Date: 9-3-2019 Drawn By: L.Owen Weight: 15,481 lbs Jarrett Concrete Products 615-792-9332 2012 Hwy 12 South, Ashland City, TN 37015 S.T.E.P. Tank 1500 Gallon Side View Top View 3" 70" 152" 146" 3" 3" 64" 6" 60" 48" 4" or 6" Boot Different inlet size inlet openings and locations are available by special order. Different access openings and adaptors rings are available by special orders. Height and lengths of tanks can be altered to adapt to conditions by special order. Jarrett Concrete reserves the right to make changes without notice. ALL TANKS SOLD BY JCP NEEDS TO BE WATER TESTED WITHIN FIVE BUSINESS DAYS FROM THE TIME WE SET THE TANKS. IF THE TANKS IS NOT TESTED WITHIN FIVE BUSNIESS DAYS, IT IS ASSUMED YOU HAVE OPTED FOR A VACUUM TEST AT YOUR EXPENSE. IT IS THE CUSTOMER'S RESPONSIBILITY TO CORDINATE AND SCHEDULE THE WATER TEST WITH THE LOCAL INSPECTOR. 28 Day, 5,000 PSI Concrete #4 Rebar @12"o.c./e.w. Grade 60 W/ 6" Boots the Inverts Drops 1" Meets ATSM C-1227, 990, 923 Monolithic Tank Design "Top Tight" Patent Pending H-20 Traffic Rated Print Not To Scale Cast in place 24" Adenus riser adapter on 18" raw hole Cast in place 24" Adenus riser adapter on 20" raw hole
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Date: 9-3-2019Drawn By: L.Owen
Weight: 15,481 lbs
Jarrett Concrete Products 615-792-9332
2012 Hwy 12 South, Ashland City, TN 37015
S.T.E.P. Tank 1500 Gallon
Side View
Top View
3"
70"
152"
146"
3"
3"
64"
6"
60"
48"
4" or 6"
Boot
Different inlet size inlet openings and locations
are available by special order.
Different access openings and adaptors rings
are available by special orders.
Height and lengths of tanks can be altered to
adapt to conditions by special order.
Jarrett Concrete reserves the right to make
changes without notice.
ALL TANKS SOLD BY JCP NEEDS TO BEWATER TESTED WITHIN FIVE BUSINESSDAYS FROM THE TIME WE SET THE TANKS.IF THE TANKS IS NOT TESTED WITHIN FIVEBUSNIESS DAYS, IT IS ASSUMED YOU HAVEOPTED FOR A VACUUM TEST AT YOUREXPENSE. IT IS THE CUSTOMER'SRESPONSIBILITY TO CORDINATE ANDSCHEDULE THE WATER TEST WITH THELOCAL INSPECTOR.
28 Day, 5,000 PSI Concrete
#4 Rebar @12"o.c./e.w. Grade 60
W/ 6" Boots the Inverts Drops 1"
Meets ATSM C-1227, 990, 923
Monolithic Tank Design
"Top Tight" Patent Pending
H-20 Traffic Rated
Print Not To Scale
Cast in place 24"
Adenus riser adapter
on 18" raw hole
Cast in place 24"
Adenus riser adapter
on 20" raw hole
STA-RITE® JP Series Signature 2000® composite 4" submersible pumps
Precision-engineered, corrosion-resistant Signature 2000® Composite Pumps in 10, 15, 20 and 30 GPM deliver efficient, dependable performance even in rough, aggressive water. Heads to over 650 feet and capacities to 45 GPM. Built to deliver long-term, trouble-free service.
These pumps feature the proven SignaSeal™ staging system. Floating impeller design resists sand and reduces sand locking.
APPliCATionSWater systems…for residential, industrial, commercial, multiple housing and farm use.
intermediate Bearing: (On larger units) polycarbonate, nitrile rubber and stainless steelimpellers: AcetalDiffusers: PolycarbonateSuction Caps: Polycarbonate with stainless steel insertThrust Pads: Proprietary spec.Shaft and Coupling: Stainless steelintake: Fiberglass-reinforced thermoplasticintake Screen: PolypropyleneCable Guard: Stainless steelCheck Valve: AcetalAgency listings: CSA
Nylatron® is a registered trademark of Polymer Corp. All other brand or product names are trademarks or registered trademarks of Pentair Ltd.
