Top Banner
The project is supported by the Hungarian Scientific Research Fund (OTKA): T043145 MS test setup for the Magnet Test - Cosmic Challange (MTCC) Data Acquisition and Management in the Calibration Processes of the CMS Barrel Muon Alignment System Szillási, Z. 1 , Bencze, Gy. L. 3,4 , Béni, N. 1 , Imrek, J. 2 , Molnár, J. 2 , Novák, D. 2 ,Raics, P. 1 , Szabó, Zs. 1 , Székely, G. 2 The CMS Barrel Muon Alignment System is composed of a series of elements - each of large quantity -to be calibrated individually and together after assembly. This requires an approach based on modular control and data acquisition HW/SW including data validation features during data taking. The measured data of all calibration steps (including full images) are stored in a database together with the final results obtained after the processing and evaluation of raw data. A dynamic WEB-based reporting tool makes it possible to follow the status of calibration and assembly, and to search for any data. 1 Institute of Experimental Physics, Debrecen University, Debrecen, Hungary H-4001 2 Institute of Nuclear Research (ATOMKI), Debrecen, PO BOX 51. Hungary H-4001 3 Institute of Particle and Nuclear Physics, Budapest, Hungary H-1525 4 CERN, CH-1211 Geneva 23, Switzerland. Calibration bench for the LED holders Camera 1 Precision X-Y table Camera 2 X Y Calibration bench for MABs Result of a camera quality measurement MAB barrel muon chamber Data flow during the muon chamber calibration Chamber Calibration Bench (W98) Stores data locally in ASCII files Photogrammetric measurement by the Survey Group Lab. Server (Linux) MySQL Database Server Automatic EDITOR process runs on the server. Uses MySQL, creates COCOA descr. and grabs results from COCOA output COCOA geometr. reconstruction Data filled Into the DB Data filled into the DB Raw data Data from the LED holder calib. DB Analysed data COCOA input WEB Server (Linux) WEB LAB WEB Analysis Analysed data Data flow during the LED holder calibration LED Holder Calibration Bench (W98) Stores measurements in ASCII files locally Lab. Server (Linux) MySQL Database Server Data filled into the DB Automatic ANALYSIS Process (Java) runs on the server machine Uses MySQL Analysed data used by the Chamber Calibration Bench WEB Server (Linux) http :// kismalac.phys.klte.hu / Fork WEB Raw data Analysed data Optical network of the Barrel Muon Alignment System Camera calibration bench
1

Th e project is supported by the Hungarian Scientific Research Fund (OTKA): T043145

Mar 17, 2016

Download

Documents

Lori

Y. Analysed data used by the Chamber Calibration Bench. WEB. LAB. Analysis. LED Holder C alibration Bench (W98) Stores measurements in ASCII files locally. Lab. Server (Linux) MySQL Database Server. Data filled into the DB. X. Raw data. WEB Server (Linux) - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Th e  project is supported by the Hungarian Scientific Research Fund (OTKA): T043145

The project is supported by the Hungarian Scientific Research Fund (OTKA): T043145

CMS test setup for the Magnet Test - Cosmic Challange (MTCC)

Data Acquisition and Management in the Calibration Processesof the CMS Barrel Muon Alignment System

Szillási, Z.1, Bencze, Gy. L.3,4, Béni, N.1, Imrek, J.2, Molnár, J.2,Novák, D.2 ,Raics, P.1, Szabó, Zs.1, Székely, G.2

The CMS Barrel Muon Alignment System is composed of a series of elements - each of large quantity -to be calibrated individually and together after assembly. This requires an approach based on modular control and data acquisition HW/SW including data validation features during data taking. The measured data of all calibration steps (including full images) are stored in a database together with the final results obtained after the processing and evaluation of raw data. A dynamic

WEB-based reporting tool makes it possible to follow the status of calibration and assembly, and to search for any data.

1 Institute of Experimental Physics, Debrecen University, Debrecen, Hungary H-40012 Institute of Nuclear Research (ATOMKI), Debrecen, PO BOX 51. Hungary H-40013 Institute of Particle and Nuclear Physics, Budapest, Hungary H-15254 CERN, CH-1211 Geneva 23, Switzerland.

Calibration bench for the LED holders

Camera 1Precision X-Y table

Camera 2

X

Y

Calibration bench for MABs

Result of a camera quality measurement

MAB

barrel muon chamber

Data flow during the muon chamber calibration

Chamber Calibration Bench (W98)Stores data locally in ASCII files

Photogrammetric measurementby the Survey Group

Lab. Server (Linux)MySQL DatabaseServer

Automatic EDITORprocess runs on the server. Uses MySQL, creates COCOA descr.and grabs results from COCOA output

COCOA geometr. reconstruction

Data filledInto the DB

Dat

a fil

led

into

the

DB

Rawdata

Data from the LED holder calib. DB

Analyseddata

COCOAinput

WEB Server (Linux)

WEB

LABWEB Analysis

Analysed data

Data flow during the LED holder calibration

LED Holder CalibrationBench (W98)Stores measurementsin ASCII files locally

Lab. Server (Linux)MySQL DatabaseServer

Data filled

into the DB

Automatic ANALYSISProcess (Java) runs on the server machineUses MySQL

Analysed dataused by the ChamberCalibration Bench

WEB Server (Linux)http://kismalac.phys.klte.hu/Fork

WEB

Raw data

Analysed data

Optical network of the Barrel Muon Alignment System

Camera calibration bench