C
4. BU
RK 4.2T-*/S748 AWM PVC Yellow
2x22 AWG
105°C
5.1 mm OD
Cable #RF50650-*M†
flexlife
1. WH
2. N/C
3. N/C
4. BK
RK 4.21T-*/S1511 AWM PVC Grey
2x20 AWM PVC
105°C
5.1 mm OD
Cable #RF50529-*M†
1. BN
2. BU
3. N/C
4. N/C
RK 4.21T-* AWM PVC NAMUR Blue
2x20 AWG
105°C
5.1 mm OD
Cable #RF20003-*M†
RK 4.21T-*/S90 AWM TPU NAMUR Blue
2x20 AWG
90°C
5.1 mm OD
Cable #RF50657-*M†
Cut/Abrasion
Immune
RK 4.22T-*
AWM PVC Grey
2x20 AWG
105°C
5.1 mm OD
Cable #RF50529-*M†
flexlife
1. BN
2. N/C
3. BU
4. N/C
RK 4.23T-* 1. BN
2. N/C
3. N/C
4. BU
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters. Consult factory for other lengths.** Standard coupling nut material is nickel plated brass "RK .."; "RKK .." indicates nylon and "RKV .." indicates stainless steel.† See Section N of Connectivity Catalog for reelfast ® cable information.
RKK ..**
RK ..**
RKV ..**
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters. Consult factory for other lengths.** Standard coupling nut material is nickel plated brass "RK .."; "RKK .." indicates nylon and "RKV .." indicates stainless steel.† See Section N of Connectivity Catalog for reelfast ® cable information.
RK ..**
RKK ..**
RKV ..**
3-Wire M12 eurofast ® Cordsets, Standard Plug Body
• Straight Female Connector
• NEMA 1, 3, 4, 6P
• IEC IP 68 Protection
• 250 V, 4 A
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters. Consult factory for other lengths.** Standard coupling nut material is nickel plated brass "RK .."; "RKK .." indicates nylon and "RKV .." indicates stainless steel.† See Section N of Connectivity Catalog for reelfast ® cable information.
RK ..**
RKK ..**
RKV ..**
4-Wire M12 eurofast ® Cordsets, Standard Plug Body
• Straight Female Connector
• NEMA 1, 3, 4, 6P
• IEC IP 68 Protection
• 250 V, 4 A
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters. Consult factory for other lengths.** Standard coupling nut material is nickel plated brass "RK .."; "RKK .." indicates nylon and "RKV .." indicates stainless steel.† See Section N of Connectivity Catalog for reelfast ® cable information.
RK ..**
RKK ..**
RKV ..**
5-Wire M12 eurofast ® Cordsets, Standard Plug Body
• Straight Female Connector
• NEMA 1, 3, 4, 6P
• IEC IP 68 Protection
• 250 V, 4 A
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
3 and 4-Wire M12 eurofast ® Cordsets, "G" Style Large Plug Body
Housing Style Part Number Cable Features Pinout
RKG 4T-* ITC/PLTC PVC Yellow
3x18 AWG
105°C
7.2 mm OD
Cable #RF50513-*M†
flexlife ®
1. BN
2. N/C
3. BU
4. BK
RKG 4T-*/S600 SJOOW
CPE Yellow
3x18 AWG
105°C
8.0 mm OD
Cable #RF50654-*M†
Weld Flash Immune,
Flame Resistance
RKG 4.4T-* AWM PVC Yellow
4x18 AWG
105°C
7.2 mm OD
Cable #RF50579-*M†
flexlife
1. BN
2. WH
3. BU
4. BK
RKG 4.4T-*/S90 ITC/PLTC TPU Yellow
4x18 AWG
105°C
7.2 mm OD
Cable #RF50544-*M†
Cut/Abrasion
Immune
RKG 4.4T-*/S101/S849 AWM TPE Grey
4x22 AWG
105°C
5.7 mm OD
Cable #RF50941-*M†
flexlife-20,
High Flex - Over 20
Million Cycles
RKG 4.4T-*/S101 AWM TPE Yellow
4x18 AWG
105°C
6.4 mm OD
Cable #RF50968-*M†
RKG 4.4T-*/S600 SJOOW CPE Yellow
4x18 AWG
105°C
8.5 mm OD
Cable #RF50644-*M†
Weld Flash Immune,
Flame Resistance
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters. Consult factory for other lengths.** Standard coupling nut material is nickel plated brass "RKG .."; "RKGV .." indicates stainless steel.† See Section N of Connectivity Catalog for reelfast ® cable information.
