TFO’s OPGW Business TFO’s OPGW Total Solution TFO’s OPGW Business TFO’s Major Fiber TFO's OPGW Solution included cable design, installation, construction supervising and technical support. And provide to differentiated fiber suitable for installation area characteristics. Besides, reduce to installation time &cost through a [Live line installation method] Turnkey Easy Installation Cost Effectiveness Quick maintenance TFO’s OPGW Cable Design Non-metallic Loose Tube Type Al Covered Stainless Steel Loose Tube Type Stainless Steel Loose Tube Type Central Stainless Steel Loose Tube Type ·Standard 6 to 144 fiber count ·Excellent crush resistance performance ·Maintenance data information system ·Power line protection ·Good resistance to strong winds, lightning and short circuit current Optical : Single mode optical fiber(SMF), multi mode optical fiber(MMF) Filling compound : Jelly compound Steel tube : Stainless steel tube AS wire or Al ally : Aluminum clad steel wire or Aluminum alloy wire AS wire or Al ally : Aluminum clad steel wire or Aluminum alloy wire 24 Core 48 Core ·Standard 6 to 144 fiber count ·Excellent crush resistance performance ·Maintenance data information system ·Power line protection ·Good resistance to strong winds, lightning and short circuit current 24 Core 48 Core Optical : Single mode optical fiber(SMF), multi mode optical fiber(MMF), Non-zero dispersion shifted optical fiber(NZ-DSF) Loose tube : Thermoplastic material(polybutylene terephthalate) Central member : Fiber reinforced plastic(FRP) Filling compound : Jelly compound Wrapping tape : Heat resistance tape Al tube : Aluminum tube AS wire or Al alloy : Aluminum clad steel wire or Al alloy wire ·Standard 6 to 48 fiber count ·Excellent crush resistance performance ·Maintenance data information system ·Light weight and small diameter ·Power line protection ·Good resistance to strong winds, lightning and short circuit current ·Standard 6 to 48 fiber count ·Excellent crush resistance performance ·Maintenance data information system ·Light weight and small diameter ·Power line protection ·Good resistance to strong winds, lightning and short circuit current Optical : Single mode optical fiber(SMF), multi mode optical fiber(MMF), Non-zero dispersion shifted optical fiber(NZ-DSF) Filling compound : Jelly compound Color binder : Polyester yarns Stainless steel tube : Stainless steel loose tube AS wire or Al alloy : Aluminum clad steel wire or Al alloy wire Optical : Single mode optical fiber(SMF), multi mode optical fiber(MMF), Non-zero dispersion shifted optical fiber(NZ-DSF) Filling compound : Jelly compound Stainless steel tube : Stainless steel loose tube Al tube : Aluminum tube AS wire or Al alloy : Aluminum clad steel wire or Al alloy wire ANYWAVE REACH C ANYWAVE 200 ANYWAVE FLEX B3 ANYWAVE LL ·Superior performance for long haul networks ·Optimized for effective operating of WDM system ·Lower sensitivity of transmission properties ·Broad-range low attenuation properties ·10Gbps, 40Gbps and higher data rates ·Conspicuous lower attenuation ·Superior bending performance ·Mechanically strippable coating ·Excellent geometric properties for low splicing loss ·Transmission capacity at 1285nm to 1625nm ·Diameter reduction for material cost savings ·Conspicuous lower attenuation ·Superior bending performance ·Mechanically strippable coating ·Excellent geometric properties for low splicing loss ·Transmission capacity at 1285nm to 1625nm ·Fully compliant with ITU-T G.652.D&G.657.A2 ·Allowable bending diameter : 20mm ·1/3 Bending diameter compared to conventional SMF(60mm) ·Good splicing with conventional SMF and ZWPF
4
Embed
TFO’s OPGW Businesstfo.co.kr/theme/basic/img/OPGW Solution.pdf · TFO’s OPGW Business TFO’s OPGW Total Solution TFO’s OPGW Business TFO’s Major Fiber TFO's OPGW Solution
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
TFO’s OPGW Business
TFO’s OPGW Total Solution
TFO’s OPGW Business
TFO’s Major Fiber
TFO's OPGW Solution included cable design, installation, construction supervising and technical support. And provide to differentiated fiber suitable for installation area characteristics. Besides, reduce to installation time &cost through a [Live line installation method]
·Standard 6 to 144 fiber count·Excellent crush resistance performance·Maintenance data information system·Power line protection·Good resistance to strong winds, lightning and short circuit current
Optical : Single mode optical fiber(SMF), multi mode optical fiber(MMF)Filling compound : Jelly compoundSteel tube : Stainless steel tubeAS wire or Al ally : Aluminum clad steel wire or Aluminum alloy wireAS wire or Al ally : Aluminum clad steel wire or Aluminum alloy wire
24 Core 48 Core
