The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate Alpha Arsano, Nikhilesh Ghanta, Leslie K. Norford Sept 21, 2018 1 Building Technology Computation for Design and Optimization
25

The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Feb 26, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Alpha Arsano, Nikhilesh Ghanta, Leslie K. Norford Sept 21, 2018

1

Building Technology Computation for Design and Optimization

Page 2: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Precedent

Cornell Green Building, New York, 2017 Tallest passive house building, 76 m high

Energy reduction: 70% Carbon emission reduction: 882 tons/year

greenbuildingelements.comClimate Zone 4A

Orchards at Orenco, Oregon Largest passive house multi-family building in the US

Without active heating and cooling

reachcdc.orgClimate Zone 4C

2

Page 3: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Can we build the next largest Passive House commercial building?

High performance envelope + passive building strategies

3

Page 4: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Volpe

Climate Zone 5A volpe.mit.edu

4

Page 5: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Project goal

Indoor Air Quality Thermal Comfort Low Energy Climate Change

5

Number of hours (hrs)

Base case

Proposed

Energy use intensity (EUI in kWh/m2)

Base case

Proposed

Active systems

Passive strategies

Page 6: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Strategies

Passive house Beyond passive house

Glazing

Insulation

Thermal bridge

Thermal mass

Solar gain/shade

Natural ventilation

Low energy fresh air supply

Radiative cooling 6

Page 7: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Integration of passive strategies

Tin Range

Current Climate

7

Passive cooling

Direct ventilation

Nighttime radiative cooling

Passive heating

Solar radiation captured and

internal heat gain maintained

Page 8: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Volpe- design concept Solar chimney: to enhance

buoyancy ventilation

Pressure ring: to enhance

wind ventilation

Prevailing Wind: W, SW, NW

Average speed at weather station: 5 m/s

Wind speed on site: 2 m/s

N

Indoor atrium: enhance

passive conditioning

Commercial / Office

8

Page 9: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

N

Pressure ring ACH [ ]

Programmatic arrangement

Regulating Window sizing

Window opening orientations

Volpe Pressure ring

9

Page 10: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Passive cooling

Solar chimney: to enhance

buoyancy ventilation

Pressure ring: to enhance

wind ventilation

Indoor air quality Remove indoor heat gain Physiological cooling

10

Page 11: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Office at desk height. Opposite side fresh air inlet openings.

Mean age of air, simulation

Mean age of air in sec.

300

250

200

150

100

50

0

Indoor air quality

11

Page 12: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Winter DOAS + Solar gain

Minimum ventilation for indoor air quality

DOAS

(Dedicated outdoor air

system)

Displacement: fresh air

distribution

Solar gain

12

Page 13: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Winter Passive conditioning of atrium

Atrium space temperature: close to office inlet. Solar gain is maximized and minimum fresh air is supplied.

Temperature oC

30

25

20

15

10 13

Top atrium

Middle atrium

Bottom atrium

Page 14: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Peak Summer Day: DOAS + Radiant floor

Minimum ventilation

for indoor air quality

DOAS

(Dedicated outdoor air system)

Water cooled at night.

(Radiative cooling to the sky)

Radiative slab cooling

Solar shading

Nighttime: Night flushing + roof pond cooled

to night sky, Maximum ventilation

Water cooled at night.

(Radiative cooling to the night

sky)

Night ventilation.

Pressure ring for night wind

ventilation

14

Page 15: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Customized DOAS (Dedicated Outdoor System) Fresh air supply and dehumidification

Outdoorair

AAerEnthalpyWheel

AAerMembraneIndoorair

15

Radiative cooling

Dehumidification Membrane

1

2

3

1

2

3

Page 16: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Customized DOAS (Dedicated Outdoor System) Fresh air supply and dehumidification

16

Page 17: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Customized DOAS (Dedicated Outdoor System) Fresh air supply and dehumidification [From August 5 -13]

17

Page 18: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

12

16

20

24

28

32

36

40

0 3 6 9 12 15 18 21 24 3 6 9 12 15 18 21 24 3 6 9 12 15 18 21 24 3 6 9 12 15 18 21 24

Occup

ancy

Tempe

rature(inde

gC)

Current Climate (July 8-14): Interior temp with internal loads and reduced solar gain

T_in T_out AdpaLveupperlimit AdapLvelowerlimit OperaLonalhrs

Thermal comfort evaluation Summer week Natural ventilation + Active thermal mass + solar shading

18

Page 19: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

12

16

20

24

28

32

36

40

0 3 6 9 12 15 18 21 24 3 6 9 12 15 18 21 24 3 6 9 12 15 18 21 24 3 6 9 12 15 18 21 24

Occup

ancy

Tempe

rature(inde

gC)

2080(July8-14):Interiortempwithinternalloadsandreducedsolargain

T_in T_out AdpaLveupperlimit AdapLvelowerlimit OperaLonalhrs

Thermal comfort evaluation-2080

19

Summer week Natural ventilation + Active thermal mass + solar shading

Page 20: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Tin Range

2080: Modes of operations Passive strategies + Active cooling using proposed DOAS

20

Passive cooling

Direct ventilation

Night cooling, radiative

cooling

Active Cooling

Passive heating

Solar radiation captured

and internal heat gain

maintained

Page 21: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Pathway to Net Zero

HVAC+PassiveStrategies(Proposal)

DOAS+PassiveStrategies(Proposal)

USAverageforCommercial(USDOE)

19.5

[HeaLng]EUI(kWh/m2)

PassiveHouse,Zone5(PHIUS+2018Space

condiLoningesLmator)

[Cooling]EUI(kWh/m2)

21

27 27

3 4

0 0.5

21

Page 22: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Solar Thermal

Cumulative radiation annual

Solar thermal for hot water 24 m3/day Commercial (DOE) 340 m2 Area required for total water supply (about 1/3rd of roof area).

4.6 kWh/m2 Average solar rad per day.

22

Page 23: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Accommodating Labs

Solar chimney turned

to exhaust stacks

Enthalpy Wheels (DOAS)

Changed with Run-around Coil to

prevent air mixing

N

Pressure ring allows 30 ACH in average.

Labs require between 4-12 ACH (EPA DOE Ref)

23

Page 24: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

RH[10,90] RH[20,80] RH[40,60]

Lighting Equipment Latent

79

BasePassiveHouseEUI(kWh/m2)

81

106

67 6878

OpLmizedPassiveHouseEUI(kWh/m2)

Programmatic Flexibility

RH[10,90] RH[20,80] RH[40,60]

RH[10,90] RH[20,80] RH[40,60]

Lighting Equipment Heating Cooling DHW

24

Page 25: The path to net-zero passive commercial building · The path to net-zero passive commercial building The role of natural ventilation and thermal mass in a heating dominated climate

Key ideas

Great potential for passive strategies. Design solutions are used to maximize comfort without active systems. Looking at future climate is critical. Current buildings will be challenged under global warming and this has to be part of the design process.

Passive House at Volpe - Pathway to Net Zero

25