FEATurESProven Staging System: Our proven SignaSeal staging system incorporates a harder-than-sand ceramic wear surface that when incorporated with our floating impeller design, greatly reduces problems with abrasives, sand lock-up and running dry.Discharge: Corrosion-resistant fiberglass-reinforced thermoplastic for durability in aggressive water. Large octagon wrench area for ease of installation.Discharge Bearing: Exclusive self-lubricating Nylatron bearing resists wear from sand.intake: Corrosion-resistant fiberglass-reinforced thermoplastic for durability in aggressive water.Shaft: Positive drive from 7/16" hexagonal heavy-duty 300 grade stainless steel.Coupling: Stainless steel press fit to pump shaft. Couples to all standard NEMA motors.Shell: Heavy-walled corrosion-resistant stainless steel. Threaded for easy servicing.Hardware: All screws, washers and nuts are corrosion-resistant 300 grade stainless steel.Check Valve: Durable internal poppet-type check valve.Cable Guard: Corrosion-resistant stainless steel guard protects motor leads. Tapered ends prevent pump from catching on well.intake Screen: Corrosion-proof polypropylene. Pentek® XE Series™ Motor: 2 and 3 wire NEMA standard all stainless construction water-filled motors.
1 S4559wS
STA-RITE® JP Series Signature 2000® composite 4" submersible pumps
* Length and weight are approximate.**For 10 GPM, 15 GPM, 20 GPM and 30 GPM discharge is 1-1/4" NPT.NOTE: On 2 HP and larger pumps – Motor, Control Box or Magnetic Starter must be ordered separately.
orDErinG inForMATion
GPMMoTor TyPE HP STGS. PH VolT
ASSEMBlED PuMP PuMP EnD MoTor ConTrol BoXCATAloG nuMBEr
STA-RITE® JP Series Signature 2000® composite 4" submersible pumps
CAUTION: DO NOT use pump at flow rates indicated by the symbol ‘—’. To do so can cause premature failure of unit. Pump warranty void when failure occurs under these conditions. Tested and rated in accordance with water Systems Council Standards.NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a 75 PSI relief valve.
Relief valve must be capable of relieving entire flow of pump at relief pressure.
10 GAllonS PEr MinuTE PuMP PErForMAnCE (CapaCity in Gallons per Minute)
STA-RITE® JP Series Signature 2000® composite 4" submersible pumps
CAUTION: DO NOT use pump at flow rates indicated by the symbol ‘—’. To do so can cause premature failure of unit. Pump warranty void when failure occurs under these conditions.Tested and rated in accordance with water Systems Council Standards.NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a 75 PSI relief valve.
Relief valve must be capable of relieving entire flow of pump at relief pressure.
15 GAllonS PEr MinuTE PuMP PErForMAnCE (CapaCity in Gallons per Minute)
STA-RITE® JP Series Signature 2000® composite 4" submersible pumps
CAUTION: DO NOT use pump at flow rates indicated by the symbol ‘—’. To do so can cause premature failure of unit. Pump warranty void when failure occurs under these conditions. Tested and rated in accordance with water Systems Council Standards.NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a 75 PSI relief valve.
Relief valve must be capable of relieving entire flow of pump at relief pressure.
20 GAllonS PEr MinuTE PuMP PErForMAnCE (CapaCity in Gallons per Minute)
STA-RITE® JP Series Signature 2000® composite 4" submersible pumps
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM PH: 888-782-7483 ORDERS FAX: 800-426-9446Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
CAUTION: DO NOT use pump at flow rates indicated by the symbol ‘—’. To do so can cause premature failure of unit. Pump warranty void when failure occurs under these conditions. Tested and rated in accordance with water Systems Council Standards.NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a 75 PSI relief valve.
Relief valve must be capable of relieving entire flow of pump at relief pressure.
30 GAllonS PEr MinuTE PuMP PErForMAnCE (CapaCity in Gallons per Minute)
Aug. 12 SStteepprrooss HHoossee aanndd VVaallvvee AAsssseemmbblliieess
DASCV-_ _ _- _ _GPM
General Specifications
• Pipe and PVC
fittings: Sch 40 pvc
pressure; solvent
welded / threaded
and sealed with
PTFE pipe thread
sealant
• 1/2" models made
with pex quick
disconnect
working pressure
= 250 psi @ 73◦ F
and flexible pex
pipe working
pressure = 160
psi@ 73◦ F
• Assembled to
ensure discharge
assembly does not
prohibit routine
maintenance.