·Standard 6 to 144 fiber count·Excellent crush resistance performance·Maintenance data information system·Power line protection·Good resistance to strong winds, lightning and short circuit current
24 Core 48 Core
Optical : Single mode optical fiber(SMF), multi mode optical fiber(MMF), Non-zero dispersion shifted optical fiber(NZ-DSF)Loose tube : Thermoplastic material(polybutylene terephthalate)Central member : Fiber reinforced plastic(FRP)Filling compound : Jelly compoundWrapping tape : Heat resistance tapeAl tube : Aluminum tubeAS wire or Al alloy : Aluminum clad steel wire or Al alloy wire
·Standard 6 to 48 fiber count·Excellent crush resistance performance·Maintenance data information system·Light weight and small diameter·Power line protection·Good resistance to strong winds, lightning and short circuit current
·Standard 6 to 48 fiber count·Excellent crush resistance performance·Maintenance data information system·Light weight and small diameter·Power line protection·Good resistance to strong winds, lightning and short circuit current
Optical : Single mode optical fiber(SMF), multi mode optical fiber(MMF), Non-zero dispersion shifted optical fiber(NZ-DSF)Filling compound : Jelly compoundColor binder : Polyester yarnsStainless steel tube : Stainless steel loose tubeAS wire or Al alloy : Aluminum clad steel wire or Al alloy wire
Optical : Single mode optical fiber(SMF), multi mode optical fiber(MMF), Non-zero dispersion shifted optical fiber(NZ-DSF)Filling compound : Jelly compoundStainless steel tube : Stainless steel loose tubeAl tube : Aluminum tubeAS wire or Al alloy : Aluminum clad steel wire or Al alloy wire
ANYWAVE REACH C
ANYWAVE 200
ANYWAVE FLEX B3
ANYWAVE LL
·Superior performance for long haul networks·Optimized for effective operating of WDM system·Lower sensitivity of transmission properties·Broad-range low attenuation properties
·10Gbps, 40Gbps and higher data rates·Conspicuous lower attenuation·Superior bending performance·Mechanically strippable coating·Excellent geometric properties for low splicing loss·Transmission capacity at 1285nm to 1625nm
·Diameter reduction for material cost savings·Conspicuous lower attenuation·Superior bending performance·Mechanically strippable coating·Excellent geometric properties for low splicing loss·Transmission capacity at 1285nm to 1625nm
·Fully compliant with ITU-T G.652.D&G.657.A2·Allowable bending diameter : 20mm·1/3 Bending diameter compared to conventional SMF(60mm)·Good splicing with conventional SMF and ZWPF
TFO’s OPGW Process Diagram
Product List
① FDH(Fiber Distribution Hub)
① FDH(Fiber Distribution Hub)
② Joint Box② Joint Box
③ Clamp③ Clamp
④ Tension Assembly
④ Tension Assembly
⑤ Vibration Damper
⑥ OPGW
⑦ Suspension Assembly
1
2
3
4
5
6
7
FDH(Fiber Distribution Hub)The FDH is designed and constructed to be suitable for outdoor installation. The housing is sufficiently sturdy to withstand typical handling and installation procedures. The design and layout of the cable guides promote an efficient and ordered positioning of the cable within the hub.
Joint BoxSuitable for OPGW cable connection protection, has the function for direct connections and divergence connection, which can out of 4 cable, installed in the overhead pole, tower.
ClampClamps are used to guide OPGW cables from the top of the structure to the joint box or for grounding the cable. TFO provide proper spacing and holding strength without damaging the cable.
Tension AssemblyTension Assembly is used for OPGW cable route’s fixing and anchor shackling. Usually be installed on the terminal tower, tight tension tower and intersection angle tower etc.
Vibration DamperVibration Dampers effectively reduce the level of Aeolian vibrations on OPGW cables. It respond to wind induced line vibrations that is characterized by high frequency, low amplitude motion.
Suspension AssemblySuspension Assembles are designed for use with OPGW cable at suspension tower positions. Suspension Assemblies reduce static compressive stresses at the support point and cushion the OPGW cable against the dynamic stress of Aeolian vibration.
OPGW(Optical Ground Wire)OPGW is a type of cable that is used in the construction of electric power transmission and distribution lines. Such cable combines the functions of grounding and communications. An OPGW cable contains a tubular structure with one or more optical fibers in it, surrounded by layers of steel and aluminum wire.
TFO’s OPGW Live Line Construction
Procedure
Replacing the existing ground wire by OPGW without power outage on existing transmission line
Preparation
Installation of Supporting rollers
OPGW stringing
Turn-over & Sagging
Retrieval of Support rollersand the disconnecting rope
Jointing & Testing
Pulling Rope
Pulling Rope
Pulling Rope
Guide Rope
E/w
Guide Rope
Supporting Roller Mobile Unit Existing Ground Wire