RKGV ..**
RKG ..**
• Straight Female Connector
• NEMA 1, 3, 4, 6P
• IEC IP 68 Protection
• 250 V, 4 A
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters.** Locking sleeve material is POM.."PKG..Z".† See Section N of Connectivity Catalog for reelfast® cable information.
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters.** Locking sleeve material is POM.."PKG..Z".† See Section N of Connectivity Catalog for reelfast® cable information.
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters.** Standard coupling material is nickel plated brass.."PKG..M"; "PKGV..M" indicates stainless steel.† See Section N of Connectivity Catalog for reelfast® cable information.
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters.** Standard coupling material is nickel plated brass.."PKG..M"; "PKGV..M" indicates stainless steel.† See Section N of Connectivity Catalog for reelfast® cable information.
* Length in Meters. Standard cable lengths are 2, 4, 5, 6, 8 and 10 meters. Consult factory for other lengths.** Standard coupling nut material is nickel plated brass "RKM .."; "RK .." indicates nylon, "RKV .." indicates stainless steel, and "RKVH .." indicates stainless steel hex.† See Section N of Connectivity Catalog for reelfast ® cable information.
• Straight Female Connectors
• NEMA 1, 3, 4, 6P
• IEC IP 67 Protection
• 300 V, 9 A
2 and 3-Wire 7/8" minifast ® Cordsets, Standard
RKM..**
RKVH..
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
* Length in Meters. Standard cable lengths are 2, 4, 5, 6, 8 and 10 meters. Consult factory for other lengths.** Standard coupling nut material is nickel plated brass "RKM .."; "RK .." indicates nylon, "RKV .." indicates stainless steel, and "RKVH .." indicates stainless steel hex.† See Section N of Connectivity Catalog for reelfast ® cable information.
3 and 4-Wire 7/8" minifast ® Cordsets, Standard
RKM..**
• Straight Female Connectors
• NEMA 1, 3, 4, 6P
• IEC IP 67 Protection
• 300 V, 9 A
RKVH..**
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
* Length in Meters. Standard cable lengths are 2, 4, 5, 6, 8 and 10 meters. Consult factory for other lengths.** Standard coupling nut material is nickel plated brass "RKM .."; "RK .." indicates nylon, "RKV .." indicates stainless steel, and "RKVH .." indicates stainless steel hex.† See Section N of Connectivity Catalog for reelfast ® cable information.
5-Wire 7/8" minifast ® Cordsets, Standard
RKM..**
• Straight Female Connectors
• NEMA 1, 3, 4, 6P
• IEC IP 67 Protection
• 300 V, 9 A
RKVH..**
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters. Consult factory for other lengths.** Standard coupling nut material is nickel plated brass "KB .."; "KBK .." indicates nylon and "KBV .." indicates stainless steel.† See Section N of Connectivity Catalog for reelfast® cable information.
• Straight Female Connectors
• NEMA 1, 3, 4, 6P
• IEC IP 67 Protection
• 250 V, 4 A
3-Wire ½" microfast ® Cordsets, Standard Duty
KBK..**
KB..**
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters. Consult factory for other lengths.** Standard coupling nut material is nickel plated brass "KB .."; "KBK .." indicates nylon and "KBV .." indicates stainless steel.† See Section N of Connectivity Catalog for reelfast ® cable information.
• Straight Female Connectors
• NEMA 1, 3, 4, 6P
• IEC IP 67 Protection
• 250 V, 4 A
4 and 5-Wire ½" microfast ® Cordsets, Standard Duty
KBK..**
KB..**
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters. Consult factory for other lengths.** KBE large plug body has no stainless steel or nylon options.† See Section N of Connectivity Catalog for reelfast ® cable information.
3 and 5-Wire ½" microfast ® Cordsets, Large Plug Body
KBE..**
• Straight Female Connectors
• NEMA 1, 3, 4, 6P
• IEC IP 67 Protection
• 250 V, 4 A
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com