• Union attached
for easy pump
removal
• Ball Valve included
for manual cut off
• Ball Check valve
provided for auto
flushing the vault
849 Aviation
Parkway
Smyrna, TN
37167
615-427-1824
STEPROS'S discharge assemblies include all the necessary plumbing
components (as specified by the system owner or utility) to convey
effluent from a pump to the collection system. Pictured below, is the
assembly specifically designed for the self cleaing/ vault flush version
of our vault. It is designed with the maintain utility in mind, to
minimize maintenance time and maximize functionality of the vault
and pump.
DASCV = Discharge Assembly Self
Cleaning Vault
Indicates discharge assembly size
05 - 1/2"
100- 1"
125 -1-1/4"
200 - 2"
Indicates pump size:
10
15
20
30
50
DASCV-05-10GPM
MUNICIPAL OPEN PROFILE SEWER PIPE & FITTINGS
PVC Gravity Flow Systems manufactured to CSA
and ASTM standards
IPEX Ultra-RibTM Pipe and Fittings
(200 mm – 600 mm) (8" – 24" )
CSA B182.4 and ASTM F794
IPEX Ultra-Rib™ is a gravity flow PVC sewerpipe with concentric reinforcing ribs thatencircle the pipe to provide superior ringstiffness and performance. It is an extruded,seamless pipe made from high grade PVC
compound.
Ultra-Rib is available in standard sewer sizes from200mm to 600 mm (8” – 24”). Its optimized profile
design offers strength and reliability, as well aseconomy and superior flow rates.
Features and Benefits
Ultra-Rib offers many advantages over traditional materials, as well asother plastic sewer pipes. Some of these advantages include:
Tight Joints & Lower Treatment Costs: Eliminate infiltration and exfiltration. Ultra-Rib’s50 psi capable joints easily outperform concrete and corrugated PE joints.
Superior Flow Characteristics: Because of the smooth inside wall of Ultra-Rib, aManning’s coefficient of 0.009 can be used when designing systems using Ultra-Ribpipe. This compares with Manning’s coefficients of up to 0.023 for other materialslike clay or concrete.
Abrasion Resistance: Ultra-Rib has been proven to be more abrasion resistant thanother profile pipes, and has out-performed concrete pipe in testing at California StateUniversity.
Chemical Resistance: PVC is virtually immune to chemical attack from any type ofsewage. Hydrogen Sulphide attack, which causes millions of dollars of damage toconcrete and metal infrastructure, will not affect Ultra-Rib.
Stress Crack Resistance: While some HDPE pipes have been found to crackprematurely under load, Ultra-Rib’s tough PVC construction and superior formulationhas been proven to be immune to these problems.
Aug. 17 SStteepprrooss MMaaxxiimmuumm FFiilltteerr
Technical Specifications
Polypropylene
Schedule 40 PVC
1/8" solids or
smaller
15.3 ft² effective
screen area
Features
Unique inside to
compliment
surface area
with ease of
cleaning and
removal of
buildup.
Superior pump
protection
Maximum
surface area to
ensure delivery
of water to the
pump
849 Aviation Parkway Smyrna,
TN 37167
615-427-1824
STEPROS'S maximum filter series is designed to meet your filtration
requirements. Our filter is unique in design to benefit your
preventative maintenance program Our maximum filter used in
conjunction with our Self Cleaning Vault repels solids back into the
tank instead of collecting them thus providing longer periods of time
between cleaning and increase in pump life.
MF 12
Underside/Inside View
Information Technology Solutions Control/Pump Duty Float Switches
www.ezonsite.com
NNoorrmmaallllyy OOppeenn ((NN//OO)):: Pump duty. As the float raises 1” (5º) above horizontal, the contact becomes closed and completes the circuit. This float is generally used to turn on pumps.
Normally Closed (N/C): Control duty. As the float falls 1” (5º) below horizontal, the contact becomes closed and completes the circuit. This float is generally used to turn off pumps as a fail-safe method (redundant off).
Narrow Angle Floats (N/0): Control duty. As the float raises 1” (10º) above horizontal, the contact becomes closed and completes the circuit. This float is generally used to turn on pumps. With a narrow-angle activated actuation, these are often used in pump stations and recirculating sand filters (RSFs) where water levels require more precision.
Applications For use with EZ-
Onsite control Panels
Pump Stations
Recirculation Sand
Filter Beds.
STEP and STEG tanks
These floats are constructed of a
durable polypropylene outer shell and a solid polyurethane foam interior. They are designed for accurate liquid level control in many applications including sewage and wastewater environments. Float switches can be utilized to signify specific water levels for direct alarm actuation, and can be used as a “pump-on” or “pump off” switch.
