Page 1: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Thermal Power Station

Chemical Heat Heat Kinetic Kinetic Electrical

generatorboiler

turbine electrical energy

Page 2: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

boiler

turbines

steam

generator

condenser

electrical energy

Page 3: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Nuclear PowerNuclear power stations operate similarly to thermal power stations, but instead of burning fossil fuels to produce heat, a nuclear reaction takes place inside a reactor.

Reactor Turbine Generator

Nuclear Heat Heat Kinetic Kinetic Electrical

Page 4: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.
Page 5: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Uranium is a fuel used in nuclear power stations.

It is non-renewable, so it will eventually run-out.

However, it has the advantage that a small amount of Uranium can produce huge amounts of energy.

1 kg of Coal 30 MJ

1 kg Uranium 5,000,000 MJ

The major disadvantage of nuclear power is that the waste produced is radioactive.

It has to be stored underground in lead and concrete containers for thousands of years.

Page 6: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Chain Reactions

Neutron

Uranium Nucleus

Fission Products

+ ENERGY

Neutrons

A neutron is fired at a Uranium nucleus causing it to split-up into fragments.

The splitting of the Uranium nucleus is called fission, so we call the fragments fission products.

When the Uranium nucleus splits energy is released (which heats water in boiler).

More neutrons are also released which can go on to split more Uranium nuclei.

Control rods are used in nuclear reactors to absorb some of these new neutrons preventing too much energy being released in a short time.

Page 7: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Yellow Book

Power Stations – Page 79

Q12, Q13, Q16, Q18, Q20, Q24

Page 8: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Hydroelectric Power Station

turbine + generatorlow level reservoir

water flow

high level reservoir

Page 9: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

turbine

reservoirtransmission

lines

transformer

water flow

generator

Page 10: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Water is stored at a height behind a dam.

The water is allowed to flow down to a lower level.

Potential Kinetic

The water flows through a turbine spinning the blades which then turns the generator.

Kinetic Electrical

Page 11: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Pumped Hydroelectric Power

In a pumped hydroelectric power station water can be pumped back-up from the low level reservoir to the higher level.

This usually happens throughout the night when the demand for electricity is lower.

In the morning when we wake up and there is a demand for electricity, the water is allowed to flow back down again to generate the electricity we need.

Page 12: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.
Page 13: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.
Page 14: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.
Page 15: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.
Page 16: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.
Page 17: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.
Page 18: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.
Page 19: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

x

÷

Potential Energy

EP

m hg

Example 1

A dam stores 1.2 x 1010 kg of water and is 430 m above the turbine of a hydroelectric scheme.

(a) Calculate the potential energy of the water in the dam.

(b) The pipe delivers 1,280 kg of water to the turbine every second. Calculate the energy delivered to the power station in one second.

h g mEP

Page 20: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

(a)

(b)

So there are 5.5 x 106 J of energy produced in one second.

That means 5.5 x 106 J per second.

But since

The power output is 5.5 x 106 W, or 5.5 MW.

kg 101.2m 10m 430h

-1kg N 10g

?EP h g mEP

43010101.2 10 J 105.16E 13

P

kg 1,280mm 430h

430 10 1,280 J 105.5E 6

P

?EP

-1kg N 10g

h g mEP

second per Joule 1 Watt 1

Page 21: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Question 1

A dam releases 750 kg of water down a pipe every second. The dam is 620 m above the turbine.

(a) Calculate the potential energy of this amount of water at the start.

(b) Calculate the power output of the power station if it were only 50% efficient.

4,650,000 J = 4.65 MJ

4.65 MJ = 4.65 MW

50% of 4.65 MW = 2.325 MW

Page 22: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Yellow Book

Energy Conversions – Page 83

Q48 and Q51

Page 23: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

When an energy transfer takes place some energy is

always wasted or degraded through heat.

For example, in a lamp

Electrical Light + Heat

“Energy in” is the electrical energy.

“Energy out” is the light energy.

“Wasted energy” is the heat energy.

If an energy transfer is efficient then only a small amount of energy is wasted.

Most of the “energy in” is changed to useful “energy out”.

Efficiency

Page 24: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

x

÷

Eout

Eff Ein

Quantity Unit

Energy Out ( Eout )

Efficiency ( Eff )

Energy In ( Ein )

Joules ( J )

NO UNIT

Joules ( J )

Some energy is always wasted so the efficiency is always less than 1.

Sometimes the efficiency is written as a percentage, for example

1 can be written as 100%

0.75 can be written as 75%

0.37 can be written as 37%

( decimal is multiplied by 100 to give percentage )

Page 25: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Example 1

A nuclear power station produces 1,500 MJ of electrical energy.

This requires 5,000 MJ of heat energy from the reactor.

Calculate the efficiency of the power station.

** NO UNIT **

?Eff

MJ 1,500Eout

J 10 5,000 6

in

out

EE

Eff

5,0001,500

0.3Eff

J 10 1,500 6

MJ 5,000Ein

1000.3efficiency % 30%

Page 26: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Efficiency can also be calculated from input and output powers.

x

÷

Pout

Eff Pin

Quantity Unit

Power Out ( Pout )

Efficiency ( Eff )

Power In ( Pin )

Joules ( J )

NO UNIT

Joules ( J )

A thermal power station has a percentage efficiency of 33%.

It produces 600 MW of electrical power.

How much power needs to be produced in the boiler?

% 33Eff

MW 600Pout

EffP

P outin

0.3310600 6

MW 1,800Pin ?Pin

0.33

Page 27: Thermal Power Station Chemical HeatHeat Kinetic Kinetic Electrical generator boiler turbine electrical energy.

Yellow Book

Efficiency – Page 80

Q25 (a), (d) and (f)

Q28, Q30, Q31, Q33, Q34, Q36