SPECIFICATIONS 2.90 x 3.75”
Min/max
temperatures 32-
170ºF
power cord is chlorinated polyethylene type SJOOW- 300v
Grade Rings & Grade Ring InsertsApplicationsOrenco’s grade rings extend existing access risers to needed lengths. Orenco’s grade ring inserts connect sections of access riser pipe for strong, watertight bonding.
GeneralAn Orenco® grade ring is constructed of a section of PVC riser pipe with an insert affixed to its edge. The grade ring insert is bonded to the end of the riser to serve as a coupling. MA320 or ADH100 adhesive is used to bond grade ring inserts to riser pipes.
Standard ModelsSee specifications chart on page 2 for standard models of grade ring inserts.
Product Code Diagrams
Orenco® grade rings with grade ring inserts attached
Orenco grade ring inserts
GR
Riser pipe style:Blank = Kor-FLo™, Perma-Loc, and Ultra-Rib™ in 21-, 24-, 30-, 36-in. (525-, 600-, 750, 900-mm) diametersU = Ultra-Rib™ in 12- and 18-in. (300- and 450-mm) diameters
Where to Use n Designedforalltypesofjointswheremaximumdepthofsealantwillnotexceed1/2in.
n Excellentforsmalljointsandfillets,windows,doorframes,reglets,flashing,commonroofingdetail applictions,andmanyconstructionadhesiveapplications.
n Suitableforverticalandhorizontaljoints;readilyplaceableat40°F n Has many applications as an elastic adhesive between materials with dissimilar coefficients of expansion.
n Submergedconditions,suchascanalandreservoirjoints.
n Highelasticity-curestoatough,durable,flexibleconsistencywithexceptionalcutandtear-resistance. n Stressrelaxation. n Excellentadhesion-bondstomostconstructionmaterialswithoutaprimer.
n Excellentresistancetoaging,weathering. nProvenintoughclimatesaroundtheworld.
n Canbeappliedtogreenconcrete24hoursafterpour n Canbeappliedtodampconcrete1houraftergettingwet
n Odorless,non-staining.
n Jetfuelresistant. n CertifiedtotheNSF/ANSIStandard61forpotablewater.
n Urethane-based;suggestedbyEPAforradonreduction. n Paintablewithwater-,oil-andrubber-basedpaints.
n Capableof±35%jointmovement.
Chemical Resistance Goodresistancetowater,dilutedacids,anddilutedalkalines.ConsultTechnicalServiceforspecificdata.
RESULTS MAY DIFFER BASED UPON STATISTICAL VARIATIONS DEPENDING UPON MIXING METHODS AND EQUIPMENT, TEMPERATURE, APPLICATION METHODS, TEST METHODS, ACTUAL SITE CONDITIONS AND CURING CONDITIONS.
PRIOR TO EACH USE OF ANY SIKA PRODUCT, THE USER MUST ALWAYS READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS ON THE PRODUCT’S MOST CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET WHICH ARE AVAILABLE ONLINE AT HTTP://USA.SIKA.COM/ OR BY CALLING SIKA’S TECHNICAL SERVICE DEPARTMENT AT 800.933.7452 NOTHING CONTAINED IN ANY SIKA MATERIALS RELIEVES THE USER OF THE OBLIGATION TO READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS FOR EACH SIKA PRODUCT AS SET FORTH IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET PRIOR TO PRODUCT USE.
Cons
tructi
onCoverage
How to UseSurface Preparation Cleanallsurfaces.Jointwallsmustbesound,clean,frost-free,andfreeofoilandgrease.Curingcompoundresiduesand
Tooling and Finishing Toolsealanttoensurefullcontactwithjointwallsandremoveairentrapment.Jointdimensionshouldallowfor1/4inchminimumand1/2inchmaximumthicknessforsealant.Properdesignis2:1widthtodepthratio,Foruseinhorizontaljointsintrafficareas,theabsoluteminimumdepthofthesealantis1/2in.andclosedcellbackerrodisrecommended.
Over Painting Allow1-weekcureatstandardconditionswhenusingSikaflex-1aintotalwaterimmersionsituationsandpriortopainting.
PRIOR TO EACH USE OF ANY SIKA PRODUCT, THE USER MUST ALWAYS READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS ON THE PRODUCT’S MOST CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET WHICH ARE AVAILABLE ONLINE AT HTTP://USA.SIKA.COM/ OR BY CALLING SIKA’S TECHNICAL SERVICE DEPARTMENT AT 800.933.7452 NOTHING CONTAINED IN ANY SIKA MATERIALS RELIEVES THE USER OF THE OBLIGATION TO READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS FOR EACH SIKA PRODUCT AS SET FORTH IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET PRIOR TO PRODUCT USE.
10.1 oz Cartridge: Yield in Linear feet
Depth 1/4" 3/8" 1/2"
Width
1/4" 24.3
3/8" 16.2 10.8
1/2" 12.1 8.1 6.1
3/4" 8.1 5.4 4.0
1" 3.0
1.25" 2.4
1.5" 2.0
20 oz Sausage: Yield in Linear feet
Depth 1/4" 3/8" 1/2"
Width
1/4" 48.1
3/8" 32.1 21.4
1/2" 24.1 16.0 12.0
3/4" 16.0 10.7 8.0
1" 6.0
1.25" 4.8
1.5" 4.0
1 gallon: Yield in Linear feet
Depth 1/4" 3/8" 1/2"
Width
1/4" 307.9
3/8" 205.3 136.8
1/2" 153.9 102.6 77.0
3/4" 102.6 68.4 51.3
1" 38.5
1.25" 30.8
1.5" 25.7
Cons
tructi
on
Visit our website at usa.sika.com 1-800-933-SIKA NATIONWIDERegional Information and Sales Centers.ForthelocationofyournearestSikasalesoffice,contactyourregionalcenter.
KEEP CONTAINER TIGHTLY CLOSED. KEEP OUT OF REACH OF CHILDREN. NOT FOR INTERNAL CONSUMPTION. FOR INDUSTRIAL USE ONLY. FOR PROFESSIONAL USE ONLY.
For further information and advice regarding transportation, handling, storage and disposal of chemical products, users should refer to the actual Safety Data Sheets containing physical, ecological, toxicological and other safety related data. Read the current actual Safety Data Sheet before using the product. In case of emergency, call CHEMTREC at 1-800-424-9300, International 703-527-3887.Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product’s most current Product Data Sheet, product label and Safety Data Sheet which are available online at http://usa.sika.com/ or by calling Sika’s Technical Service Department at 800-933-7452. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Product Data Sheet, product label and Safety Data Sheet prior to product use.SIKA warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyer’s sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIESEXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.SALE OF SIKA PRODUCTS ARE SUBJECT SIKA’S TERMS AND CONDITIONS OF SALE AVAILABLE AT HTTP://USA.SIKA.COM/ OR BY CALLING 201-933-8800.
ISO 9001Certificate # FM 69711
RC 14001Certificate # RC 510999
PRIOR TO EACH USE OF ANY SIKA PRODUCT, THE USER MUST ALWAYS READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS ON THE PRODUCT’S MOST CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET WHICH ARE AVAILABLE ONLINE AT HTTP://USA.SIKA.COM/ OR BY CALLING SIKA’S TECHNICAL SERVICE DEPARTMENT AT 800.933.7452 NOTHING CONTAINED IN ANY SIKA MATERIALS RELIEVES THE USER OF THE OBLIGATION TO READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS FOR EACH SIKA PRODUCT AS SET FORTH IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET PRIOR TO PRODUCT USE.
Limitations n Allow1weekcureatstandardconditionswhenusingSikaflex-1aintotalwaterimmersionsituations.
n Whenovercoatingwithwater,oilandrubberbasedpaints,compatibilityandadhesiontestingisessential.
n Sealantshouldbeallowedtocurefor7dayspriortoovercoating
n Avoidexposuretohighlevelsofchlorine.(Maximumcontinuouslevelis5ppmofchlorine.)
n Maximumdepthofsealantmustnotexceed1/2in.;minimumdepthis1/4in.
n Maximumexpansionandcontractionshouldnotexceed35%ofaveragejointwidth.
n Donotcureinthepresenceofcuringsiliconesealants.
n Avoidcontactwithalcoholandothersolventcleanersduringcure.
n Donotapplywhenmoisture-vapor-transmissionconditionexistsfromthesubstrateasthiscancausebubbling withinthesealant.
n Useopenedcartridgesanduni-pacsausagesthesameday.
n Whenapplyingsealant,avoidair-entrapment.
n Sincesystemismoisture-cured,permitsufficientexposuretoair.
n Whitecolortendstoyellowslightlywhenexposedtoultravioletrays.
n Lightcolorscanyellowifexposedtodirectgasfiredheatingelement.
n TheultimateperformanceofSikaflex-1adependsongoodjointdesignandproperapplicationwithjointsurfaces properlyprepared.